Search NASA⌕ Search

SEARCH · Search NASA

Results for “object positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Models of the strongly lensed quasar DES J0408-5354

We present gravitational lens models of the multiply imaged quasar DES J0408-5354, recently discovered in the Dark Energy Survey (DES) footprint, with the aim of interpreting its remarkable quad-like configuration. We first model the DES single-epoch $grizY$ images as a superposition of a lens galaxy and four point-like objects, obtaining spectral energy distributions (SEDs) and relative positions for the objects. Three of the point sources (A,B,D) have SEDs compatible with the discovery quasar spectra, while the faintest point-like image (G2/C) shows significant reddening and a `grey' dimming of $\approx0.8$mag. In order to understand the lens configuration, we fit different models to the relative positions of A,B,D. Models with just a single deflector predict a fourth image at the location of G2/C but considerably brighter and bluer. The addition of a small satellite galaxy ($R_{\rm E}\approx0.2$") in the lens plane near the position of G2/C suppresses the flux of the fourth image and can explain both the reddening and grey dimming. All models predict a main deflector with Einstein radius between $1.7"$ and $2.0",$ velocity dispersion $267-280$km/s and enclosed mass $\approx 6\times10^{11}M_{\odot},$ even though higher resolution imaging data are needed to break residual degeneracies in model parameters. The longest time-delay (B-A) is estimated as $\approx 85$ (resp. $\approx125$) days by models with (resp. without) a perturber near G2/C. The configuration and predicted time-delays of J0408-5354 make it an excellent target for follow-up aimed at understanding the source quasar host galaxy and substructure in the lens, and measuring cosmological parameters. We also discuss some lessons learnt from J0408-5354 on lensed quasar finding strategies, due to its chromaticity and morphology.

79 ASTRONOMY AND ASTROPHYSICS↗

Conductive trace interconnection tape

A conductive trace interconnect tape for use with a printed circuit board or a flexible circuit substrate comprises a top insulating layer, an electrically conductive layer, and a bottom insulating layer. The top insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on top of the conductive trace interconnect tape. The electrically conductive layer is positioned underneath the top insulating layer. The electrically conductive layer is formed from electrically conductive material and includes electrical interconnect traces, electrical component pads, or electrically conductive planar portions. The bottom insulating layer is positioned underneath the electrically conductive layer. The bottom insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on the printed circuit board or flexible circuit substrate.

Hatch, Stephen McGarry↗

Conductive trace interconnection tape

A conductive trace interconnect tape for use with a printed circuit board or a flexible circuit substrate comprises a top insulating layer, an electrically conductive layer, and a bottom insulating layer. The top insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on top of the conductive trace interconnect tape. The electrically conductive layer is positioned underneath the top insulating layer. The electrically conductive layer is formed from electrically conductive material and includes electrical interconnect traces, electrical component pads, or electrically conductive planar portions. The bottom insulating layer is positioned underneath the electrically conductive layer. The bottom insulating layer is formed from electrically insulating material and is configured to provide electrical isolation from electrically conductive objects that are positioned on the printed circuit board or flexible circuit substrate.

