Search NASA⌕ Search

SEARCH · Search NASA

Results for “on-board processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

General Motors: Final Report for Hydrogen Storage Engineering Center of Excellence

As part of the HSECoE team, the GM team built system models and detailed transport models for on-board hydrogen storage systems using metal hydrides and adsorbent materials. Detailed transport models have been developed for both the metal hydride and adsorbent systems with a focus on optimization of heat exchanger designs with the objective of minimizing the heat exchanger mass. We also performed work in collaboration with our partners on storage media structuring and enhancement studies for the metal hydride and adsorbent materials. Since the hydrogen storage materials are generally characterized by low density and low thermal conductivity, we conducted experiments to form pellets and add thermal conductivity enhancers to the storage material, and to improve cycling stability and durability of the metal hydride and adsorbent materials. Refueling of a MOF-5 pellet with cryogenic hydrogen was studied by developing a detailed two-dimensional axisymmetric COMSOL® model of the process. The effects of pellet permeability, thermal conductivity, and thermal conductivity enhancers were investigated. Our key area of focus has been on designing and building a cryo-adsorption vessel for validation of cryo-adsorption models. The 3-L cryogenic tank was used to study the fast fill and discharge dynamics of a cryo-adsorbent storage system, both experimentally and numerically.

08 HYDROGEN↗

Methods for Estimating Hydrogen Fuel Tank Characteristics

The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.

42 ENGINEERING↗

GAHLS: an optimized graph analytics based high level synthesis framework

The urgent need for low latency, high-compute and low power on-board intelligence in autonomous systems, cyber-physical systems, robotics, edge computing, evolvable computing, and complex data science calls for determining the optimal amount and type of specialized hardware together with reconfigurability capabilities. With these goals in mind, we propose a novel comprehensive graph analytics based high level synthesis (GAHLS) framework that efficiently analyzes complex high level programs through a combined compiler-based approach and graph theoretic optimization and synthesizes them into message passing domain-specific accelerators. This GAHLS framework first constructs a compiler-assisted dependency graph (CaDG) from low level virtual machine (LLVM) intermediate representation (IR) of high level programs and converts it into a hardware friendly description representation. Next, the GAHLS framework performs a memory design space exploration while account for the identified computational properties from the CaDG and optimizing the system performance for higher bandwidth. The GAHLS framework also performs a robust optimization to identify the CaDG subgraphs with similar computational structures and aggregate them into intelligent processing clusters in order to optimize the usage of underlying hardware resources. Finally, the GAHLS framework synthesizes this compressed specialized CaDG into processing elements while optimizing the system performance and area metrics. Evaluations of the GAHLS framework on several real-life applications (e.g., deep learning, brain machine interfaces) demonstrate that it provides 14.27× performance improvements compared to state-of-the-art approaches such as LegUp 6.2.

97 MATHEMATICS AND COMPUTING↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-J-49: Design and Fabrication of Custom 3D Printed Phantoms for Radiation Therapy Research and Quality Assurance

Purpose The rapid proliferation of affordable 3D printing techniques has enabled the custom fabrication of items ranging from paper weights to medical implants. This study investigates the feasibility of utilizing the technology for developing novel phantoms for use in radiation therapy quality assurance (QA) procedures. Methods A phantom for measuring the geometric parameters of linear accelerator (LINAC) on-board imaging (OBI) systems was designed using SolidWorks. The design was transferred to a 3D printer and fabricated using a fused deposition modeling (FDM) technique. Fiducials were embedded in the phantom by placing 1.6 mm diameter steel balls in predefined holes and securing them with silicone. Several MV and kV images of the phantom were collected and the visibility and geometric accuracy were evaluated. A second phantom, for use in the experimental evaluation of a high dose rate (HDR) brachytherapy dosimeter, was designed to secure several applicator needles in water. The applicator was fabricated in the same 3D printer and used for experiments. Results The general accuracy of printed parts was determined to be 0.1 mm. The cost of materials for the imaging and QA phantoms were $22 and $5 respectively. Both the plastic structure and fiducial markers of the imaging phantom were visible in MV and kV images. Fiducial marker locations were determined to be within 1mm of desired locations, with the discrepancy being attributed to the fiducial attachment process. The HDR phantom secured the applicators within 0.5 mm of the desired locations. Conclusion 3D printing offers an inexpensive method for fabricating custom phantoms for use in radiation therapy quality assurance. While the geometric accuracy of such parts is limited compared to more expensive methods, the phantoms are still highly functional and provide a unique opportunity for rapid fabrication of custom phantoms for use in radiation therapy QA and research.

