Search NASA⌕ Search

SEARCH · Search NASA

Results for “opacity experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Laser-Driven Dynamic Hohlraums

A novel approach for laser-driven inertial confinement fusion is described, that of the laser-driven dynamic hohlraum. Combining direct and x-ray drive, the laser-driven dynamic hohlraum uses a radiatively collapsed shock to confine x-radiation and drive an inner capsule. Ignition is predicted for such a system on the National Ignition Facility. In this LDRD the laser-driven dynamic hohlraum was experimentally investigated on the Omega laser. In addition, the laser-driven dynamic hohlraum was investigated as a possible bright, short duration, continuum x-ray source suitable for opacity experiments. Results from these dynamic hohlraum experiments are presented, showing both agreement with and discrepancies with simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)

We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Investigation of Iron Plasma Opacity Models

Recent experiments extended iron opacity model tests to temperatures above 150 eV for the first time. The experiments use the Z Facility to volumetrically heat a CH-tamped Fe/Mg plasma using x-rays. The frequency dependent sample transmission is measured by viewing a backlight through the sample. The plasma conditions are inferred from the Mg K-shell absorption. The strategy for this research is to examine the underlying physics within Fe opacity models by comparisons with the measured transmission. Physics topics of interest include charge state distribution, energy level structure, and line broadening. In this talk we discuss methods to exploit the data and advance understanding for these topics. In addition, we review new experiments under way to further improve the data and to achieve higher energy density conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error Budgeting

We calculate opacity from k (hn)=-ln[T(hv)]/pL, where T(hv) is the transmission for photon energy hv, p is sample density, and L is path length through the sample. The density and path length are measured together by Rutherford backscatter. Δk = $\partial k$\ $\partial T$ ΔT + $\partial k$\ $\partial (pL)$. We can re-write this in terms of fractional error as Δk/k = Δ1n(T)/T + Δ(pL)/(pL). Transmission itself is calculated from T=(U-E)/(V-E)=B/B0, where B is transmitted backlighter (BL) signal and B 0 is unattenuated backlighter signal. Then ΔT/T=Δln(T)=ΔB/B+ΔB 0 /B 0 , and consequently Δk/k = 1/T (ΔB/B + ΔB$_0$/B$_0$ + Δ(pL)/(pL). Transmission is measured in the range of 0.2<T<0.6 so that 1.5<1/T<5.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A requirement for diagnosis of the ionization state in opacity measurements

An accurate independent diagnosis of the temperature and the ionization state of the sample plasmas is important to get a set of well-characterized opacity data in experiment. An analysis of using x-ray scattering was presented for this purpose. Information of the ionization state of the sample plasmas could only be clearly detected when both the Compton and Rayleigh features of the scattering spectra are detectable in one laser shot. Only those plasmas with a few bounded electrons left can provide such kind of scattering spectra. The requirements for using the x-ray scattering as diagnosis are rigorous. Under a radiation field produced by laser-heated hohlraum, only limited number of sample elements can be heated to the ionization state required. Careful design is needed to achieve an x-ray scattering experiment. This work can be helpful to establish a diagnostic flattop for the opacity experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating the rate of discovery: toward high-repetition-rate HED science

As high-intensity short-pulse lasers that can operate at high-repetition-rate (HRR) (>10 H z ) come online around the world, the high energy density (HED) science they enable will experience a radical paradigm shift. The >10 3 increase in shot rate over today's shot-per-hour drivers translates into dramatically faster data acquisition, more experiments, and the ability to exploit machine learning, and thus the potential to significantly accelerate the advancement of HED science. A wide range of HED experiments, from opacity investigations to secondary source generation to plasma nuclear physics, will benefit from the increased statistics, precision, and exploration of phase space. Besides increasing the rate at which scientific experiments can be performed, HRR also allows for the rapid delivery of optimal experiments supported by simulations and modeling augmented by close coupling to empirical data. To fully realize such an HRR framework, numerous subsystems must be developed and brought together, including feedback laser control loops, high-throughput targetry and diagnostics, cognitive simulation, enhanced HED codes, and advanced data analytics. This paper describes the vision for an integrated HRR laser experimental HED system and outlines some of the major considerations and challenges for realizing it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oxygen Opacity Measurements at High-Energy-Density Conditions

We present the first benchmark measurements of oxygen opacity at high-energy-density, crucial for understanding stellar interiors. A 3–5−μm thick SiO 2 sample was heated using a Z facility x-ray source, and opacity was measured in the 5–19.5 Å range with multiple spectrometers. The electron temperature and density inferred from Si 𝐾-shell spectra were 148 ± 4 eV and 8.6 ±1.4 × 10 21 cm −3 , respectively. Six experiments showed opacity reproducibility within ±15% and 5%–25% opacity uncertainty. Measured oxygen opacity and seven different opacity models exhibit extraordinary overall agreement. Discrepancies near the H-like photon ionization threshold and in certain spectral lines suggest the need for model refinements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Ignition Facility Opacity Time Resolved Spectrometer Systems Engineering Final Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser facility. The NIF system is designed to produce high energy density (temperature and pressure) conditions through the application of its 192 laser beams. One of the users of NIF is the opacity platform developed to study the opacities at temperatures and densities relevant to the solar interior and stellar evolution. The platform was developed to study iron (Fe) opacity at temperatures relevant to the solar interior. The opacity campaign uses spectrometers to gather data. Spectrometers utilize crystals to produce x-ray spectra that are recorded on time-integrated and time-resolved detectors. The opacity spectrometer (OpSpec) currently fielded and in use at NIF uses a time integrated film channel to collect data. The opacity spectrometer time resolved (OpSpecTR) will utilize novel hCMOS detectors to capture time resolved images of spectra of interest. The key stakeholders identified for OpSpecTR included the physicists responsible for OpSpec and OpSpecTR, the Target Area Science and Engineering (TASE) department at NIF, the NIF and Photon Science (NIF & PS) Opacity program, the Nevada National Security Site (NNSS) Physics and Engineering program, the Sandia hCMOS manufacturing and testing program, and the Los Alamos National Laboratory (LANL) program sponsor. The Target and Experimental Operations (TEXOPS) was identified as a key stakeholder because the group includes the individuals that will physically interact with the OpSpecTR system as it participates in NIF experiments. The opacity platform collects data in a unique orientation relative to the existing diagnostics fielded at NIF. The existing infrastructure at NIF uses a diagnostic manipulator (DIM) to insert the diagnostic near the target chamber center to collect data during a NIF shot. Existing diagnostics collect data through the center line of the DIM axis and collect relevant data perpendicular to this axis. The opacity platform requires crystals mounted in a specific orientation which requires data collection parallel to the DIM axis. This deviation from standard NIF practices was a key factor in developing requirements.

