Search NASA⌕ Search

SEARCH · Search NASA

Results for “persistent image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The 1999 Leonid Multi-Instrument Aircraft Campaign - An Early Review

The Leonid meteor storm of 1999 was observed from two B707-type research aircraft by a team of 35 scientists of seven nationalities over the Mediterranean Sea on Nov. 18, 1999. The mission was sponsored by various science programs of NASA, and offered the best possible observing conditions, free of clouds and at a prime location for viewing the storm. The 1999 mission followed a similar effort in 1998, improving upon mission strategy and scope. As before, spectroscopic and imaging experiments targeted meteors and persistent trains, but also airglow, aurora, elves and sprites. The research aimed to address outstanding questions in Planetary Science, Astronomy, Astrobiology and upper atmospheric research, including Aeronornie. In addition, near real-time flux measurements contributed to a USAF sponsored program for space weather awareness. An overview of the first results is given, which are discussed in preparation for future missions.

Jenniskens, Peter↗

Anastomosing hemangioma of the liver: a case series

Purpose: To report imaging and pathologic features of five pathologically proven anastomosing hemangiomas of the liver (AHL). Methods: A retrospective review for AHL was conducted using our institutional database from 6/2004 to 3/2018. Histology proven AHL with radiologic imaging available for review were included. A total of five patients who met our criteria were identified from our institutional database. Computed tomography, ultrasound, and magnetic resonance imaging findings, including location, size, attenuation/signal intensity, enhancement characteristics, and additional imaging data were reviewed. The clinical and pathological data were also reviewed. Results: The imaging characteristics of AHL are variable, but features such as peripheral or diffuse hyperintensity on diffusion weighted imaging, arterial hyperenhancement without globular interrupted enhancement, and persistent enhancement without complete filling in the delayed phases were more characteristic of AHL. Imaging also demonstrated a lack of aggressive features. Conclusions: AHL present a diagnostic dilemma as they can mimic more malignant lesions, such as angiosarcoma, both on imaging and at pathology. While the imaging characteristics of AHL are variable, there are some features which can help distinguish AHL from other liver lesions. When the diagnosis of anastomosing hemangioma is known, the management of choice is primarily surveillance, as intervention can cause unnecessary morbidity, and no degeneration to malignancy has been identified to date.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial DIC Errors due to Pattern-Induced Bias and Grey Level Discretization

Digital image correlation (DIC) is an optical metrology method widely used in experimental mechanics for full-field shape, displacement and strain measurements. The required strain resolution for engineering applications of interest mandates DIC to have a high image displacement matching accuracy, on the order of 1/100th of a pixel, which necessitates an understanding of DIC errors. In this paper, we examine two spatial bias terms that have been almost completely overlooked. They cause a persistent offset in the matching of image intensities and thus corrupt DIC results. We name them pattern-induced bias (PIB), and intensity discretization bias (IDB). We show that the PIB error occurs in the presence of an undermatched shape function and is primarily dictated by the underlying intensity pattern for a fixed displacement field and DIC settings. The IDB error is due to the quantization of the gray level intensity values in the digital camera. In this paper we demonstrate these errors and quantify their magnitudes both experimentally and with synthetic images.

47 OTHER INSTRUMENTATION↗

Monitoring radiation use in cardiac fluoroscopy imaging procedures

Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance associated with relocation of the equipment to a new department. When tested under simulated conditions, the EWMA chart was capable of detecting a sustained 15% increase in average radiation output within 60 cases (<1 month of operation), while a 33% increase would be signaled within 20 cases. Conclusions: This technique offers a valuable enhancement to existing quality assurance programs in radiology that rely upon the testing of equipment radiation output at discrete time frames to ensure performance security.

