Novel methods for ultrahigh velocity resolution in molecular beams for inelastic scattering dynamics and chemical reactions
Forty minute invited presentation at the Cold Molecules and Cold Chemistry workshop.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Forty minute invited presentation at the Cold Molecules and Cold Chemistry workshop.
This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.
Oscillation detection and mitigation is a crucial aspect of reliable power system operation. Several transmission system operators and reliability coordinators use the RMS-energy method of oscillation detection, but the process of setting thresholds is time and labor intensive. The current industry practice in the United States is to set thresholds based on the RMS-energy's value during ambient conditions, which can often lead to nuisance alarms that require thresholds to be manually retuned. In this paper, we propose a method for setting RMS-energy thresholds that directly accounts for oscillation amplitudes specified by the user. A theoretical analysis of the statistical properties of the RMS-energy incorporates these user-specified amplitudes, resulting in thresholds that reliably detect oscillations of interest while avoiding nuisance alarms. Theoretical results are validated with simulated measurements and the real-world practicality of the method is established with publicly available field-measured data from the Grid Event Signature Library.
This work presents the use of a high-fidelity neural network surrogate model within a Modular Optimization Framework for treatment of crud deposition as a constraint within light-water reactor core loading pattern optimization. The neural network was utilized for the treatment of crud constraints within the context of an advanced genetic algorithm applied to the core design problem. This proof-of-concept study shows that loading pattern optimization aided by a neural network surrogate model can optimize the manner in which crud distributes within a nuclear reactor without impacting operational parameters such as enrichment or cycle length. Several analysis methods were investigated. Analysis found that the surrogate model and genetic algorithm successfully minimized the deviation from a uniform crud distribution against a population of solutions from a reference optimization in which the crud distribution was not optimized. Strong evidence is presented that shows boron deposition in crud can be optimized through the loading pattern. This proof-of-concept study shows that the methods employed provide a powerful tool for mitigating the effects of crud deposition in nuclear reactors.
New method using temperature differentiation to determine energy loss factors for slow electrons in hot gases
Propellant low temperature preignition reactions during simulated engine shutdown conditions, discussing IR spectroscopic observation method
A method for aligning the transmitter and receiver telescopes of a lidar is proposed which involves the use of a small high-quality corner tube reflector placed immediately in front of the transmitter in such a way that a small fraction of the transmitted radiation is reflected to the receiver. The reflected radiation is brought to a focus in a focal plane where it appears as a small red dot and is superimposed on the image of the distant scene. The dot and the target appear in the same plane and may be brought to coincidence by moving the transmitter-receiver pair together until the image of the target falls on the red dot. The alignment is concluded by imaging the red dot onto an IR detector.
A simple method is described for substantially reducing the amplitude of interference fringes that limit the sensitivities of tunable-laser high-resolution absorption spectrometers. A lead-salt diode laser operating in the 7-micron region is used with a single Brewster-plate spoiler to reduce the fringe amplitude by a factor of 30 and also to allow the detection of absorptances 0.001 percent in a single laser scan without subtraction techniques, without complex frequency modulation, and without distortion of the molecular line-shape signals. Application to multipass-cell spectrometers is described.
A method is described for calculation of the radiation pattern of large aperture antennas. A piece-wise linear approximation of the aperture field using overlapping pyramidal basis functions allows the radiation pattern of an aperture antenna to be calculated as though it were a two-dimensional array. The calculation of radiation pattern data versus theta and phi, suitable for 3-D or contour plot algorithms, is achieved by locating the array in the yz-plane and performing a summation over the aperture field data sampled on a square grid. A FORTRAN subroutine is provided for performing radiation pattern calculations. Numerical results are included to demonstrate the accuracy and convergence of the method. These numerical results indicate that typical accuracies of + or - 0.1 dB for Directivity, + or - dB for the 1st Sidelobe Level, and + - 2dB for the 2nd Sidelobe Level can be obtained with an aperture grid of 45x45 points and requires approximately 0.02 seconds CPU time per far-field data point on a VAX 11/750 with a floating point accelerator.