07 ISOTOPE AND RADIATION SOURCES↗

Supply Chain-Based Solution to Prevent Fuel Tax Evasion: Final Report

The primary source of funding for the United States transportation system is derived from motor fuel and other highway use taxes. Loss of revenue attributed to fuel-tax evasion has been assessed to be somewhere between 1 billion and 3 billion per year. Any solution that addresses this problem needs to include not only the tax-collection agencies and auditors, but also the carriers transporting oil products and the carriers customers. This report presents a system developed by the Oak Ridge National Laboratory (ORNL) for the Federal Highway Administration which has the potential to reduce or eliminate many fuel-tax evasion schemes. The solution balances the needs of tax-auditors and those of the fuel-hauling companies and their customers. The system has three main components. The on-board subsystem combined sensors, tracking and communication devices, and software (the on-board Evidential Reasoning System, or obERS) to detect, monitor, and geo-locate the transfer of fuel among different locations. The back office sub-system (boERS) used self-learning algorithms to determine the legitimacy of the fuel loading and offloading (important for tax auditors) and detect potential illicit operations such as fuel theft (important for carriers and their customers, and may justify the deployment costs). The third sub-system, the Fuel Distribution and Auditing System or FDAS, is a centralized database, which together with a user interface allows tax auditors to query the data submitted by the fuel-hauling companies and correlate different parameters to quickly identify any anomalies. Industry partners included Barger Transport of Weber City, Virginia (fleet); Air-Weigh, of Eugene, Oregon (and their wires and harnesses); Liquid Bulk Tank (LBT) of Omaha, Nebraska (three five-compartment trailers); and Innovative Software Engineering (ISE) of Coralville, Iowa(on-board telematics device and back-office system). ORNL conducted a pilot test with the three instrumented vehicles collecting real-world data during an eight-month period (October 2014 to June 2015). The vehicles logged a total of 375,000 miles and transported more than 7.5 million gallons of fuel. The drivers entered information on the telematics device about 77% of the time, with about 15% (10%) of the data showing at least one compartment with loading (offloading) valve activity, but not driver information entry for that compartment. Seven events (or about 0.7% of the trips) were identified by the boERS as having a missing fuel diversion number. The solution developed and tested in the pilot test had federal- and state-level tax auditors as its main audience. Nonetheless, the technology has to be adopted by the fuel carriers and therefore the solution had to address the needs of fuel-hauling companies and their customers (i.e., fuel theft and cocktailing). Sensors in the hatches allowed the obERS recognize when one of those were opened (always a suspicious activity, unless it happens at locations where maintenance is performed on the vehicle). The fuel-theft issue was addressed by a self-learning algorithm deployed on the boERS that continuously processed the data from the field to construct probability distributions of measures such as elapsed time of fuel loading and offloading by driver, vehicle, and compartment, valve actuation sequence, elapsed time between the first two valve actuations (by driver, compartment, and location), and other parameters. Probability thresholds, which can be set up by the carrier, determined how to classify the observed events. The boERS also kept track of valve sequencing at a given location and analyzed these actuations to help identify any suspicious activities. Technical and economic recommendations include: a) simplification of the driver data-entry task; b) reduction of system deployment cost; c) addition of capabilities that make the system more appealing to industry (i.e., identify and avoid fuel misdelivery); and d) incorporation of additional capabilities to the FDAS. Path to commercialization recommendations include: a) identify a company willing to further develop, test, and certify a hardened system with a price point the market will bear; b).transfer ERS to licensee; c) establish a fleet or fleets who want this technology for carrier benefits or trailer manufacturer who wants to offer it as optional technology; and d) identify a location for the deployment of FDAS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-G-JeP4-14: Assessment of Inter- and Intra-Fractional Motion for Extremity Soft Tissue Sarcoma Patients by Using In-House Real-Time Optical Image-Based Monitoring System