Hatch, Stephen McGarry↗

A spherical aberration-free microscopy system for live brain imaging

Highlights: • Deep-C is an automatic spherical aberration compensation system for in vivo imaging. • Deep-C is composed of ZlinC and Peak-C. • ZlinC coordinates the correction collar rotation and the Z-position of an objective. • Peak-C is a scanning algorithm processor for calculation of image contrast. • Deep-C allows quantitative, reproducible analysis of fine GFP-labeled structures. The high-resolution in vivo imaging of mouse brain for quantitative analysis of fine structures, such as dendritic spines, requires objectives with high numerical apertures (NAs) and long working distances (WDs). However, this imaging approach is often hampered by spherical aberration (SA) that results from the mismatch of refractive indices in the optical path and becomes more severe with increasing depth of target from the brain surface. Whereas a revolving objective correction collar has been designed to compensate SA, its adjustment requires manual operation and is inevitably accompanied by considerable focal shift, making it difficult to acquire the best image of a given fluorescent object. To solve the problems, we have created an objective-attached device and formulated a fast iterative algorithm for the realization of an automatic SA compensation system. The device coordinates the collar rotation and the Z-position of an objective, enabling correction collar adjustment while stably focusing on a target. The algorithm provides the best adjustment on the basis of the calculated contrast of acquired images. Together, they enable the system to compensate SA at a given depth. As proof of concept, we applied the SA compensation system to in vivo two-photon imaging with a 25 × water-immersion objective (NA, 1.05; WD, 2 mm). It effectively reduced SA regardless of location, allowing quantitative and reproducible analysis of fine structures of YFP-labeled neurons in the mouse cerebral cortical layers. Interestingly, although the cortical structure was optically heterogeneous along the z-axis, the refractive index of each layer could be assessed on the basis of the compensation degree. It was also possible to make fully corrected three-dimensional reconstructions of YFP-labeled neurons in live brain samples. Our SA compensation system, called Deep-C, is expected to bring out the best in all correction-collar-equipped objectives for imaging deep regions of heterogeneous tissues.

60 APPLIED LIFE SCIENCES↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Size and Shape Constraints of (486958) Arrokoth from Stellar Occultations

We present the results from four stellar occultations by (486958) Arrokoth, the flyby target of the New Horizons extended mission. Three of the four efforts led to positive detections of the body, and all constrained the presence of rings and other debris, finding none. Twenty-five mobile stations were deployed for 2017 June 3 and augmented by fixed telescopes. There were no positive detections from this effort. The event on 2017 July 10 was observed by the Stratospheric Observatory for Infrared Astronomy with one very short chord. Twenty-four deployed stations on 2017 July 17 resulted in five chords that clearly showed a complicated shape consistent with a contact binary with rough dimensions of 20 by 30 km for the overall outline. A visible albedo of 10% was derived from these data. Twenty-two systems were deployed for the fourth event on 2018 August 4 and resulted in two chords. The combination of the occultation data and the flyby results provides a significant refinement of the rotation period, now estimated to be 15.9380 ± 0.0005 hr. The occultation data also provided high-precision astrometric constraints on the position of the object that were crucial for supporting the navigation for the New Horizons flyby. This work demonstrates an effective method for obtaining detailed size and shape information and probing for rings and dust on distant Kuiper Belt objects as well as being an important source of positional data that can aid in spacecraft navigation that is particularly useful for small and distant bodies.

79 ASTRONOMY AND ASTROPHYSICS↗

The Development of a Parameterized Scatter Removal Algorithm for NMIS Imaging

Neutron radiography is a powerful investigative technique for analyzing the interior structure of an object. If the true attenuation of neutrons at each position in the object can be measured, the cross-sections can be computed using the exponential attenuation formula. However, scattered neutrons will contribute to the measured neutron flux and reduce the measured attenuation. The Nuclear Materials Identification System (NMIS) uses a time-tagged and electronically collimated DT neutron source to reduce this effect; however, some of the scattering component remains. This work used Monte Carlo simulations to calculate the scattering component for a variety of scenarios. The scattering for each scenario was fit using a Gaussian distribution to derive a point scatter function. These point scatter functions were used to develop a parameterized scatter removal algorithm that can calculate and remove the scattering component for a wide range of scenarios based on operator inputs. The process used to calculate the scatter functions and develop the scatter removal algorithm is discussed in detail. Examples of simulated and experimental measurements are used to test and validate the algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CORRELATIONS OF THE ARRIVAL DIRECTIONS OF ULTRA-HIGH ENERGY COSMIC RAYS WITH EXTRAGALACTIC OBJECTS AS OBSERVED BY THE TELESCOPE ARRAY EXPERIMENT

