Search NASA⌕ Search

SEARCH · Search NASA

Results for “particle image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Three-Dimensional Imaging Lidar for Characterizing Particle Fields and Organisms in the Mesopelagic Zone

The ocean’s mesopelagic zone is largely uncharacterized despite its vital role in sustaining ocean ecosystems. The composition, cycling, and fate of particle fields in the mesopelagic lacks an integrative multi-scale understanding of organism migration patterns, distribution, and diversity. This problem is addressed by combining complementary technologies with overlapping size spectra, including profiler mounted optical scattering sensors, profiler, and ship mounted acoustic devices, and a custom Unobtrusive Multi-Static Lidar Imager (UMSLI). This unique sensor suite can observe distributions of particles including organisms over a six order of magnitude dynamic size range, from microns to meters. Overlapping size ranges between different methods allows for cross-validation. This work focuses on the lidar imaging measurements and optical backscattering and attenuation, covering a combined particle size range of 0.1 mm to several cm. Particles at the small end of this range are sized using an existing backscattering time series inversion method after Briggs et al. (2013). Larger particles are resolved with UMSLI over an expanding volume using three-dimensional photo-realistic laser serial imaging. UMSLI’s image rectifying ability over time allows for derivation of particle concentration, size, and spatial distribution. Technical details on the development and post-processing methods for the novel UMSLI system are provided. Image resolved particle size distributions (PSDs) revealed a size shift from smaller to larger particles (>0.5 mm) as indicated by flatter slopes from dawn (slope = 2.6) to dusk (slope = 3.0). PSD trends are supported by an optical backscatter and transmissometer time series inversion analysis. Size shifts in the particle field are largely attributed to aggregation effects. Images support evidence of temporal variation between dusk and dawn stations through statistical analysis of particle concentrations for particle sizes 0.50–5.41 mm. Spatial analysis of the particle field revealed a dominantly uniform distributed marine snow background. The importance and potential of integrated approaches to studying particle and organism dynamics in ocean environments are discussed.

54 ENVIRONMENTAL SCIENCES↗

Dosimetry of heavy ions by use of CCD detectors

The design and the atomic composition of Charge Coupled Devices (CCD's) make them unique for investigations of single energetic particle events. As detector system for ionizing particles they detect single particles with local resolution and near real time particle tracking. In combination with its properties as optical sensor, particle transversals of single particles are to be correlated to any objects attached to the light sensitive surface of the sensor by simple imaging of their shadow and subsequent image analysis of both, optical image and particle effects, observed in affected pixels. With biological objects it is possible for the first time to investigate effects of single heavy ions in tissue or extinguished organs of metabolizing (i.e. moving) systems with a local resolution better than 15 microns. Calibration data for particle detection in CCD's are presented for low energetic protons and heavy ions.

Schott, J. U.↗

X-Ray Microtomography Measurements of Coevolving Particle Size and Shape

This study measures simultaneous changes in particle size and shape during grain crushing and proposes quantitative metrics to track their coevolving statistical distribution. Idealized granular materials with widely different initial particle shapes (i.e., spheres, quasi-ellipsoids, plates, and rods) are compressed oedometrically at vertical stress levels sufficient to induce particle breakage. X-ray microtomography and digital image analysis are then used to track changes in particle-scale characteristics. The observations indicate that more irregular particles tend to exhibit a higher degree of breakage compared to more spherical grains subjected to an equivalent stress level. Despite these differences, the measurements also indicate that all the tested particle sets approach a common attractor (expressed in terms of aspect ratio, flatness, and elongation), regardless of their initial morphology. A new shape evolution index is proposed to quantify such trends. With this new metric, it is shown that in all the tested materials, the particle shape evolves faster than size, especially for the more regular morphologies, thus implying that the shape tends to reach its attractor point before the grading reaches its ultimate particle size distribution. Furthermore, this finding underpins an ultimate stage of crushing-driven compression that occurs with particle size reduction but minimal shape changes (i.e., self-replicating shapes due to fractures).

Oedometric compression↗

Automated reduction of instantaneous flow field images

An automated data reduction system for the analysis of interference fringe patterns obtained using the particle image velocimetry technique is described. This system is based on digital image processing techniques that have provided the flexibility and speed needed to obtain more complete automation of the data reduction process. As approached here, this process includes scanning/searching for data on the photographic record, recognition of fringe patterns of sufficient quality, and, finally, analysis of these fringes to determine a local measure of the velocity magnitude and direction. The fringe analysis as well as the fringe image recognition are based on full frame autocorrelation techniques using parallel processing capabilities.

