Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Design of the High Rigidity Spectrometer at FRIB

A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies (≳100 MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. Here, the maximum magnetic rigidity of the HRS is 8 Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

Data and scripts associated with: “Burn severity and vegetation type control phosphorus concentration, molecular composition, and mobilization”

This data package is associated with the publication “Burn severity and vegetation type control phosphorus concentration, molecular composition, and mobilization” published in European Geophysical Union - Biogeosciences (Barnes et al. 2025). This study investigates how phosphorus (P) biogeochemistry is altered by burn severity in contrasting types of vegetation chars. This data package documents the workflow used to process and generate the main figures and statistics in the manuscript. The R scripts reference minimally processed P nuclear magnetic resonance (P-NMR) and X-ray absorption near edge structure (P-XANES) data, as well as fully processed data including total elemental composition of the solid chars, total elemental composition of the char leachates (particulate and aqueous phases), and leachate aqueous phase molybdate reactive P concentration. These source data and associated metadata can be found on ESS-DIVE at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1894135 (Grieger et al. 2022; v3). Files and scripts included in this data package finish the processing workflow for P-NMR and P-XANES data. These data can be used to gain a better understanding of bulk chemical changes in chars and their leachates, as well as detailed molecular changes to P. This data package is associated with the GitHub repository found at https://github.com/river-corridors-sfa/rcsfa-RC3-BSLE_P. This data package is comprised of a “data” folder and a series of data processing and analysis scripts. Details on how to recreate the workflow can be found in the Critical Details section of the readme and the “workflow_readme.md” file. The file-level metadata file (file ending in “flmd.csv”) lists all files contained in this data package and descriptions for each. The data dictionary (file ending in “dd.csv”) describes all tabular data columns and their respective definitions and units.

54 ENVIRONMENTAL SCIENCES↗

Tethered Balloon System (TBS) Instrument Handbook

The Tethered Balloon System (TBS) is an unmanned aerial system composed of a helium-filled balloon, tether, winch, and sensors. Individual components of the system may change with each flight based on the desired measurements, atmospheric conditions, and flight strategy. The TBS operates within the U.S. Department of Energy (DOE)’s R-2204 Restricted Airspace, which encompasses a two-nautical-mile radius centered on Oliktok Point, Alaska that is segmented by altitude into R-2204 Low (0-1,499’ MSL or 0-457 m MSL) and R-2204 High (1,500-6,999’ MSL or 457-2133 m MSL). The TBS may operate outside of R-2204 if allowed to do so under a Certificate of Authorization from the Federal Aviation Administration.

42 ENGINEERING↗

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS↗

Miniaturized integrated spectrometer using a silicon ring-grating design

We introduce and experimentally demonstrate a miniaturized integrated spectrometer operating over a broad bandwidth in the short-wavelength infrared (SWIR) spectrum that combines an add-drop ring resonator narrow band filter with a distributed Bragg reflector (DBR) based broadband filter realized in a silicon photonic platform. The contra-directional coupling DBR filter in this design consists of a pair of waveguide sidewall gratings that act as a broadband filter (i.e., 3.9 nm). The re-directed beam is then fed into the ring resonator which functions as a narrowband filter (i.e., 0.121 nm). In this scheme the free spectral range (FSR) limitation of the ring resonator is overcome by using the DBR as a filter to isolate a single ring resonance line. The overall design of the spectrometer is further simplified by simultaneously tuning both components through the thermo-optic effect. Moreover, several ring-grating spectrometer cells with different central wavelengths can be stacked in cascade in order to cover a broader spectrum bandwidth. This can be done by centering each unit cell on a different center wavelength such that the maximum range of one-unit cell corresponds to the minimum range of the next unit cell. This configuration enables high spectral resolution over a large spectral bandwidth and high extinction ratio (ER), making it suitable for a wide variety of applications.

42 ENGINEERING↗

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗

Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas

Here, we demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 10 18 W/cm 2 ) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 10 18 W/cm 2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (10 11 W/cm 2 ) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.

