Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance bound”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

B-Trees and Cache-Oblivious B-Trees with Different-Sized Atomic Keys

Most B-tree articles assume that all $\textit{N}$ keys have the same size $\textit{K}$, that $\textit{f = B/K}$ keys fit in a disk block, and therefore that the search cost is $O(\text{log}_{f+1}N) $ block transfers. When keys have variable size, B-tree operations have no nontrivial performance guarantees, however. This article provides B-tree-like performance guarantees on dictionaries that contain keys of different sizes in a model in which keys must be stored and compared as opaque objects. The resulting atomic-key dictionaries exhibit performance bounds in terms of the average key size and match the bounds when all keys are the same size. Atomic-key dictionaries can be built with minimal modification to the B-tree structure, simply by choosing the pivot keys properly. Further, this article describes both static and dynamic atomic-key dictionaries. In the static case, if there are $\textit{N}$ keys with average size $\textit{K}$, the search cost is $O(\lceil K/B\rceil \text{log}_{1 + \lceil K/B\rceil} N)$ expected transfers. It is not possible to transform these expected bounds into worst-case bounds. The cost to build the tree is $\textit{O(NK)}$ operations and $\textit{O(NK/B)}$ transfers if all keys are presented in sorted order. If not, the cost is the sorting cost. For the dynamic dictionaries, the amortized cost to insert a key $\textit{κ}$ of arbitrary length at an arbitrary rank is dominated by the cost to search for $\textit{κ}$. Specifically, the amortized cost to insert a key $\textit{κ}$ of arbitrary length and random rank is $O(\lceil K/B\rceil log_{1+ \lceil B/K\rceil } N + |κ|/B)$ transfers. A dynamic-programming algorithm is shown for constructing a search tree with minimal expected cost. This article also gives a cache-oblivious static atomic-key B-tree, which achieves the same asymptotic performance as the static B-tree dictionary, mentioned previously. A cache-oblivious data structure or algorithm is not parameterized by the block size $\textit{B}$ or memory size $\textit{M}$ in the memory hierarchy; rather, it is universal, working simultaneously for all possible values of $\textit{B}$ or $\textit{M}$. On a machine with block size $\textit{B}$, if there are $\textit{N}$ keys with average size $\textit{K}$, search operations costs $O(\lceil K/B \rceil log_{1+ \lceil B/K \rceil} N)$ block transfers in expectation. This cache-oblivious layout can be built in $\textit{O(N}\text{log}\textit{(NK))}$ processor operations.

97 MATHEMATICS AND COMPUTING↗

Investigation of competitive sorption and plasticization of hyperaged CANAL ladder polymers for acid gas purification

Identifying membrane materials that have exceptional separation performance and stability to complex CO 2 -containing mixtures is a pressing topic in separation science. In this work, the membrane separation performance for a recently discovered class of contorted polymers synthesized via catalytic arene-norbornene annulation (CANAL) polymerization is presented. These CANAL polymers achieve high CO 2 /CH 4 selectivity of 68 after physical aging (up to ∼1 year), which significantly augments the size-sieving capabilities of the membranes. Binary CO 2 /CH 4 and ternary H 2 S/CO 2 /CH 4 testing result in a 41 % and 50 % enhancement in selectivities, respectively, for hyperaged (∼1 year) contorted CANAL polymers, highlighting their size-sieving capabilities. The remarkably high CO 2 /CH 4 mixed-gas and combined acid gas (CAG, (CO 2 +H 2 S)/CH 4 ) selectivities of 88 and 95, respectively, for CANAL-Me-S 5 F in particular surpass both the 2018 CO 2 /CH 4 mixed-gas and CAG upper bounds. Performance stability was also investigated for high concentrations of CO 2 , revealing a reduction in CO 2 /CH 4 mixed-gas selectivity without compromising CO 2 permeability, suggesting strong sorption of CO 2 but minimal plasticization effects for short testing periods. In addition, time-dependent plasticization shows negligible effects on CO 2 /CH 4 mixed-gas selectivity despite an increase in CO 2 permeability when exposed to high concentrations of plasticizing CO 2 over an extended period of 170 h. This study provides valuable insights into hyperaged CANAL polymers and their performance in practical industrial processes.

