Status of Terra MODIS Operation, Calibration, and Performance

Since launch in December 1999, Terra MODIS has successfully operated for nearly 15 years, making continuous observations. Data products derived from MODIS observations have significantly contributed to a wide range of studies of key geophysical parameters of the earth's eco-system of land, ocean, and atmosphere, and their changes over time. The quality of MODIS data products relies on the dedicated effort to monitor and sustain instrument health and operation, to calibrate and update sensor parameters and properties, and to improve calibration algorithms. MODIS observations are made in 36 spectral bands, covering wavelengths from visible to long-wave infrared. The reflective solar bands (1-19 and 26) are primarily calibrated by a solar diffuser (SD) panel and regularly scheduled lunar observations. The thermal emissive bands (20-25 and 27- 36) calibration is referenced to an on-board blackbody (BB) source. On-orbit changes in the sensor spectral and spatial characteristics are monitored by a spectroradiometric calibration assembly (SRCA). This paper provides an overview of Terra MODIS on-orbit operation and calibration activities and implementation strategies. It presents and summarizes sensor on-orbit performance using nearly 15 years of data from its telemetry, on-board calibrators, and lunar observations. Also discussed in this paper are changes in sensor characteristics, corrections applied to maintain MODIS level 1B (L1B) data quality, and efforts for future improvements.

Terra↗

S-NPP VIIRS Calibration and Performance Update

The first VIIRS instrument has successfully operated for more than 4 years on-board the Suomi-National Polar-orbiting Partnership (S-NPP) spacecraft. The sensor data records (SDR) derived from VIIRS on-orbit observations have been used to produce many environment data records (EDR), enabling a wide range of applications by the users from operational and research community. This paper provides an overview of instrument operations and its calibration activities, and presents an update of its radiometric performance, in terms of on-orbit changes in sensor spectral band responses and noise characterization. It also describes the effort made to improve sensor calibration, and the strategies developed in support of producing consistent SDR and, consequently, the EDR with improved quality.

Xiong, X.↗

Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB

As SuperCDMS SNOLAB is getting ready to search for low mass dark matter particles, using cryogenic Ge and Si detectors, a set of six of the new SuperCDMS High Voltage (HV) detectors (four Ge and two Si) were tested in the Cryogenic Underground TEst facility (CUTE) at SNOLAB. This provided the first opportunity to gain experience with this new detector type and assess their performance thoroughly under low background conditions. Here we describe the SuperCDMS HV detector concept and discuss some of the newly developed analysis methods and approaches. Focusing on the Ge detectors, we investigate the detector performance under voltage bias (up to 90 V), exercise the low energy (keV to sub-keV range) calibration based on the electron capture peaks generated by the decay of $^{71}$Ge, assess the detector resolution, and demonstrate the unexpected (and encouraging) ability of these detectors to also measure high energy interactions in the hundreds of keV range with good resolution (better than 3% at 356 keV).

Albakry, M. F. [British Columbia U.; TRIUMF]↗

Multiyear On-orbit Calibration and Performance of Terra MODIS Thermal Emissive Bands

Since launch in December 1999, Terra MODIS has been making continuous Earth observations for more than seven years. It has produced a broad range of land, ocean, and atmospheric science data products for improvements in studies of global climate and environmental change. Among its 36 spectral bands, there are 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). MODIS thermal emissive bands cover the mid-wave infrared (MWIR) and long-wave infrared (LWIR) spectral regions with wavelengths from 3.7 to 14.4pm. They are calibrated on-orbit using an on-board blackbody (BB) with its temperature measured by a set of thermistors on a scan-by-scan basis. This paper will provide a brief overview of MODIS TEB calibration and characterization methodologies and illustrate on-board BB functions and TEB performance over more than seven years of on-orbit operation and calibration. Discussions will be focused on TEB detector short-term stability and noise characterization, and changes in long-term response (or system gain). Results show that Terra MODIS BB operation has been extremely stable since launch. When operated at its nominal controlled temperature of 290K, the BB temperature variation is typically less than +0.30mK on a scan-by-scan basis and there has been no time-dependent temperature drift. In addition to excellent short-term stability, most TEB detectors continue to meet or exceed their specified noise characterization requirements, thus enabling calibration accuracy and science data product quality to be maintained. Excluding the noisy detectors identified pre-launch and those that occurred post-launch, the changes in TEB responses have been less than 0.7% on an annual basis. The optical leak corrections applied to bands 32-36 have been effective and stable over the entire mission

