Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems may become more widely deployed throughout the country, and so it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity of the facility, and the company that owns the facility. The two main ways bad actors may access information or control from a hydrogen storage facility are through information technology and operations technology devices, the former of which refers to data and information from networked devices and the latter of which refers to onsite controls for the physical system. Both types of entryways into the system should be considered when companies conduct cyber risk assessments and when regulators develop or revise relevant codes and standards. This report analyzes cybersecurity risks associated with a generic hydrogen storage system by outlining the system's purpose and the importance of its cybersecurity. The hydrogen storage system architecture and communication protocols are provided to understand potential cyber vulnerabilities. Later, an event tree analysis is performed on hydrogen operation to identify system weaknesses by outlining potential attack scenarios. This report also identifies critical cyber assets related to different hydrogen operations followed by an examination of potential threats, and the impact of cyber assets on those operational assets.

08 HYDROGEN↗

Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems are becoming more widely deployed throughout the country, and as their presence continues to grow, it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity, and to the company that owns the facility. The two main mechanisms malicious actors may access information or control from a hydrogen storage facility are through information technology and operations technology devices, the former of which refers to data and information from networked devices and the latter of which refers to onsite controls for the physical system. Both types of entryways into the system should be considered when facility managers conduct cyber risk assessments and when regulators develop or revise relevant codes and standards. This report analyzes cybersecurity risks applicable to a wide variety of hydrogen storage systems by outlining the system's purpose and the importance of its cybersecurity. The hydrogen storage system architecture and communication protocols are provided to understand potential cyber vulnerabilities. Later, an event tree analysis is performed on hydrogen operation to identify system weaknesses by outlining potential attack scenarios. This report also identifies critical cyber assets related to different hydrogen operations followed by an examination of potential threats, and the impact of cyber assets on those operational assets.

08 HYDROGEN↗

The Benefits of a Software Bill of Materials Program at Nuclear Facilities

Software supply chain attacks are becoming increasingly more prevalent in both information communications technology and operational technology environments. Often, a supplier or other entity discloses vulnerability information about software components and subcomponents used in a digital asset, but an asset owner is unable to quickly ascertain if the vulnerable component is installed in their facility. The generation and use of a software bill of materials (SBOM) for installed digital assets can enable an asset owner to quickly identify if and where a component is used, allowing them to evaluate the risk and determine necessary risk treatments. The integration of an SBOM program into a nuclear facility not only improves vulnerability management and risk management processes, it also benefits asset and configuration management, cybersecurity, and supply chain programs. This paper reviews the U.S. Department of Energy Office of Nuclear Energy Cybersecurity Crosscutting Technology Development program’s work on integrating an SBOM program into a nuclear facility. It also provides a discussion on the benefits of such a program.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Informing Cybersecurity Decisions With the Value-at-Risk Framework

Security at every site is critical to making hydropower a strong contributor to the country's grid, but with ongoing development and expanding capabilities, the diversity of the existing hydropower fleet makes across-the-board investment decisions difficult. The threat of cyberattacks naturally increases as the interconnection of Information Technology and Operational Technology networks broadens. Hydropower plants require custom analyses that are specific to the unique challenges and characteristics of any given facility. Facilities, however, often do not have the necessary resources for managers to make informed decisions on investments based on assessed capabilities and risks.

50 EE - Wind and Water Power Program - Water (EE-4↗

Informing Cybersecurity Decisions With the Value-at-Risk Framework

Security at every site is critical to making hydropower a strong contributor to the country's grid, but with ongoing development and expanding capabilities, the diversity of the existing hydropower fleet makes across-the-board investment decisions difficult. The threat of cyberattacks naturally increases as the interconnection of Information Technology and Operational Technology networks broadens. Hydropower plants require custom analyses that are specific to the unique challenges and characteristics of any given facility. Facilities, however, often do not have the necessary resources for managers to make informed decisions on investments based on assessed capabilities and risks.

cybersecurity↗

Cybersecurity Anomaly Detection in SCADA-Assisted OT Networks Using Ensemble-Based State Prediction Model

