Search NASA⌕ Search

SEARCH · Search NASA

Results for “particle therapy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

72 records · Page 4

Bright Infrared‐to‐Ultraviolet/Visible Upconversion in Small Alkaline Earth‐Based Nanoparticles with Biocompatible CaF 2 Shells

Abstract Upconverting nanoparticles (UCNPs) are promising candidates for photon‐driven reactions, including light‐triggered drug delivery, photodynamic therapy, and photocatalysis. Herein, we investigate the NIR‐to‐UV/visible emission of sub‐15 nm alkaline‐earth rare‐earth fluoride UCNPs (M 1− x Ln x F 2+ x , MLnF) with a CaF 2 shell. We synthesize 8 alkaline‐earth host materials doped with Yb 3+ and Tm 3+ , with alkaline‐earth (M) spanning Ca, Sr, and Ba, MgSr, CaSr, CaBa, SrBa, and CaSrBa. We explore UCNP composition, size, and lanthanide doping‐dependent emission, focusing on upconversion quantum yield (UCQY) and UV emission. UCQY values of 2.46 % at 250 W cm −2 are achieved with 14.5 nm SrLuF@CaF 2 particles, with 7.3 % of total emission in the UV. In 10.9 nm SrYbF:1 %Tm 3+ @CaF 2 particles, UV emission increased to 9.9 % with UCQY at 1.14 %. We demonstrate dye degradation under NIR illumination using SrYbF:1 %Tm 3+ @CaF 2 , highlighting the efficiency of these UCNPs and their ability to trigger photoprocesses.

Fischer, Stefan↗

Bright Infrared‐to‐Ultraviolet/Visible Upconversion in Small Alkaline Earth‐Based Nanoparticles with Biocompatible CaF 2 Shells

Abstract Upconverting nanoparticles (UCNPs) are promising candidates for photon‐driven reactions, including light‐triggered drug delivery, photodynamic therapy, and photocatalysis. Herein, we investigate the NIR‐to‐UV/visible emission of sub‐15 nm alkaline‐earth rare‐earth fluoride UCNPs (M 1− x Ln x F 2+ x , MLnF) with a CaF 2 shell. We synthesize 8 alkaline‐earth host materials doped with Yb 3+ and Tm 3+ , with alkaline‐earth (M) spanning Ca, Sr, and Ba, MgSr, CaSr, CaBa, SrBa, and CaSrBa. We explore UCNP composition, size, and lanthanide doping‐dependent emission, focusing on upconversion quantum yield (UCQY) and UV emission. UCQY values of 2.46 % at 250 W cm −2 are achieved with 14.5 nm SrLuF@CaF 2 particles, with 7.3 % of total emission in the UV. In 10.9 nm SrYbF:1 %Tm 3+ @CaF 2 particles, UV emission increased to 9.9 % with UCQY at 1.14 %. We demonstrate dye degradation under NIR illumination using SrYbF:1 %Tm 3+ @CaF 2 , highlighting the efficiency of these UCNPs and their ability to trigger photoprocesses.

Fischer, Stefan↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Cutaneous and local radiation injuries

The threat of a large-scale radiological or nuclear (R/N) incident looms in the present-day climate, as noted most recently in an editorial in Scientific American (March 2021). These large-scale incidents are infrequent but affect large numbers of people. Smaller-scale R/N incidents occur more often, affecting smaller numbers of people. There is more awareness of acute radiation syndrome (ARS) in the medical community; however, ionising radiation-induced injuries to the skin are much less understood. Here, this article will provide an overview of radiation-induced injuries to the skin, deeper tissues, and organs. The history and nomenclature; types and causes of injuries; pathophysiology; evaluation and diagnosis; current medical management; and current research of the evaluation and management are presented. Cutaneous radiation injuries (CRI) or local radiation injuries (LRI) may lead to cutaneous radiation syndrome, a sub-syndrome of ARS. These injuries may occur from exposure to radioactive particles suspended in the environment (air, soil, water) after a nuclear detonation or an improvised nuclear detonation (IND), a nuclear power plant incident, or an encounter with a radioactive dispersal or exposure device. These incidents may also result in a radiation-combined injury; a chemical, thermal, or traumatic injury, with radiation exposure. Skin injuries from medical diagnostic and therapeutic imaging, medical misadministration of nuclear medicine or radiotherapy, occupational exposures (including research) to radioactive sources are more common but are not the focus of this manuscript. Diagnosis and evaluation of injuries are based on the scenario, clinical picture, and dosimetry, and may be assisted through advanced imaging techniques. Research-based multidisciplinary therapies, both in the laboratory and clinical trial environments, hold promise for future medical management. Great progress is being made in recognising the extent of injuries, understanding their pathophysiology, as well as diagnosis and management; however, research gaps still exist.