Purpose: This study aimed to assess inter- and intra-fractional motion for extremity Soft Tissue Sarcoma (STS) patients, by using in-house real-time optical image-based monitoring system (ROIMS) with infra-red (IR) external markers. Methods: Inter- and intra-fractional motions for five extremity (1 upper, 4 lower) STS patients received postoperative 3D conformal radiotherapy (3D-CRT) were measured by registering the image acquired by ROIMS with the planning CT image (REG-ROIMS). To compare with the X-ray image-based monitoring, pre- and post-treatment cone beam computed tomography (CBCT) scans were performed once per week and registered with planning CT image as well (REG-CBCT). If the CBCT scan is not feasible due to the large couch shift, AP and LR on-board imager (OBI) images were acquired. The comparison was done by calculating mutual information (MI) of those registered images. Results: The standard deviation (SD) of the inter-fractional motion was 2.6 mm LR, 2.8 mm SI, and 2.0 mm AP, and the SD of the intra-fractional motion was 1.4 mm, 2.1 mm, and 1.3 mm in each axis, respectively. The SD of rotational inter-fractional motion was 0.6° pitch, 0.9° yaw, and 0.8° roll and the SD of rotational intra-fractional motion was 0.4° pitch, 0.9° yaw, and 0.7° roll. The derived averaged MI values were 0.83, 0.92 for REG-CBCT without rotation and REG-ROIMS with rotation, respectively. Conclusion: The in-house real-time optical image-based monitoring system was implemented clinically and confirmed the feasibility to assess inter- and intra-fractional motion for extremity STS patients while the daily basis and real-time CBCT scan is not feasible in clinic.

60 APPLIED LIFE SCIENCES↗

Developing Fuel Cell Electric Powertrain Architectures for Commercial Vehicles

Here, this article addresses the architecture development for a commercial vehicle fuel cell electric powertrain by establishing a clear multi-step formalized workflow that employs a unique technoeconomic solution for architecture selection. The power capability of the fuel cell, the energy capacity and chemistry of the electrical energy storage (battery), the DC-DC converter (including the input current rating and isolation resistance requirements), the traction drive solution, the on-board hydrogen storage solution, and the real-time power-split management of the fuel cell and the battery are all considered and developed in this effort. The methods were used to select architecture for Class 8 urban, regional, and line haul applications. When compared to traditional load-following power-split controllers, an energy management power-split controller can increase system energy efficiency by up to 19.5%. The energy-efficient power-split controller may increase the required battery capacity for an equivalent life by up to 2.6 times. The impact on the total cost of ownership (TCO) for a variety of financial cases demonstrates that high C-rate capable batteries have the potential to provide better TCO solutions over a six-year vehicle life than low C-rate capable batteries. To achieve TCO parity with the 600 A non-isolated DC-DC converter case, the specific choice of the fuel cell DC-DC converter to achieve a target power output based on current levels (from 500 A to 2400 A) shows that efficiency decreases and cost increases due to the higher current, requiring fuel cell prices to decrease by $50–$100/kW, $60–$110/kW, and $100–$220/kW for urban, regional, and line haul applications, respectively. Key recommendations for powertrain system architectures are provided, with specifics based on vehicle dynamics, mission and application characteristics, end customer use-case profile, critical powertrain component costs, and architecture selection cost function. This study rigorously demonstrates the interplay of the above parameters, with a focus on TCO, and provides application decision-makers with a mechanism and well-defined set of impact factors to consider as part of their architecture selection process.

25 ENERGY STORAGE↗

SU-F-J-14: Kilovoltage Cone-Beam CT Dose Estimation of Varian On-Board Imager Using GMctdospp Monte Carlo Framework