47 OTHER INSTRUMENTATION↗

Elastic scattering in the 12 N + 197 Au system at 𝐸 lab = 70 MeV

Halo structure is an interesting exotic configuration developed in some light weakly bound nuclei, where a valence particle orbits a nuclear core. Signatures of halo structure can be observed in the angular distributions of the elastic scattering induced by these nuclei at energies around the Coulomb barrier. There are some well-studied reactions with neutron-rich halo nuclei, such as 6 He and 11 Li . However, the information is scarce on the proton-rich side. Recent works confirm the halo structure in the 8B nuclei but still lack more experimental studies for other proton-halo candidates, such as 12 N and 17 F. In this work, we report experimental data for the elastic scattering of 12 N on 197 Au target at 𝐸 lab = 70 MeV. The 12 N is a proton-rich nucleus with proton separation energy 𝑆 𝑝 = 600 keV, which is higher than the 8 B (𝑆 𝑝 = 137 keV) and almost the same as the 17 F (𝑆 𝑝 = 601 keV). Data were obtained at the Cyclotron Institute of Texas A&M University where the 12 N radioactive beam was produced by the momentum achromatic recoil spectrometer. The calculation of the optical model was used to fit the measured angular distribution for the elastic scattering and to obtain the reaction cross section 𝜎 𝑅 . We also performed continuum discretized coupled-channel calculations to compare with the experimental data. The angular distribution of the elastic cross sections exhibits a suppression of the Fresnel peak. From the fitting of the optical model, we obtain the total reaction cross section, 𝜎 𝑅 = 1269 ± 41 mb. The agreement between the CDCC calculation and the experimental elastic scattering data is limited and the breakdown does not exhaust the measured 𝜎 𝑅 . The resulting reduced reaction cross section 𝜎 Red for 12 N + 197 Au is large and comparable to the one obtained for the 8 B + 208 Pb system. This suggests a strong decoupling of the valence proton from the core because of the low binding energy and a dynamic polarization effect. Here, more research is required to estimate the contribution of core excitation.

Elastic scattering reactions↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Performance of low-cost indoor air quality monitors for PM 2.5 and PM 10 from residential sources

Advances in particle sensor design and manufacturing have enabled the development of low-cost air quality monitors (LCMs). Here, the sensors use light scattering to estimate mass concentration and thus require evaluation for aerosols of varied composition and size distribution. We tested the performance of six LCMs designed for home use and having a retail price under US$300 in October 2018. We assessed their performance by comparing their output to reference PM 2.5 and PM 10 measurements from 21 common residential sources and from infiltrated outdoor PM 2.5 . Reference data were obtained by using gravimetric measurements to adjust time-resolved output from an aerosol spectrometer with both electrical mobility and optical particle sensors. Compared by linear regression to reference measurements, LCMs had negative intercepts and slopes of 1–2 for infiltrated outdoor PM 2.5 . Semi-quantitative responses (~50–200% of actual PM 2.5 ) were obtained for varied aerosols including minerals (ultrasonic humidifier, vacuuming, test dust); combustion products (incense, mosquito coil, extinguished candles); microwave popcorn; and cooking involving frying or grilling. LCMs had low or no response to sources for which all mass was in particles smaller than 0.25 μm, including steady candle flames and cooking without frying or grilling. PM 10 data from LCMs was more variable than PM 2.5 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part II - Autonomous Navigation

Nuclear sites across the Unites States and other nations in the world, are prone to extreme radiation effects. To understand the radiation hazards, plan the cleanup efforts; and to meet the quality standards and guidelines, it is important to accurately characterize any nuclear facility. One of the current methods in characterizing facilities is the use of advanced autonomous systems. These are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. Conventional methods of taking radiation measurements by hand within or around the containment areas, and analyzing the collected data to obtain the result are: Ineffective, Puts scientists at risk of Radiation, Not cost-effective. The platform uses the Robotic Operating Systems (ROS) to integrate multiple sensors seamlessly. It can operate near real time by using a distributed processing system to handle large amounts of data: Surrounding cameras, A multi-channel 3D Lidar, Manipulator arm, High-performance gamma-ray spectrometer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The impact of optical measurement techniques on measured aerosol particle size distributions

Ambient aerosol particle size distributions measured by the Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) at various sites around the world exhibit modes at optical diameters near 600 nm and 850 nm. These modes are not present in concurrent measurements with the Grimm 11-D Optical Particle Counter (OPC). Here, in this study, we argue that these modes result from the optical measurement technique itself, and we explain why they appear in measurements by the UHSAS but not in those by the Grimm OPC. We construct computer models of the UHSAS and Grimm (“digital UHSAS” and “digital Grimm”) and use these to investigate the size distribution that would result from measurements of artificial aerosol particle size distributions that do not contain modes. The appearance of modes for the structureless incoming size distributions sampled by the digital UHSAS is explained by the nonlinear behavior of partial scattering cross sections of uniform spherical particles as a function of their diameter. The absence of modes in the digital Grimm is explained by the coarser size resolution of that instrument. Detailed analysis of the relationship between optical and geometric diameters for uniform spherical particles reveals two important results. First, these diameters generally have different numerical values for the same particle, and second, the relationship is nonlinear; thus, widths of size bins in terms of optical diameter differ from those in geometric diameter. These results explain the modes observed in the ambient size distributions and highlight concerns with attempts to create a merged size distribution by combining measurements from different instruments.

54 ENVIRONMENTAL SCIENCES↗