Search NASA⌕ Search

SEARCH · Search NASA

Results for “noise reduction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Variance reduction techniques for Monte Carlo neutron noise simulations

The small fluctuations of the neutron flux caused by small perturbations of the macroscopic cross-sections take the name of neutron noise. Advanced Monte Carlo methods have been recently proposed in order to solve the neutron noise equations in the frequency domain, which allows establishing reference solutions to validate faster but approximate deterministic solvers. Due to the presence of particles carrying two statistical weights (for the real and imaginary components of the noise field), both of which may be positive or negative, Monte-Carlo simulations of neutron noise pose distinct challenges in terms of variance reduction. In this work we investigate two variance-reduction techniques, namely branchless collisions and weight cancellation, and probe their effectiveness for a benchmark con- figuration concerning the noise field induced by a pin with oscillating cross sections in a fuel assembly.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Millimeter-wave sensor image enhancement

Images from an airborne, scanning radiometer operating at a frequency of 98 GHz have been analyzed. The millimeter-wave images were obtained in 1985-1986 using the JPL millimeter-wave imaging sensor. The goal of this study was to enhance the information content of these images and make their interpretation easier. A visual-interpretative approach was used for information extraction from the images. This included application of nonlinear transform techniques for noise reduction and for color, contrast, and edge enhancement. Results of using the techniques on selected millimeter-wave images are discussed.

Wilson, William J.↗

Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias

This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

Clinical Trial↗

Aeronautical noise suppression at transonic Mach numbers

The measurement of wind tunnel background pressure fluctuations in a Ludwig Tube is discussed. The measurements are to provide improved unsteady aerodynamic data for the design of aeronautical vehicles. The preliminary results of the facility calibration are presented. The noise generation mechanisms are discussed. The ability of conducting short duration acoustic tests is demonstrated, and amplitude and frequency data are given. Techniques of noise reduction are included.

Mccanless, G. F., Jr.↗

Insights into the nature and control of rotor noise

The dynamics of four important farfield rotating blade noise sources are summarized and techniques for noise reduction are discussed. These four noise areas include the role of unsteady blade surface loads on rotational noise, the effect of turbulent inflow on the radiated broadband noise of an airfoil, the influence of the trailing vortex on impulsive noise and tail rotor noise, and the effect of blade geometry on high-speed impulsive noise. These noise mechanisms occur to varying degrees on both helicopter rotors and propellers. Considerable theoretical work was done in the area of high-speed impulsive noise resulting from the geometry of the rotating blade system. Both model and full-scale experimental correlation of helicopter and propeller high-speed noise are presented. The effect of blade number and airfoil thickness distribution in reducing the high-speed noise is shown.

Pegg, R. J.↗

Evaluation and Improvement of Eddy Current Position Sensors in Magnetically Suspended Flywheel Systems

Eddy current position sensor performance is evaluated for use in a high-speed flywheel development system. The flywheel utilizes a five axis active magnetic bearing system. The eddy current sensors are used for position feedback for the bearing controller. Measured characteristics include sensitivity to multiple target materials and susceptibility to noise from the magnetic bearings and from sensor-to-sensor crosstalk. Improvements in axial sensor configuration and techniques for noise reduction are described.

Dever, Timothy P.↗

Visualization of Subsurface Defects in Composites using a Focal Plane Array Infrared Camera

A technique for enhanced defect visualization in composites via transient thermography is presented in this paper. The effort targets automated defect map construction for multiple defects located in the observed area. Experimental data were collected on composite panels of different thickness with square inclusions and flat bottom holes of different depth and orientation. The time evolution of the thermal response and spatial thermal profiles are analyzed. The pattern generated by carbon fibers and the vignetting effect of the focal plane array camera make defect visualization difficult. An improvement of the defect visibility is made by the pulse phase technique and the spatial background treatment. The relationship between a size of a defect and its reconstructed image is analyzed as well. The image processing technique for noise reduction is discussed.