Purpose: Although cone-beam CT (CBCT) imaging became popular in radiation oncology, its imaging dose estimation is still challenging. The goal of this study is to assess the kilovoltage CBCT doses using GMctdospp - an EGSnrc based Monte Carlo (MC) framework. Methods: Two Varian OBI x-ray tube models were implemented in the GMctpdospp framework of EGSnrc MC System. The x-ray spectrum of 125 kVp CBCT beam was acquired from an EGSnrc/BEAMnrc simulation and validated with IPEM report 78. Then, the spectrum was utilized as an input spectrum in GMctdospp dose calculations. Both full and half bowtie pre-filters of the OBI system were created by using egs-prism module. The x-ray tube MC models were verified by comparing calculated dosimetric profiles (lateral and depth) to ion chamber measurements for a static x-ray beam irradiation to a cuboid water phantom. An abdominal CBCT imaging doses was simulated in GMctdospp framework using a 5-year-old anthropomorphic phantom. The organ doses and effective dose (ED) from the framework were assessed and compared to the MOSFET measurements and convolution/superposition dose calculations. Results: The lateral and depth dose profiles in the water cuboid phantom were well matched within 6% except a few areas - left shoulder of the half bowtie lateral profile and surface of water phantom. The organ doses and ED from the MC framework were found to be closer to MOSFET measurements and CS calculations within 2 cGy and 5 mSv respectively. Conclusion: This study implemented and validated the Varian OBI x-ray tube models in the GMctdospp MC framework using a cuboid water phantom and CBCT imaging doses were also evaluated in a 5-year-old anthropomorphic phantom. In future study, various CBCT imaging protocols will be implemented and validated and consequently patient CT images will be used to estimate the CBCT imaging doses in patients.

60 APPLIED LIFE SCIENCES↗

SU-E-J-189: Determination of Markerless Lung Tumor Position in Real Time: A Feasibility Study Using a Novel Tomo-Cinegraphy Imaging

Purpose: A Tomo-Cinegraphy (TC) is a method to generate a series of temporal tomographic images from projection images of the on-board imager (OBI) while gantry is moving. It is to test if this technique is useful to determine a lung tumor position during treatments. Methods: Tomographic image via background subtraction, TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). This idea was extended to a TC, which enables to generate tomographic images of same geometry from the projection of different gantry angles and different breathing phases. Projection images of a lung patient for CBCT acquisition are used to generate TC images. A region of interest (ROI) is selected around a tumor adding 2cm margins. Center of mass (COM) of the ROI is traced to determine tumor position for every projection images. Results: Tumor is visible in the TC images while the OBI projections are not. The coordinates of the COMs represent the temporal tumor positions. While, it is not possible to trace the tumor motion using the projection images. A source of time delay is the time to acquire projection images, which is always less than a second. Conclusion: TC allows tracking the tumor positions without fiducial markers in real time for some lung patients, if the projection images are acquired during treatments. Partially supported by NIH R01CA133539.

60 APPLIED LIFE SCIENCES↗

SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based on total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.

60 APPLIED LIFE SCIENCES↗

From Fundamental Understanding To Predicting New Nanomaterials For High Capacity Hydrogen/Methane Storage and Carbon Capture

On-board hydrogen/methane storage in fuel cell-powered vehicles is a major component of the national need to achieve energy independence and protect the environment. The main obstacles in hydrogen storage are slow kinetics, poor reversibility and high dehydrogenation temperatures for the chemical hydrides; and very low desorption temperatures/energies for the physisorption materials (MOF’s, porous carbons). Similarly, the current methane storage technologies are mainly based on physisorption in porous materials but the gravimetric and volumetric storage capacities are below the target values. Finally, carbon capture, a critical component of the mitigation of CO 2 emissions from industrial plants, also suffers from similar problems. The solid-absorbers such as MOFs are either not stable against real flue-gas conditions and/or do not have large enough CO 2 capture capacity to be practical and cost effective. In this project, we addressed these challenges using a unique combination of computational, synthetic and experimental methods. The main scope of our research was to achieve fundamental understanding of the chemical and structural interactions governing the storage and release of hydrogen/methane and carbon capture in a wide spectrum of candidate materials. We studied the effect of scaffolding and doping of the candidate materials on their storage and dynamics properties. We reviewed current progress, challenges and prospect in closely related fields of hydrogen/methane storage and carbon capture. For example, for physisorption based storage materials, we show that tap-densities or simply pressing MOFs into pellet forms reduce the uptake capacities by half and therefore packing MOFs is one of the most important challenges going forward. For room temperature hydrogen storage application of MOFs, we argue that MOFs are the most promising scaffold materials for Ammonia-Borane (AB) because of their unique interior active metal-centers for AB binding and well defined and ordered pores. Here the main challenge is to find a chemically stable MOF required for regeneration of the AB-spent fuel. Finally, for carbon capture application of MOFs, we investigate the performance of a number of metal–organic frameworks with particular focus on their behavior at the low pressures commonly used in swing adsorption. This comparison clearly shows that it is the process that determines which MOF is optimal rather than there being one best MOF, though MOFs that possess enhanced binding at open metal sites generally perform better than those with high surface area.

