Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Purity and Cleanness of Aeorgel as a Cosmic Dust Capture Medium

The capability for capturing micrometeoroids intact through laboratory simulations [Tsou 1988] and in space [Tsou 1993] in passive underdense silica aerogel offers a valuable tool for cosmic dust research. The integrity of the sample handling medium can substantially modify the integrity of the sample. Intact capture is a violent hypervelocity event: the integrity of the capturing medium can cause even greater modification of the sample.

micrometeoroids cosmic dust silica aerogel↗

Evaluation of common trap types for capturing wild pigs

Abstract Wild pigs ( Sus scrofa ) are one of the most ecologically harmful invasive vertebrates globally. Due to their negative impacts, wild pig populations are managed via trapping, yet studies investigating various trap designs have been limited in duration, location, and number of trappers. Using data from professional trappers across the southeastern U.S., we evaluated the performance of 3 wild pig trap types (corral, drop, passive net), and the effect of forage season (barren, green‐up, masting) on trapping success. Specifically, we compared trap effectiveness (estimated proportion of targeted wild pigs caught per capture event), trap night effort (number of days to first catch), and the amount of bait and time used per individual take over the lifetime of each trap location across the 3 trap types and forage seasons. Across >850 capture events by 31 trappers, all 3 trap types evaluated were effective at capturing entire social groups of wild pigs. Few differences were observed among trap types, although drop traps in masting season captured a greater estimated proportion of wild pigs per capture event compared to other trap type‐season combinations. Our data also revealed that passive net traps required slightly more bait/wild pig captured than drop traps but there was no difference in the time/wild pig captured among traps. Our findings demonstrate that when operated by wildlife professionals, multiple designs of wild pig traps can be effective at removing targeted groups of wild pigs. Further, our results offer insights regarding the performance of wild pig trap types across seasons that can be used to inform wild pig trapping programs.

Taylor, Charles R. [Warnell School of Forestry and↗

Metal–Organic Framework–Polyacrylonitrile Composite Beads for Xenon Capture

Mechanically robust forms of HKUST-1 metal-organic frameworks (MOFs) were fabricated by embedding the MOF in a passive polyacrylonitrile (PAN) matrix at different MOF loadings of 10–90 mass%. Here, the PAN is highly porous and acts as a scaffold that holds the active MOF adsorbent in place for Xe capture. Data presented herein show that the PAN matrix does not notably interfere with the Xe capture process where the Xe capacities scale somewhat linearly with the increase in MOF loading in the composites. Radiation testing of the composites under a gamma flux revealed that they are highly tolerant to these types of radiation fields.

36 MATERIALS SCIENCE↗

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗

Energy-Efficient Direct Air Capture System for High Purity CO 2 Separation

The primary objective of this project is to demonstrate the University of Cincinnati’s direct air capture (DAC) sorbent technology in a monolithic structure installed in a passive air contactor (PAC). The modified amine-based sorbent technology provides reduced heat of desorption and resistance to thermal and oxidative degradations for robust and long-term performances and cost effective sorbent management. During the project period, additional amine modifications were developed and a U.S./PCT patent application was filed.

42 ENGINEERING↗

Detection Thresholds of Falling Snow From Satellite-Borne Active and Passive Sensors

There is an increased interest in detecting and estimating the amount of falling snow reaching the Earths surface in order to fully capture the global atmospheric water cycle. An initial step toward global spaceborne falling snow algorithms for current and future missions includes determining the thresholds of detection for various active and passive sensor channel configurations and falling snow events over land surfaces and lakes. In this paper, cloud resolving model simulations of lake effect and synoptic snow events were used to determine the minimum amount of snow (threshold) that could be detected by the following instruments: the W-band radar of CloudSat, Global Precipitation Measurement (GPM) Dual-Frequency Precipitation Radar (DPR)Ku- and Ka-bands, and the GPM Microwave Imager. Eleven different nonspherical snowflake shapes were used in the analysis. Notable results include the following: 1) The W-band radar has detection thresholds more than an order of magnitude lower than the future GPM radars; 2) the cloud structure macrophysics influences the thresholds of detection for passive channels (e.g., snow events with larger ice water paths and thicker clouds are easier to detect); 3) the snowflake microphysics (mainly shape and density)plays a large role in the detection threshold for active and passive instruments; 4) with reasonable assumptions, the passive 166-GHz channel has detection threshold values comparable to those of the GPM DPR Ku- and Ka-band radars with approximately 0.05 g *m(exp -3) detected at the surface, or an approximately 0.5-1.0-mm * h(exp -1) melted snow rate. This paper provides information on the light snowfall events missed by the sensors and not captured in global estimates.