61 RADIATION PROTECTION AND DOSIMETRY↗

Codelivery of Paclitaxel and Parthenolide in Discoidal Bicelles for a Synergistic Anticancer Effect: Structure Matters

Nanotechnology has long been used to improve the tumor targeting of chemotherapeutics. The structure of these nanocarriers greatly affects their efficacy and toxicity. Herein, structurally stable nanodiscoidal phospholipid bicelles, which are capable of encapsulating anticancer drugs, paclitaxel (PTX) and parthenolide (PTL), are designed. This nanodiscoidal bicelle structure is shown previously to exhibit longer blood circulation, deeper tumor penetration, and increased tumor cell uptake compared with spherical particles of similar compositions. Structural characterization and loading capacity of the PTX‐ and PTL‐ loaded nanodiscs are conducted along with an investigation into the cytotoxicity of the bicelles based on the drug‐to‐lipid ratios of both drugs loaded separately and in combination. A significant synergistic effect between both loaded drugs is also observed in A549 lung cancer and drug‐resistant MDA‐MB‐231 cell lines. An in vivo study using mice bearing subcutaneous A549 tumors shows a long circulation time of the intravenously injected DiR‐loaded bicelles and significant antitumor efficacy of the PTX‐ and PTL‐loaded bicelles. This efficacious self‐assembled nanoparticle system displays great potential as a nanoplatform to codeliver multiple therapeutics or diagnostics for improving cancer therapy.

Rad, Armin Tahmasbi↗

Compact, Achromatic Non-scaling FFAG Accelerator for HEP, Commercial and Medical Applications (CRADA FRA-2008-0005 Final Report)

Proton and light-ion accelerators have many research and medical applications, but the current state of technology in accelerators severely limits their widespread use: (1) synchrotrons have an intrinsic low duty cycle and become quite large for light ions; and (2) cyclotrons do not have energy variability and require complex superconducting magnets for high energy. A new concept in non-scaling Fixed-Field Alternating-Gradient (FFAGs) has been invented that incorporates both the energy variability of the synchrotron and the high duty cycle of the cyclotron. The concept uses normal-conducting, combined-function magnets that apply only constant (dipole) and linear-gradient (quadrupole) fields to stabilize the accelerator. This project will develop an optimized design for a new non-scaling and cost-effective innovation in FFAG accelerators. The accelerator design will have optics that can stably accelerate protons to 250 MeV (or higher) and carbon ions to =200 MeV, an energy considered ideal for radiation therapy. Phase I will optimize, fully simulate, and demonstrate the feasibility of this accelerator. Commercial Applications and other Benefits as described by the awardee: The fixed-field acceleration concept should eliminate some of the most pronounced technical difficulties, expense, maintenance, and required expertise faced in conventional proton and light-ion accelerators. In addition to the application for high energy physics, these accelerators should have application in cancer treatment, radiopharmaceuticals, and medical isotope production, and materials science.

43 PARTICLE ACCELERATORS↗

Novel methods for TH-229 production through fast neutron irradiation of TH-23F0 and charged particle irradiation of Th-230 and Th-232. Final Report DE-SC0020140

The activities and results of research related to accelerator production of Pa and Th isotopes via bombardment of 230 Th and 232 Th targets are described herein. This research was supported through DOE grant DE-SC0020140 and was conducted in collaboration with Oak Ridge National Laboratory and Lawrence Berkeley National Laboratory. Cross section measurements, transport model and nuclear physics model calculations are presented. Highlights include the first ever measurements of 229 Pa, two publications, and graduation of a PhD student.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Glycosylation of SARS-CoV-2: structural and functional insights

The COVID-19 pandemic is caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Similar to other coronaviruses, its particles are composed of four structural proteins: spike (S), envelope (E), membrane (M), and nucleocapsid (N) proteins. S, E, and M proteins are glycosylated, and the N protein is phosphorylated. The S protein is involved in the interaction with the host receptor human angiotensin-converting enzyme 2 (hACE2), which is also heavily glycosylated. Recent studies have revealed several other potential host receptors or factors that can increase or modulate the SARS-CoV-2 infection. Interestingly, most of these molecules bear carbohydrate residues. While glycans acquired by the viruses through the hijacking of the host machinery help the viruses in their infectivity, they also play roles in immune evasion or modulation. Here, glycans play complex roles in viral pathobiology, both on their own and in association with carrier biomolecules, such as proteins or glycosaminoglycans (GAGs). Understanding these roles in detail can help in developing suitable strategies for prevention and therapy of COVID-19. In this review, we sought to emphasize the interplay of SARS-CoV-2 glycosylated proteins and their host receptors in viral attachment, entry, replication, and infection. Moreover, the implications for future therapeutic interventions targeting these glycosylated biomolecules are also discussed in detail.

