Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photonic Diagnostic Technique For Thin Photoactive Films

Photonic diagnostic technique developed for use in noninvasive, rapid evaluation of thin paraelectric/ferroelectric films. Method proves useful in basic research, on-line monitoring for quality control at any stage of fabrication, and development of novel optoelectronic systems. Used to predict imprint-prone memory cells, and to study time evolution of defects in ferroelectric memories during processing. Plays vital role in enabling high-density ferroelectric memory manufacturing. One potential application lies in use of photoresponse for nondestructive readout of polarization memory states in high-density, high-speed memory devices. In another application, extension of basic concept of method makes possible to develop specially tailored ferrocapacitor to act as programmable detector, wherein remanent polarization used to modulate photoresponse. Large arrays of such detectors useful in optoelectronic processing, computing, and communication.

Thakoor, Sarita↗

In Vivo Noninvasive Analysis of Human Forearm Muscle Function and Fatigue: Applications to EVA Operations and Training Maneuvers

Forearm muscle fatigue is one of the major limiting factors affecting endurance during performance of deep-space extravehicular activity (EVA) by crew members. Magnetic resonance (MR) provides in vivo noninvasive analysis of tissue level metabolism and fluid exchange dynamics in exercised forearm muscles through the monitoring of proton magnetic resonance imaging (MRI) and phosphorus magnetic resonance spectroscopy (P-31-MRS) parameter variations. Using a space glove box and EVA simulation protocols, we conducted a preliminary MRS/MRI study in a small group of human test subjects during submaximal exercise and recovery and following exhaustive exercise. In assessing simulated EVA-related muscle fatigue and function, this pilot study revealed substantial changes in the MR image longitudinal relaxation times (T2) as an indicator of specific muscle activation and proton flux as well as changes in spectral phosphocreatine-to-phosphate (PCr/Pi) levels as a function of tissue bioenergetic potential.

Fotedar, L. K.↗

Noninvasive Intracranial Pressure and Tissue Oxygen Measurements for Space and Earth

The paper discusses the following: Increasing intracranial pressure in humans during simulated microgravity. and near-infrared monitoring of model chronic compartment syndrome in exercising skeletal muscle. Compared to upright-seated posture, 0 deg. supine, 6 deg. HDT, and 15 deg. HDT produced TMD changes of 317 +/- 112, 403 +/- 114, and 474 +/- 112 n1 (means +/- S.E.), respectively. Furthermore, postural transitions from 0 deg. supine to 6 deg. HDT and from 6 deg. to 15 deg. HDT generated significant TMD changes (p less than 0.05). There was no hysteresis when postural transitions to HDT were compared to reciprocal transitions toward upright seated posture. Currently, diagnosis of chronic compartment syndrome (CCS) depends on measurement of intramuscular pressure by invasive catheterization. We hypothesized that this syndrome can be detected noninvasively by near-infrared (NIR) spectroscopy, which tracks variations in muscle hemoglobin/myoglobin oxygen saturation. CCS was simulated in the tibialis anterior muscle of 7 male and 3 female subjects by gradual inflation of a cuff placed around the leg to 40 mmHg during 14 minutes of cyclic isokinetic dorsiflexion exercise. On a separate day, subjects underwent the identical exercise protocol with no external compression. In both cases, tissue oxygenation (T(sub O2) was measured in the tibialis anterior by NIR spectroscopy and normalized to a percentage scale between baseline and a T(sub O2) nadir reached during exercise to ischemic exhaustion. Over the course of exercise, T(sub O2) declined at a rate of 1.4 +/- 0.3% per minute with model CCS, yet did not decrease during control exercise. Post-exercise recovery of T(sub O2) was slower with model CCS (2.5 +/- 0.6 min) than in control (1.3 +/- 0.2 min). These results demonstrate that NIR spectroscopy can detect muscle deoxygenation caused by pathologically elevated intramuscular pressure in exercising skeletal muscle. Consequently, this technique shows promise as a noninvasive diagnostic tool for CCS.