remote sensing↗

Video Guidance Sensor: Optical Performance Predictions and Results from STS-95 Experiment

The Video Guidance Sensor is a key component of NASA's Automated Rendezvous & Capture Program. The Video Guidance Sensor Uses laser illumination of a passive target in the field of view of an on-board camera and signal processor to determine the relative position and attitude between the target and sensor. The Video Guidance Sensor flew on space shuttle mission STS-95 in November of 1998 and was a marked success. Comparisons of experimental results from that mission and theoretical models predicting the optical performance will be discussed.

Jackson, John L.↗

The Video Guidance Sensor- A Flight Proven Technology

The Video Guidance Sensor (VGS) flew on Shuttle mission STS-95 in October of 1998 to test the VGS functional characteristics on orbit. This was the second flight of the VGS, and during these two flights, both long range and short range data were gathered under a variety of lighting conditions, orbital exposure times, and temperatures. The flight experiment sensor was designed to operate from 1.5 meter range out to 110 meter range, with a field-of-view of 16 X 21 degrees. The VGS tracked its target at a 5 Hz rate and returned 6-degree-of-freedom information on the target's position and attitude relative to the sensor. The VGS was mounted in the Shuttle cargo bay, and its target was mounted on the Spartan spacecraft being carried on this mission. The VGS is a sensor designed to allow an automated vehicle to dock with a spacecraft equipped with a passive target. The VGS is a part of an Automated Rendezvous and Capture (AR&C) system being developed and tested by NASA. The orbital testing included operations with the target on the Shuttle's Remote Manipulator System (RMS) near the start of each flight of the VGS, long-range data (on the STS-95 flight) during the Shuttle rendezvous with the Spartan two days later, and some more RMS operations later in the mission. The data returned from the orbital testing included VGS diagnostics, acquisition, and tracking data, RMS positions, hand-held laser range data, tapes of the data from the VGS video camera, and orbital positioning data from the Spartan and the Shuttle to allow correlation of the VGS data with orbital best-estimate-of-truth data. The Video Guidance Sensor performed well in all phases of the testing, and the VGS is being incorporated into the ground testing of a complete automated rendezvous and docking system. Work on the development of the next generation VGS is continuing.

Howard, Richard T.↗

Heating and Sampling Efficiency Evaluation for the Nephele Venus Cloud Sampling Mission Concept

Nephele [1] is a descent probe concept with a unique combination of entry (3D-CC+HEEET), sampling (flow-through passive impactors), and optics (laser-induced breakdown spectroscopy, or LIBS, and surface-enhanced Raman spectroscopy, or SERS), technologies with two key innovations (Figure 1). The first is the integration of the aerosol sampling inlet into the aeroshell body, allowing the possibility of sampling during passive descent without separation. The second is the use of the aerosol capture surface as an optical analysis substrate, allowing fast-cadence aerosol analysis via a dual optical spectrometer instead of mass spectrometry. Although this concept shares some features with other efforts such as Cupid’s Arrow [1] (single-body sample capture system), DAVINCI [2] and Venera-D [3] (use of an optical spectrometer), Nephele is unique in its physical integration of the sonde body, aerosol and gas sampler, and analysis instrumentation. This innovation is designed to eliminate the need for a controlled descent to achieve a detailed atmospheric aerosol transect, which offers in situ planetary science in a small spacecraft envelope. Aeroshell designs with inlets for free-falling sondes are well-understood, though not yet assessed for aerosol capture efficiency. A HEEET aeroshell with a specialized nose inlet material comprised of Carbon-Carbon is proposed for this mission concept.