The cybersecurity threats of power system gradually grow due to the increased sophisticated interactions between Information Technology (IT) and Operational Technology (OT) networks. False data injection attack (FDIA) that aims to compromise the Supervisory Control and Data Acquisition (SCADA) measurement and disturb the system operation is one of such cyber threats. Such attacks can potentially lead to significant operational issues at the control centers and substations, and hence, result in severe physical consequences. To avoid catastrophic failure across the power grid resulting from these attacks, it is essential to arm the OT network with real-time vulnerability assessment tools. To this end, this paper outlines various drawbacks of the Purdue architecture model to defend against cyberattacks in the OT network. Furthermore, a novel ensemble-based state prediction model is proposed to detect cybersecurity anomalies in SCADA assisted OT networks. The proposed model uses control center level generation and load forecasts, scheduled, and forced outages, power flow solutions, and the substation level historical data. The hypothesis of the proposed scheme relies on the fact that additional control center and substation data can hardly be accessed and compromised by attackers. One of the vital features of the proposed scheme is an hour-ahead prediction of the operational feasibility of the SCADA measurement range at the control center and substation in real time helps in detecting anomalies in measurements across both substation and the control center.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Living-off-the-land Techniques Unlikely to Supplant Energy Sector-Focused OT-Specific Malware

Despite increased reports of energy sector-focused threat actors using living-off-the-land (LOTL) techniques, it is unlikely LOTL techniques will wholly supplant malware in energy sector operational technology (OT)-focused cyber operations. Threat actors leverage LOTL techniques to access energy sector networks, abstracting process information and maintaining persistence. Although threat actors using LOTL techniques have successfully interrupted energy sector industrial control environments, designed features of OT-specific malware likely increase the cyber-physical impact of an attack and delay recovery of critical functions and services. Malicious actors will very likely continue to use LOTL techniques for stealth, while designing malware to bolster final impacts on cyber-physical systems in energy sector OT environments.

99 GENERAL AND MISCELLANEOUS↗

Precursor Analysis Report: Cyber Attack on Thyssenkrupp Blast Furnace 2014

The Cyber Attack on Thyssenkrupp Blast Furnace 2014 Precursor Analysis Report leverages publicly available information about the Thyssenkrupp Steel Mill cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. In December 2014, the German Government’s Federal Office for Information Security (BSI) released a report detailing a cyber attack on a German steel mill that occurred earlier that year, though exact dates and details of the attack were not revealed. While the report did not specify the name of the company, multiple sources identified the victim as one of Europe’s largest steel manufacturers, Thyssenkrupp AG. Further, Thyssenkrupp announced on 16 May of that year that Europe’s largest blast furnace, “Schwelgern 2,” located at its facility in Duisburg, Germany, would be offline for several weeks for repairs and upgrades, suggesting Schwelgern 2 was likely the target of the attack. The attack began in early 2014, when adversaries infiltrated the victim steel mill’s Information Technology (IT) network via a spearphishing campaign, then worked their way into the Operational Technology (OT) environment, where they executed software that caused denial of service, denial of control, and eventually a loss of control. This led to the blast furnace shutting down without proper safety procedures, resulting in catastrophic physical damage. No lives were lost in the incident, but ThyssenKrupp suffered $4 million in damage to the blast furnace and an additional $6 million in lost revenue. The adversaries required specialized knowledge and expertise in steel production, which enabled them to compromise a variety of internal systems and components across both IT and OT networks. The attack also demonstrated detailed knowledge of the industrial control systems (ICS) and production processes being used. This combination resulted in one of the earliest known publicly reported cybersecurity incidents resulting in physical damage to ICS equipment. Researchers and analysts identified 19 unique techniques (used in a sequence of 20 steps) utilized during the attack with a total of 454 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the Thyssenkrupp cyber attack were precursors to the triggering event. Analysis identified 369 observables associated with these precursor techniques, 316 of which were assessed to have an increased likelihood of being perceived in the 120 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

HP in Cybersecurity: CyOTE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently detect adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. Unlike the approach taken with commercial security solutions, CyOTE seeks to tie anomalies in cyber operations to a cyber-attack. By stringing together multiple techniques in the OT environment, AOOs can identify attack campaigns with ever decreasing impacts. The CyOTE methodology applies fundamental concepts of perception and comprehension to a universe of knowns and unknowns increasingly disaggregated into observables, anomalies, and triggering events. MITRE’s ATT&CK® Framework for Industrial Control Systems (ICS) is used as a common lexicon to identify a set of triggering events related to three Use Cases – Alarm Logs, Human-Machine Interface (HMI), and Remote Logins – which together account for 87 percent of the techniques commonly used by adversaries. The CyOTE methodology is also appropriate for OT-related anomalies perceived outside the three Use Cases, such as through the energy system itself.