Hargens, A. R.↗

Novel Approaches to Cellular Transplantation from the US Space Program

Research in the treatment of type I diabetes is entering a new era that takes advantage of our knowledge in an ever increasing variety of scientific disciplines. Some may originate from very diverse sources, one of which is the Space Program at National Aeronautics and Space Administration (NASA). The Space Program contributes to diabetes-related research in several treatment modalities. As an ongoing effort for medical monitoring of personnel involved in space exploration activities NASA and the extramural scientific community investigate strategies for noninvasive estimation of blood glucose levels. Part of the effort in the space protein crystal growth program is high-resolution structural analysis insulin as a means to better understand the interaction with its receptor and with host immune components and as a basis for rational design of a "better" insulin molecule. The Space Program is also developing laser technology for potential early cataract detection as well as a noninvasive analyses for addressing preclinical diabetic retinopathy. Finally, NASA developed an exciting cell culture system that affords some unique advantages in the propagation and maintenance of mammalian cells in vitro. The cell culture system was originally designed to maintain cell suspensions with a minimum of hydrodynamic and mechanical sheer while awaiting launch into microgravity. Currently the commercially available NASA bioreactor (Synthecon, Inc., Houston, TX) is used as a research tool in basic and applied cell biology. In recent years there is continued strong interest in cellular transplantation as treatment for type I diabetes. The advantages are the potential for successful long-term amelioration and a minimum risk for morbidity in the event of rejection of the transplanted cells. The pathway to successful application of this strategy is accompanied by several substantial hurdles: (1) isolation and propagation of a suitable uniform donor cell population; (2) management of host immune rejection; (3) protection from the autoimmune component of the disease; and (4) anatomic placement of the engrafted cells that permits timely response to blood sugar levels as well as effective release and deployment of insulin. Bioreactor technology may provide some critical advances for surmounting some of these scientific hurdles. The NASA bioreactor is a horizontally rotating cylinder that is completely filled with culture medium. Gaseous exchange is maintained by a concentric cylinder of permeable silicon. In slow rotation (15-25 rpm) particles of small mass such as cells and tissue aggregates remain suspended in the rotating body of fluid. This novel approach suspends cells without stirring thus, allowing objects of different size mass to colocate and interact in a very low shear environment. In fact, analysis of the forces acting on individual cells in the rotating bioreactor reveals that the cells are continuously falling through the fluid medium. The conditions in the bioreactor permit assembly of cells into aggregates. three-dimensional tissue growth, synthesis of intercellular matrix,10 differentiation, and some sinusoid formations that may serve as a surrogate vasculature for larger tissue segments.

Pellis, Neal R.↗

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe↗

Optical distributed sensors for feedback control: Characterization of photorefractive resonator

The aim of the project was to explore, define, and assess the possibilities of optical distributed sensing for feedback control. This type of sensor, which may have some impacts in the dynamic control of deformable structures and the monitoring of small displacements, can be divided into data acquisition, data processing, and control design. Analogue optical techniques, because they are noninvasive and afford massive parallelism may play a significant role in the acquisition and the preprocessing of the data for such a sensor. Assessing these possibilities was the aim of the first stage of this project. The scope of the proposed research was limited to: (1) the characterization of photorefractive resonators and the assessment of their possible use as a distributed optical processing element; and (2) the design of a control system utilizing signals from distributed sensors. The results include a numerical and experimental study of the resonator below threshold, an experimental study of the effect of the resonator's transverse confinement on its dynamics above threshold, a numerical study of the resonator above threshold using a modal expansion approach, and the experimental test of this model. A detailed account of each investigation, including methodology and analysis of the results are also included along with reprints of published and submitted papers.

