At least 73 records · Page 4

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced diagnostics to evaluate heterogeneity in lithium-ion battery modules

Battery packs for electric and stationary applications experience varied operating conditions, including abuse—e.g., fast charging, overcharging, thermal, vibration, shock, etc.—throughout their lifetimes. Innovative diagnostic tools and algorithms that go beyond single cells and deal with modules and packs are essential for early detection of off-normal issues. High-resolution tools with known detection limits are key to developing appropriate mitigation strategies. With the advent of rapid impedance spectroscopy that can generate a broadband impedance spectrum in ~10 sec, the case for impedance-based diagnostics that can be readily aligned with other methods, such as incremental capacity or dQ.dV -1 , has become promising. This study used the aforementioned diagnostic methods to identify realistic in-vehicle battery abnormalities (e.g., localized self-discharge and non-uniform aging), in series (up to 10S) and parallel (4P) strings, using 16 Ah graphite/NMC cells. The impedance-based diagnostic is found to be sensitive to the string size and state. Depending on the type of abnormality, detection frequency varied. The dQ.dV -1 method showed the potential to detect long-term aging-related heterogeneity in modules. In general, both the impedance and dQ.dV -1 methods were able to detect series strings’ abnormalities, but struggled to find those issues within parallel modules.

25 ENERGY STORAGE↗

Ion Distribution and Cation Exchange at Mica–Electrolyte Interfaces Probed with Deep Potential Molecular Dynamics

Here, we investigate the Stern layer structure and cation exchange mechanism at muscovite mica-electrolyte interfaces using nanosecond timescale molecular dynamics simulations based on deep neural network interatomic potentials trained on Density Functional Theory (DFT) data. Focusing on mica with exposed surface K + interfaced with aqueous NaCl and mica with surface Na + interfaced with KCl solution, we find that K + remains predominantly in inner-sphere configurations, while Na + exhibits notable populations in outer-sphere states. Most importantly, our simulations show that contact with an electrolyte solution results in the co-adsorption of multiple cation species, making the mica surface locally overcharged and thus reshaping the cation speciation in a manner that enhances the tendency of neighboring surface cations to desorb. These findings are consistent with recent experimental observations that co-adsorption of different cation species induces changes in cation speciation and slow kinetics of cation exchange at the muscovite-water interface, providing a basis for their detailed understanding.

36 MATERIALS SCIENCE↗

Heavy Versus Light Lanthanide Selectivity for Graphene Oxide Films is Concentration Dependent

Rare earths are important materials in various technologies such as catalysis and optoelectronics. Graphene oxide (GO) is a promising material for separation applications, including the isolation of lanthanides from complex mixtures. Previous works using fatty acid monolayers have demonstrated preferential heavy versus light lanthanide adsorption, which has been attributed to differences in lanthanide ion size. In this work, we used interfacial X-ray fluorescence measurements to reveal that GO thin films at the air/water interface have no lanthanide selectivity for dilute subphases. However, at high subphase concentrations, ~8 times more Lu is adsorbed than La. By comparing the GO results with an ideal monolayer with a carboxylic acid headgroup, arachidic acid (AA), we demonstrate that the number of Lu ions adsorbed to GO is significantly higher than the number expected to compensate for the surface charge. Vibrational sum frequency generation (SFG) spectroscopy results on both GO thin films and AA monolayers reveal a red-shifted SFG signal in the OH region, which we attribute to partial dehydration of the adsorbed ions and carboxylic acid headgroups. Liquid surface X-ray reflectivity data show that the GO thin film structure does not significantly change between the very dilute and concentrated subphases. We speculate that the functional groups of both GO and AA facilitate cation dehydration, which is essential for ion adsorption. Heavy lanthanide Lu has stronger ion–ion correlations that can overcome the electrostatic repulsion between cations at higher concentrations compared to light lanthanide La, meaning GO and AA can exhibit apparent overcharge with Lu. Lastly, the layered structure of the GO films and reactive chemical nature of GO itself can accommodate ion adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating Trivalent Ion Adsorption at Floating Carboxylic Acid Monolayers: Charge Reversal or Water Reorganization?