59 BASIC BIOLOGICAL SCIENCES↗

SRF Resonators for a bi-directional Energy Ramping Upgrade of the Isotope Production Facility Beamline at LANL

The LANL Isotope Production Facility (IPF) is one of the two high-current proton linear accelerators operated under the auspices of the DOE Office of Nuclear Physics Isotope Development and Production for Research Applications Program. The IPF beamline operates with a fixed 100-MeV energy proton beam, diverted from the LANSCE accelerator and guided towards the isotope production target station. The fixed beam energy limits the number of isotopes that can be produced at IPF, and adversely affects the purity of isotopes produced at non-optimal energies. In particular, the IPF program is receiving increasing numbers of requests for high purity isotopes such as Np-236 (national security applications) and Re-186 (medical therapy). These are typically produced via (p,n) and (p,2n) nuclear reactions, requiring very tight control of the incident energies on the production targets to ensure an end product with a high radionuclidic purity. It is well known that this level of energy control cannot be achieved when a 100 MeV beam of mono-energetic protons is degraded to the required energies, typically below 30 MeV, as too much energy spread is acquired. Operating the IPF beamline at lower, mono-energetic beam energies such as at 40 MeV will allow the required tight energy control in target assemblies to ensure a high purity product. In addition, NP has requested a LANL/BNL/ORNL collaboration focus on establishing a national large-scale production capability for the therapy isotope Ac-225. Recent nuclear cross section measurements done at LANL show that due to a steep rise in production cross section towards higher proton energies (See Figure 2), proton beams at energies substantially greater than 100 MeV will be highly beneficial for Ac-225 production [AC255]. Such higher-energy beams cannot be delivered to IPF at present. Lower-energy beams (70 MeV and 40 MeV) can be delivered but only in sole-use mode; all other LANSCE users must be offline during 70 MeV or 40 MeV operation.

07 ISOTOPE AND RADIATION SOURCES↗

Discovering novel therapeutic V H Hs for emerging viruses: perspectives from VEEV selection strategies

Introduction: Evolution or emergence of a new viral variant is a significant public health concern. Alphaviruses, such as Venezuelan equine encephalitis virus (VEEV), are mosquito-borne viruses which are becoming more prevalent due to expansion of vector habitats. Despite this, there are currently no antiviral therapies or FDA-approved vaccines available to treat or prevent VEEV infection. The increased prevalence of such viruses provides opportunities for novel variants to evolve. Key therapeutic molecules that could be developed against viral pathogens are recombinant antibodies or antibody fragments, such as the variable heavy domain of heavy chain antibodies (V H Hs). Methods: In vitro selections offer a promising pathway for identification of therapeutic antibodies, here we explored isolation of V H Hs using phage and yeast display methodology with three antigen formats 1) recombinant E2, 2) linear peptides of E2, selected based on molecular dynamics analysis, and 3) UV inactivated virus. Results: Here we report four novel “human” V H Hs which bind to the VEEV E2 protein selected using different strategies that include both computational and biochemical design of suitable antigens and whole virus selections. These V H Hs have distinct complementarity-determining regions (CDRs). Multiple VHHs bind to the VEEV viral particles in ELISAs, and we report the peptide epitope recognized by these V H Hs. Discussion: Though non-neutralizing, these V H Hs bind to and sequester VEEV viral particles preventing infection, demonstrating the potential of these V H Hs to perform viral “sponging” which represents a novel therapeutic approach. The selection strategies we report may have applications to further antibody developments against other viruses.

59 BASIC BIOLOGICAL SCIENCES↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Rapid recovery of At-211 by extraction chromatography

The near quantitative separation, purification, and recovery of 211 At has been demonstrated through an extraction chromatography process which utilizes porous beads impregnated with 3-octanone, resulting in an elution yield of 92–95%. Moreover, the rapid nature of this process, <20 min, was achieved after dissolution of a Bi metal target in HNO 3 following retrieval from the beamline after α-particle bombardment. The solution was directly loaded onto the column with no volume or acidity adjustment. The column was washed with HNO 3 and H 2 O, and 211 At was eluted with ethanol, collecting roughly 87–93% in 1 mL. This process of recovering high purity 211 At, in near quantitative yields, represents a significant advance in At separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of resistive magnetic field generation by intense proton beams in dense plasmas

Current and future applications of intense proton sources abound, including radiography, cancer therapy, warm dense matter generation, and inertial confinement fusion. With increasingly efficient acceleration and focusing mechanisms, proton current densities may soon approach and exceed 10 10 A/cm 2 , e.g., via intense laser drivers. Simulations have previously shown that in this current density regime, beam-induced field generation plays a significant role in beam transport through dense plasmas. Here, we present a theoretical model for the generation of resistive magnetic fields by intense proton beam transport through solid density plasmas. The theoretical evolution of the magnetic field profile is calculated using an analytic model for aluminum resistivity, heat capacity, and stopping power, applicable from cold matter to hot plasma. The effects of various beam and material parameters on the field are investigated and explained for both monoenergetic and Maxwellian proton beams. For a proton beam with Maxwellian temperature 5 MeV and total energy 10 J, the model calculates resistive magnetic fields up to 150 T in aluminum. In conclusion, the calculated field profiles from several beam cases are compared with 2D hybrid particle-in-cell simulations, with good agreement found in magnitude and time scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of Magnetic Anisotropy on the Hyperthermia Efficiency in Spherical Fe3−xCoxO4 (x = 0–1) Nanoparticles