Indebetouw, Guy↗

Noninvasive Sensor for Measuring Muscle Metabolism During Exercise

The measurement of oxygen uptake (VO2) and lactate threshold (LT) are utilized to assess changes in aerobic capacity and the efficacy of exercise countermeasures in astronauts. During extravehicular activity (EVA), real-time knowledge of VO2 and relative work intensity can be used to monitor crew activity levels and organize tasks to reduce the cumulative effects of fatigue. Currently VO2 and LT are determined with complicated measurement techniques that require sampling of expired ventilatory gases, which may not be accurate in enclosed, oxygen-rich environments such as the EVA suit. The UMMS team has developed a novel near infrared spectroscopic (NIRS) system which noninvasively, simultaneously and continuously measures muscle oxygen tension, oxygen saturation, pH (pHm), and hematocrit from a small sensor placed on the leg. This system is unique in that it allows accurate, absolute measurement of these parameters in the thigh muscle by correcting spectra for the interference from skin pigment and fat. These parameters can be used to estimate VO2 and LT. A preliminary evaluation of the system s capabilities was performed in the NASA JSC Exercise Physiology Lab.

Soller, B. R.↗

Southwest Research Institute assistance to NASA in biomedical areas of the technology

Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

Culclasure, D. F.↗

Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts: A Case-Based Discussion

Introduction: Intracranial pressure (ICP) elevation has been inferred or documented in a number of space crewmembers. Recent advances in noninvasive imaging technology offer new possibilities for ICP assessment. Most International Space Station (ISS) partner agencies have adopted a battery of occupational health monitoring tests including magnetic resonance imaging (MRI) pre- and postflight, and high-resolution sonography of the orbital structures in all mission phases including during flight. We hypothesize that joint consideration of data from the two techniques has the potential to improve quality and continuity of crewmember monitoring and care. Methods: Specially designed MRI and sonographic protocols were used to image eyes and optic nerves (ON) including the meningeal sheaths. Specific crewmembers multi-modality imaging data were analyzed to identify points of mutual validation as well as unique features of complementary nature. Results and Conclusion: Magnetic resonance imaging (MRI) and high-resolution sonography are both tomographic methods, however images obtained by the two modalities are based on different physical phenomena and use different acquisition principles. Consideration of the images acquired by these two modalities allows cross-validating findings related to the volume and fluid content of the ON subarachnoid space, shape of the globe, and other anatomical features of the orbit. Each of the imaging modalities also has unique advantages, making them complementary techniques.

Sargsyan, Ashot E.↗

Current concepts in the pathophysiology, evaluation, and diagnosis of compartment syndrome

This article reviews present knowledge of the pathophysiology and diagnosis of acute compartment syndromes. Recent results using compression of legs in normal volunteers provide objective data concerning local pressure thresholds for neuromuscular dysfunction in the anterior compartment. Results with this model indicate that a progression of neuromuscular deficits occurs when IMP increases to within 35 to 40 mm Hg of diastolic blood pressure. These findings provide useful information on the diagnosis and compression thresholds for acute compartment syndromes. Time factors are also important, however, and usually are incompletely known in most cases of acute compartment syndrome. Although the slit catheter is a very good technique for monitoring IMP during rest, these catheters and their associated extracorporeal transducer systems are not ideal. Recently developed miniature transducer-tipped catheters and, perhaps, future development of noninvasive techniques may provide accurate recordings of IMP in patients with acute compartment syndromes.

NASA Discipline Cardiopulmonary↗

Near-Infrared Monitoring of Model Chronic Compartment Syndrome In Exercising Skeletal Muscle

Chronic compartment syndrome (CCS) is characterized by muscle ischemia, usually in the anterior oompartment of the leg, caused by high intramuscular pressure during exercise. Dual-wave near-infrared (NIR) spectroscopy is an optical technique that allows noninvasive tracking of variations in muscle tissue oxygenation (Chance et al., 1988). We hypothesized that with a model CCS, muscle tissue oxygenation will show a greater decline during exercise and a slower recovery post-exercise than under normal conditions.

Hargens, Alan R.↗

Measuring Intracranial Pressure And Volume Noninvasively

Ultrasonic technique eliminates need to drill into brain cavity. Intracranial dynamics instrument probes cranium ultrasonically to obtain data for determination of intracranial pressure (ICP) and pressure-volume index (PVI). Instrument determines sensitivity of skull to changes in pressure and by use of mechanical device to exert external calibrated pressure on skull. By monitoring volume of blood flowing into jugular vein, one determines change of volume of blood in cranial system. By measuring response of skull to increasing pressure (where pressure increased by tilting patient known amount) and by using cranial blood pressure, one determines intial pressure in cerebrospinal fluid. Once PVI determined, ICP determined.