99 GENERAL AND MISCELLANEOUS↗

CyOTE ASSET OWNER ENGAGEMENT – SIDE CHANNEL POWER ANALYSIS PROTOTYPE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently identify adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. The CyOTE methodology seeks to identify adversarial techniques within an AOO OT environment that could result in physical disruptions to energy flow or damage to equipment. CyOTE provides a general roadmap for AOOs, starting from a triggering event, or the point in time and space they perceive an anomalous event or condition meriting investigation, and culminating when the AOO has sufficient confidence to make a business risk decision on the appropriate resolution. This paper outlines the results of one such engagement with the New York Power Authority (NYPA), where the CyOTE program partnered with an AOO to develop a design specification for a power side channel detector to identify anomalous changes to device load. It describes the goal of developing this capability, the development process, the challenges the technical teams faced and the future steps an AOO will need to take to install and use this detector in its OT environment.

99 GENERAL AND MISCELLANEOUS↗

Dragonstone Strategy Kickoff Report [Slides]

The oil & natural gas (ONG) system like any other heavy industrial process, relies on a complex system of information technology (IT) and operational technology (OT) devices. Cyber-preparedness varies across the ONG industry from organization to organization. Common challenges include remote locations, long-lived field assets, and insufficient capabilities to find and track malware. ONG companies tend to be concerned with lack of cyber-awareness from employees, risk stemming from remote access for operations & maintenance, and software vulnerabilities within third-party equipment. For a variety of reasons, the general consensus from stakeholders interviewed by LLNL is that the state of cybersecurity within the electric grid is currently outpacing its ONG cousin. Existing strategies for the resilience and cybersecurity of the electric grid can and should be leveraged to provide immediate benefits to the ONG system. In LLNL’s view, there are two key factors currently limiting the development of necessary cyber-practices within the ONG industry: regulatory overlap and inefficiencies, and lack of industry awareness of potentially useful technologies for solving known issues. In the months following this report, LLNL will develop a cyber-resilience roadmap for the oil & gas pipeline sector, coupling threat intelligence, industry knowledge base, and ongoing outreach

02 PETROLEUM↗

Cyber Fire OT Class Presentation

This is a presentation for the Operational Technology Class to be used during Cyber Fire Foundry 17. Much of this training content has been used in other trainings that have already gone through the lab review system (CYBERSTRIKE, Ladder Logic, CSET). This presentation contains training content related to Operational Technology Cybersecurity topics.

99 GENERAL AND MISCELLANEOUS↗

Portable Industrial Control Systems Simulator (Final Report)

Industrial Control Systems (ICS) are more integrated than they have ever been before, but also the division between IT (Information Technology) and OT (Operational Technology) is becoming a grey area. As the integration of IT and OT occurs more often, cyber attack will also increase. Cyber attacks on Critical Infrastructure can be highly detrimental to society, notably via compromised Industrial Control Systems (ICS). Virtual and physical simulation has been used in medical fields, mathematics, architecture, aeronautics, space, and many more. Virtualization & Simulation in a lab environment is ideal because there is a need for the ability to test theories and designs is a safe and cost-effective way without risking equipment damage or, more importantly, human life. Furthermore, OT and ICS are some of the most difficult systems to use for research and development. They are either committed to operations or widely expensive to set up in a life-like environment. Virtualization and simulation will allow these otherwise accessible systems to be a test bed for the training, development, and research of SRNL customers or engineers and scientists at SRNL. This will allow the testbed to fit into a small form factor and interact with a simulator with minimum hardware components for easy transports and replication effort within the environment.