Plotnikov, Yuri A.↗

High-frequency ECG

The standard ECG is by convention limited to 0.05-150 Hz, but higher frequencies are also present in the ECG signal. With high-resolution technology, it is possible to record and analyze these higher frequencies. The highest amplitudes of the high-frequency components are found within the QRS complex. In past years, the term "high frequency", "high fidelity", and "wideband electrocardiography" have been used by several investigators to refer to the process of recording ECGs with an extended bandwidth of up to 1000 Hz. Several investigators have tried to analyze HF-QRS with the hope that additional features seen in the QRS complex would provide information enhancing the diagnostic value of the ECG. The development of computerized ECG-recording devices that made it possible to record ECG signals with high resolution in both time and amplitude, as well as better possibilities to store and process the signals digitally, offered new methods for analysis. Different techniques to extract the HF-QRS have been described. Several bandwidths and filter types have been applied for the extraction as well as different signal-averaging techniques for noise reduction. There is no standard method for acquiring and quantifying HF-QRS. The physiological mechanisms underlying HF-QRS are still not fully understood. One theory is that HF-QRS are related to the conduction velocity and the fragmentation of the depolarization wave in the myocardium. In a three-dimensional model of the ventricles with a fractal conduction system it was shown that high numbers of splitting branches are associated with HF-QRS. In this experiment, it was also shown that the changes seen in HF-QRS in patients with myocardial ischemia might be due to the slowing of the conduction velocity in the region of ischemia. This mechanism has been tested by Watanabe et al by infusing sodium channel blockers into the left anterior descending artery in dogs. In their study, 60 unipolar ECGs were recorded from the entire ventricular surface and were signal-averaged and filtered in the 30-250 Hz frequency range. The results showed that the decrease noted in the HF-QRS correlated linearly with the local conduction delay. The results suggest that HF-QRS is a potent indicator of disturbed local conduction. An alternative theory is that HF-QRS reflect the shape of the original electrocardiographic signal. Bennhagen et al showed that root mean square (RMS) voltage values of the depolarization signal correlate poorly with the signal amplitude but highly with the first and second derivatives, i.e. the velocity and the acceleration of the signal. It has also been suggested that the autonomic nervous system affects HF-QRS. For example, sitting up causes significant changes in HF-QRS in some leads compared to the supine position [Douglas et al., 2006]. Unpublished results indicate that familial dysautonomic patients (both vagal and sympathetic degeneration) have very little Reduced Amplitude Zones (RAZ) formation . Athletic individuals, especially elite athletes, who have vagally-mediated changes on the conventional ECG (i.e. early repolarization, bradycardia) have increased RAZ formation. Further electrophysiological studies are needed, however, to better understand the underlying mechanisms of HF-QRS. Several investigators have studied HF-QRS in different cardiac conditions, including acute myocardial ischemia and myocardial infarction (MI). However, in order for clinicians to confidently use HF-QRS as an adjunct to standard ECG, more knowledge about the characteristics of HF-QRS is needed.

Tragardh, Elin↗

Realization of Ultra-High Spectral Purity with the Opto-Electronic Oscillator

Recent results with the Opto-Electronic Oscillator (OEO) have led to the realization of very high spectral purity. Experimental results have produced a performance characterized by a noise as low as by -50 dBc/Hz at 10 Hz for a 10 GHz OEO. The unit was built in a compact package containing an integrated DFB laser and the modulator. This performance is significant because the oscillator is free running, and since the noise in an OEO is independent of the oscillation frequency, the same result can also be obtained at higher frequencies. The result also demonstrates that high frequency, high performance, low cost, and miniature OEO can be realized with the integrated photonic technology. We have also developed a novel carrier suppression technique to reduce the 1/f phase noise of the oscillator even further. The technique is based on the use of a long fiber delay, in place of the high Q cavity, to implement carrier suppression. Our preliminary experimental results indicate an extra 10 to 20 dB phase noise reduction of the OEO with this novel technique. Further noise reduction beyond this value is expected with improved circuit design and longer reference fiber.