Xiong, Xiaoxiong↗

Terra and Aqua MODIS Thermal Emissive Bands On-Orbit Calibration and Performance

Since launch, the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments on the Terra and Aqua spacecraft have operated successfully for more than 14 and 12 years, respectively. A key instrument for National Aeronautics and Space Administration Earth Observing System missions, MODIS was designed to make continuous observations for studies of Earth's land, ocean, and atmospheric properties and to extend existing data records from heritage Earth observing sensors. The 16 thermal emissive bands (TEBs) (3.75-14.24 micrometers) are calibrated on orbit using a temperature controlled blackbody (BB). Both Terra and Aqua MODIS BBs have displayed minimal drift over the mission lifetime, and the seasonal variations of the BB temperature are extremely small in Aqua MODIS. The long-term gain and noise equivalent difference in temperature performance of the 160 TEB detectors on both MODIS instruments have been well behaved and generally very stable. Small but noticeable variations of Aqua MODIS bands 33-36 (13.34-14.24 micrometer) response in recent years are primarily due to loss of temperature control margin of its passive cryoradiative cooler. As a result, fixed calibration coefficients, previously used by bands when the BB temperature is above their saturation temperatures, are replaced by the focal-plane-temperature-dependent calibration coefficients. This paper presents an overview of the MODIS TEB calibration, the on-orbit performance, and the challenging issues likely to impact the instruments as they continue operating well past their designed lifetime of six years.

TEBs↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

An Early Assessment of JPSS-1/NOAA-20 VIIRS Day-Night Band On-Orbit Calibration and Performance

The JPSS-1 (now named NOAA-20) VIIRS instrument has been successfully operating on orbit since November 28th, 2017. The Day-Night Band (DNB) is a panchromatic channel covering wavelengths from 0.5 to 0.9 m that is capable of observing the Earth scene in visible/near-Infrared spectral range at spatial resolution of 750 m. The DNB operates at low, mid, or high radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low gain stage calibration. The SD observations also provide a mean to compute gain ratios between low-to-mid and mid-to-high gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. This paper provides an early assessment of the DNB on-orbit performance and behavior in the first 90-day post launch test (PLT) period and beyond. The calibration methodology used by the VIIRS Characterization Support Team (VCST) in support of the NASA earth science community will be presented. The trending of OBC dark-offsets, SD gains and gain ratios, and signal-to-noise ratio (SNR) at minimum radiance have been analyzed, especially during key events such as the Nadir and Cryo-cooler doors opening. Furthermore, we performed inter-comparison studies between SNPP and JPSS-1 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains and gain ratios, as well as the calibration comparison between the IDPS LUTs and our VCST delivery results.

Chen, H.↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

MODIS Reflective Solar Bands On-Orbit Calibration and Performance

The design of the MODIS instrument was driven by the scientific community's desire to have near-daily global coverage at moderate resolution (1 km) with a comprehensive spectral coverage from visible to long-wave infrared wavelengths. Since their launches in 1999 and 2002, respectively, the Terra and Aqua MODIS instruments have made continuous global observations and generated numerous data products to help users worldwide with their studies of the Earth's system and its short- and long-term changes. The 20 reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 m collect data at three nadir spatial resolutions: 250 m, 500 m, and 1 km. The solar diffuser (SD) coupled with the solar diffuser stability monitor (SDSM) provide a reflectance-based calibration on-orbit. In addition, lunar observations and response trends from pseudo-invariant desert sites are used to characterize the response versus scan- angle changes on-orbit. This paper provides a brief overview of MODIS RSB calibration algorithms, as implemented in the latest Level 1B version 6.1, operational activities, on-orbit performance, remaining challenges and potential improvements. Results from the SD and SDSM measurements show a wavelength and mirror side dependent degradation in RSB responses, with the largest degradation at the shortest wavelengths, particularly for Terra MODIS. Aqua MODIS has experienced far less degradation of its optics and on-board calibrators compared to Terra MODIS, resulting in an overall better performance. With the exception of Aqua band 6, there have been no new noisy or inoperable detectors in the RSB of either instrument during post-launch operations. As the instruments age and continue to endure the space environment, the detectors and optical systems degrade. The challenges associated with incorporating these on-orbit changes to ensure a production of high-quality calibrated L1B data products are also discussed in this paper.

solar diffuser stability monitor↗

Terra MODIS: 20 years of on-orbit calibration and performance

For nearly 20 years, Terra MODIS observations have generated a broad range of data products, enabling the remote sensing community and users worldwide for their studies of many key geophysical parameters of the Earth’s system. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, that are calibrated by a set of on-board calibrators (OBC). Also contributed to sensor on-orbit calibration and characterization are near monthly-scheduled lunar observations and long-term trends of sensor responses over select ground targets. The quality of MODIS data products relies strongly on the dedicated efforts to the operate instrument, derive and update calibration parameters, and improve calibration strategies and algorithms in order to address on-orbit changes of sensor characteristics and its OBC functions. This paper provides an overview of Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve instrument and OBC functions and their implementation strategies. It illustrates sensor on-orbit performance using data from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms or updates of calibration look-up tables (LUTs). Also described in this paper are lessons learned from Terra MODIS and future efforts to further extend its long-term data records.

