Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards

The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.

Burt, Eric A.↗

An X-ray shadowgraph to locate transient high-energy celestial sources

A new technique has been developed to locate strong, transient X-ray sources such as the recently discovered gamma ray bursts. The instrument, termed a shadowgraph, locates sources by detecting the X-ray shadow cast by a large occulting mask pattern on an imaging detector. Angular resolutions of from 2 to 10 arc minutes are obtainable while essentially full sky coverage is maintained. The optimum energy range of operation is between 20 keV and 100 keV. The high efficiency X-ray imaging detectors, which make it possible to locate bursts with intensities down to approximately 10 photons/sq cm sec, are capable of detecting single 20 keV photons with a spatial resolution of approximately 0.2 mm. The detectors consist of an X-ray to optical conversion phosphor, a multistage image intensifier, and a CCD image readout.

Fishman, G. J.↗

Charge injection device evaluation hardware

A microprocessor based system which provides maximum testing flexibility via software reconfiguration is described. This system has the capability to evaluate a charge injection device (CID) and to characterize its performance. The construction and operation of the CID offer advantages over the various CCD configurations available. These advantages include a less sophisticated manufacturing process, no images smearing during readout, high transfer efficiencies, and high resistance to blooming due to optical overload.

Source record↗

Solid state imagers and their applications; Proceedings of the Meeting, Cannes, France, November 26, 27, 1985

Topics treated include the use of semiconductor imagers in high energy particle physics, an X-ray image sensor based on an optical TDI-CCD imager, and an electron-sensitive CCD readout array for a circular-scan streak tube. Papers are presented on the pan-imager, high resolution linear arrays, the reduction of reflection losses in solid-state image sensors, a high resolution CCD imager module with swing operation, large area CCD image sensors for scientific applications, and new readout techniques for frame transfer CCDs. Consideration is given to advanced optoelectronical sensors for autonomous rendezvous/docking and proximity operations in space, the testing and characterization of CCDs for the Rosat star sensors, an advanced radial camera for the Hubble Space Telescope, and scanning or staring infrared imagers.

Declerck, Gilbert J.↗

The High Throughput X-ray Spectroscopy (HTXS) Mission

The HTXS mission concept combines large effective area (approximately 15,000 sq cm at 1 keV), high spectral resolution (E/Delta(E) approximately 300-3000), and broad energy bandpass (0.25-40 keV and possibly up to 100 keV) by using replicated optics together with a complement of spectroscopic instrumentation including reflection gratings readout by charge-coupled device detectors (CCDs), quantum micro-calorimeters, and cadmium zinc telluride (CZT) or comparable high energy detectors. An essential feature of this concept involves minimization of cost (approximately $350M for development and approximately $500-600M including launches) and risk by building six identical modest satellites to achieve the large area. Current mission and technology studies are targeted towards a new start in the 2002 timeframe, with first launch around 2005-2006. The HTXS mission represents a major advance, providing as much as a factor of 100 increase in sensitivity over currently planned high resolution X ray spectroscopy missions. HTXS will mark the start of a new era when high quality X ray spectra will be obtained for all classes of X ray sources, over a wide range of luminosity and distance. With its increased capabilities, HTXS will address many fundamental astrophysics questions such as the origin and distribution of the elements from carbon to zinc, the formation and evolution of clusters of galaxies, the validity of general relativity in the strong gravity limit, the evolution of supermassive black holes in active galactic nuclei, the details of supernova explosions and their aftermath, and the mechanisms involved in the heating of stellar coronae and driving of stellar winds.

