Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscillator spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Instrumentation for submillimeter spectroscopy; Proceedings of the Meeting, Cannes, France, December 5, 6, 1985

The design and performance of spectroscopic instruments for submm-wave astronomy are discussed in reviews and reports. Topics examined include superconducting mixers, Schottky-diode mixers, local oscillators, antennas and quasi-optical components, spectrometry, and systems aspects. Special emphasis is given to candidate components for the 8-m heterodyne FIR and Submm Space Telescope being developed by ESA.

Kollberg, Eric↗

High Resolution UV Emission Spectroscopy of Molecules Excited by Electron Impact

Photodissociation via discrete line absorption into predissociating Rydberg and valence states is the dominant destruction mechanism of CO and other molecules in the interstellar medium and molecular clouds. Accurate values for the rovibronic oscillator strengths of these transitions and predissociation yields of the excited states are required for input into the photochemical models that attempt to reproduce observed abundances. We report here on our latest experimental results of the electron collisional properties of CO and N2 obtained using the 3-meter high resolution single-scattering spectroscopic facility at JPL.

James, G. K.↗

An All-Solid-State, Room-Temperature, Heterodyne Receiver for Atmospheric Spectroscopy at 1.2 THz

Heterodyne receivers at submillimeter wavelengths have played a major role in astrophysics as well as Earth and planetary remote sensing. All-solid-state heterodyne receivers using both MMIC (monolithic microwave integrated circuit) Schottky-diode-based LO (local oscillator) sources and mixers are uniquely suited for long-term planetary missions or Earth climate monitoring missions as they can operate for decades without the need for any active cryogenic cooling. However, the main concern in using Schottky-diode-based mixers at frequencies beyond 1 THz has been the lack of enough LO power to drive the devices because 1 to 3 mW are required to properly pump Schottky diode mixers. Recent progress in HEMT- (high-electron-mobility- transistor) based power amplifier technology, with output power levels in excess of 1 W recently demonstrated at W-band, as well as advances in MMIC Schottky diode circuit technology, have led to measured output powers up to 1.4 mW at 0.9 THz. Here the first room-temperature tunable, all-planar, Schottky-diode-based receiver is reported that is operating at 1.2 THz over a wide (≈20%) bandwidth. The receiver front-end (see figure) consists of a Schottky-diode-based 540 to 640 GHz multiplied LO chain (featuring a cascade of W-band power amplifiers providing around 120 to 180 mW at W-band), a 200-GHz MMIC frequency doubler, and a 600-GHz MMIC frequency tripler, plus a biasable 1.2-THz MMIC sub-harmonic Schottky-diode mixer. The LO chain has been designed, fabricated, and tested at JPL and provides around 1 to 1.5 mW at 540 o 640 GHz. The sub-harmonic mixer consists of two Schottky diodes on a thin GaAs membrane in an anti-parallel configuration. An integrated metal insulator metal (MIM) capacitor has been included on-chip to allow dc bias for the Schottky diodes. A bias voltage of around 0.5 V/diode is necessary to reduce the LO power required down to the 1 to 1.5 mW available from the LO chain. The epilayer thickness and doping profiles have been specifically optimized to maximize the mixer performance beyond 1 THz. The measured DSB noise temperatures and conversion losses of the receiver are 2,000 to 3,500 K and 12 to 14 dB, respectively, at 120 K, and 4,000 to 6,000 K and 13 to 15 dB, respectively, at 300 K. These results establish the state-of-the-art for all-solid-state, all-planar heterodyne receivers at 1.2 THz operating at either room temperature or using passive cooling only. Since no cryogenic cooling is needed, the receiver is eminently suited to atmospheric heterodyne spectroscopy of the outer planets and their moons.

Siles, Jose V.↗

STROBE-X: X-Ray Timing Spectroscopy on Dynamical Timescales from Microseconds to Years

We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER, with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT, to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with approx. 20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis.For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO and neutrino events. Additional extragalactic science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, is also obtained.

STROBE-X X-ray↗

STROBE-X: X-ray Timing & Spectroscopy on Dynamical Timescales from Milliseconds to Years