42 ENGINEERING↗

Capsule implosions for continuum x-ray backlighting of opacity samples at the National Ignition Facility

Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500–2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ~20 μm thickness have been performed. X-ray yields of up to ~1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ~100 μm FWHM, with ~350 ps pulse duration during the peak emission stage. Lastly, these results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial experimental demonstration of the principles of a xenon gas shield designed to protect optical components from soft x-ray induced opacity (blanking) in high energy density experiments

The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1 , 250–300 eV). Blanking of fused silica (SiO 2 ) was measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2 . A shield test device consisting of a 30 nm silicon nitride (Si 3 N 4 ) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.

42 ENGINEERING↗

An Overview of the Los Alamos Inertial Confinement Fusion and High-Energy-Density Physics Research Programs

The Los Alamos Inertial Confinement Fusion and Science Programs engage in a vigorous array of experiments, theory, and modeling. We use the three major High Energy Density facilities, NIF, Omega, and Z to perform experiments. These include opacity, radiation transport, hydrodynamics, ignition science, and burn experiments to aid the ICF and Science campaigns in reaching their stewardship goals. The ICF program operates two nuclear diagnostics at NIF, the neutron imaging system and the gamma reaction history instruments. Both systems are being expanded with significant capability enhancements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opacity Table Generation

Radiation opacity is a key property of material systems which describes the absorption and scattering of photons. Such processes are an important part of energy transport, diagnostics, and astrophysical phenomena. Recent experiments in iron opacity and continuum lowering have sparked renewed interest in and careful vetting of opacity models. Even within the local thermodynamic equilibrium approximation, opacity varies over a large parameter space: material, temperature, density, and energy. Opacity tables that span wide regimes of this parameter space are of prime importance to radiation-hydrodynamics codes. Accurate opacity calculations cannot be achieved inline during a radiation hydrodynamics simulation since they involve accounting for all possible electron transitions of all important atomic states of a thermal ensemble. Livermore’s current framework utilizes precalculated tables at many densities, temperatures, and energies. Last year, the opacity theory team completed an L2 milestone concerning the development of a new code, Opus, which served the dual purpose of creating a modern code infrastructure and version control as well as the basis for training new members of that team, a critical need as key members near or are passed retirement. For the current L2 milestone, we exercised and validated Opus on three elements: boron, carbon, and nitrogen, which have few enough electrons to allow a careful convergence study over many input parameters. Here, we report on the production of new tables, show their convergence with respect to important parameters, state some of their limitations, and document a mostly automated production process. In this section, we address the milestone completion criteria, found on the title page and the subsection headings. In section 2, we validate Opus against Tycho and compare with TabOp and Atomic. Section 3 details some of the physics implemented in Opus and relevant to this report. We then cover details of the density-temperature grid in section 4 and do a spectral comparison between different parameter settings and different codes in section 5. After summarizing these results in section 6, we give instructions how to run the opacity table scripts in appendix A and document the scripts and input/output files in appendix B.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DANTE as a primary temperature diagnostic for the NIF iron opacity campaign

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm−3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm−3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

Opachich, Y. P. (ORCID:0000000314323989)↗

FY2024 Q4 L2 Milestone 8237 for Opacity-on-NIF

This document addresses parts 2 and 3 of the original milestone request. In the following writeup, the development of OpSpecTR at LLNL by LLNL and NNSS personnel will be detailed first, followed by a write-up of the development of Vme-resolved simulaVons of the opacity-on-NIF experiment. Capsule backlight simulaVons, hohlraum simulaVons, and sample simulaVons from CASSIO are combined to produce the line of sight from the capsule to an effecVve OpSpec posiVon. Spectra are generated by post-processing these simulaVons from either Spect3D, a commercial software by Prism ComputaVonal Sciences, or FESTR (Finite Element Spectroscopic Transport of RadiaVon), a LANL code. While the simulaVons do not at this stage proceed late enough to include the worst of the backgrounds generated from the hohlraum experimentally and each post-processing simulaVon includes only one ray for each spectrometer channel, these efforts represent proof of concept for a new capability to complete Vme-resolved and Vmegated simulaVons for the complete line of sight of the complex opacity-on-NIF geometry. Future work will be discussed at the end of the report for both efforts.

42 ENGINEERING↗

Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements

The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 10 21 cm −3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 10 22 cm −3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 10 22 cm −3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. In conclusion, the resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.

Absorption spectroscopy↗