Search NASA⌕ Search

SEARCH · Search NASA

Results for “outdoor lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of Production Strains of Chlamydomonas Using Breeding Technologies

Chlamydomonas is a well-studied strain with excellent breeding capability. It can produce recombinant proteins in the raceway in the greenhouse. Increasing the pH of the culture resulted in a very stable cultivation process and cultures did not crash. This strain was not tolerant of high UV levels at KAF. This is can be probably easily overcome by breeding with a light tolerant strain. Overall Chlamydomonas is a very promising strain for production of recombinant proteins not only in the lab but also outdoors. It has excellent breeding capability and its progeny expressed the introduced protein for a long tiem. Chlamydomonas sp. produced lipids but overall lipid yield was low with highest lipid content of 15%. Chlamydomonas is a genus with a great potential for production of various specific proteins. It can be potentially cultivated outdoors and should be further investigated for production of specific molecules.

09 BIOMASS FUELS↗

60 GHz Outdoor Propagation Measurements and Analysis Using Facebook Terragraph Radios

The high attenuation of millimeter-wave (mmWave) would significantly reduce the coverage areas, and hence it is critical to study the propagation characteristics of mmWave in multiple deployment scenarios. In this work, we investigated the propagation and scattering behavior of 60 GHz mmWave signals in outdoor environments at a travel distance of 98 m for an aerial link (rooftop to rooftop), and 147 m for a ground link (light-pole to light-pole). Measurements were carried out using Facebook Terragraph (TG) radios. Results include received power, path loss, signal-to-noise ratio (SNR), and root mean square (RMS) delay spread for all beamforming directions supported by the antenna array. Strong line-of-sight (LOS) propagation exists in both links. We also observed rich multipath components (MPCs) due to edge scatterings in the aerial link, while only LOS and ground reflection MPCs in the other link.

60 GHz↗

Indoor and Outdoor Test Results for 'DUSST', a Low-Cost, Low-Maintenance PV Soiling Sensor

Soiling can cause significant losses to photovoltaic systems, and therefore it is often measured for the purposes of predicting long-term energy forecasts or for monitoring real time performance and triggering maintenance events as needed. Currently, the most common soiling monitoring technologies are soiling stations that use the electrical outputs of a regularly cleaned PV device and of a naturally soiled PV device to quantify soiling. As part of a new class of low-cost and low-maintenance soiling stations NREL has previously presented 'DUSST'. DUSST projects a collimated monochromatic light source through a glass surface (exposed similarly to the PV modules that need to be monitored) and on to a light detector to measure the intensity of the transmitted light. As the glass surface naturally soils, the losses are quantified by comparing this soiled reading with a calibrated reading under baseline clean condition. This work presents the ongoing improvement of DUSST and the ongoing indoor and outdoor validation of this new soiling sensor.

14 SOLAR ENERGY↗

An Open-Source Python Library for Modeling LETID and LID in Silicon Solar Cells and Wafers

This poster demonstrates an (in development) open-source software library, written in python, to aid in modeling and understanding light- and elevated temperature-induced degradation (LETID) and boron-oxygen light-induced degradation (B-O LID) in silicon solar cells and wafers. We discuss the underlying equations and necessary input parameters for constructing realistic models. We demonstrate several use cases for the library, including modeling LETID progression in scenarios like indoor, accelerated tests and outdoor field deployment. We also demonstrate using the library to model B-O LID, and we demonstrate using the library to model degradation in passivated wafers, rather than solar cells.

LETID↗

Biocontainment of Genetically Engineered Algae

Algae (including eukaryotic microalgae and cyanobacteria) have been genetically engineered to convert light and carbon dioxide to many industrially and commercially relevant chemicals including biofuels, materials, and nutritional products. At industrial scale, genetically engineered algae may be cultivated outdoors in open ponds or in closed photobioreactors. In either case, industry would need to address a potential risk of the release of the engineered algae into the natural environment, resulting in potential negative impacts to the environment. Genetic biocontainment strategies are therefore under development to reduce the probability that these engineered bacteria can survive outside of the laboratory or industrial setting. These include active strategies that aim to kill the escaped cells by expression of toxic proteins, and passive strategies that use knockouts of native genes to reduce fitness outside of the controlled environment of labs and industrial cultivation systems. Several biocontainment strategies have demonstrated escape frequencies below detection limits. However, they have typically done so in carefully controlled experiments which may fail to capture mechanisms of escape that may arise in the more complex natural environment. The selection of biocontainment strategies that can effectively kill cells outside the lab, while maintaining maximum productivity inside the lab and without the need for relatively expensive chemicals will benefit from further attention.