Venus↗

Heating and Sampling Efficiency Evaluation for the Nephele Venus Cloud Sampling Mission Concept

Nephele is a descent probe concept with a unique combination of entry (3D-CC+HEEET), sampling (flow-through passive impactors), and optics (laser-induced breakdown spectroscopy, or LIBS, and surface-enhanced Raman spectroscopy, or SERS), technologies with two key innovations. The first is the integration of the aerosol sampling inlet into the aeroshell body, allowing the possibility of sampling during passive descent without separation. The second is the use of the aerosol capture surface as an optical analysis substrate, allowing fast-cadence aerosol analysis via a dual optical spectrometer instead of mass spectrometry. Although this concept shares some features with other efforts such as Cupid’s Arrow (single-body sample capture system), DAVINCI and Venera-D (use of an optical spectrometer), Nephele is unique in its physical integration of the sonde body, aerosol and gas sampler, and analysis instrumentation. This innovation is designed to eliminate the need for a controlled descent to achieve a detailed atmospheric aerosol transect, which offers in situ planetary science in a small spacecraft envelope. Aeroshell designs with inlets for free-falling sondes are well-understood, though not yet assessed for aerosol capture efficiency. A HEEET aeroshell with a specialized nose inlet material comprised of Carbon-Carbon is proposed for this mission concept.

Venus↗

Fluid Lensing and Applications to Remote Sensing of Aquatic Environments

The use of fluid lensing technology on UAVs is presented as a novel means for 3D imaging of aquatic ecosystems from above the water's surface at the centimeter scale. Preliminary results are presented from airborne fluid lensing campaigns conducted over the coral reefs of Ofu Island, American Samoa (2013) and the stromatolite reefs of Shark Bay, Western Australia (2014), covering a combined area of 15km2. These reef ecosystems were revealed with centimetre-scale 2D resolution, and an accompanying 3D bathymetry model was derived using fluid lensing, Structure from Motion and UAV position data. Data products were validated from in-situ survey methods including underwater calibration targets, depth measurements and millimetre-scale high-dynamic range gigapixel photogrammetry. Fluid lensing is an experimental technology that uses water transmitting wavelengths to passively image underwater objects at high-resolution by exploiting time-varying optical lensing events caused by surface waves. Fluid lensing data are captured from low-altitude, cost-effective electric UAVs to achieve multispectral imagery and bathymetry models at the centimetre scale over regional areas. As a passive system, fluid lensing is presently limited by signal-to-noise ratio and water column inherent optical properties to approximately 10 m depth over visible wavelengths in clear waters. The datasets derived from fluid lensing present the first centimetre-scale images of a reef acquired from above the ocean surface, without wave distortion. The 3D multispectral data distinguish coral, fish and invertebrates in American Samoa, and reveal previously undocumented, morphologically distinct, stromatolite structures in Shark Bay. These findings suggest fluid lensing and multirotor electric drones represent a promising advance in the remote sensing of aquatic environments at the centimetre scale, or 'reef scale' relevant to the conservation of reef ecosystems. Pending further development and validation of fluid lensing methods, these technologies present a solution for large-scale 3D surveys of shallow aquatic habitats with centimetre-scale spatial resolution and hourly temporal sampling.

Aquatic↗

Cloud Macrophysical Changes Observed by MODIS, CALIPSO, and CloudSat for the 11-year Period

Using the Moderate Resolution Imaging Spectroradiometer (MODIS), Cloud–Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO), and CloudSatsatellitemeasurements, cloud macrophysicalchanges are examined from 2007 to 2017(Ham et al., 2021). Particularly, we compare cloud changes derived from MODIS passive sensor and CALIPSO-CloudSat (CALCS) combined active sensor measurements. Both MODIS and CALCS well capture general features of the cloud changes related to El Niño–Southern Oscillation (ENSO) events. However, because of better detections of thin cirrus clouds, CALCS cloud volume anomalies are better correlated with relative humidity anomalies, compared to MODIS. In addition, MODIS observations show a stronger anticorrelation between low and mid/high cloud volume anomalies, compared to CALCS, mainly due to limitations in detecting overlapping clouds by MODIS passive sensor.In addition, the geometrical thickness of MODIS mid/high clouds is thinner than that from CALCS, less affecting cloud amounts at 0-3 km altitude.