03 NATURAL GAS↗

An integrated model-driven method for in-treatment upper airway motion tracking using cine MRI in head and neck radiation therapy

Purpose: For the first time, MRI-guided radiation therapy systems can acquire cine images to dynamically monitor in-treatment internal organ motion. However, the complex head and neck (H&N) structures and low-contrast/resolution of on-board cine MRI images make automatic motion tracking a very challenging task. In this study, the authors proposed an integrated model-driven method to automatically track the in-treatment motion of the H&N upper airway, a complex and highly deformable region wherein internal motion often occurs in an either voluntary or involuntary manner, from cine MRI images for the analysis of H&N motion patterns. Methods: Considering the complex H&N structures and ensuring automatic and robust upper airway motion tracking, the authors firstly built a set of linked statistical shapes (including face, face-jaw, and face-jaw-palate) using principal component analysis from clinically approved contours delineated on a set of training data. The linked statistical shapes integrate explicit landmarks and implicit shape representation. Then, a hierarchical model-fitting algorithm was developed to align the linked shapes on the first image frame of a to-be-tracked cine sequence and to localize the upper airway region. Finally, a multifeature level set contour propagation scheme was performed to identify the upper airway shape change, frame-by-frame, on the entire image sequence. The multifeature fitting energy, including the information of intensity variations, edge saliency, curve geometry, and temporal shape continuity, was minimized to capture the details of moving airway boundaries. Sagittal cine MR image sequences acquired from three H&N cancer patients were utilized to demonstrate the performance of the proposed motion tracking method. Results: The tracking accuracy was validated by comparing the results to the average of two manual delineations in 50 randomly selected cine image frames from each patient. The resulting average dice similarity coefficient (93.28% ± 1.46%) and margin error (0.49 ± 0.12 mm) showed good agreement between the automatic and manual results. The comparison with three other deformable model-based segmentation methods illustrated the superior shape tracking performance of the proposed method. Large interpatient variations of swallowing frequency, swallowing duration, and upper airway cross-sectional area were observed from the testing cine image sequences. Conclusions: The proposed motion tracking method can provide accurate upper airway motion tracking results, and enable automatic and quantitative identification and analysis of in-treatment H&N upper airway motion. By integrating explicit and implicit linked-shape representations within a hierarchical model-fitting process, the proposed tracking method can process complex H&N structures and low-contrast/resolution cine MRI images. Future research will focus on the improvement of method reliability, patient motion pattern analysis for providing more information on patient-specific prediction of structure displacements, and motion effects on dosimetry for better H&N motion management in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗

TU-AB-303-10: KVCBCT, MVCBCT and MVCT On-Board Imaging Suitability for An Urgent Radiotherapy Treatment Workflow

Purpose: A comparison of image quality and dose calculation accuracy to study the suitability of available on-board imaging systems for a new treatment workflow in emergency radiotherapy situations. Methods: Water and anthropomorphic phantom images were acquired on four different Linac on-board imaging systems, including kVCBCT (Varian TrueBeam and Elekta VersaHD), MVCBCT (Siemens Artiste) and MVCT (Accuray Tomotherapy). Simple treatments of single or opposed beams were planned on the respective kVCT images and copied to all CT images. Image suitability for dose planning was based on the overall mean dose differences and 3D gamma index with 3%/3mm criteria for a prescription of 100 monitor units (MU) and differences in calculated MUs per plan for dose prescriptions to mid-plane. Results: TrueBeam kVCBCT and Tomotherapy MVCT images produced most accurate dose calculation for all tested cases (γ-index >95%). MVCBCT and VersaHD kVCBCT images resulted in minimum γ-passing rates of 94% and 87%, respectively. MUs calculated from treatment plans prescribed to mid-plane were within differences of 5% relative to kVCT-based plans in all cases. However, VersaHD images showed considerable local image artifacts in the pelvis water and anthropomorphic neck phantom that complicated accurate Hounsfield unit (HU) to electron density conversion, thus causing local dose differences of more than 10% relative to kVCT-based dose distributions. Conclusion: TrueBeam kVCBCT, MVCBCT and MVCT systems provide image quality that allows for accurate simple treatment plan calculation. Prescription points should be placed away from areas found to cause local dose discrepancies, such as air cavities. Improved image filter settings and HU-to-electron density calibration adjustments may be required for the VersaHD system to obtain an overall accurate dose distribution. To evaluate a system’s overall suitability, its clinical features also require consideration, such as imaging field of view, acquisition time and the ability to instantly export images for treatment planning.