Terra↗

On-Orbit Performance and Calibration Improvements For the Reflective Solar Bands of Terra and Aqua MODIS

Moderate Resolution Imaging Spectroradiometer (MODIS) is the keystone instrument for NASAs EOS Terra and Aqua missions, designed to extend and improve heritage sensor measurements and data records of the land, oceans and atmosphere. The reflective solar bands (RSB) of MODIS covering wavelengths from 0.41 micrometers to 2.2 micrometers, are calibrated on-orbit using a solar diffuser (SD), with its on-orbit bi-directional reflectance factor (BRF) changes tracked using a solar diffuser stability monitor (SDSM). MODIS is a scanning radiometer using a two-sided paddle-wheel mirror to collect earth view (EV) data over a range of (+/-)55 deg. off instrument nadir. In addition to the solar calibration provided by the SD and SDSM system, lunar observations at nearly constant phase angles are regularly scheduled to monitor the RSB calibration stability. For both Terra and Aqua MODIS, the SD and lunar observations are used together to track the on-orbit changes of RSB response versus scan angle (RVS) as the SD and SV port are viewed at different angles of incidence (AOI) on the scan mirror. The MODIS Level 1B (L1B) Collection 6 (C6) algorithm incorporated several enhancements over its predecessor Collection 5 (C5) algorithm. A notable improvement was the use of the earth-view (EV) response trends from pseudo-invariant desert targets to characterize the on-orbit RVS for select RSB (Terra bands 1-4, 8, 9 and Aqua bands 8, 9) and the time, AOI, and wavelength-dependent uncertainty. The MODIS Characterization Support Team (MCST) has been maintaining and enhancing the C6 algorithm since its first update in November, 2011 for Aqua MODIS, and February, 2012 for Terra MODIS. Several calibration improvements have been incorporated that include extending the EV-based RVS approach to other RSB, additional correction for SD degradation at SWIR wavelengths, and alternative approaches for on-orbit RVS characterization. In addition to the on-orbit performance of the MODIS RSB, this paper also discusses in detail the recent calibration improvements implemented in the MODIS L1B C6.

Angal, Amit↗

Calibration and performance of the ATLAS Tile Calorimeter during the LHC Run 2

The Tile Calorimeter (TileCal) is the hadronic sampling calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). TileCal uses iron absorbers and scintillators as active material and it covers the central region | η| < 1.7. Jointly with the other sub-detectors it is designed for measurements of hadrons, jets, tau-particles and missing transverse energy. It also assists in muon identification. TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source, a laser light system to check the PMT response, and a charge injection system (CIS) to check the front-end electronics. These calibration systems, in conjunction with data collected during proton-proton collisions, Minimum Bias (MB) events, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of the signal propagation. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions and compared to Monte Carlo (MC) simulations. The response of high momentum isolated muons is also used to study the energy response at the electromagnetic scale, isolated hadrons are used as a probe of the hadronic response. The calorimeter time resolution is studied with multijet events. A description of the different TileCal calibration systems and the results on the calorimeter performance during the LHC Run 2 are introduced. The findings on the pile-up noise and response uniformity studies are also reported on.

47 OTHER INSTRUMENTATION↗

Suomi-NPP VIIRS Day-Night Band On-Orbit Calibration and Performance

The Suomi national polar-orbiting partnership Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has successfully operated since its launch in October 2011. The VIIRS day-night band (DNB) is a panchromatic channel covering wavelengths from 0.5 to 0.9 microns that is capable of observing Earth scenes during both daytime and nighttime at a spatial resolution of 750 m. To cover the large dynamic range, the DNB operates at low-, middle-, and high-gain stages, and it uses an on-board solar diffuser (SD) for its low-gain stage calibration. The SD observations also provide a means to compute the gain ratios of low-to-middle and middle-to-high gain stages. This paper describes the DNB on-orbit calibration methodology used by the VIIRS characterization support team in supporting the NASA Earth science community with consistent VIIRS sensor data records made available by the land science investigator-led processing systems. It provides an assessment and update of the DNB on-orbit performance, including the SD degradation in the DNB spectral range, detector gain and gain ratio trending, and stray-light contamination and its correction. Also presented in this paper are performance validations based on Earth scenes and lunar observations, and comparisons to the calibration methodology used by the operational interface data processing segment.