60 APPLIED LIFE SCIENCES↗

Local optical control of ferromagnetism and chemical potential in a topological insulator

Many proposed experiments involving topological insulators (TIs) require spatial control over time-reversal symmetry and chemical potential. We demonstrate reconfigurable micron-scale optical control of both magnetization (which breaks time-reversal symmetry) and chemical potential in ferromagnetic thin films of Cr-(Bi,Sb) 2 Te 3 grown on SrTiO 3 . By optically modulating the coercivity of the films, we write and erase arbitrary patterns in their remanent magnetization, which we then image with Kerr microscopy. Additionally, by optically manipulating a space charge layer in the underlying SrTiO 3 substrates, we control the local chemical potential of the films. This optical gating effect allows us to write and erase p-n junctions in the films, which we study with photocurrent microscopy. Both effects are persistent and may be patterned and imaged independently on a few-micron scale. As a result, dynamic optical control over both magnetization and chemical potential of a TI may be useful in efforts to understand and control the edge states predicted at magnetic domain walls in quantum anomalous Hall insulators.

36 MATERIALS SCIENCE↗

An Extraordinary Outburst in the Massive Protostellar System NGC 6334I-MM1: Quadrupling of the Millimeter Continuum

Based on sub-arcsecond Atacama Large Millimeter/submillimeter Array (ALMA) and Submillimeter Array (SMA) 1.3 mm continuum images of the massive protocluster NGC 6334I obtained in 2015 and 2008, we find that the dust emission from MM1 has increased by a factor of 4.0 ± 0.3 during the intervening years, and undergone a significant change in morphology. The continuum emission from the other cluster members (MM2, MM4, and the UCH ii region MM3 = NGC 6334F) has remained constant. Long-term single-dish maser monitoring at HartRAO finds that multiple maser species toward NGC 6334I flared beginning in early 2015, a few months before our ALMA observation, and some persist in that state. New ALMA images obtained in 2016 July–August at 1.1 and 0.87 mm confirm the changes with respect to SMA 0.87 mm images from 2008, and indicate that the (sub)millimeter flaring has continued for at least a year. The excess continuum emission, centered on the hypercompact H ii region MM1B, is extended and elongated (1.″6 × 1.″0 ≈ 2100 × 1300 au) with multiple peaks, suggestive of general heating of the surrounding subcomponents of MM1, some of which may trace clumps in a fragmented disk rather than separate protostars. In either case, these remarkable increases in maser and dust emission provide direct observational evidence of a sudden accretion event in the growth of a massive protostar yielding a sustained luminosity surge by a factor of 70 ± 20, analogous to the largest events in simulations by Meyer et al. This target provides an excellent opportunity to assess the impact of such a rare event on a protocluster over many years.

79 ASTRONOMY AND ASTROPHYSICS↗

Functional Imaging of Microbial Interactions With Tree Roots Using a Microfluidics Setup

Coupling microfluidics with microscopy has emerged as a powerful approach to study at cellular resolution the dynamics in plant physiology and root-microbe interactions (RMIs). Most devices have been designed to study the model plant Arabidopsis thaliana at higher throughput than conventional methods. However, there is a need for microfluidic devices which enable in vivo studies of root development and RMIs in woody plants. Here, we developed the RMI-chip, a simple microfluidic setup in which Populus tremuloides (aspen tree) seedlings can grow for over a month, allowing continuous microscopic observation of interactions between live roots and rhizobacteria. We find that the colonization of growing aspen roots by Pseudomonas fluorescens in the RMI-chip involves dynamic biofilm formation and dispersal, in keeping with previous observations in a different experimental set-up. Also, we find that whole-cell biosensors based on the rhizobacterium Bacillus subtilis can be used to monitor compositional changes in the rhizosphere but that the application of these biosensors is limited by their efficiency at colonizing aspen roots and persisting. These results indicate that functional imaging of dynamic root-bacteria interactions in the RMI-chip requires careful matching between the host plant and the bacterial root colonizer.