60 APPLIED LIFE SCIENCES↗

Demonstration of waferscale voltage amplifier and electrostatic quadrupole focusing array for compact linear accelerators

Compact linear accelerators, with beam energies in the kiloelectron volt to megaelectron volt range, have applications in medicine, neutron/X-ray generation, surface modifications, etc. The size, weight, and power of existing accelerators preclude them from mass availability in portable formats. This paper presents a specific implementation of an ion accelerator architecture based on planar wafers with accelerating and focusing sections. Our low cost approach allows the control of the final ion beam energy with potential applications, for example, for accelerator-based ion implantation. In this paper, we demonstrate two important waferscale modules required to build a linear particle accelerator; these include (1) on-wafer voltage amplification for beam acceleration using Inductor-Capacitor (LC) resonators and (2) waferscale electrostatic quadrupole arrays (ESQA) to refocus the ion beams during transport. On-board LC resonators were developed using Printed Circuit Board fabrication processes to implement an LC element resonant at ~ 16.6 MHz with a quality factor of 25. An energy gain of ~ 250 eV was observed using a two wafer acceleration unit with an argon ion beam with 6.5 keV initial energy. A 3 × 3 ESQA was fabricated on a glass wafer with metal electrodes formed by depositing copper metal around the beam apertures. The ESQA was used to focus and defocus an argon ion beam, demonstrating a field gradient of ~ 500 V over a gap of ~ 250 μm.

43 PARTICLE ACCELERATORS↗

Transit Rider/Travel Behavior Inventory Survey - Minneapolis-St. Paul Metro - 1990

The 1990 transit on-board survey aimed to update the 1988 survey, which was conducted as part of the Preliminary Engineering Study for the Hennepin County Light Rail Transit System. The 1988 study received Regional Transit Board funding, and survey results could be applied to a mode split model for projecting ridership on the proposed Light Rail Transit System. However, this survey was designed with the 1990 Travel Behavior Inventory in mind. The intention had been to update the 1988 survey in 1990 to be compatible with the 1990 Travel Behavior Inventory data. The results of the 1990 survey were used primarily to create a table of observed transit trips between each of the 1,200 traffic analysis zones in the region. This trip table was used to calibrate a new mode split model, which estimated future year travel by mode. The 1990 update survey focused on new routes and routes that had changed significantly since 1988. To preserve compatibility with the 1988 survey, the same survey questionnaire card was used, together with the same survey procedures for data collection. The procedures randomly sampled bus patrons during the transit trip, asking key questions about the patron and the transit trip. The survey card was intended for patrons to fill out quickly so it could be completed during the transit trip. The questions focused on conditions that have proven over time to significantly influence ridership. In all, a total of 20,126 valid survey records were processed. Adding surrogate trips, the survey data file is composed of a total of 27,159 trip records . About 10% of the records were filled out by persons who had answered more than one questionnaire.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Signal Processing for Beam Loss Monitor System at Jefferson Lab

Ion Chamber and Photomultiplier Tube (PMT) are both used for beam loss monitor in the Machine Protection System (MPS) at Jefferson Lab. The requirements of signal processing of these detectors are different, so two VME-based signal processing boards, Beam Loss Monitor (BLM) board and Ion-Chamber board, were developed. The BLM board has fast response (< 1us) and 5 decades dynamic range from 10nA to 1 mA, while the Ion-Chamber board has 8 decades dynamic range from 100 pA to 10 mA and slower response. Both of boards provide functions of machine protection and beam diagnostics, and features of fast shutdown (FSD) interface, beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer.

Yan, J.↗