59 BASIC BIOLOGICAL SCIENCES↗

BETO 2021 Peer Review - 1.3.5.270 - Rewiring Algal Carbon Energetics for Renewables (RACER)

Critically needed improvements in biomass and biofuel intermediate productivity can be made by addressing fundamental inefficiencies in algal carbon conversion efficiency (CCE) to biofuel intermediates. Algae photosynthesis is, at best, able to convert 5-7% of incident light energy to biomass, while conversion to fuel intermediates falls 15-25% short of its maximum potential due to inefficiencies along the pathways. Recent progress in the Rewiring Algal Carbon Energetics (RACER) project consortium focused on a means to address the above inefficiencies in a pathway from algal biomass to a trifecta of fuel intermediates, ethanol, 2,3-butane diol, lipids and green biocrude. This project engineered a production-relevant algal species Desmodesmus armatus (SE 00107), to demonstrate biomass productivity improvements, with a doubling of the fuel intermediate yields. The new algae biorefinery paradigm embodied in RACER opens opportunities for algae engineering beyond efforts typically targeted solely at lipid content or improved light harvesting efficiency. Parallel approaches showed improved CCE through elimination of wasted energy during photosynthesis and increased carbon flux to transitory carbohydrate storage in the cells. Outdoor operation and nutrient management strategies with improvements in pretreatment, fermentation and extraction in a Combined Algal Processing approach showed a 40% reduction in MFSP, with a combined biofuel productivity of > 3700 gal/acre.

algal↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cas9 deletion of lutein biosynthesis in the marine alga Picochlorum celeri reduces photosynthetic pigments while sustaining high biomass productivity

Domestication of algae for food and renewable biofuels remains limited by the low photosynthetic efficiencies of processes that have evolved to be competitive for optimal light capture, incentivizing the development of large antennas in light-limiting conditions, thus decreasing efficient light utilization in cultivated ponds or photobioreactors. Reducing the pigment content to improve biomass productivity has been a strategy discussed for several decades and the ability to reduce pigment significantly is now fully at hand thanks to the widespread use of genome editing tools. Picochlorum celeri is one of the fastest growing marine algae identified and holds particular promise for outdoor cultivation, especially in saline water and warm climates. We show that while chlorophyll b is essential to sustain high biomass productivities under dense cultivation, removing Picochlorum celeri’s main carotenoid, lutein, leads to a decreased total chlorophyll content, higher a/ b ratio, reduced functional LHCII cross section and higher maximum quantum efficiencies at lower light intensities, resulting in an incremental increase in biomass productivity and increased PAR-to-biomass conversion efficiency. These findings further strengthen the existing strategies to improve photosynthetic efficiency and biomass production in algae.

59 BASIC BIOLOGICAL SCIENCES↗

Strong-Bonding Hole-Transport Layers Reduce Ultraviolet Degradation of Perovskite Solar Cells

The light-emitting diodes (LEDs) used in indoor testing of perovskite solar cells do not expose them to the levels of ultraviolet (UV) radiation that they would receive in actual outdoor use. We report degradation mechanisms of p-i-n-structured perovskite solar cells under unfiltered sunlight and with LEDs. Weak chemical bonding between perovskites and polymer hole-transporting materials (HTMs) and transparent conducting oxides (TCOs) dominate the accelerated A-site cation migration, rather than direct degradation of HTMs. An aromatic phosphonic acid, [2-(9-ethyl-9H-carbazol-3-yl)ethyl]phosphonic acid (EtCz3EPA), enhanced bonding at the perovskite/HTM/TCO region with a phosphonic acid group bonded to TCOs and a nitrogen group interacting with lead in perovskites. A hybrid HTM of EtCz3EPA with strong hole-extraction polymers retained high efficiency and improved the UV stability of perovskite devices, and a champion perovskite minimodule-independently measured by the Perovskite PV Accelerator for Commercializing Technologies (PACT) center-retained operational efficiency of >16% after 29 weeks of outdoor testing.