Reynolds, G. A.↗

Particle displacement tracking for PIV

A new Particle Imaging Velocimetry (PIV) data acquisition and analysis system, which is an order of magnitude faster than any previously proposed system has been constructed and tested. The new Particle Displacement Tracing (PDT) system is an all electronic technique employing a video camera and a large memory buffer frame-grabber board. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine velocity vectors. Application of the PDT technique to a counter-rotating vortex flow produced over 1100 velocity vectors in 110 seconds when processed on an 80386 PC.

Wernet, Mark P.↗

Quantitative image analysis of laminin immunoreactivity in skin basement membrane irradiated with 1 GeV/nucleon iron particles

We previously reported that laminin immunoreactivity in mouse mammary epithelium is altered shortly after whole-body irradiation with 0.8 Gy from 600 MeV/nucleon iron ions but is unaffected after exposure to sparsely ionizing radiation. This observation led us to propose that the effect could be due to protein damage from the high ionization density of the ion tracks. If so, we predicted that it would be evident soon after radiation exposure in basement membranes of other tissues and would depend on ion fluence. To test this hypothesis, we used immunofluorescence, confocal laser scanning microscopy, and image segmentation techniques to quantify changes in the basement membrane of mouse skin epidermis. At 1 h after exposure to 1 GeV/nucleon iron ions with doses from 0.03 to 1.6 Gy, neither the visual appearance nor the mean pixel intensity of laminin in the basement membrane of mouse dorsal skin epidermis was altered compared to sham-irradiated tissue. This result does not support the hypothesis that particle traversal directly affects laminin protein integrity. However, the mean pixel intensity of laminin immunoreactivity was significantly decreased in epidermal basement membrane at 48 and 96 h after exposure to 0.8 Gy 1 GeV/nucleon iron ions. We confirmed this effect with two additional antibodies raised against affinity-purified laminin 1 and the E3 fragment of the long-arm of laminin 1. In contrast, collagen type IV, another component of the basement membrane, was unaffected. Our studies demonstrate quantitatively that densely ionizing radiation elicits changes in skin microenvironments distinct from those induced by sparsely ionizing radiation. Such effects may might contribute to the carcinogenic potential of densely ionizing radiation by altering cellular signaling cascades mediated by cell-extracellular matrix interactions.

Non-NASA Center↗

U Metal Oxidation with Steam (U)

The Savannah Rive National Laboratory 9SRNL) is evaluating a method to produce uranium oxide (UO 2 ) from uranium metal using steam. The typical methods for making UO 2 yield powders with particle-size ranges of 1 to 50 micron. The goal of the steam oxidation is to produce a depleted uranium (DU) product with a larger particle size that can be used as a surrogate for testing physical and mechanical process techniques to refine uranium and/or plutonium bearing residues. Several studies in the literature indicated that reactions between uranium metal and steam will yield UO 2 as fine powders in the 160 to 500 °C range, but granular materials form above 500°C. Above 880 °C, a hard compact scale forms on the U metal. Furthermore, sintering of UO 2 occurs at about 1300 °C, but it has been stated that the presence of steam enhances the sintering characteristics of UO 2 . Initial studies into the oxidation of DU metal in an atmosphere of argon and steam have been completed. Oxidation of depleted uranium metal in Ar/steam at 600, 710, 700, and 830 °C yielded at UO 2 product with little or no impurity at each temperature. Although not enough sample was available to perform sieve analysis for particle size distribution, SEM images reveal that a significant volume fraction of the products at 710, 770, and 830 °C exceeds 100 microns. The material produced at 600 °C was too fine for programmatic needs. Questions associated with the UO 2 include morphology of product, mechanical strength of the particles, and performance in milling operations. The size of the samples produced in these tests did not allow for quantitative assessment of particle size of mechanical strength. A qualitative assessment of the particles formed at 710, 770, and 830 °C was that the samples produced at 710 and 770 °C were friable, and the sample produced 830 °C had more mechanical strength. Sintering of the samples in Ar/steam at 970 °C appeared to increase the strength of the particles without changing their general particle size characteristics. Due to the small sample sizes, the increase in strength could not be quantified. If the sintering at 970 °C is inadequate, higher sintering temperatures in Ar/steam can be evaluated. Future work will increase scale of the steam oxidation conditions which yield the most-favorable particle-size distributions with sufficient mechanical strength for programming usage. Further consideration will be given to oxidation temperature, steam addition to the reaction vessel, U metal pretreatment, and sintering conditions after oxidation. The UO 2 production could involve a two-step process where particles are formed in steam at lower temperatures (700-850 °C) and then sintered in Ar/steam at elevated temperatures (950-1200 °C). Larger samples (50-100 g each) will provide sufficient UO 2 product for sieve analysis and assessment of mechanical strength relatives to subsequent milling operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High–Performance NiCo 2 O 4 /Graphene Quantum Dots for Asymmetric and Symmetric Supercapacitors with Enhanced Energy Efficiency