42 ENGINEERING↗

Real-World Cyber Security Demonstration for Networked Electric Drives

In this article, we present the design and implementation of a cyber-physical security testbed for networked electric drive systems, aimed at conducting real-world security demonstrations. To our knowledge, this is one of the first security testbeds for networked electric drives, seamlessly integrating the domains of power electronics and computer science, and cybersecurity. By doing so, the testbed offers a comprehensive platform to explore and understand the intricate and often complex interactions between cyber and physical systems. The core of our testbed consists of four electric machine drives, meticulously configured to emulate small-scale but realistic information technology (IT) and operational technology (OT) networks. This setup both provides a controlled environment for simulating a wide array of cyber-attacks, and mirrors potential real-world attack scenarios with a high degree of fidelity. The testbed serves as an invaluable resource for the study of cyber-physical security, offering a practical and dynamic platform for testing and validating cybersecurity measures in the context of networked electric drive systems. As a concrete example of the testbed's capabilities, we have developed and implemented a Python-based script designed to execute step-stone attacks over a wireless local area network (WLAN). This script leverages a sequence of target IP addresses, simulating a real-world attack vector that could be exploited by adversaries. To counteract such threats, we demonstrate the efficacy of our developed cyber-attack detection algorithms, which are integral to our testbed's security framework. Furthermore, the testbed incorporates a real-time visualization system using InfluxDB and Grafana, providing a dynamic and interactive representation of networked electric drives and their associated security monitoring mechanisms. This visualization component not only enhances the testbed's usability but also offers insightful, real-time data for researchers and practitioners, thereby facilitating a deeper understanding of cyber-physical security dynamics in networked electric drive systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Traffic Shaping to Traffic Engineering in Time-Sensitive OT Network

Modern industrial automation systems increasingly depend on network infrastructures for time-critical communication, driving the need for solutions that guarantee timely and reliable data delivery. IEEE 802.1 Time-Sensitive Networking (TSN) holds significant promise for converging Information Technology (IT) and Operational Technology (OT) networks, enabling interoperability and supporting the coexistence of mixed-critical traffic crucial for Industry 4.0 and IIoT. To achieve deterministic communication, TSN employs various traffic shapers such as the Time-Aware Shaper (TAS), Asynchronous Traffic Shaper (ATS), and Credit-Based Shaper (CBS). However, the effective deployment of TSN in industrial automation faces several challenges. These include the non-trivial mapping of diverse industrial traffic types to specific shapers, the complexity of optimizing shaper configurations. We present a model for effective traffic engineering within TSN enabled OT Network. Our experiments also demonstrate how shaping of certain traffic types get affected in absence of precise time synchronization and propose possible solutions based on experiment results. Based on our experimental results we provide recommendations on how traffic type assignments should be done and which traffic shaping mechanisms should be used for a particular traffic type.

Sarker, Taposh Kumer [University of Texas at El Pa↗

Bayesian Attack Model (BAM) User Story

This document presents a user story for the Bayesian Attack Model (BAM) tool designed to aggregate and analyze cyber-attack observables for operational technology (OT) systems. BAM aims to empower cybersecurity analysts by providing a streamlined interface for collecting observable data from various sources, enabling real-time analysis of potential adversary activity. By enhancing the response capabilities of security teams, BAM facilitates risk-informed decision-making and improves organizational security posture. This user story outlines the key functionalities, user interactions, and requirements necessary to successfully integrate BAM with other security information and event management (SIEM) technology and cybersecurity operations centers (CSOCs).

97 MATHEMATICS AND COMPUTING↗

User Guide to the Facility Cybersecurity Capability Maturity Model (F-C2M2) Assessment

The Facility Cybersecurity Capability Maturity Model (F-C2M2) assessment was designed to help facilities address their unique cybersecurity challenges. Building upon the foundational principles of the U.S. Department of Energy (DOE) Cybersecurity Capability Maturity Model (C2M2), the F-C2M2 was explicitly tailored for federal facilities to help evaluate, benchmark, and enhance the cybersecurity capabilities of both their information technology (IT) and operational technology (OT) environments. This user guide was developed to facilitate a thorough understanding of the tool. Whether users are familiar with the original C2M2 or are new to the maturity model concept, this guide was designed to offer clarity, direction, and support.