We search for correlations between the positions of extragalactic objects and the arrival directions of ultra-high energy cosmic rays (UHECRs) with primary energy E ≥ 40 EeV as observed by the surface detector array of the Telescope Array (TA) experiment during the first 40 months of operation. We examine several public astronomical object catalogs, including the Veron-Cetty and Veron catalog of active galactic nuclei. We count the number of TA events correlated with objects in each catalog as a function of three parameters: the maximum angular separation between a TA event and an object, the minimum energy of the events, and the maximum redshift of the objects. We determine the combination of these parameters that maximizes the correlations, and we calculate the probability of having the same levels of correlations from an isotropic distribution of UHECR arrival directions. No statistically significant correlations are found when penalties for scanning over the above parameters and for searching in several catalogs are taken into account.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanisms of Enhanced Antibacterial Activity by Reduced Chitosan-Intercalated Nontronite

Previous studies have documented the antibacterial activity of certain iron-containing clays. However, the repulsion between negatively charged bacteria and the clay surface makes this process inefficient. The objective of this study is to improve the bactericidal efficiency of clays by reversing their surface charge from negative to positive. To achieve this objective, here positively charged chitosan, a nontoxic and biodegradable polymer, was intercalated into nontronite NAu-2. Chitosan-intercalated NAu-2 (C-NAu-2) was chemically reduced to obtain reduced C-NAu-2 (rC-NAu-2). Relative to reduced nontronite (rNAu-2), the antibacterial activity of rC-NAu-2 is higher and more persistent over a pH range of 6–8. The close spatial association between positively charged rC-NAu-2 and negatively charged bacteria increases the chances of cell membrane attack by extracellular ROS, the influx of soluble Fe 2+ into the bacterial cell, and the yield of intracellular ROS. All these factors contribute to the enhanced antibacterial activity of rC-NAu-2. In contrast to rNAu-2 treated E. coli cells, where membrane damage and intracellular ROS/Fe accumulation are restricted to the polar regions, the close bacteria–clay association in rC-NAu-2 results in nonselective membrane damage and more uniform intracellular ROS/Fe distribution across whole bacterial cells. These results advance the antibacterial model by highlighting the importance of bacteria–clay interactions to the antibacterial activity of Fe-bearing clays.

59 BASIC BIOLOGICAL SCIENCES↗

Computational Imaging for Intelligence in Highly Scattering Aerosols (Final Report)