For the sustainable growth of future generations, energy storage technologies like supercapacitors and batteries are becoming more and more common. However, reliable and high-performance materials’ design and development is the key for the widespread adoption of batteries and supercapacitors. Quantum dots with fascinating and unusual properties are expected to revolutionize future technologies. However, while the recent discovery of quantum dots honored with a Nobel prize in Chemistry, their benefits for the tenacious problem of energy are not realized yet. In this context, herein, chemical-composition tuning enabled exceptional performance of NiCo 2 O 4 (NCO)/graphene quantum dots (GQDs) is reported, which outperform the existing similar materials, in supercapacitors. A comprehensive study is performed on the synthesis, characterization, and electrochemical performance evaluation of highly functional NCO/GQDs in supercapacitors delivering enhanced energy efficiency. The high-performance, functional NCO/GQDs electrode materials are synthesized by the incorporation of GQDs into NCO. The effect of variable amount of GQDs on the energy performance characteristics of NCO/GQDs in supercapacitors is studied systematically. In-depth structural and chemical bonding analyses using X-ray diffraction (XRD) and Raman spectroscopic studies indicate that all the NCO/GQDs composites crystallize in the spinel cubic phase of NiCo 2 O 4 while graphene integration evident in all the NCO/GQDs. The scanning electron microscopy imaging analysis reveals homogeneously distributed spherical particles with a size distribution of 5–9 nm validating the formation of QDs. The high-resolution transmission electron microscopy analyses reveal that the NCOQDs are anchored on graphene sheets, which provide a high surface area of 42.27 m 2 g –1 and high mesoporosity for the composition of NCO/GQDs-10%. In addition to establishing reliable electrical connection to graphene sheets, the NCOQDs provide reliable 3D-conductive channels for rapid transport throughout the electrode as well as synergistic effects. Chemical-composition tuning, and optimization yields NCO/GQDs-10% to deliver the best specific capacitance of 3940 Fg –1 at 0.5 Ag –1 , where the electrodes retain ≈98% capacitance after 5000 cycles. The NCO/GQD-10%//AC asymmetric supercapacitor device demonstrates outstanding energy density and power density values of 118.04 Wh kg –1 and 798.76 W kg –1 , respectively. The NCO/GQDs-10%//NCO/GQDs-10% symmetric supercapacitor device delivers excellent energy and power density of 24.30 Wh kg –1 and 500 W kg –1 , respectively. These results demonstrate and conclude that NCO/GQDs are exceptional and prospective candidates for developing next-generation high-performance and sustainable energy storage devices.

25 ENERGY STORAGE↗

Multilayer DNA Origami with Terminal Interfaces That Are Flat and Wide-Area

DNA origami is a popular nanofabrication strategy that employs self-assembly of a long single scaffold strand, typically less than 10 kilobases in length, with hundreds of shorter staple strands into a desired shape. In particular, origami arranged as a single-layer rectangle has proven popular as flat pegboards that can display functionalities at staple-strand breakpoints, off the sides of the constituent double helices, with a ~5.3 nm rhombic-lattice spacing. For applications that demand tighter spacing, functionalities can be displayed instead on the termini of helices of multilayer DNA origami. However, pegboards with the greatest addressable surface area are often found to be the most versatile. Given the practical limitations of the length of the scaffold that can be easily realized, designs that minimize the length of each helix would have advantages for maximizing the number of helices and therefore the number of addressable pixels on each terminal surface. Here we present an architecture for multilayer DNA origami displaying flush terminal interfaces from over 200 helices that each are only 5.3 turns in length. As a result, we characterize an example using cryo-EM imaging paired with single-particle analysis for further analysis of the global structure.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced Feedstock Characterization and Modeling to Facilitate Optimal Preprocessing and Deconstruction of Corn Stover (Final Report)