14 SOLAR ENERGY↗

Trait drift in microalgae and applications for strain improvement

Microalgae are increasingly used to generate a wide range of commercial products, and there is growing evidence that microalgae-based products can be produced sustainably. However, industrial production of microalgal biomass is not as developed as other biomanufacturing platform technologies. In addition, results of bench-scale research often fail to translate to large-scale or mass production systems. This disconnect may result from trait drift and evolution occurring, through time, in response to unique drivers in each environment, such as cultivation regimes, weather, and pests. Moreover, outdoor and indoor cultivation of microalgae has the potential to impose negative selection pressures, which makes the maintenance of desired traits a challenge. In this context, this review sheds the light on our current understanding of trait drift and evolution in microalgae. Here, we delineate the basics of phenotype plasticity and evolution, with a focus on how microalgae respond under various conditions. In addition, we review techniques that exploit phenotypic plasticity and evolution for strain improvement in view of industrial commercial applications, highlighting associated advantages and shortcomings. Finally, we suggest future research directions and recommendations to overcome unwanted trait drift and evolution in microalgae cultivation.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges, Technological Pathways and Trade-Offs of Perovskite Solar Modules for Long-Term Operation

Perovskite solar modules (PSMs) have emerged as a promising photovoltaic technology due to their high efficiency, low fabrication cost and compatibility with lightweight and flexible applications. However, ensuring long-term reliable performance under real-world conditions remains a critical barrier to commercialization. PSMs degrade through mechanisms that differ substantially from those affecting established technologies such as silicon, particularly under environmental stressors like ultraviolet light, oxygen, temperature cycling and reverse bias. Here we provide an analysis of the degradation pathways specific to perovskite modules and discuss why standard accelerated tests often fail to predict outdoor performance. We conceptualize challenges across material, device and module levels and evaluate strategies to mitigate ion migration, interfacial breakdown and encapsulation failure. By highlighting the need for realistic testing protocols and durable materials, we propose a framework highlighting key challenges, technological pathways and the trade-offs required to extend perovskite module lifetimes towards long-term operation, aiming to guide the development of PSMs capable of a 30-year operational lifetime.

14 SOLAR ENERGY↗

Outdoor Testing of c-Si Photovoltaic Modules with Spectrally-Selective Mirrors for Operating Temperature Reduction

The efficiency of a c-Si cell drops with increasing cell temperature. A typical photovoltaic module with a c-Si cell will operate 20-30K above ambient temperature. Spectrally-selective photonic mirrors which reflect sub-bandgap light can reduce waste heat generated by parasitic absorption in the module and reduce module operating temperature. Here, a spectrally selective 4-layer and 12-layer mirror are designed and fabricated on module cover glass. When integrated into modules, these mirrors reduce the operating temperature of the module by 0.16K and 1.5K, respectively when compared to a module with bare outer glass.

14 SOLAR ENERGY↗

Non-fullerene acceptor organic photovoltaics with intrinsic operational lifetimes over 30 years

Abstract Organic photovoltaic cells (OPVs) have the potential of becoming a productive renewable energy technology if the requirements of low cost, high efficiency and prolonged lifetime are simultaneously fulfilled. So far, the remaining unfulfilled promise of this technology is its inadequate operational lifetime. Here, we demonstrate that the instability of NFA solar cells arises primarily from chemical changes at organic/inorganic interfaces bounding the bulk heterojunction active region. Encapsulated devices stabilized by additional protective buffer layers as well as the integration of a simple solution processed ultraviolet filtering layer, maintain 94% of their initial efficiency under simulated, 1 sun intensity, AM1.5 G irradiation for 1900 hours at 55 °C. Accelerated aging is also induced by exposure of light illumination intensities up to 27 suns, and operation temperatures as high as 65 °C. An extrapolated intrinsic lifetime of > 5.6 × 10 4 h is obtained, which is equivalent to 30 years outdoor exposure.

14 SOLAR ENERGY↗

Perovskite solar cells can take the heat

Solar panels must endure extreme conditions during their service lifetime. There are few other products, let alone pristine semiconductor electronics, that are manufactured today and expected to withstand decades of abuse from full exposure to outdoor elements, including harsh ultraviolet sunlight, rain and hail, and daily and seasonal thermal cycles. Over the past decade, a new class of semiconductors, known as metal halide perovskites, has emerged, which constitutes the light-absorbing material in solar panels and has made incredible advancements, potentially taking photovoltaics in new directions. Perovskite materials have been touted as a potential game changer for solar energy production.