White, N. E.↗

Infrared-Bolometer Arrays with Reflective Backshorts

Integrated circuits that incorporate square arrays of superconducting-transition- edge bolometers with optically reflective backshorts are being developed for use in image sensors in the spectral range from far infrared to millimeter wavelengths. To maximize the optical efficiency (and, thus, sensitivity) of such a sensor at a specific wavelength, resonant optical structures are created by placing the backshorts at a quarter wavelength behind the bolometer plane. The bolometer and backshort arrays are fabricated separately, then integrated to form a single unit denoted a backshort-under-grid (BUG) bolometer array. In a subsequent fabrication step, the BUG bolometer array is connected, by use of single-sided indium bump bonding, to a readout device that comprises mostly a superconducting quantum interference device (SQUID) multiplexer circuit. The resulting sensor unit comprising the BUG bolometer array and the readout device is operated at a temperature below 1 K. The concept of increasing optical efficiency by use of backshorts at a quarter wavelength behind the bolometers is not new. Instead, the novelty of the present development lies mainly in several features of the design of the BUG bolometer array and the fabrication sequence used to implement the design. Prior to joining with the backshort array, the bolometer array comprises, more specifically, a square grid of free-standing molybdenum/gold superconducting-transition-edge bolometer elements on a 1.4- m-thick top layer of silicon that is part of a silicon support frame made from a silicon-on-insulator wafer. The backshort array is fabricated separately as a frame structure that includes support beams and contains a correspond - ing grid of optically reflective patches on a single-crystal silicon substrate. The process used to fabricate the bolometer array includes standard patterning and etching steps that result in the formation of deep notches in the silicon support frame. These notches are designed to interlock with the support beams on the backshort-array structure to provide structural support and precise relative positioning. The backshort-array structure is inserted in the silicon support frame behind the bolometer array, and the notches in the frame serve to receive the support beams of the backshort-array structure and thus determine the distance between the backshort and bolometer planes. The depth of the notches and, thus, the distance between the backshort and bolometer planes, can be tailored to a value between 25 to 300 m adjusting only a few process steps. The backshort array is designed so as not to interfere with the placement of indium bumps for subsequent indium bump-bonding to the multiplexing readout circuitry

Miller, Timothy M.↗

Linear capacitive displacement sensor with frequency readout

A simple, inherently linear technique for measuring changes in the separation of the mirrors of an optical cavity is reported. The capacitor, made up of the reflective metallic coatings, is part of a feedback loop which adjusts the frequency of an oscillator to be proportional to the mirror separation. A linearity of 0.2 percent full scale was achieved for separations up to 0.5 mm with a resolution of 10 nm.

Fritsch, Klaus↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization of the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 145 mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device multiplexer readout. We describe the design, development, and performance of PIPER bolometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

A high accuracy all-angle gyroscope readout using quantized flux

Means are described to use SQUID magnetometer flux counting and the London moment of a spherical superconducting gyroscope to read out the gyroscope spin axis direction to an accuracy of at least 23 bits per quadrant. The system is discussed in analogy to optical fringe counting as applied to distance measurement. Several methods of applying both analog and digital SQUID magnetometers to the readout problem are given, as well as limitations on each. Described are two methods of increasing the flux available for measurement: magnetizing the gyroscope with a trapped field, and optimizing readout circuit inductances. Finally, the same principle on which the gyroscope readout is based is applied to a description of a high accuracy, flux counting, digital angle encoder.

Anderson, J. T.↗

Towards an Imaging Mid-Infrared Heterodyne Spectrometer

We are developing a concept for a compact, low-mass, low-power, mid-infrared (MIR; 5- 12 microns) imaging heterodyne spectrometer that incorporates fiber optic coupling, Quantum Cascade Laser (QCL) local oscillator, photomixer array, and Radio Frequency Software Defined Readout (RFSDR) for spectral analysis. Planetary Decadal Surveys have highlighted the need for miniaturized, robust, low-mass, and minimal power remote sensing technologies for flight missions. The drive for miniaturization of remote sensing spectroscopy and radiometry techniques has been a continuing process. The advent of MIR fibers, and MEMS techniques for producing waveguides has proven to be an important recent advancement for miniaturization of infrared spectrometers. In conjunction with well-established photonics techniques, the miniaturization of spectrometers is transitioning from classic free space optical systems to waveguide/fiber-based structures for light transport and producing interference effects. By their very nature, these new devices are compact and lightweight. Mercury-Cadmium-Telluride (MCT) and Quantum Well Infrared Photodiodes (QWIP) arrays for heterodyne applications are also being developed. Bulky electronics is another barrier that precluded the extension of heterodyne systems into imaging applications, and our RFSDR will address this aspect.

Hewagama, T.↗

Integrated infrared array technology

An overview of integrated infrared (IR) array technology is presented. Although the array pixel formats are smaller, and the readout noise of IR arrays is larger, than the corresponding values achieved with optical charge-coupled-device silicon technology, substantial progress is being made in IR technology. Both existing IR arrays and those being developed are described. Examples of astronomical images are given which illustrate the potential of integrated IR arrays for scientific investigations.