We describe a probe-class mission concept that provides an unprecedented view of the X-ray sky, performing timing and 0.2-30 keV spectroscopy over timescales from microseconds to years. The Spectroscopic Time-Resolving Observatory for Broadband Energy X-rays (STROBE-X) comprises three primary instruments. The first uses an array of lightweight optics (3-m focal length) that concentrate incident photons onto solid state detectors with CCD-level (85-130 eV) energy resolution, 100 ns time resolution, and low background rates to cover the 0.2-12 keV band. This technology is scaled up from NICER [1], with enhanced optics to take advantage of the longer focal length of STROBE-X. The second uses large-area collimated silicon drift detectors, developed for ESA's LOFT [2], to cover the 2-30 keV band. These two instruments each provide an order of magnitude improvement in effective area compared with its predecessor (NICER and RXTE, respectively). Finally, a sensitive sky monitor triggers pointed observations, provides high duty cycle, high time resolution, high spectral resolution monitoring of the X-ray sky with approx. 20 times the sensitivity of the RXTE ASM, and enables multi-wavelength and multi-messenger studies on a continuous, rather than scanning basis. For the first time, the broad coverage provides simultaneous study of thermal components, non-thermal components, iron lines, and reflection features from a single platform for accreting black holes at all scales. The enormous collecting area allows detailed studies of the dense matter equation of state using both thermal emission from rotation-powered pulsars and harder emission from X-ray burst oscillations. The combination of the wide-field monitor and the sensitive pointed instruments enables observations of potential electromagnetic counterparts to LIGO and neutrino events. Additional extragalactic science, such as high quality spectroscopy of clusters of galaxies and unprecedented timing investigations of active galactic nuclei, is also obtained

STROBE-↗

Quantifying the Influence of Redox Conditions on the Seismic Properties of Olivine

A series of eight olivine specimens were fabricated by hot-pressing at 1200 degrees Celsius and 300 megapascals (MPa). Each hot-pressed specimen was then wrapped in Pt, Ni or NiFe foil to vary oxygen fugacity (fO2), and interrogated via forced torsional oscillation. Mechanical testing was conducted at 10 oscillation periods between 1 and 1000 seconds, at a confining pressure of 200 MPa, during a slow staged-cooling from a maximum temperature of 1200 degrees Celsius to room temperature. After mechanical testing, each specimen was axially sectioned and EBSD (Electron BackScatter Diffraction) was used for the determination of the representative grain size, and grain size distribution of each sample. In addition, each longitudinal section was mapped via FTIR (Fourier Transform InfraRed spectroscopy) to determine the spatial distribution and concentrations of chemically bound and molecular water. Amongst these specimens, chemically bound ‘water’ contents were observed to vary between 0 and 1150 atom ppm (parts per million) H/Si, and molecular water concentrations varied between 0 and 245 atom ppm H/Si. Our forced-oscillation results demonstrate that the measured magnitude of anelastic relaxation within the experimental ‘window’ of oscillation periods is unrelated to the water content. Rather, a relationship was observed between the magnitude of anelastic relaxation and the prevailing redox conditions, which is influenced by the choice of metal sleeving used during the mechanical test. Further, regardless of water content or metal sleeving, each specimen exhibits coupled variations in shear modulus and dissipation within the observational window, indicative of ‘high-temperature background’ behavior, that can be described by a Burgers-type model. During initial fitting of the Burgers models, the unrelaxed shear modulus at a reference temperature of 900 degrees Celsius (G (sub UR)) and the temperature derivative of the unrelaxed shear modulus (dG (sub U)/dT), were treated as adjustable parameters. For all Fe-bearing olivine samples (but not a hydrous and oxidized Fe-free sample) we observe deficits of G (sub UR), and increased values of dG (sub U)/dT, relative to the expected elastic (anharmonic) behavior of Fo90 olivine. This behavior is indicative of anelastic relaxation occurring at shorter periods than observable within the ‘window’ of oscillation periods used in the mechanical test. Moving towards a comprehensive seismologically applicable Burgers model, which includes this newly observed effect of redox conditions on anelastic relaxation, we will present our progress in reconciling truly anharmonic and elastic behavior of Fo (sub 90) olivine with our observed forced-oscillation data.

Cline, Christopher, II↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure

High-resolution submillimeter/terahertz spectroscopy is important for studying atmospheric and interstellar molecular gaseous species. It typically uses heterodyne receivers where an unknown (weak) signal is mixed with a strong signal from the local oscillator (LO) operating at a slightly different frequency. The non-linear mixer devices for this frequency range are unique and are not off-the-shelf commercial products. Three types of THz mixers are commonly used: Schottky diode, superconducting hot-electron bolometer (HEB), and superconductor-insulation-superconductor (SIS) junction. A HEB mixer based on the two-dimensional electron gas (2DEG) formed at the interface of two slightly dissimilar semiconductors was developed. This mixer can operate at temperatures between 100 and 300 K, and thus can be used with just passive radiative cooling available even on small spacecraft.