Cloud↗

Molecular basis of hemoglobin binding and heme removal in Corynebacterium diphtheriae

To successfully mount infections, nearly all bacterial pathogens must acquire iron, a key metal cofactor that primarily resides within human hemoglobin. Corynebacterium diphtheriae causes the life-threatening respiratory disease diphtheria and captures hemoglobin for iron scavenging using the surface-displayed receptor HbpA. Here, we show using X-ray crystallography, NMR, and in situ binding measurements that C. diphtheriae selectively captures iron-loaded hemoglobin by partially ensconcing the heme molecules of its α subunits. Quantitative growth and heme release measurements are compatible with C. diphtheriae acquiring heme passively released from hemoglobin’s β subunits. We propose a model in which HbpA and heme-binding receptors collectively function on the C. diphtheriae surface to capture hemoglobin and its spontaneously released heme. Acquisition mechanisms that exploit the propensity of hemoglobin’s β subunit to release heme likely represent a common strategy used by bacterial pathogens to obtain iron during infections.

NMR↗

Coding Structures for Seated Row Simulation of an Active Controlled Vibration Isolation and Stabilization System for Astronaut’s Exercise Platform

Simulation for seated aerobic row exercise was a continued task to assist NASA in analyzing a one-dimensional vibration isolation and stabilization system for astronaut’s exercise platform. Feedback delay and signal noise were added to the simulation model. Simulation runs for this study were conducted in two software simulation tools, Trick and MBDyn, software simulation environments developed at the NASA Johnson Space Center. The exciter force in the simulation was calculated from motion capture of an exerciser during a seated aerobic row exercise. The simulation runs include passive control, active control using a Proportional, Integral, Derivative (PID) controller, and active control using a Piecewise Linear Integral Derivative (PWLID) controller. Output parameters include displacements of the exercise platform, the exerciser, and the counterweight; transmitted force to the wall of spacecraft; and actuator force to the platform. The simulation results showed excellent force reduction in the active controlled system compared to the passive controlled system, which resulted in less force reduction.

Simulation↗

Accuracy of Center of Pressure Determination via Motion Capture

BACKGROUND: This study was conducted to support the stability assessment for tasks in lunar gravity and exercises on a Vibration Isolation and Stabilization (VIS) system in microgravity based on the dynamic feasibility criterion of whether the calculated position of the center of pressure (COP) falls within the base of support (BOS) which outlines the subject’s feet. Motion capture data combined with biomechanical modeling and simulation allows the forces and moments between the human and the VIS platform to be computed and the position of the COP as well as the location and shape of the BOS to be determined. The goal of this study was to assess the accuracy of the COP trajectory calculated using motion capture-based data. METHODS AND RESULTS: To obtain the dynamic quantities from which COP is calculated, motion capture data is first collected in the 1g lab environment by recording the trajectories of passive retroreflective markers placed on a subject during exercise or performance of a given task. The OpenSim [1] inverse kinematics (IK) tool is used to fit a scaled subject model to recorded marker trajectories while minimizing marker error to obtain joint angles. Then, a custom OpenSim plugin [2] is used to determine the subject’s time-varying moment of inertia and its time derivative, center of mass (CM) position, velocity, and acceleration, as well as the angular momentum and its time derivative relative to the subject’s CM. Some of these quantities are not needed for modeling tasks performed on a stationary lunar surface but, due to the moving exercise platform, are needed to model VIS response to the subject’s motion. Hand positions, used in calculating a cable force if present, are recorded as well. These quantities are used to calculate the total force (F ⃗^((plate) )) and moment (M ⃗^((plate) )) exerted by the lunar surface or the VIS plate on the subject’s shoe soles. COP is then calculated from the following equations: r_x^((cop) )= M_z^((plate) )/F_y^((plate) ) and r_z^((cop) )= 〖-M〗_x^((plate) )/F_y^((plate) ), where the y axis is normal to the surface. COP accuracy for feasibility assessments is then determined by whether it falls within the BOS, which is also computed by the plugin. To study the accuracy of COP calculated from motion capture, we first investigated whether COP remained within the BOS, as it must, for exercises performed in the 1g lab environment. Standard exercises such as back squat and deadlift were analyzed, as well as more explosive exercises including hang clean and press. Cases in which the COP exited the BOS indicated that COP accuracy required further investigation. In this study, an exercise device with cables was used, so cable force modeling accuracy should also be considered. In a separate study, we collected motion capture and force plate data for twenty-seven motions not involving an exercise device. About a third were genuine countermeasures exercises (e.g., hang clean and press), some were relevant for lunar tasks (e.g., object pick up), and the rest were of a “unit test” nature (e.g., swaying back and forth or side to side). Motion capture-based COP positions were compared with force plate measured COP. We found that while force plate measured COP remained within the BOS, motion capture-based COP was observed to briefly exit the BOS on occasion. Techniques to mitigate IK artifacts and filtering of calculated data could be used to improve the agreement of calculated and measured results, resolving excursions from the BOS within this dataset. The mean error between calculated and measured COP was found to be less than 6 mm. Additionally, we derived and investigated equations for the COP in terms of the cable force, cable location, as well as the human CM position, acceleration, and angular momentum with respect to the CM, and analyzed them for sensitivity to errors in individual quantities. Several were found, but the most significant one was that when the vertical force on the feet approaches zero, indicating a near-detachment or ‘jump off’ condition, errors are amplified. This is consistent with the observation that in the absence of pressure, the concept of the center of pressure would become meaningless.