03 NATURAL GAS↗

Joint Sparsity Pattern Recovery With 1-b Compressive Sensing in Distributed Sensor Networks

In this paper, we study the problem of joint sparse support recovery with 1-b quantized compressive measurements in a distributed sensor network. Multiple nodes in the network are assumed to observe sparse signals having the same but unknown sparse support. Each node quantizes its measurement vector element-wise to 1 b. First, we consider that all the quantized measurements are available at a central fusion center. We derive performance bounds for sparsity pattern recovery using 1-bit quantized measurements from multiple sensors when the maximum likelihood decoder is employed. We further develop two computationally tractable algorithms for joint sparse support recovery in the centralized setting. One algorithm minimizes a cost function defined as the sum of the likelihood function and the l-∝ quasi-norm, while the other algorithm extends the binary iterative hard thresholding algorithm to the multiple measurement vector case. Second, we consider a decentralized setting where each node transmits 1-b measurements to its one-hop neighbors. The basic idea behind the algorithms developed in the decentralized setting is to embed collaboration among nodes and fusion strategies. We show that even with noisy 1-b compressed measurements, joint support recovery can be carried out accurately in both centralized and decentralized settings. Additionally, we further show that the performance of the proposed 1-bit compressive sensing-based algorithms is very close to that of their real-valued counterparts except when the signal-to-noise ratio is very small.

97 MATHEMATICS AND COMPUTING↗

Design of Mini-Plate-1 Irradiation Test for Qualification of High-Density, Low-Enriched U-10Mo Monolithic Fuel

The United States High Performance Research Reactor project is tasked with fuel development and qualification leading to conversion of higher power research and test reactors in the US from high-enriched uranium (HEU) to low-enriched uranium (LEU) fuels. Here, this manuscript identifies the functional and operational design requirements of the first miniature test plate (mini-plate [MP]) irradiation campaign (MP-1) of commercially fabricated LEU U-10Mo monolithic plate-type fuel and is the precursor to a large parametric mini-plate test (MP-2) aimed at producing the data to support regulatory qualification of the LEU U-10Mo monolithic fuel. The manuscript (1) provides a general description of the selected U-10Mo LEU fuel and (2) defines the overall experiment design and functional requirements to accomplish the specific test objective of MP-1, which is to confirm that the commercially manufactured LEU U-10Mo monolithic fuel meets the established requirements of geometric stability, mechanical integrity and stable and predictable behavior. The fuel testing parameters are established by the need to bound performance behavior within the operational envelope of the reactors being converted.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Providing performance portable numerics for Intel GPUs

Summary With discrete Intel GPUs entering the high‐performance computing landscape, there is an urgent need for production‐ready software stacks for these platforms. In this article, we report how we enable the Ginkgo math library to execute on Intel GPUs by developing a kernel backed based on the DPC++ programming environment. We discuss conceptual differences between the CUDA and DPC++ programming models and describe workflows for simplified code conversion. We evaluate the performance of basic and advanced sparse linear algebra routines available in Ginkgo's DPC++ backend in the hardware‐specific performance bounds and compare against routines providing the same functionality that ship with Intel's oneMKL vendor library.

97 MATHEMATICS AND COMPUTING↗

SUSPECT: MINLP special structure detector for Pyomo

We present SUSPECT, an open source toolkit that symbolically analyzes mixed-integer nonlinear optimization problems formulated using the Python algebraic modeling library Pyomo. We present the data structures and algorithms used to implement SUSPECT. SUSPECT works on a directed acyclic graph representation of the optimization problem to perform: bounds tightening, bound propagation, monotonicity detection, and convexity detection. We show how the tree-walking rules in SUSPECT balance the need for lightweight computation with effective special structure detection. SUSPECT can be used as a standalone tool or as a Python library to be integrated in other tools or solvers. Here, we highlight the easy extensibility of SUSPECT with several recent convexity detection tricks from the literature. We also report experimental results on the MINLPLib 2 dataset.

97 MATHEMATICS AND COMPUTING↗

Design optimization of semiconductor piezoresistors with Schottky diode contacts

A modeling theory is developed to predict the performance of piezoresistors which incorporate Schottky diode electrical contacts. This new theory allows the design of high performance gauges which can be fabricated using NonLithographically-Based Microfabrication (NLBM) techniques. These semiconductor piezoresistors can be designed in customizable sizes and fabricated in parallel in order to integrate position sensing into MEMS flexural positioners. Customizable nanopositioning platforms will enable advances in a range of nano-scale fabrication and metrology applications. A semiconductor piezoresistor with Schottky diode contacts was fabricated and attached to a titanium flexure. This device is shown to match predicted electrical performance within about 8% and to show a gauge factor of 116, within 2% of the predicted value. Performance limits for Schottky diode semiconductor piezoresistors are identified to be about 127dB full noise dynamic range for a quarter bridge over a 10kHz sensor bandwidth on a 600µm width titanium flexure, making them ideal for sensing on meso-/micro-scale flexural positioners. Methods of reaching these performance bound are suggested and their impact on the sensor dynamic range are studied.