Natural and man-made degraded visual environments pose major threats to national security. The random scattering and absorption of light by tiny particles suspended in the air reduces situational awareness and causes unacceptable down-time for critical systems and operations. To improve the situation, we have developed several approaches to interpret the information contained within scattered light to enhance sensing and imaging in scattering media. These approaches were tested at the Sandia National Laboratory Fog Chamber facility and with tabletop fog chambers. Computationally efficient light transport models were developed and leveraged for computational sensing. The models are based on a weak angular dependence approximation to the Boltzmann or radiative transfer equation that appears to be applicable in both the moderate and highly scattering regimes. After the new model was experimentally validated, statistical approaches for detection, localization, and imaging of objects hidden in fog were developed and demonstrated. A binary hypothesis test and the Neyman-Pearson lemma provided the highest theoretically possible probability of detection for a specified false alarm rate and signal-to-noise ratio. Maximum likelihood estimation allowed estimation of the fog optical properties as well as the position, size, and reflection coefficient of an object in fog. A computational dehazing approach was implemented to reduce the effects of scatter on images, making object features more readily discernible. We have developed, characterized, and deployed a new Tabletop Fog Chamber capable of repeatably generating multiple unique fog-analogues for optical testing in degraded visual environments. We characterized this chamber using both optical and microphysical techniques. In doing so we have explored the ability of droplet nucleation theory to describe the aerosols generated within the chamber, as well as Mie scattering theory to describe the attenuation of light by said aerosols, and correlated the aerosol microphysics to optical properties such as transmission and meteorological optical range (MOR). This chamber has proved highly valuable and has supported multiple efforts inclusive to and exclusive of this LDRD project to test optics in degraded visual environments. Circularly polarized light has been found to maintain its polarization state better than linearly polarized light when propagating through fog. This was demonstrated experimentally in both the visible and short-wave infrared (SWIR) by imaging targets made of different commercially available retroreflective films. It was found that active circularly polarized imaging can increase contrast and range compared to linearly polarized imaging. We have completed an initial investigation of the capability for machine learning methods to reduce the effects of light scattering when imaging through fog. Previously acquired experimental long-wave images were used to train an autoencoder denoising architecture. Overfitting was found to be a problem because of lack of variability in the object type in this data set. The lessons learned were used to collect a well labeled dataset with much more variability using the Tabletop Fog Chamber that will be available for future studies. We have developed several new sensing methods using speckle intensity correlations. First, the ability to image moving objects in fog was shown, establishing that our unique speckle imaging method can be implemented in dynamic scattering media. Second, the speckle decorrelation over time was found to be sensitive to fog composition, implying extensions to fog characterization. Third, the ability to distinguish macroscopically identical objects on a far-subwavelength scale was demonstrated, suggesting numerous applications ranging from nanoscale defect detection to security. Fourth, we have shown the capability to simultaneously image and localize hidden objects, allowing the speckle imaging method to be effective without prior object positional information. Finally, an interferometric effect was presented that illustrates a new approach for analyzing speckle intensity correlations that may lead to more effective ways to localize and image moving objects. All of these results represent significant developments that challenge the limits of the application of speckle imaging and open important application spaces. A theory was developed and simulations were performed to assess the potential transverse resolution benefit of relative motion in structured illumination for radar systems. Results for a simplified radar system model indicate that significant resolution benefits are possible using data from scanning a structured beam over the target, with the use of appropriate signal processing.

58 GEOSCIENCES↗

Multi-frame moving object detection system

A plurality of remote sensing images of a scene are received. A potential target object can be identified in one of the images, wherein the target object has a low signal-to-noise ratio (SNR). A candidate motion path of the target object can be generated based upon the images. A predicted position of the target object along the candidate motion path is determined for each of the remote sensing images. An image chip is extracted from each of the images, where each image chip is centered about the predicted position of the target object in its corresponding image. A sum image chip is generated based upon the image chips. An indication that the potential target object is an actual object in the images is output based upon a value of a center pixel of the sum image chip.

Ma, Tian J.↗

Study of continuous-wave domain fluorescence diffuse optical tomography for quality control on agricultural produce

The importance of monitoring the quality of vegetables and fruits is prosperity by giving a competitive advantage for producer and providing a more healthy food for consumer. Diffuse Optical Tomography (DOT) is offering the possibility to detect the internal defects of the agricultural produce quality. Fluorescence diffuse optical tomography (FDOT) is the development of DOT, offering the possibilities to improve spatial resolution and to contrast image. The purpose of this research is to compare FDOT and DOT in forward analysis with continuous wave approach. The scattering and absorbing parameters of potatoes are used to represent the real condition. The object was illuminated by the NIR source from some positions on the boundary of object. A set of NIR detector are placed on the peripheral position of the object to measure the intensity of propagated or emitted light. In the simulation, we varied a condition of object then we analyzed the sensitivity of forward problem. The result of this study shows that FDOT has a better sensitivity than DOT and a better potential to monitor internal defects of agricultural produce because of the contrast value between optical and fluorescence properties of agricultural produce normal tissue and defects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE FIRST CONFIRMED MICROLENS IN A GLOBULAR CLUSTER