Goebel, J. H.↗

Integrated infrared array technology

An overview of integrated infrared (IR) array technology is presented. Although the array pixel formats are smaller, and the readout noise of IR arrays is larger than the corresponding values achieved with optical charge-coupled-device silicon technology, substantial progress is being made in IR technology. Both existing IR arrays and those being developed are described. Examples of astronomical images are given which illustrate the potential of integrated IR arrays for scientific investigations.

Goebel, J. H.↗

Rapid, Nondestructive Readout From Ferroelectric Memory

Proposed devices with nondestructive readout offer attractive alternatives for rugged, solid-state memories suitable for contactless optical addressing and parallel processing and for nonvolatile analog memories. Pulses of light from lasers induce photoresponses in ferroelectric capacitors. Magnitude and polarity of response of each capacitor indicates magnitude and polarity of remanent polarization which, in turn, represents datum stored in that memory cell.

Thakoor, Sarita↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization o[ the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 128mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device (SQUID) multiplexer readout. We describe the design, development, and performance of PIPER bo|ometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

Development of a unit cell for a Ge:Ga detector array

Two modules of gallium-doped germanium (Ge:Ga) infrared detectors with integrated multiplexing readouts and supporting drive electronics were designed and tested. This development investigated the feasibility of producing two-dimensional Ge:Ga arrays by stacking linear modules in a housing capable of providing uniaxial stress for enhanced long-wavelength response. Each module includes 8 detectors (1x1x2 mm) mounted to a sapphire board. The element spacing is 12 microns. The back faces of the detector elements are beveled with an 18 deg angle, which was proved to significantly enhance optical absorption. Each module includes a different silicon metal-oxide semiconductor field effect transistor (MOSFET) readout. The first circuit was built from discrete MOSFET components; the second incorporated devices taken from low-temperature integrated circuit multiplexers. The latter circuit exhibited much lower stray capacitance and improved stability. Using these switched-FET circuits, it was demonstrated that burst readout, with multiplexer active only during the readout period, could successfully be implemented at approximately 3.5 K.

Source record↗

Fabrication of an Absorber-Coupled MKID Detector

Absorber-coupled microwave kinetic inductance detector (MKID) arrays were developed for submillimeter and far-infrared astronomy. These sensors comprise arrays of lambda/2 stepped microwave impedance resonators patterned on a 1.5-mm-thick silicon membrane, which is optimized for optical coupling. The detector elements are supported on a 380-mm-thick micro-machined silicon wafer. The resonators consist of parallel plate aluminum transmission lines coupled to low-impedance Nb microstrip traces of variable length, which set the resonant frequency of each resonator. This allows for multiplexed microwave readout and, consequently, good spatial discrimination between pixels in the array. The transmission lines simultaneously act to absorb optical power and employ an appropriate surface impedance and effective filling fraction. The fabrication techniques demonstrate high-fabrication yield of MKID arrays on large, single-crystal membranes and sub-micron front-to-back alignment of the micro strip circuit. An MKID is a detector that operates upon the principle that a superconducting material s kinetic inductance and surface resistance will change in response to being exposed to radiation with a power density sufficient to break its Cooper pairs. When integrated as part of a resonant circuit, the change in surface impedance will result in a shift in its resonance frequency and a decrease of its quality factor. In this approach, incident power creates quasiparticles inside a superconducting resonator, which is configured to match the impedance of free space in order to absorb the radiation being detected. For this reason MKIDs are attractive for use in large-format focal plane arrays, because they are easily multiplexed in the frequency domain and their fabrication is straightforward. The fabrication process can be summarized in seven steps: (1) Alignment marks are lithographically patterned and etched all the way through a silicon on insulator (SOI) wafer, which consists of a thin silicon membrane bonded to a thick silicon handle wafer. (2) The metal microwave circuitry on the front of the membrane is patterned and etched. (3) The wafer is then temporarily bonded with wafer wax to a Pyrex wafer, with the SOI side abutting the Pyrex. (4) The silicon handle component of the SOI wafer is subsequently etched away so as to expose the membrane backside. (5) The wafer is flipped over, and metal microwave circuitry is patterned and etched on the membrane backside. Furthermore, cuts in the membrane are made so as to define the individual detector array chips. (6) Silicon frames are micromachined and glued to the silicon membrane. (7) The membranes, which are now attached to the frames, are released from the Pyrex wafer via dissolution of the wafer wax in acetone.

Brown, Ari↗

Pulsed-laser ranging

Pulsed rubidium laser range measurements with delayed sweep oscilloscope, and with digital readout system

RUBY LASER↗