42 ENGINEERING↗

X-ray tomography system to investigate granular materials during mechanical loading

We integrate a small and portable medical x-ray device with mechanical testing equipment to enable in situ, non-invasive measurements of a granular material's response to mechanical loading. We employ an orthopedic C-arm as the x-ray source and detector to image samples mounted in the materials tester. We discuss the design of a custom rotation stage, which allows for sample rotation and tomographic reconstruction under applied compressive stress. We then discuss the calibration of the system for 3D computed tomography, as well as the subsequent image reconstruction process. Using this system to reconstruct packings of 3D-printed particles, we resolve packing features with 0.52 mm resolution in a (60 mm){sup 3} field of view. By analyzing the performance bounds of the system, we demonstrate that the reconstructions exhibit only moderate noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASMDR: a framework for miRNA-drug resistance prediction using efficient neural architecture search and graph isomorphism networks

Abstract As a frontier field of individualized therapy, microRNA (miRNA) pharmacogenomics facilitates the understanding of different individual responses to certain drugs and provides a reasonable reference for clinical treatment. However, the known drug resistance-associated miRNAs are not yet sufficient to support precision medicine. Although existing methods are effective, they all focus on modelling miRNA-drug resistance interaction graphs, making their performance bounded by the interaction density. In this study, we propose a framework for miRNA-drug resistance prediction through efficient neural architecture search and graph isomorphism networks (NASMDR). NASMDR uses attribute information instead of the commonly used interactive graph information. In the cross-validation experiment, the proposed framework can achieve an AUC of 0.9468 on the ncDR dataset, which is 2.29% higher than the state-of-the-art method. In addition, we propose a novel sequence characterization approach, k-mer Sparse Nonnegative Matrix Factorization (KSNMF). The results show that NASMDR provides novel insights for integrating efficient neural architecture search and graph isomorphic networks into a unified framework to predict drug resistance-related miRNAs. The codes for NASMDR are available at https://github.com/kaizheng-academic/NASMDR.

Zheng, Kai↗

Cyber Graph Queries for Geographically Distributed Data Centers

We present new algorithms for a distributed model for graph computations motivated by limited information sharing we first discussed. Two or more independent entities have collected large social graphs. They wish to compute the result of running graph algorithms on the entire set of relationships. Because the information is sensitive or economically valuable, they do not wish to simply combine the information in a single location. We consider two models for computing the solution to graph algorithms in this setting: 1) limited-sharing: the two entities can share only a polylogarithmic size subgraph; 2) low-trust: the entities must not reveal any information beyond the query answer, assuming they are all honest but curious. We believe this model captures realistic constraints on cooperating autonomous data centers. We have algorithms in both setting for s - t connectivity in both models. We also give an algorithm in the low-communication model for finding a planted clique. This is an anomaly-detection problem, finding a subgraph that is larger and denser than expected. For both the low- communication algorithms, we exploit structural properties of social networks to prove performance bounds better than what is possible for general graphs. For s - t connectivity, we use known properties. For planted clique, we propose a new property: bounded number of triangles per node. This property is based upon evidence from the social science literature. We found that classic examples of social networks do not have the bounded-triangles property. This is because many social networks contain elements that are non-human, such as accounts for a business, or other automated accounts. We describe some initial attempts to distinguish human nodes from automated nodes in social networks based only on topological properties.

97 MATHEMATICS AND COMPUTING↗

Report on Year-2 of Water NSTF Matrix Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems of advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-3 of Water NSTF Matrix Testing: Two-Phase Parametric Test Series

The Natural convection Shutdown heat removal Test Facility (NSTF) is large scale test facility constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactor concepts. With support from the Department of Energy (DOE) offices of Advanced Reactor Technologies (ART) and Advanced Reactors Regulatory Development (RD), this facility reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal SCR Control Using Data-Driven Models

We present an optimal control solution for the urea injection for a heavy-duty diesel (HDD) selective catalytic reduction (SCR). The approach taken here is useful beyond SCR and could be applied to any system where a control strategy is desired and input-output data is available. For example, the strategy could also be used for the diesel oxidation catalyst (DOC) system. In this paper, we identify and validate a one-step ahead Kalman state-space estimator for downstream NOx using the bench reactor data of an SCR core sample. The test data was acquired using a 2010 Cummins 6.7L ISB production engine with a 2010 Cummins production aftertreatment system. We used a surrogate HDD federal test procedure (FTP), developed at Michigan Technological University (MTU), which simulates the representative transients of the standard FTP cycle, but has less engine speed/load points. The identified state-space model is then used to develop a tunable cost function that simultaneously minimizes NOx emissions and urea usage. The cost function is quadratic and univariate, thus the minimum can be computed analytically. We show the performance of the closed-loop controller in using a reduced-order discrete SCR simulator developed at MTU. Our experiments with the surrogate HDD-FTP data show that the strategy developed in this paper can be used to identify performance bounds for urea dose controllers.

diesel, emmissions, control, environment, modeling↗

Detection and estimation theory

Dynamic systems, and electronic theory on nonlinear intervals, and performance bounds of optimum detection for Gaussian signals

ELECTRONICS↗