Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.
This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV dc to a future polarized beam photogun, to be designed for operating at 350kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.
Research conducted by the Electric Power Research Institute (EPRI) and other research institutions have concluded that water-trees are one of the leading degradation mechanisms that contribute to the loss of dielectric insulation strength in medium-voltage cable insulating materials in wet or submerged environments. The electrochemical reactions are caused by the combined effect of water presence and relatively high electrical stress. Records of cable failures provided by the licensees in response to Generic Letter (GL) 2007-01 (NRC 2007) have called into question the reliability of medium voltage cables in wetted or submerged environments. EPRI’s dissipation factor or Tan Delta testing guidelines and acceptance criteria have been adopted by most nuclear power plant operators as the primary tool for condition monitoring of medium voltage cables in wet or submerged environments. EPRI has been collecting member data since late 2009 to analyze and provide feedback to members, validate the EPRI-developed acceptance criteria guidelines, support analysis of test results, recommend appropriate actions for the "action required" category, and gather candidate cables for EPRI-sponsored forensic research on causes for insulation degradation. EPRI has collected data from 37 nuclear sites, which represent 44 operating units. The test results have been organized by insulation type, such as cross-linked polyethylene (XLPE); butyl rubber; black, pink, and brown ethylene-propylene rubber (EPR); and compact insulation (black and pink EPR)1. The data have been analyzed, and follow-up information was obtained from members for “action required” test results. EPRI has also performed correlations between Tan Delta tests and the information gathered under the EPRI forensic research on medium-voltage cables. In addition, EPRI has developed guidance by cable insulation type on how to systematically analyze Tan Delta test results. The analysis described here reviewed the two primary EPRI reports (EPRI 3002000557 and EPRI 3002005321) as well as two precedent EPRI reports (EPRI 1028262 and EPRI 1021070) that were cited in the primary reports. The principal results and conclusions from the project analyses are provided.
The National Nuclear Security Administration’s (NNSA) Office of Nonproliferation and Arms Control (NA-24) is evaluating Wide-Area Environmental Sampling (WAES) as an additional safeguards verification tool for the International Atomic Energy Agency to detect undeclared nuclear activities. The NNSA is evaluating strategies for conducting a generic WAES campaign, the cost of a WAES campaign, and the effect of technological advancements that have occurred since the last major WAES review in 1999. Until now, the NNSA effort has focused on tabletop exercises (TTXs) in which high-performance computing allows for advanced modeling and simulation efforts to be applied to the WAES question. Although the modeling and simulations used in the TTXs are extremely valuable, field campaigns are still needed to validate the assumptions that underpin the models and the modeling process itself. During a 7 week period beginning in May 2023 and ending in June 2023, which included 4 weeks of active field collections, a multilaboratory team conducted its first in-field validation exercise. Prior to the in-field exercise, abbreviated TTXs were conducted to estimate the performance of all collection systems to be used during the field test. These TTXs guided the selection of materials to be released and the placement of the collection system. Based on these determinations, materials were procured to use in the field test, and an injection/release system was designed, built, and installed at the test facility. Background samples were collected during weeks one and four, and environmental collections against active releases were conducted during weeks two and three. The goals of this validation exercise included a demonstration of (1) the ability to provide controlled releases of particulates of surrogate materials, (2) the fielding and operation of collection systems (including deposition and active air collectors), and (3) the flexibility to revise equipment and campaign plans in the field. This paper presents the results and preliminary conclusions for this initial validation test. Based on these results, subsequent field campaigns are anticipated and will include the addition of other released materials.
Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.
Significant cost savings can be made if electrical cables can be replaced by wireless technology in current Nuclear Power Plants (NPP) and in advance reactor designs. Wireless technology can also provide in-core opportunities by significantly reducing the number of penetrations in the pressure vessel, cost and complexity of sensor installation and by increasing the efficiency of current and advanced reactors. Unlike other deployment scenarios for an industrial environment, operators need to have centralized control over all the networks. Centralized control will reduce implementation costs, provide single point control and enable monitoring of network devices, improve security, and enhance connectivity. Micro-sensors that can simultaneously monitor temperature and pressure within a fuel rod inside nuclear reactors will enable preventative actions during abnormal operating conditions. This ability could avert accidents and enable the expedient development of accident tolerant fuels. A novel micro-sensor suite (~ mm) to simultaneously measure multiple parameters such as temperature, strain, pressure, and neutron/gamma flux inside a fuel rod is being developed for use in reactors. The necessary communication architecture is also being developed to transmit measurement signals from the core to the plant's data cloud or control room. A three three-tier strategy has been developed to support wireless transmission of in-core measurements to the control room or to a secure cloud platform for control, analytics, and decision-making purposes. 1. In-core: data signal from in-core to outside of the pressure vessel within the containment building 2. Containment building: data signal from inside to the outside of the containment building and into the balance of the plant network 3. Balance of the plant network: information transmitted to the data cloud and control room This plan presents a wireless sensing and communication system for use within a reactor core and elsewhere. The communication technology is advantageous to compensate for network equipment failures and adverse data transmission conditions. Wireless technology will significantly increase the resiliency of the plants network system. The wireless system naturally provides multiple transmission path capability and data redundancy.