Karasik, Boris S.↗

High resolution spectroscopy of the disk chromosphere. V - Space-time variations observed simultaneously in seven lines

Time sequence spectroscopic observations of the quiet solar chromosphere along a 200 Mm strip near the center of the disk were reduced to obtain 30 min of data. Oscillations appear in most of the observations in selected photospheric and chromospheric lines, but rarely in continuum observations. At a given point, the oscillations may be prominent or weak, they are never regular in time, and there is no unique relationship between the amplitudes at different heights. There are several examples of granules which apparently excite a burst of short period oscillations. By considering the line shift and intensity variations of all the lines, a working model is derived for the velocity field and related temperature variation.

Cram, L. E.↗

The Influence of Redox Conditions on the Seismic Properties of Polycrystalline Olivine

Eight olivine specimens were fabricated by use of a solgel method and hot-pressing at 1200 degrees Centigrade and 300 megapascals (MPa) inside of welded Pt capsules. Each hot-pressed specimen was then recovered, precision ground, and wrapped in Pt, Ni or NiFe foil to vary oxygen fugacity (fO2) during the subsequent forced torsional oscillation measurements. Mechanical testing was conducted at 10 oscillation periods between 1 and 1000 seconds, at a confining pressure of 200 MPa, during a slow staged-cooling from a maximum temperature of 1200 degrees Centigrade down to room temperature. After mechanical testing, each specimen was axially sectioned and EBSD (Electron BackScatter Diffraction) was used for the determination of the representative grain size, and grain size distribution of each sample. In addition, each longitudinal section was mapped via FTIR (Fourier Transform Infrared Spectroscopy) to determine the spatial distribution and concentrations of chemically bound and molecular water. Amongst these eight specimens, chemically bound ‘water’ contents were observed to vary between 0 and 1150 atom parts per million (ppm) H/Si, and molecular water concentrations varied between 0 and 245 atom ppm H/Si. Our forced-oscillation results demonstrate that the measured magnitude of anelastic relaxation within the experimental ‘window’ of oscillation periods is unrelated to the water content. Rather, a relationship was observed between the magnitude of anelastic relaxation and the prevailing redox conditions, which is influenced by the choice of metal sleeving used during the mechanical test. Further, regardless of water content or metal sleeving, each specimen exhibits coupled variations in shear modulus and dissipation within the observational window, indicative of ‘high-temperature background’ behavior, that can be described by a Burgers-type model. During initial fitting of the Burgers models, the unrelaxed shear modulus at a reference temperature of 900°C (elastic unloading/reloading shear modulus G (sub UR)) and the temperature derivative of the unrelaxed shear modulus (dGU/dT), were treated as adjustable parameters. For all Fe-bearing olivine samples we observe deficits of G (sub UR) and increased values of dGU/dT, relative to the expected elastic (anharmonic) behavior for Fo (Forsterite content percentage) (sub 90) olivine. This behavior is indicative of anelastic relaxation occurring at shorter periods than observable within the ‘window’ of oscillation periods used in the mechanical test. Moving towards a comprehensive and seismologically applicable Burgers model, which includes this newly observed effect of redox conditions on anelastic relaxation, we will present our progress on reconciling truly anharmonic and elastic behavior of Fo (sub 90) olivine with our observed forced-oscillation data.

Cline, C. J., II↗

The U.C. Berkeley Space Sciences Laboratory and Department of Physics Submillimeter Receiver

The UCB submm heterodyne receiver is a complete system for high-resolution astronomical spectroscopy in the 350-micron and 450-micron atmospheric windows. This compact system mounts directly at the Cassegrain focus of large optical and IR telescopes. It consists of a laser local oscillator, open structure mixer, quasi-optical coupling system, a broad-band IF system, and an acoustooptical spectrometer. The local oscillator is a 1-m-long submm laser optically pumped by a CO2 laser. The mixer is a quasi-optical corner-cube antenna structure and Schottky diode. The mixer is currently operated at room temperature, and its performance at 77 K is being evaluated. The system noise temperature is less than 7000 K SSB during observations.

Harris, A. I.↗

Auger analysis of a fiber/matrix interface in a ceramic matrix composite

Auger electron spectroscopy (AES) depth profiling was used to characterize the fiber/matrix interface of an SiC fiber, reaction bonded Si3N4 matrix composite. Depth profiles of the as received double coated fiber revealed concentration oscillations which disappeared after annealing the fiber in the environment used to fabricate the composite. After the composite was fractured, the Auger depth profiles showed that failure occurred in neither the Beta-SiC fiber body nor in the Si3N4 matrix but, concurrently, at the fiber coating/matrix interface and within the fiber coating itself.