C A Bell↗

FEOTS v0.0.0: a new offline code for the fast equilibration of tracers in the ocean

Abstract. In this paper we introduce a new software framework for the offline calculation of tracer transport in the ocean. The Fast Equilibration of Ocean Tracers Software (FEOTS) is an end-to-end set of tools to efficiently calculate tracer distributions on a global or regional sub-domain using transport operators diagnosed from a comprehensive ocean model. To the best of our knowledge, this is the first application of a transport matrix model to an eddying ocean state. While a Newton–Krylov-based equilibration capability is still under development and not presented here, we demonstrate in this paper the transient modeling capabilities of FEOTS in an application focused on the Argentine Basin, where intense eddy activity and the Zapiola Anticyclone lead to strong mixing of water masses. The demonstration illustrates progress in developing offline passive tracer simulation capabilities, while highlighting the challenges of the impulse response functions approach in capturing tracer transports by a non-linear advection scheme. Our future work will focus on improving the computational efficiency of the code to reduce time-to-solution, using different basis functions to better represent non-linear advection operators, applying FEOTS to a parent model with unstructured grids (Ocean Model for Prediction Across Scales, MPAS-Ocean), and fully implementing a Newton–Krylov steady-state solver.

54 ENVIRONMENTAL SCIENCES↗

A Numerical and Experimental Investigation of Flow Separation Control over a Wall-Mounted Hump Model

Numerical simulations and wind tunnel experiments were performed to investigate flow separation and its control over a wall-mounted hump model. Three-dimensional, unsteady fluid dynamic simulations were used to capture the relevant flow physics of unsteady flow separation and its control via active and passive flow control methods. Surface pressure measurements and surface oilflow visualization were obtained in the experiments. Current measurements documented a considerably thinner incoming boundary layer, but similar pressure distribution, compared to the reference data reported in the CFD (Computational Fluid Dynamics) Validation (CFDVAL 2004) Experiments. Consistent with the data available in the literature, numerical simulations predicted a longer separation bubble, which manifested itself as a shift in the pressure distributions. Streamwise vortices generated by passive vortex generators increased the suction pressure and provided substantial pressure recovery. Numerical simulations of vortex generators qualitatively predicted the effects of control, and revealed patterns of attached/separated flow regions. On the other hand, active flow control using steady discrete jets reduced, but was not able to eliminate, flow separation for the tested configuration. Although the major disagreement between the numerical and experimental results was in the pressure recovery region due to the inaccurate prediction of separation bubbles, the relative pressure recoveries from the baselines were comparable. Surface oilflow visualization and simulated surface streamlines were qualitatively in good agreement revealing the key flow features.

Koklu, Mehti↗