To address an important need for Nuclear Power Plants (NPPs) to significantly reduce the amount of the required cables for sensor data communications, this Phase I SBIR effort successfully developed and demonstrated a novel low-cost proof-of-concept prototype of a secure wireless sensor network backbone communications system. This system combines commercially available low power, low cost XBEE wireless communications network and passive (battery-free) Radio Frequency Identification (RFID) systems to report individual sensor data and their location through the containment wall for rapid response to anomalies in nuclear facilities. This WIreless Sensing and Locating (WISLO) system network architecture allows non-intrusive wireless collection of sensor data with the sensor’s accurate location information from inside of the instrumentation or containment area with minimal need for power sources. The multi-node sensor data in the containment area is wirelessly transmitted to outside through the metal reinforced concrete walls without the need for any batteries. The WISLO system could be readily used in current reactor fleet and future advanced reactors, as well as in small modular reactors (SMR). The WISLO system is the first dual frequency battery-free trough the wall communications backbone system developed specifically for use in nuclear power plants. It not only can modernize the sensor monitoring practices in the existing reactor fleet, but also offers a secure, low-cost solution to advanced reactors and SMRs by removing cables and issues related to them such as cable integrity, reporting delays, and installation and maintenance costs. The intent is to improve process safety, reliability, efficiency, and cost effectiveness to the monitoring and maintenance process in current and future plants. As we address the next productization and manufacturing capabilities in the next phase, this system will serve the needs of many commercial and government applications in remote monitoring of sensor data that demand battery-free transmission of sensor data such as Internet-of-Things (IOT).
The objective of this work was to develop a first phase consensus roadmap for condition-based qualification (CBQ) of electrical cables. With CBQ, qualification of Class 1E electrical cables moves from a time-based approach to a condition-based approach, which is anticipated to be safer in terms of reliability and conservatism, and more cost effective in the long run. However, due to barriers, the CBQ approach has not yet been adopted by U.S. nuclear power plants (NPPs). Based upon a review of current work evaluating CBQ, the limitation of available condition monitoring technology seems to be the largest barrier. The importance of condition monitoring, or more specifically selecting appropriate condition indicators, during CBQ cannot be understated. However, selecting appropriate condition indicators is challenged by techniques that are destructive and only evaluate cable degradation locally. Further, arguably, no one identified condition indicator fully establishes cable condition. Thus, additional work is necessary to evaluate potential condition indicators towards CBQ. In addition to the requirements of IEC/IEEE Std. 60780-323, ideal condition indicators should include a) both destructive and non-destructive approaches, b) both local and global measurements, c) real-time (i.e., online) monitoring that trends with degradation, d) enable correlation with qualified levels of degradation, and e) be established within a repository of condition indicators with applicable materials and/or components and their acceptance criteria. Additional work is needed in development of technology and methodology prior to adoption of CBQ, especially for extending qualified life of installed components. Education and early experience by the industry and regulators will be required for this change in approach as an alternative to re-analysis. A series of workshops that bring together stakeholders to identify and address gaps will be needed. The longstanding cooperative working group of cable researchers from the U.S. Department of Energy, the Electric Power Research Institute, and the Nuclear Regulatory Commission forms a valuable starting point for development of a consensus roadmap to condition-based qualification approach as a viable options for qualification of cable systems in U.S. light water reactors.
Explore the source record for details and available documents.
As advanced reactor concepts like small modular reactors (SMRs) progress towards design maturity and commercial deployment, it is important to assess their instrumentation and control (I&C) system sensors and cables to assure their safe, reliable, and efficient operation throughout their service lifetimes. The I&C system of any nuclear power plant (NPP) is the central nervous system of the plant and is made up of field devices such as sensors which are connected via cables to analog and/or digital systems. These systems are responsible for control and/or protection of the plant. The performance of I&C sensors and cables is dependent on several factors, including plant operating conditions. In particular, the plant operation can affect the static (accuracy) and dynamic (response) performance of the sensor, whereas the surrounding ambient environment can impact the remaining useful life of the cables, connectors, and other associated components within I&C sensor circuits.
The Deep Underground Neutrino Experiment (DUNE) at Fermilab is one the most challenging next-generation experiments in the field of neutrino physics. It will feature two detectors for a detailed study of neutrino oscillations using an unprecedentedly intense neutrino beam. The two detectors are a Near Detector located on the Fermilab site, 574 m away from the neutrino generation, and a Far Detector in South Dakota, 1300 km away. The Near Detector consists of three subdetectors, based on different technologies in order to achieve the best understanding of the neutrino beam. One key element of the Near Detector is a High Pressure Argon TPC surrounded by a calorimeter. This detector will need a 0.5 Tesla magnetic field transverse to the neutrino beam direction, with a 7 m diameter, 8 m long warm bore. A thin superconducting solenoid with a partial yoke, needed in order to minimise the amount of material along the path particles take crossing the different elements of the Near Detector is proposed. In this paper we present a detailed magnetic analysis and a preliminary study of the cooling, the cable and the mechanics for this magnet.
Second-generation high temperature superconductors (HTS) are available for producing >20 T at the magnet bore compared to 13–16 T for lower temperature superconducting (LTS) toroidal field magnets proposed in recent fusion energy systems studies (FESS) of Fusion Nuclear Science Facility (FNSF). HTS may enable higher fusion power density and smaller device size. High current density cables of multi-layered REBCO tapes have achieved >10 kA at 4–20 K operation in short sample tests for fusion. High current density cables are required for engineering design of FNSF to allow space for interior plasma components. High current density HTS magnets are particularly attractive in reducing the size of a fusion device, beneficial for compact tokamaks, due to their space constraints. Successful HTS magnet development may enable the design of smaller and cheaper fusion pilot plants with a mission of demonstrating net electricity. It may also offer significant cost and performance advantages in non-fusion applicants such as nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Furthermore, we developed HTS magnet design concepts for a compact FNSF radial build in order to define the coil size, winding pack mechanical loading and engineering requirements. Partnering with vendors in the US, PPPL is also testing high current cable prototypes aiming at enabling low cost cable technology toward 100 A/mm 2 engineering current density over the winding pack desired in high field model coil development for compact fusion pilot plants.
The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.