Here we study the adsorption of trivalent neodymium on floating arachidic acid films at the air–water interface by two complementary surface specific probes, sum frequency generation spectroscopy and X-ray fluorescence near total reflection. In the absence of background ions, neodymium ions compensate for the surface charge of the arachidic acid film at a bulk concentration of 50 μM without any charge reversal. Increasing the bulk concentration to 1 mM does not change the neodymium surface coverage but affects the interfacial water structure significantly. In the presence of a high concentration of NaCl, there is overcharging at 1 mM Nd 3+ , i.e., 30% more Nd 3+ than needed to compensate for the surface charge. These results show that the total coverage of neodymium ions is not enough to describe the complete picture at the interface, and interfacial water and ion coverage needs to be considered together to understand more complex ion adsorption and transport processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic Insights into the Interplay between Ion Intercalation and Water Electrolysis in Aqueous Batteries

Improving electrolyte stability to suppress water electrolysis represents a basic principle for designing aqueous batteries. Herein, we investigate counterintuitive roles that water electrolysis plays in regulating intercalation chemistry. Using the Na x Fe[Fe(CN) 6 ]∥NaTi 2 (PO 4 ) 3 (x < 1) aqueous battery as a platform, we report that high-voltage overcharging can serve as an electrochemical activation approach to achieving concurrent Na-ion intercalation and an electrolytic oxygen evolution reaction. When the cell capacity is intrinsically limited by deficient cyclable Na ions, the electrolytic water oxidation on the cathode allows for extra Na-ion intercalation from the electrolyte to the NaTi 2 (PO 4 ) 3 anode, leading to a major increase in cyclable Na ions and specific capacity. Furthermore, the parasitic oxygen generation and potential transition-metal dissolution, as proved by our synchrotron and imaging tools, can be significantly mitigated with a simple reassembling approach, which enables stable electrochemical performance and sheds light on manipulating ion intercalation and water electrolysis for battery fast charging and recycling.

25 ENERGY STORAGE↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Electrochemical Decomposition of Primary Alcohol Groups in Deep Eutectic Solvents

This work investigates the electrochemical decomposition of an ethylene glycol/sodium chloride electrolyte and a deep eutectic solvent (DES) comprised of ethylene glycol/choline chloride (ethaline). Understanding these reactions can help to better understand the safety risks of overcharge when these electrolytes are used in a battery and to guide the design of DES electrolytes for improved electrochemical stability. Analysis of the decomposition products was performed using a combination of coulometry, gas chromatography, mass spectrometry, and Fourier transform infrared spectroscopy. It was found that even at relatively low (mM) concentrations of water, a stoichiometric rate of hydrogen is produced under cathodic conditions in both the ethaline and EG/NaCl electrolytes. This suggest an electrochemical hydrolysis cathodic decomposition reaction that produces both hydrogen gas and hydroxyl ions. This reaction was verified in both electrolytes by also identifying the liquid phase products. Only liquid phase products were observed under anodic conditions. A suspected alcohol oxidation to aldehyde anodic decomposition reaction was confirmed through a similar analysis of products. A tertiary alcohol only DES was investigated to eliminate these decomposition paths and was found to have increased stability window compared to the primary alcohol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Testing Method on Safety Assessment of Aged Li-Ion Cells: Part II – Aged Cells Without Li Plating

Understanding the safety profile of aged Li-ion batteries is essential for developing effective battery management and hazard mitigation strategies. However, most safety assessments have focused on fresh batteries, with just a few calorimetry studies on aged batteries with metal oxide positive electrodes. This study provides a broad assessment of commercial 18650-type Li-ion batteries with NCA, NMC, and LFP positive electrodes, both uncycled and aged under conditions that promoted solid electrolyte interphase (SEI) growth as the dominant degradation mechanism. The cells underwent mechanical (nail penetration, crush), electrical (overcharge, overdischarge), and thermal (accelerating rate calorimetry) abuse tests. Safety was rated on general characteristics such as mass loss, maximum temperature, and EUCAR (European Council for Automotive R&D) hazard level, as well as characteristics specific to individual abuse tests. Generally, aged cells with SEI growth exhibited similar or improved safety compared to uncycled cells, contrasting with our previous findings on NCA cells with Li plating as the dominant aging mechanism (Part I of this series). Yet, some tests and characteristics indicated reduced aged cell safety, such as earlier triggering of mechanical failure. These results emphasize the need to examine aged battery safety across diverse empirical techniques, degradation modes, and chemistries.