59 BASIC BIOLOGICAL SCIENCES↗

Advanced High-Speed Framing Camera Development for Fast, Visible Imaging Experiments

The advances in high-voltage switching developed in this project allow a camera user to rapidly vary the number of output frames from 1 to 25. A high-voltage, variable-amplitude pulse train shifts the deflection location to the new frame location during the interlude between frames, making multiple frame counts and locations possible. The final deflection circuit deflects to five different frame positions per axis, including the center position, making for a total of 25 frames. To create the preset voltages, electronically adjustable {+-}500 V power supplies were chosen. Digital-to-analog converters provide digital control of the supplies. The power supplies are clamped to {+-}400 V so as not to exceed the voltage ratings of the transistors. A field-programmable gated array (FPGA) receives the trigger signal and calculates the combination of plate voltages for each frame. The interframe time and number of frames are specified by the user, but are limited by the camera electronics. The variable-frame circuit shifts the plate voltages of the first frame to those of the second frame during the user-specified interframe time. Designed around an electrostatic image tube, a framing camera images the light present during each frame (at the photocathode) onto the tube’s phosphor. The phosphor persistence allows the camera to display multiple frames on the phosphor at one time. During this persistence, a CCD camera is triggered and the analog image is collected digitally. The tube functions by converting photons to electrons at the negatively charged photocathode. The electrons move quickly toward the more positive charge of the phosphor. Two sets of deflection plates skew the electron’s path in horizontal and vertical (x axis and y axis, respectively) directions. Hence, each frame’s electrons bombard the phosphor surface at a controlled location defined by the voltages on the deflection plates. To prevent the phosphor from being exposed between frames, the image tube is gated off between exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiparameter spatio-thermochemical probing of flame–wall interactions advanced with coherent Raman imaging

Ultrabroadband coherent anti-Stokes Ra man spectroscopy (CARS) has been developed for one -dimensional imaging of temperature and major species distributions simultaneously in the near-wall region of a methane/air flame supported on a side-wall-quenching (SWQ) burner. Automatic temporal and spatial overlap of the ~7 femtosecond pump and Stokes pulses is achieved utilizing a two-beam CARS phase-matching scheme, and the crossed ~75 picosecond probe beam provide s excellent spatial sectioning of the probed location. Concurrent detection of N 2 , O 2 , H 2 , CO, CO 2 , and CH 4 is demonstrated while high-fidelity flame thermometry is assessed from the N 2 pure rotational S-branch in a one-dimensional -CARS imaging configuration. A methane/air premixed flame at lean, stoichiometric, and rich conditions ( Φ = 0.83, 1.0 , and 1.2) and Reynolds number = 5,000 is probed as it quenches against a cooled steel side- wall parallel to the flow providing a persistent flame-wall interaction. Here, an imaging resolution of better than 40 μm is achieved across the field -of-view, thus allowing thermochemical states (temperature and major species) of the thermal boundary layer to be resolved to within ~30 μm of the interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RADIO ASTROMETRY OF THE TRIPLE SYSTEMS ALGOL AND UX ARIETIS

We have used multi-epoch long-baseline radio interferometry to determine the proper motion and orbital elements of Algol and UX Arietis, two radio-bright, close binary stellar systems with distant tertiary components. For Algol, we refine the proper motion and outer orbit solutions, confirming the recent result of Zavala et al. that the inner orbit is retrograde. The radio centroid closely tracks the motion of the KIV secondary. In addition, the radio morphology varies from double-lobed at low flux level to crescent-shaped during active periods. These results are most easily interpreted as synchrotron emission from a large, co-rotating meridional loop centered on the K star. If this is correct, it provides a radio-optical frame tie candidate with an uncertainty {+-}0.5 mas. For UX Arietis, we find an outer orbit solution that accounts for previous very long baseline interferometry observations of an acceleration term in the proper motion fit. The outer orbit solution is also consistent with previously published radial velocity curves and speckle observations of a third body. The derived tertiary mass, 0.75 solar masses, is consistent with the K1 main-sequence star detected spectroscopically. The inner orbit solution favors radio emission from the active K0IV primary only. The radio morphology, consisting of a single, partially resolved emission region, may be associated with the persistent polar spot observed using Doppler imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

How Excitation Conditions Alter the Afterglow Characteristics of CsI:Tl,Sm Microcolumnar Films