This project addresses the challenge of processing corn stover by fractionating this biomass feedstock to both streamline processing and generate new potential co-products. Additionally, the project developed new field-deployable analytical tools that can be coupled with empirical models that were used to predict feedstock properties and processing performance. The overall scope of this project was: (1) identify conditions for optimal corn stover fractionation using a two- stage physical fractionation, (2) assess how physical fractionation impacts properties, partitioning of biomass, and response to processing, (3) further adapt, develop, and validate several advanced characterization tools for assessing biomass properties that can be linked to processing behavior, and (4) develop and validate predictive models based on measurements that can be performed “in the field” or “at the biorefinery gate” to predict feedstock processing behavior (preprocessing and deconstruction). The first objective employed pre-separation processing (size reduction) which was next subjected to enhanced separations to yield fractions enriched or depleted in select compositional components or properties. For the second objective, fractions were screened for their response to post-separation processing (pretreatment and enzymatic hydrolysis). Detailed characterization profiles were developed and dynamic image analysis to assess distribution of particle size and morphology. For the final objective, we utilized these tools to develop empirical models to assess the relative abundance of tissue type in order to assess fractionation efficacy and to predict fraction performance during pretreatment and enzymatic hydrolysis.

09 BIOMASS FUELS↗

Multi-Angle Snowflake Camera, particle analysis

The c1 level data product for the Mutli-Angle Snowflake Camera contains snowflake fall speeds and particle size, among other analysis for images associated with each hydrometeor.

54 ENVIRONMENTAL SCIENCES↗

Multi-Angle Snowflake Camera, time bins

The c1 level data product for the Mutli-Angle Snowflake Camera contains snowflake fall speeds and particle size, among other analysis for images associated with each hydrometeor.

54 ENVIRONMENTAL SCIENCES↗

Discrete element modeling of switchgrass particles under compression and rotational shear

Switchgrass is a perennial herbaceous plant regarded as a biomass energy crop in the United States for its highadaptability and yield potential. Processing and handling of switchgrass particles are challenging due to the erratic mechanical and flow behavior originating from their intrinsic particulate properties. Here, we present a bonded-sphere discrete element model designed specifically for switchgrass particles. The model simultaneously captures three key particulate features, i.e., fibrous particle shapes, a wide range of particle sizes, and particle deformability. Realistic yet computationally efficient particle shape templates are created based on the image analysis data of switchgrass specimens. A fitting procedure is proposed to ensure both the particle width and length distributions are captured, a unique requirement for fibrous particles. Two full-scale numerical models, i.e., a uniaxial compression model and a Schulze ring shear model, are developed using information fromphysical experiments. The model is calibrated using experimental data of chopped-small switchgrass specimens, and then, is validated using data of chopped-large specimens in both compression and ring-shear tests. Numerical results show that the numerical models capture bulk densities accurately (with an error of 3%) while slightly underestimate the bulk friction angle. Furthermore, an extensive sensitivity analysis reveals that (1) switchgrass particles with rougher edges (due to different processing techniques) exhibit a higher shear strength and a lower flowability; (2) stiffer particles yield a lower bulk density (up to 21% lower) compared to more deformable particles, indicating particle deformability should be incorporated when modeling biomass flow in a preprocessing system.

09 BIOMASS FUELS↗

Characterization of Virgin, Re-used, and Oxygen-reduced Copper Powders processed by the Plasma Spheroidization Process