The use of magnetic nanoparticles in the treatment of cancer using alternating current hyperthermia therapy has shown the potential to replace or supplement conventional cancer treatments, radiotherapy and chemotherapy, which have severe side effects. Though the nearly spherical sub-10 nm iron oxide nanoparticles have their approval from the US Food and Drug Administration, their low heating efficiency and removal from the body after hyperthermia treatment raises serious concerns. The majority of magnetic hyperthermia research is working to create nanomaterials with improved heating efficiency and long blood circulation time. Here, we have demonstrated a simple strategy to enhance the heating efficiency of sub-10 nm Fe3O4 nanoparticles through the replacement of Fe+2 ions with Co+2 ions. Magnetic and hyperthermia experiments on the 7 nm Fe3−xCoxO4 (x = 0–1) nanoparticles showed that the blocking temperature, the coercivity at 10 K, and the specific absorption rate followed a similar trend with a maximum at x = 0.75, which is in corroboration with the theoretical prediction. Our study revealed that the heating efficiency of the Fe3−xCoxO4 (x = 0–1) nanoparticles varies not just with the size and saturation magnetization but also with the magnetocrystalline anisotropy of the particles.

36 MATERIALS SCIENCE↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

High deuteron and neutron yields from the interaction of a petawatt laser with a cryogenic deuterium jet

A compact high-flux, short-pulse neutron source would have applications from nuclear astrophysics to cancer therapy. Laser-driven neutron sources can achieve fluxes much higher than spallation and reactor neutron sources by reducing the volume and time in which the neutron-producing reactions occur by orders of magnitude. We report progress towards an efficient laser-driven neutron source in experiments with a cryogenic deuterium jet on the Texas Petawatt laser. Neutrons were produced both by laser-accelerated multi-MeV deuterons colliding with Be and mixed metallic catchers and by d (d,n) 3 He fusion reactions within the jet. We observed deuteron yields of 10 13 /shot in quasi-Maxwellian distributions carrying ~8-10% of the input laser energy. We obtained neutron yields greater than 10 10 /shot and found indications of a deuteron-deuteron fusion neutron source with high peak flux (>10 22 cm -2 s -1 ). The estimated fusion neutron yield in our experiment is one order of magnitude higher than any previous laser-induced dd fusion reaction. Though many technical challenges will have to be overcome to convert this proof-of-principle experiment into a consistent ultra-high flux neutron source, the neutron fluxes achieved here suggest laser-driven neutron sources can support laboratory study of the rapid neutron-capture process, which is otherwise thought to occur only in astrophysical sites such as core-collapse supernova, and binary neutron star mergers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmarking Monte Carlo codes for the modelling of low-energy neutron production target reactions

The increasing adoption of accelerator-based neutron sources (ABNS) for applications including neutron capture therapy (NCT) research has highlighted the need for accurate simulation tools. Precise modelling of the neutron production target is crucial to ensure that simulated predictions of neutron beam characteristics used for subsequent beam shaping assembly design are reliable. This work presents a comprehensive benchmarking of four widely-used Monte Carlo codes - Geant4, PHITS, FLUKA (CERN), and MCNP - for modelling low-energy neutron production target reactions. Using their recommended physics models and cross-section libraries, we evaluate each code’s performance in simulating four beam-target reactions: 7 Li(p,n) 7 Be, 9 Be(p,n) 9 B, 9 Be(d,n) 10 B, and C(d,n)N. Predictions of neutron yield, angular distributions, and energy spectra are compared against available thick target experimental data. Results show varying levels of agreement between the codes depending on the reaction type, energy range, and beam characteristics. Geant4, MCNP and PHITS are the overall best performing codes for the simulation of total neutron yield and yield in the forward direction across most reactions. Across energies where experimental benchmarks exist, inter-code discrepancies in total and forward-directed yield are typically 10 to 30%, with larger deviations at near-threshold incident ion energies. PHITS provides the best overall reproduction of experimental spectra, particularly for the 9 Be(p,n) 9 B reaction. Additionally, PHITS demonstrates superior computational performance for most reactions. These findings provide valuable guidance for ABNS design, highlighting the strengths and limitations of each code for the simulation of low-energy neutron production reactions.

43 PARTICLE ACCELERATORS↗