Yao, Steve↗

Combining quantum noise reduction resources: A practical approach

Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. Here, we demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.

Optomechanics↗

On the signal-to-noise ratio in IUE high-dispersion spectra

An observational and data reduction technique for fixed pattern noise (FPN) and random noise (RN) in fully extracted IUE high-dispersion spectra is described in detail, along with actual empirical values of signal-to-noise ratio (S/N) achieved. A co-addition procedure, involving SWP and LWR cameras observations of the same spectrum at different positions in the image format, provides a basis to disentangle FPN from RN, allowing each average amplitude, within a given wavelength interval, to be estimated as a function of average flux number. Empirical curves, derived with the noise algorithm, make it possible to estimate the S/N in individual spectra at the wavelengths investigated. The average S/N at the continuum level in well-exposed stellar spectra varies from 10 to 20, for the orders analyzed, depending on position in the spectral format. The co-addition procedure yields an improvement in S/N by factors ranging from 2.3 to 2.9. Direct measurements of S/N in narrow, line-free wavelength intervals of individual and co-added spectra for weak-lined stars yield comparable, or in some cases somewhat higher, S/N values and improvement factors.

Leckrone, David S.↗

Noise environment reduction foam spheres in space

The advent of lightweight fairings for new spacecraft and the increased thrust of new launch vehicles have intensified the need for better techniques for predicting and for reducing the low frequency noise environment of spacecraft at liftoff. This paper presents a VAPEPS (VibroAcoustic Payload Environment Prediction System) parametrical analysis of the noise reduction of spacecraft fairings and explores a novel technique for increasing the low frequency noise reduction of lightweight fairing by approximately 10 dB.

Scharton, Terry↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reduction of noise in gyro outputs

Technique is described to reduce extraneous gyro output signals by using relatively inexpensive shrouds which do not increase power comsumption. Shrouds reduce noise by minimizing mass of gas spinning with rotor, reducing Reynolds number near rotor, and inducing laminar flow.

Kraus, G. M.↗

Prediction and reduction of rotor broadband noise

Prediction techniques which can be or have been applied to subsonic rotors, and methods for designing helicopter rotors for reduced broadband noise generation are summarized. It is shown how detailed physical models of the noise source can be used to identify approaches to noise control.

Hayden, R. E.↗

Measurements of Infrared and Acoustic Source Distributions in Jet Plumes

The aim of this investigation was to use the linear phased array (LPA) microphones and infrared (IR) imaging to study the effects of advanced nozzle-mixing techniques on jet noise reduction. Several full-scale engine nozzles were tested at varying power cycles with the linear phased array setup parallel to the jet axis. The array consisted of 16 sparsely distributed microphones. The phased array microphone measurements were taken at a distance of 51.0 ft (15.5 m) from the jet axis, and the results were used to obtain relative overall sound pressure levels from one nozzle design to the other. The IR imaging system was used to acquire real-time dynamic thermal patterns of the exhaust jet from the nozzles tested. The IR camera measured the IR radiation from the nozzle exit to a distance of six fan diameters (X/D(sub FAN) = 6), along the jet plume axis. The images confirmed the expected jet plume mixing intensity, and the phased array results showed the differences in sound pressure level with respect to nozzle configurations. The results show the effects of changes in configurations to the exit nozzles on both the flows mixing patterns and radiant energy dissipation patterns. By comparing the results from these two measurements, a relationship between noise reduction and core/bypass flow mixing is demonstrated.

Agboola, Femi A.↗

Mars Reconnaissance Orbiter Navigation During the Primary Science Phase

The Mars Reconnaissance Orbiter began science operations in November 2006, with a suite of seven instruments and investigations, some of which required navigation accuracies much better than previous Mars missions. This paper describes the driving performance requirements levied on Navigation and how well those requirements have been met thus far. Trending analyses that have a direct impact on the Navigation performance, such as atmospheric bias determination, are covered in detail, as well as dynamic models, estimation strategy, tracking data reduction techniques, and residual noise.

MRO↗