Honecy, Frank S.↗

Auger analysis of a fiber/matrix interface in a ceramic matrix composite

Auger electron spectroscopy (AES) depth profiling was used to characterize the fiber/matrix interface of an SiC fiber, reaction bonded Si3N4 matrix composite. Depth profiles of the as received double coated fiber revealed concentration oscillations which disappeared after annealing the fiber in the environment used to fabricate the composite. After the composite was fractured, the Auger depth profiles showed that failure occurred in neither the Beta-SiC fiber body nor in the Si3N4 matrix but, concurrently, at the fiber coating/matrix interface and within the fiber coating itself.

Honecy, Frank S.↗

Observation of the visible absorption spectrum of H2O(+)

The water cation, H2O(+), has been studied, using laser absorption spectroscopy in a velocity-modulated discharge. It is shown that it is possible to observe the absorption spectrum of an ion that is not a terminal ion, despite the weak absorption oscillator strength, and despite the use of a relatively noisy dye laser. The relative intensities of the absorption lines have been measured to an accuracy of 13 percent. It is concluded that if the absorption cross section of a single transition can be measured absolutely, then the entire manifold will be known absolutely.

Das, Biman↗

Electronic absorption spectroscopy of matrix-isolated polycyclic aromatic hydrocarbon cations. II. The phenanthrene cation (C14H10+) and its 1-methyl derivative

The ultraviolet, visible, and near infrared absorption spectra of phenanthrene (C14H10), 1-methylphenanthrene [(CH3)C14H9], and their radical ions [C14H10+; (CH3)C14H9+], formed by vacuum-ultraviolet irradiation, were measured in neon matrices at 4.2 K. The associated vibronic band systems and their spectroscopic assignments are discussed. The oscillator strengths were calculated for the phenanthrene ion and found lower than the theoretical predictions. This study presents the first spectroscopic data for phenanthrene and its methyl derivative trapped in a neon matrix where the perturbation of the isolated species by its environment is minimum; a condition crucial to astrophysical applications.

NASA Discipline Exobiology↗

Electron impact excitation of coronene

A preliminary study of the electron-impact excitation of thermally evaporated coronene at 550 C was carried out using electron-energy-loss spectroscopy. Measurements of the energy-loss spectra of coronene at high (100 eV) and low (5-20 eV) impact energies are presented. One of the high-energy spectra was converted to an apparent generalized oscillator strength spectrum and compared to the photoabsorption spectrum of coronene. Observations concerning vibrational excitation of coronene by electron impact are also presented and discussed.

Khakoo, M. A.↗

Computational Spectroscopy of Polycyclic Aromatic Hydrocarbons In Support of Laboratory Astrophysics

Polycyclic aromatic hydrocarbons (PAHs) are strong candidates for the molecular carriers of the unidentified infrared bands (UIR) and the diffuse interstellar bands (DIBs). In order to test the PAH hypothesis, we have systematically measured the vibronic spectra of a number of jet-cooled neutral and ionized PAHs in the near ultraviolet (UV) to visible spectral ranges using the cavity ring-down spectroscopy. To support this experimental effort, we have carried out theoretical studies of the spectra obtained in our measurements. Ab initio and (time-dependent) density.functiona1 theory calculations are performed to obtain the geometries, energetics, vibrational frequencies, transition dipole moments, and normal coordinates of these PAH molecules. Franck-Condon (FC) calculations and/or vibronic calculations are then performed using the calculated normal coordinates and vibrational frequencies to simulate the vibronic spectra. It is found that vibronic interactions in these conjugated pi electron systems are often strong enough to cause significant deviations from the Born-Oppenheimer (BO) approximation. For vibronic transitions that are well described by the BO approximation, the vibronic band profiles are simulated by calculating the rotational structure of the vibronic transitions. Vibronic oscillator strength factors are calculated in the frame of the FC approximation from the electronic transition dipole moments and the FC factors. This computational effort together with our experimental measurements provides, for the first time, powerful tools for comparison with space-based data and, hence, a powerful approach to understand the spectroscopy of interstellar PAH analogs and the nature of the UIR and DIBs.

Tan, Xiaofeng↗

A Sub-THz CMOS Molecular Clock with 20 ppt Stability at 10,000 s Based on A Dual-Loop Spectroscopic Detection and Digital Frequency Error Integration

This paper presents a dual-loop chip-scale molecular clock (CSMC), which enhances the Allan Deviation performance by combining high signal-to-noise ratio of using fundamental mode and long-term stability of using higher order modes in derivative molecular absorption spectroscopy. In addition, digital frequency-error integration is adopted in the frequency-locked loop to provide an infinite open-loop DC gain, which fully suppresses any frequency drift caused by the temperature-sensitive crystal oscillator. This new generation CSMC is implemented in 65-nm CMOS, and achieves 20 ppt (part-per-trillion) Allan Deviation at 10,000 s averaging time with 71-mW power consumption.

Han, Ruonan↗