The effect on a plane subsonic turbulent jet of controlled high-amplitude periodic oscillations applied to the nozzle is investigated experimentally. A variable-speed motor and a gear-cam mechanism are used to make the lips of the nozzle reciprocate in opposite directions at the desired frequency. Velocity profiles, flow visualizations, and pressure-signal traces are presented and analyzed in detail. The complex vortex processes involved in the oscillation-induced spreading and entrainment of the jet are explored, and a critical Strouhal number for vortex formation and amplification is determined. The oscillation technique is found to augment the thrust of a jet/duct-diffuser configuration by a factor of 1.20; the thrust increases with oscillation frequency up to 20 Hz and remains constant if the frequency is further increased.
A new and systematic approach for producing polymer microspheres has been demonstrated. The membrane of the microsphere is formed by immersing the polyanionic droplet into a collapsing annular sheet, which is made of another polycation polymer solution. This method minimizes the impact force during the time when the chemical reaction takes place, hence eliminating the shortcomings of the current encapsulation techniques. The results of this study show the feasibility of this method for mass production of microcapsules.
A guanidine-based vehicle was developed to deposit precious metal coatings on surfaces known to be difficult to coat. To demonstrate this method, a platinum coating was deposited on alumina fibers using a guanidine-platinum solution. X-ray diffraction confirmed that the only species present in the coating was platinum and that all of the carbon species had been removed upon heat treatment. SEM results showed that some porosity was present but that the coatings uniformly covered the fiber surface and adhered well to the finer.
One of the major hindrances to expansion of the rotorcraft market is the high-amplitude noise they produce, especially during low-speed descent, where blade-vortex interactions frequently occur. In an attempt to reduce the noise levels caused by blade-vortex interactions, the flip-tip rotor blade concept was devised. The flip-tip rotor increases the miss distance between the shed vortices and the rotor blades, reducing BVI noise. The distance is increased by rotating an outboard portion of the rotor tip either up or down depending on the flight condition. The proposed plan for the grant consisted of a computational simulation of the rotor aerodynamics and its wake geometry to determine the effectiveness of the concept, coupled with a series of wind tunnel experiments exploring the value of the device and validating the computer model. The computational model did in fact show that the miss distance could be increased, giving a measure of the effectiveness of the flip-tip rotor. However, the wind experiments were not able to be conducted. Increased outside demand for the 7'x lO' wind tunnel at NASA Ames and low priority at Ames for this project forced numerous postponements of the tests, eventually pushing the tests beyond the life of the grant. A design for the rotor blades to be tested in the wind tunnel was completed and an analysis of the strength of the model blades based on predicted loads, including dynamic forces, was done.
Material constitutive properties, which describe the mechanical behavior of a material under loading, are vital to the design and implementation of engineering materials. For homogeneous materials, the standard process for determining these properties is the tensile test, which is used to measure the material stress-strain response. However, a majority of the applications for engineering materials involve the use of heterogeneous materials and structures (i.e. alloys, welded components) that exhibit heterogeneity on a global or local level. Regardless of the scale of heterogeneity, the overall response of the material or structure is dependent on the response of each of the constituents. Therefore, in order to produce materials and structures that perform in the best possible manner, the properties of the constituents that make up the heterogeneous material must be thoroughly examined. When materials exhibit heterogeneity on a local level, such as in alloys or particle/matrix composites, they are often treated as statistically homogenous and the resulting 'effective' properties may be determined through homogenization techniques. In the case of globally heterogeneous materials, such as weldments, the standard tensile test provides the global response but no information on what is Occurring locally within the different constituents. This information is necessary to improve the material processing as well as the end product.