Cantrell, John H.↗

The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

Laing, R. A.↗

Development of a Multi-Channel, High Frequency QRS Electrocardiograph

With the advent of the ISS era and the potential requirement for increased cardiovascular monitoring of crewmembers during extended EVAs, NASA flight surgeons would stand to benefit from an evolving technology that allows for a more rapid diagnosis of myocardial ischemia compared to standard electrocardiography. Similarly, during the astronaut selection process, NASA flight surgeons and other physicians would also stand to benefit from a completely noninvasive technology that, either at rest or during maximal exercise tests, is more sensitive than standard ECG in identifying the presence of ischemia. Perhaps most importantly, practicing cardiologists and emergency medicine physicians could greatly benefit from such a device as it could augment (or even replace) standard electrocardiography in settings where the rapid diagnosis of myocardial ischemia (or the lack thereof) is required for proper clinical decision-making. A multi-channel, high-frequency QRS electrocardiograph is currently under development in the Life Sciences Research Laboratories at JSC. Specifically the project consisted of writing software code, some of which contained specially-designed digital filters, which will be incorporated into an existing commercial software program that is already designed to collect, plot and analyze conventional 12-lead ECG signals on a desktop, portable or palm PC. The software will derive the high-frequency QRS signals, which will be analyzed (in numerous ways) and plotted alongside of the conventional ECG signals, giving the PC-viewing clinician advanced diagnostic information that has never been available previously in all 12 ECG leads simultaneously. After the hardware and software for the advanced digital ECG monitor have been fully integrated, plans are to use the monitor to begin clinical studies both on healthy subjects and on patients with known coronary artery disease in both the outpatient and hospital settings. The ultimate goal is to get the technology out into the clinical world, where it has the potential to save lives.

DePalma, Jude L.↗

Frequency Domain Functional Near-Infrared Spectrometer (fNIRS) for Crew State Monitoring

A frequency domain functional near-infrared spectrometer (fNIRS) and accompanying software have been developed by the NASA Glenn Research Center as part of the Airspace Operations and Safety Program (AOSP) Technologies for Airplane State Awareness (TASA)—SE211 Crew State Monitoring (CSM) Project. The goal of CSM was to develop a suite of instruments to measure the cognitive state of operators while performing operational activities. The fNIRS was one of the instruments intended for the CSM, developed to measure changes in oxygen levels in the brain noninvasively.

Jeffrey R Mackey↗

Applications in Bioastronautics and Bioinformatics: Early Radiation Cataracts Detected by Noninvasive, Quantitative, and Remote Means

Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).

Ansari, Rafat R.↗

Measurement of resistance to solute transport across surfactant-laden interfaces using a Fluorescence Recovery After Photobleaching (FRAP) technique

A noninvasive fluorescence recovery after photobleaching (FRAP) technique is under development to measure interfacial transport in two phase systems without disturbing the interface. The concentration profiles of a probe solute are measured in both sides of the interface by argon-ion laser, and the system relaxation is then monitored by a microscope-mounted CCD camera.

Browne, Edward P.↗

Investigating a Firn Aquifer near Helheim Glacier (South-Eastern Greenland) with Magnetic Resonance Soundings and Ground-Penetrating Radar

We apply the magnetic resonance sounding (MRS) method to investigate a firn aquifer in the south-east region of the Greenland ice sheet. Our study aims to delineate and estimate the volume of the recently discovered water stored within the firn (compacted snow) that remains liquid throughout the year. We develop and test successfully amethodology for joint use of MRS and ground-penetrating radar (GPR). This noninvasive geophysical approach is particularly well-adapted to glacier conditions and has a promising future for in situ investigation of water distribution in glaciers. At our field site, MRS showed an aquifer located at variable depths between 20 and 30 m beneath the ice-sheet surface. At the monitoring site, both MRS and GPR show an increase in the water volume stored between April 2015 and July 2016. MRS estimates suggest that the volume increased by approximately 28%.

meltwater↗