Combining high light output with the microcolumnar structure, the CsI:Tl films significantly reduce the need for painful tradeoff between thickness (hence, stopping power) and spatial resolution. But both films and monocrystals share two important deficiencies that hinder their use in many high-speed imaging and computed tomography applications: a persistent afterglow and hysteresis. These properties receive the primary attention of this investigation. In our earlier work, we reported that codoping with Sm 2+ brings about a significant reduction in the afterglow of CsI:Tl. Here, focusing on the microcolumnar films, we examine this afterglow-suppressive effect over a wide range of exposure times, from milliseconds to seconds, and at temperatures between 0 °C and 60 °C. Our measurements reveal well-defined dependences on both parameters. At room temperature (20 °C), defined as the normal operating condition, a 10-ms X-ray pulse leaves an afterglow from the standard (Sm-free) CsI:Tl of about 1% at 2 ms after the end of the pulse, changing little as a function of pulselength. Doping with Sm 2+ , however, reduces that afterglow by at least an order of magnitude, although somewhat less so after longer (100 and 1000 ms) pulses. When we change the temperature, however, we find markedly different behavior. Here, we find that a temperature increase of only 60°, without changing the pulselength, cuts the afterglow of standard CsI:Tl films by a factor of 20. However, films of codoped CsI:Tl,Sm, whose afterglow has already been suppressed by the presence of Sm 2+ , show much less change as a function of either temperature or pulse duration. It is the presence of Sm 2+ that makes the biggest difference. As for hysteresis, we again see an improvement, with the performance of the codoped CsI:Tl,Sm films bettering that of the standard (Sm-free) films. After an exposure of 300 mR, the change in light output falls to within 1% of the original after 1 min, whereas standard CsI:Tl films require 30 min to reach the same level.

42 ENGINEERING↗

Three-dimensional texture analysis of contrast enhanced CT images for treatment response assessment in Hodgkin lymphoma: Comparison with F-18-FDG PET

Purpose: To determine the diagnostic performance of three-dimensional (3D) texture analysis (TA) of contrast-enhanced computed tomography (CE-CT) images for treatment response assessment in patients with Hodgkin lymphoma (HL), compared with F-18-fludeoxyglucose (FDG) positron emission tomography/CT. Methods: 3D TA of 48 lymph nodes in 29 patients was performed on venous-phase CE-CT images before and after chemotherapy. All lymph nodes showed pathologically elevated FDG uptake at baseline. A stepwise logistic regression with forward selection was performed to identify classic CT parameters and texture features (TF) that enable the separation of complete response (CR) and persistent disease. Results: The TF fraction of image in runs, calculated for the 45° direction, was able to correctly identify CR with an accuracy of 75%, a sensitivity of 79.3%, and a specificity of 68.4%. Classical CT features achieved an accuracy of 75%, a sensitivity of 86.2%, and a specificity of 57.9%, whereas the combination of TF and CT imaging achieved an accuracy of 83.3%, a sensitivity of 86.2%, and a specificity of 78.9%. Conclusions: 3D TA of CE-CT images is potentially useful to identify nodal residual disease in HL, with a performance comparable to that of classical CT parameters. Best results are achieved when TA and classical CT features are combined.

60 APPLIED LIFE SCIENCES↗

Simultaneous image reproduction on CRT screen: Moves ultrasonic sectional view and electrocardiogram curves

A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.

Source record↗

Observations of Interplanetary Dust by the Juno Magnetometer Investigation

One of the Juno magnetometer investigation's star cameras was configured to search for unidentified objects during Juno's transit en route to Jupiter. This camera detects and registers luminous objects to magnitude 8. Objects persisting in more than five consecutive images and moving with an apparent angular rate of between 2 and 18,000 arcsec/s were recorded. Among the objects detected were a small group of objects tracked briefly in close proximity to the spacecraft. The trajectory of these objects demonstrates that they originated on the Juno spacecraft, evidently excavated by micrometeoroid impacts on the solar arrays. The majority of detections occurred just prior to and shortly after Juno's transit of the asteroid belt. This rather novel detection technique utilizes the Juno spacecraft's prodigious 60 sq. m of solar array as a dust detector and provides valuable information on the distribution and motion of interplanetary (greater than a micron) dust. Plain Language Summary: The Juno magnetometer investigation uses star cameras co-located with the magnetic sensors at the outer end of one of Juno's solar arrays. These cameras compare images with an onboard star catalog to determine the orientation of the sensors in inertial space. They also serendipitously recorded multiple images of small particles excavated from the spacecraft by high-velocity dust impacts. We trace their trajectories back in time to demonstrate that they evolved from the spacecraft. This allows us to use the vast collecting area of Juno's solar arrays (60 sq. m)as a novel dust detector, sensitive to particles with a mass range never before measured in situ.