Chen, Hongda↗

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Solar Sounding Rocket Campaign – Calibration and Performance

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that is designed to observe, for the first time, soft X-ray spectra of high-temperature, low-emission plasma of coronal structures spatially resolved along a narrow slit.MaGIXS observation involves a set of high temperature spectral lines in soft X-rays from 0.5 - 2.0 keV from an active region core,which will extend the DEM coverage from 3MK to 10MK constraining the slope of the DEM fall-off. The novel instrument designincludes a Wolter-I type telescope and a 3-optic grazing-incidence spectrometer. The spectrometer consists of a finite conjugatemirror pair and a blazed planar, varied line spaced grating, which disperses the rays on to a CCD and provides a high spatial andspectral resolution. Component level instrument testing, integration of the instrument and end-to-end X-ray calibration are carriedout using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. MaGIXS is scheduled for launch in2021. We will present the results of X-ray calibration tests for MaGIXS and discuss the expected inflight performance throughdifferent solar observation scenarios.

P. S. Athiray↗

Lunar calibration and performance assessments of the NOAA-20 VIIRS reflective solar bands

The Moon has played a vital role in the radiometric stability monitoring of NASAs Earth Observing System sensors, such as MODIS on the Terra and Aqua spacecrafts. The lunar calibration methodologies developed for the two MODIS instruments were later extended to apply to the VIIRS instrument on the Suomi-NPP spacecraft. The follow-on VIIRS instrument on the NOAA-20 (N20) spacecraft (previously JPSS-1) has been successfully operating since its launch in November 2017. Fifteen VIIRS spectral bands are in the reflective solar spectral region, covering wavelengths from 0.4 to 2.3 μm. Similar to the previous MODIS and VIIRS instruments, the N20 VIIRS views the Moon via a spacecraft roll maneuver on a near-monthly basis at a confined phase angle range (-51.5° to -50.5°) to facilitate radiometric stability monitoring with reduced uncertainties. In this paper, we briefly present the lunar calibration methodology and also report the derived instrument gain parameters from the regularly scheduled lunar calibrations. The USGS Robotic Lunar Observatory (ROLO) model is used to provide the predicted lunar irradiance for each lunar measurement to account for the variation in the observation geometry. The spatial characterization algorithms using the Moon, previously developed for MODIS and SNPP VIIRS, have also been extended to N20 VIIRS to track its on-orbit band-to-band registration (BBR).

VIIRS↗

Terra MODIS: 20 years of on-orbit calibration and performance

Since its launch in December 1999, Terra Moderate Resolution Imaging Spectroradiometer (MODIS) has successfully operated for more than 20 years, with its observations generating a broad range of science data products that have greatly enabled the remote sensing community and users worldwide in their studies of many key geophysical parameters of the Earth’s systems. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, which are calibrated by a set of onboard calibrators (OBCs). Also contributing to the sensor’s mission-long on-orbit calibration and characterization are near-monthly scheduled lunar observations and multiple time series of the sensor’s responses over select ground targets at a variety of scan angles. To a large extent, the quality of MODIS data products relies strongly on the dedicated efforts to operate and calibrate the instrument, to derive and update calibration parameters, and to develop and implement new calibration strategies and algorithms in response to on-orbit changes of the sensor’s characteristics and its OBC functions. We provide an overview of the Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve the instrument and OBC functions and their operation strategies. It also illustrates the sensor’s on-orbit performance with results derived from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms as well as calibration lookup table updates. To date, the Terra MODIS instrument and its OBCs continue to operate and function normally. Except for those identified prelaunch, most spectral bands and detectors continue to meet their specified calibration requirements. Also discussed in our paper are lessons learned from Terra MODIS operation and calibration, as well as future efforts to further extend and maintain the quality of its long-term data records.

Terra↗

Calibration and performance of the energetic X-ray imaging telescope experiment

The final integration and testing of the Energetic X-ray Imaging Telescope Experiment (EXITE) are described. The detector and telescope as finally assembled are described, and problems as well as solutions are detailed. The preflight calibration of the position-sensitive NaI detector revealed unanticipated effects in the energy spectra. In particular, an effect due to surface roughness (lack of firm optical polishing) on the crystal was found and calibrated. The radial variation of gain and resolution in the detector was also measured, and so-called flat fielding methods have been derived to analyze the data. The integration of the EXITE detector and gondola systems is described. Several novel features were developed for the EXITE gondola, most notably a shock absorber system. The performance of the detector and gondola systems was evaluated on a first balloon flight from Australia (May 1988) and a second flight from Ft. Sumner, New Mexico (October 1988).

Braga, Joao↗

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]↗