We report that fabrication of parts with high mechanical properties heavily depend on the quality of powder deployed in the fabrication process. Copper powder in three different powder types were spheroidized using radio-frequency inductively coupled plasma (ICP) spheroidization process (TekSphero-15 system). The characterized powders include virgin powder as purchased from the powder manufacturer, powder used in electron beam powder bed fusion (EB-PBF) process, and reconditioned powder, which was used powder that underwent an oxygen-reduction treatment. The goal of spheroidizing these powder types was to evaluate the change in powder morphology, the possibility of enhancing the powder properties back to their as-received conditions, and assess oxygen reduction of the powder lots given their initial oxygen contents. Also, to investigate the impact of re-spheroidization on powder properties, the second round of spheroidization was performed on the already used-spheroidized powder. The impact of powder type on powder sphericity and particle size distribution was evaluated using the image analysis of scanning electron microscope (SEM) micrographs and laser diffraction, respectively. The spheroidized powder showed higher sphericity and more uniform particle size distribution overall. Depending on the powder collection bin, second round of spheroidization affected the powder sphericity differently. The possibility of deploying the plasma spheroidization process as an alternative oxygen-reduction technique was also investigated through tracking the powders’ oxygen content using inert gas fusion method before and after the spheroidization. The plasma spheroidized powder showed less oxygen content than the hydrogen-treated powder. The second round of spheroidization caused no change in oxygen content. The correlation between oxygen-reduction and created cracks was discussed and compared between plasma spheroidization and hydrogen-treatment. The plasma spheroidization process created a powder with higher sphericity, uniform particle size, and less oxygen content.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AGR-1 UCO Kernel Phase Analysis Imaging Archive

UCO kernels in tri-structural isotropic (TRISO) particles consist of a heterogeneous mixture of uranium oxide and uranium carbide. During the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program, mean kernel composition was specified based on bulk measurements of uranium, oxygen, and carbon content, as well as the resulting O/U, C/U, and O+C/U ratios. Further development of quality control characterization methods has resulted in a method for more direct measurement of phase fractions on a per-kernel basis using optical microscopy of polished kernel cross sections. This report provides benchmark values for this analysis method when applied to kernels from the AGR-1 campaign and to the raw images used.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A low-latency graph computer to identify metastable particles at the Large Hadron Collider for real-time analysis of potential dark matter signatures

Abstract Image recognition is a pervasive task in many information-processing environments. We present a solution to a difficult pattern recognition problem that lies at the heart of experimental particle physics. Future experiments with very high-intensity beams will produce a spray of thousands of particles in each beam-target or beam-beam collision. Recognizing the trajectories of these particles as they traverse layers of electronic sensors is a massive image recognition task that has never been accomplished in real time. We present a real-time processing solution that is implemented in a commercial field-programmable gate array using high-level synthesis. It is an unsupervised learning algorithm that uses techniques of graph computing. A prime application is the low-latency analysis of dark-matter signatures involving metastable charged particles that manifest as disappearing tracks.

47 OTHER INSTRUMENTATION↗

3D analysis of TRISO fuel compacts via X-ray computed tomography

In this study, low-enriched uranium oxycarbide (LEUCO) and surrogate tristructural isotropic (TRISO)- coated-particle compacts with particle volumetric packing fractions of 25%, 40%, and 48% were imaged utilizing X-ray-computed tomography. Subsequent 3D image analysis identified and further quantified kernel size, sphericity, and observed porosity. In addition, the spatial distribution, coordination number, and kernel-nearest neighbors were analyzed and compared for the different packing fractions. Metrics such as observed porosity and sphericity enabled quantification and screening for abnormal kernels within TRISO compacts. Assessment of TRISO particle location confirmed and further quantified a non-uniform distribution of TRISO particles with the spatial distribution in the radial direction being roughly described as a dampened sinusoidal function. The amplitude and frequency of this non-uniform distribution increased with increasing packing fraction. Measured kernel-nearest neighbor distances indicated two regions along the radial surfaces of compacts where TRISO particles are more likely to be in intimate contact with one another. These regions were found: (1) at upper and lower faces of compacts (i.e., corners); (2) offset ~10% of a compact's length from the axial center near the exterior surface. Within these regions, small quantities of defective TRISO surrogate particles (48% packing fraction) and defective LEUCO TRISO particles (40% packing fraction) were found. No defective particles were found within 25% packing fraction LEUCO TRISO compacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Moving Dust Particles

A large depth-of-field Particle Image Velocimeter (PIV) has been developed at NASA GSFC to characterize dynamic dust environments on planetary surfaces. This instrument detects and senses lofted dust particles. We have been developing an autonomous image analysis algorithm architecture for the PIV instrument to greatly reduce the amount of data that it has to store and downlink. The algorithm analyzes PIV images and reduces the image information down to only the particle measurement data we are interested in receiving on the ground - typically reducing the amount of data to be handled by more than two orders of magnitude. We give a general description of PIV algorithms and describe only the algorithm for estimating the velocity of the traveling particles.

Bos, Brent J.↗