14 SOLAR ENERGY↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LeTID-Affected Cells from a Utility-Scale Photovoltaic System Characterized by Deep Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated temperature-induced degradation (LeTID). Samples of one of the affected monocrystalline silicon cells were cored and extracted from the module packaging and encapsulation. One of the cell fragments was processed using a regeneration cycle of applying short-circuit-rated current in forward bias at 85 degrees C for 2 weeks, while the other fragment was kept in its outdoor-degraded LeTID state. Both samples were scribed to form 2-mm diameter isolated areas using a femtosecond-pulse-width laser micromachining system. Both isolated areas contained front grid line segments which were wire bonded to larger contact pads, and the samples were probed in a cryostat linked to a deep-level transient spectroscopy (DLTS) system. Using DLTS, a majority-carrier, hole-trap defect was detected on each sample with an activation energy of 0.42 eV. The LeTID-degraded sample, however, had a larger signal corresponding to a trap density of 1.1x10^13 cm-3, which was about five times larger than the 2.1x10^12 cm-3 trap density of the regenerated sample.

charge carrier lifetime↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Improving energy yield in photovoltaic modules with photonic structures

When installed outdoors, Si solar cells typically operate 20 – 30 K above ambient conditions. These elevated operating temperatures lead to diminished performance, reducing efficiency by ~0.4%/K for crystalline Si cells and decreasing module lifetime. Since much of the elevated temperature of the modules derives from parasitic absorption of sub-bandgap sunlight by the contacts, encapsulants, or other materials, reflectors that remove the sub-bandgap radiation from the module before it is absorbed promise to reduce the operating temperature. However, there are many competing strategies to reject this light: selective reflectors could be integrated into the outer module glass, at the textured Si-encapsulant interface, or on the rear. Furthermore, many of these approaches are complex and expensive to fabricate. The issue of heating can be even more critical in bifacial modules: high fractions of rear irradiance can lead to higher operating temperatures. Prior to this project, relatively little was known about the optical strategies for temperature reduction in bifacial modules. The goal of this project was to quantitatively assess optical strategies for improving the energy yield via a combination of improved anti-reflection and sub-bandgap light rejection. We studied two complementary concepts: the performance of ideal structures to determine the upper limits to performance, and low-complexity structures made from standard materials as cost-effective implementations. We also studied the performance of these reflectors in different types of modules, including Al BSF, PERC, and bifacial. Here we build from our prior accomplishments in developing mirror optimization techniques, and make use of simulation methods that accurately capture the optical properties of the modules throughout the visible and near-infrared spectrum. We connect these optical properties to energy yield under realistic, outdoor conditions. We also experimentally fabricated mirrors, incorporated them into mini-modules, and performed outdoor testing of performance at NREL. We found definitively that spectrally-selective mirrors on the outside of the module cover glass offer the best performance, both under ideal conditions and for realistic, low- complexity mirrors. Mirrors at the Si cell/encapsulant interface are limited by the multiple reflections needed to remove sub-bandgap light. Mirrors at the cell surface and mirrors on the rear also cannot remove all the sub-bandgap light, since parasitic absorption also occurs in the cover glass, encapsulant, and front contacts, depending on the module configuration. Also, cell texturing places higher demands on any cell-surface mirror because multiple interactions with the mirror are required to reject sub bandgap light which compounds losses. For bifacial modules, mirrors on the back do provide additional cooling and energy yield improvements, and the mirrors can have the same structure. In the monofacial case up to 3.3K of cooling is possible for mirrors on the front, compared to 2.2K at the cell surface and 1.2K at the rear. For bifacial modules, up to 2.4K of cooling is possible when mirrors are included at both the front and back. Our realistic designs utilize 4 – 6 layers of common photovoltaic materials such as SiO 2 , TiO 2 , and SiN x , making them more cost effective. Finally, we used our models to study thermal management in bifacial modules with different back lamination materials, finding that glass-glass laminated modules operated hotter than equivalent glass-polymer backsheet modules, due solely to the increased absorption of light incident from the rear of the module. Improving the energy yield by 2%, which is achievable with these realistic designs, would lead to LCOE reductions of $0.03/kWh by 2030. These benefits make photovoltaic panels more accessible to the public and may reduce associated maintenance costs.

14 SOLAR ENERGY↗