Lithium-ion cells↗

Advanced LiFSI-LiPF6 Electrolyte for Wide-Temperature and Thermally Stable Lithium-Ion Batteries

A new optimized LiFSI–LiPF6 dual-salt controlled-solvation electrolyte (E-DS) is demonstrated to enable practical graphite||LiNi0.8Mn0.1Co0.1O2 cells (˜4.0 mAh cm?²) to achieve exceptional performance and safety under extreme conditions. By optimizing anion coordination with the smaller, more dissociating FSI? anion, the E-DS forms ultrathin, dense, and inorganic-rich electrode/electrolyte interphases that dramatically suppress solvent decomposition, transition-metal dissolution, and surface reconstruction compared to the conventional LiPF6/carbonate electrolyte. Consequently, E-DS cells deliver >78% capacity retention after 300 cycles at 60 °C, retain fast discharging capacity at 30 °C, and operate effectively at -20 °C. Most strikingly, fully charged full cells with E-DS, even under overcharging to 4.8 V, show a lower heat evolution in stable formulations — transforming a traditionally unstable high-voltage/high-temperature configuration into an intrinsically safe state. This work establishes a new benchmark for carbonate-containing electrolytes, simultaneously achieving high energy density, fast-discharging capability, wide-temperature operation (-20 to 60 °C), and outstanding thermal safety in nickel-rich lithium-ion batteries.

electrode/electrolyte interphase↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Investigation of Fe-Ni Battery/Module for Grid Service Duty Cycles

Iron–nickel (Fe-Ni) batteries are renowned for their durability and resilience against overcharging and operating temperatures. However, they encounter challenges in achieving widespread adoption for energy storage applications due to their low efficiency and the need for regular maintenance and electrolyte replacement, which adds to maintenance costs. This study evaluates and demonstrates the capabilities of Fe-Ni batteries for participating in grid energy storage applications. Stable performance was observed frequency regulation (FR) testing at 100% and 50% state of charge (SOC)s, while at 50% SOC, there was a 14% increase in efficiency compared to 100% SOC. Although 25% SOC achieved higher efficiency, limited cyclability was observed due to reaching the discharge cutoff voltage. Optimal SOC selection, battery monitoring, maintenance, and appropriate charging strategies of Fe-Ni batteries seem to be crucial for their FR applications. Fe-Ni batteries exhibit stable peak shaving (PS) results, indicating their suitability and reliability under various load conditions for PS testing. Extended cycling tests confirm their potential for long-term grid-scale energy storage, enhancing their appeal for PS and FR applications.

25 ENERGY STORAGE↗

Interphase Engineering Enabled by Using a Separator with Electrochemically Active Carbazole Polymers for Lithium-Ion Batteries

Separators are generally considered inert components in lithium-ion batteries. In the past, some electroactive polymers have been successfully applied in separator modifications for overcharge protection or as acid scavengers. This study highlights the first use of two “electroactive” carbazole polymers (copolymer 9-phenyl-9H-carbazole-phenyl [PCP] and poly(9-vinylcarbazole) [PVC]), which were each applied separately as coatings on the cathode-facing side of commercial Celgard 2325 separators, respectively, to enhance the cycling performance of 0.3Li 2 MnO 3 ·0.7LiMn 0.5 Ni 0.5 O 2 //graphite (LMR-NM//Gr) full cells through interphase engineering. The team observed an irreversible polymer oxidation process of the carbazole-functionalized polymers—occurring only during the first charge—for the modified separator cells, and the results were confirmed by dQ/dV analysis, cyclic voltammetry measurements, and nuclear magnetic resonance characterizations. During this oxidation, carbazole polymers participate in the process of interphase formation, contributing to the improved cycling performance of LMR-NM//Gr batteries. Particularly, oxidation takes place at voltages of ~4.0 and ~3.5 V when PCP and PVC are used as separator coatings, which is highly irreversible. Further postmortem examinations suggest that the improvements using these modified separators arise from the formation of higher-quality and more inorganic SEI, as well as the beneficial CEI enriched in LixPOyFz. These interphases effectively inhibit the crosstalk effect by reducing TM dissolution.

carbazole↗

Nickel-cadmium cells for the spacecraft battery

The storage battery for the Telstar satellite must undergo frequent charge-discharge cycles; in addition, it is subject to overcharge during a substantial portion of its life. Nickel-cadmium cells were chosen as best capable of satisfactory long-time operation under these conditions. A design and selection program was undertaken to ensure that Ni-Cd cores would meet objectives imposed by battery service conditions, and the cell enclosure was designed to minimize electrolyte leakage. Selection, qualification, and life tests indicated that a storage battery using the cell design would perform satisfactorily. To date, the only failures occurring during continuing life tests have been among cells subjected to 100 per cent discharge daily; this operation is far in excess of the expected duty cycle of satellite cells.

TELSTAR SATELLITE↗