In 2000 July/August a microlensing event occurred at a distance of 2.'33 from the center of the globular cluster M22 (NGC 6656), observed against the dense stellar field of the Milky Way bulge. We have used the adaptive optics system NACO at the ESO Very Large Telescope to resolve the two objects that participated in the event: the lens and the source. The position of the objects measured in 2011 July is in agreement with the observed relative proper motion of M22 with respect to the background bulge stars. Based on the brightness of the microlens components we find that the source is a solar-type star located at a distance of 6.0 {+-} 1.5 kpc in the bulge, while the lens is a 0.18 {+-} 0.01 M{sub Sun} dwarf member of the globular cluster located at the known distance of 3.2 {+-} 0.2 kpc from the Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project was supported by National Institutes of Health grants R01 EB017095 and U01 EB017185 from the National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

Multi-hypothesis moving object detection system

A method and apparatus for analyzing a sequence of images. Signal-to-noise ratios are identified for potential tracks using a tree having hierarchies of nodes identifying potential positions for an object over a period of time and using the sequence of images. Each hierarchy in the hierarchies of nodes represents a time and the potential positions in the tree form the potential tracks for the object. A potential track is selected from the potential tracks as an established track for the object using the signal-to-noise ratios, and a detection of the object is reported.

47 OTHER INSTRUMENTATION↗

Optical contact micrometer

Certain examples provide optical contact micrometers and methods of use. An example optical contact micrometer includes a pair of opposable lenses to receive an object and immobilize the object in a position. The example optical contact micrometer includes a pair of opposable mirrors positioned with respect to the pair of lenses to facilitate viewing of the object through the lenses. The example optical contact micrometer includes a microscope to facilitate viewing of the object through the lenses via the mirrors; and an interferometer to obtain one or more measurements of the object.

47 OTHER INSTRUMENTATION↗

Electron kinetics in a positive column of AC discharges in a dynamic regime

Abstract We have performed hybrid kinetic-fluid simulations of a positive column in alternating current (AC) argon discharges over a range of driving frequencies f and gas pressure p for the conditions when the spatial nonlocality of the electron energy distribution function (EEDF) is substantial. Our simulations confirmed that the most efficient conditions of plasma maintenance are observed in the dynamic regime when time modulations of mean electron energy (temperature) are substantial. The minimal values of the root mean square electric field and the electron temperature have been observed at f/p values of about 3 kHz Torr −1 in a tube of radius R = 1 cm. The ionization rate and plasma density reached maximal values under these conditions. The numerical solution of a kinetic equation allowed accounting for the kinetic effects associated with spatial and temporal nonlocality of the EEDF. Using the kinetic energy of electrons as an independent variable, we solved an anisotropic tensor diffusion equation in phase space. We clarified the role of different flux components during electron diffusion in phase space over surfaces of constant total energy. We have shown that the kinetic theory uncovers a more exciting and rich physics than the classical ambipolar diffusion (Schottky) model. Non-monotonic radial distributions of excitation rates, metastable densities, and plasma density have been observed in our simulations at pR > 6 Torr cm. The predicted off-axis plasma density peak in the dynamic regime has never been observed in experiments so far. We hope our results stimulate further experimental studies of the AC positive column. The kinetic analysis could help uncover new physics even for such a well-known plasma object as a positive column in noble gases.

Physics↗

PRECISE ABSOLUTE ASTROMETRY FROM THE VLBA IMAGING AND POLARIMETRY SURVEY AT 5 GHz

We present accurate positions for 857 sources derived from the astrometric analysis of 16 eleven-hour experiments from the Very Long Baseline Array imaging and polarimetry survey at 5 GHz (VIPS). Among the observed sources, positions of 430 objects were not previously determined at milliarcsecond-level accuracy. For 95% of the sources the uncertainty of their positions ranges from 0.3 to 0.9 mas, with a median value of 0.5 mas. This estimate of accuracy is substantiated by the comparison of positions of 386 sources that were previously observed in astrometric programs simultaneously at 2.3/8.6 GHz. Surprisingly, the ionosphere contribution to group delay was adequately modeled with the use of the total electron content maps derived from GPS observations and only marginally affected estimates of source coordinates.

79 ASTRONOMY AND ASTROPHYSICS↗