Over the 70-year evolution of the helicopter, man's understanding of vibration control has greatly increased. However, in spite of the increased performance, the extent of helicopter vibration problems has not significantly diminished. Crew vibration and noise remains important factors in the design of all current helicopters. With more complex and critical demands being placed on aircrews, it is essential that vibration and noise not impair their performance. A major source of helicopter cabin noise (which has been measured at a sound pressure level of over 100 dB) is the gearbox. Reduction of this noise has been a goal of NASA and the U.S. Army. Gear mesh noise is typically in the frequency range of 1000 to 3000 Hz, a range important for speech. A requirement for U.S. Army/NASA Advanced Rotorcraft Transmission project has been a 10-dB reduction compared to current designs. A combined analytical/experimental effort has been underway, since the end of the 80's, to study effects of design parameters on noise production. The noise generated by the gear mesh can be transmitted to the surrounding media through the bearings that support the gear shaft. Therefore, the use of fluid film bearings instead of rolling element bearings could reduce the transmission noise by 10 dB. In addition, the fluid film bearings that support the gear shaft can change the dynamics of the gear assembly by providing damping to the system and by being softer than rolling element bearings. Wave bearings can attenuate, and filter, the noise generated by a machine component due to the dynamic stiffness and damping coefficients. The attenuation ratio could be as large as 35-40 dB. The noise components at higher frequencies than a synchronous frequency can be almost eliminated.
Detection of extra-solar, and especially terrestrial-like planets, using coronagraphy requires an extremely high level of wavefront correction. For example, the study of Woodruff et al. (2002) has shown that phase uniformity of order 10(exp -4)lambda(rms) must be achieved over the critical range of spatial frequencies to produce the approx. 10(exp 10) contrast needed for the Terrestrial Planet Finder (TPF) mission. Correction of wavefront phase errors to this level may be accomplished by using a very high precision deformable mirror (DM). However, not only phase but also amplitude uniformity of the same scale (10(exp -4)) and over the same spatial frequency range must be simultaneously obtained to remove all residual speckle in the image plane. We present a design for producing simultaneous wavefront phase and amplitude uniformity to high levels from an input wavefront of modest quality. The design uses a dual Michelson interferometer arrangement incorporating two DMs and a single, fixed mirror (all at pupils) and two beamsplitters: one with unequal (asymmetric) beam splitting and one with symmetric beam splitting. This design allows high precision correction of both phase and amplitude using DMs with relatively coarse steps, is substantially achromatic and permits a simple correction algorithm.
Detection of extra-solar, and especially terrestrial-like planets, using coronagraphy requires an extremely high level of wavefront correction. For example, the study of Woodruff et al. (2002) has shown that phase uniformity of order approximately 1e-4 waves(rms) must be achieved over the critical range of spatial frequencies to produce the approximately le10 contrast needed for the Terrestrial Planet Finder (TPF) mission. Correction of wavefront phase errors to this level may be accomplished by using a very high precision deformable mirror (DM). However, not only phase but also amplitude uniformity of the same scale (le-4) and over the same spatial frequency range must be simultaneously obtained to remove all residual speckle in the image plane. We present a design for producing simultaneous wavefront phase and amplitude uniformity to high levels from an input wavefront of lower quality. The design uses a dual Michelson interferometer arrangement incorporating two DMs and a single, fixed mirror (all at pupils) and two beamsplitters: one with unequal (asymmetric) beam splitting and one with symmetric beam splitting. This design allows high precision correction of both phase and amplitude using DMs with relatively coarse steps, and permits a simple correction algorithm.
To further validate the Pellet Gastric Emptying Test (PGET) as a marker of gastric emptying, a randomized, four-way crossover study was conducted with 12 healthy subjects. The study consisted of oral co-administration of enteric coated caffeine (CAFF) and acetaminophen (APAP) pellets in four treatment phases: Same Size (100 kcal), Fasted, Small Liquid Meal (100 kcal), and Standard Meal (847 kcal). The time of first appearance of measurable drug marker in plasma, t(initial), was taken as the emptying time for the markers. Co-administration of same size enteric coated pellets of CAFF and APAP (0.7 mm in diameter) revealed no statistically significant differences in t(initial) values indicating that emptying was dependent only on size and not on chemical make-up of the pellets. Co-administration of different size pellets indicated that the smaller 0.7-mm diameter (CAFF) pellets were emptied and absorbed significantly earlier than the larger 3.6-mm diameter (APAP) pellets with both the Small Liquid Meal (by 35 min) and the Standard Meal (by 33 min) (P<0.05). The differences in emptying of the pellets were not significant in the Fasted Phase. The results suggest that the pellet gastric emptying test could prove useful in monitoring changes in transit times in the fasted and fed states and their impact on drug absorption.