Jupiter↗

The Essentials of Parathyroid Hormone Venous Sampling

Hyperparathyroidism is an excess of parathyroid hormone in the blood due to over-activity of one or more parathyroid gland. Localization of abnormal glands with noninvasive imaging modalities, such as technetium sestamibi scan and cross-sectional imaging, has a high success rate. Parathyroid venous sampling is performed for patients with persistent or recurrent disease after previous parathyroid surgery, when repeat noninvasive imaging studies are negative or discordant. The success of invasive localization studies and results interpretation is dependent on the interventional radiologist’s understanding of the normal and ectopic anatomic locations of parathyroid glands, as well as their blood supply and venous drainage. Anatomic and technical considerations for selective parathyroid venous sampling are reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Individual Barium Atoms in Solid Xenon for Barium Tagging in nEXO

The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or “tagging”, of the 136Ba daughter atom from double beta decay of 136Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for ~30 s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of =0.16%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.

Chambers, C↗

Hubble space telescope imaging of decoupled dust clouds in the ram pressure stripped Virgo spirals NGC 4402 and NGC 4522

We present the highest-resolution study to date of the interstellar medium (ISM) in galaxies undergoing ram pressure stripping, using Hubble Space Telescope BVI imaging of NGC 4522 and NGC 4402, Virgo Cluster spirals that are well known to be experiencing intracluster medium (ICM) ram pressure. We find that throughout most of both galaxies, the main dust lane has a fairly well-defined edge, with a population of giant molecular cloud (GMC) sized (tens- to hundreds-of-pc scale), isolated, highly extincting dust clouds located up to ∼1.5 kpc radially beyond it. Outside of these dense clouds, the area has little or no diffuse dust extinction, indicating that the clouds have decoupled from the lower-density ISM material that has already been stripped. Several of the dust clouds have elongated morphologies that indicate active ram pressure, including two large (kpc scale) filaments in NGC 4402 that are elongated in the projected ICM wind direction. We calculate a lower limit on the H I + H{sub 2} masses of these clouds based on their dust extinctions and find that a correction factor of ∼10 gives cloud masses consistent with those measured in CO for clouds of similar diameters, probably due to the complicating factors of foreground light, cloud substructure, and resolution limitations. Assuming that the clouds' actual masses are consistent with those of GMCs of similar diameters (∼10{sup 4}-10{sup 5} M {sub ☉}), we estimate that only a small fraction (∼1%-10%) of the original H I + H{sub 2} remains in the parts of the disks with decoupled clouds. Based on Hα images, a similar fraction of star formation persists in these regions, 2%-3% of the estimated pre-stripping star formation rate. We find that the decoupled cloud lifetimes may be up to 150-200 Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

Expansion dynamics of ultrafast laser produced plasmas in the presence of ambient argon

In this paper, we report the emission features of fs laser ablated brass plasma plumes at various Ar background pressure levels ranging from vacuum to atmospheric conditions. Spectrally integrated 2D-imaging of plasma self-emission showed several interesting features at various pressure levels which consists of plume morphological changes, increase in persistence, confinement, and internal structures. Spatially resolved wavelength dispersed images of the plume were recorded for characterizing the spectral features at various pressure levels and also used for obtaining spatial distribution of Cu I and Zn I species in the plume, signal to noise ratios and fundamental parameters of the plasma; viz. temperature and density. The spatial evolution of excitation temperature and density showed significant changes at various ambient pressure levels and these results were correlated to morphological changes seen in the plume images. Optimum signal to background ratios for emission lines were observed in the moderate pressure range (~ 1-10 Torr). Optical time-of-flight profiles were used to study time evolution of various species in the plume and noticed oscillations at intermediate pressure levels. Possible mechanisms for observed changes in plume shape, optical emission intensity, and dual peak structures in time-of-flight profiles were discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