Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase contrast.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Very energetic gamma-rays from the June 3, 1982 solar flare

The Gamma-Ray Spectrometer on the SMM satellite has recorded high-energy gamma-ray and neutron emission from the flare on June 3, 1982. During the 65-s impulsive phase the gamma rays above 10 MeV contain emissions from both primary electron bremsstrahlung and nuclear pion decay. Hence the impulsive phase acceleration process must produce both primary electrons with energies above 60 MeV and ions above 500 MeV. This flare also has a extended emission phase lasting more than 1000 s which is most easily observed at gamma-ray energies above 10 MeV. After removing the counting rates from the more slowly moving neutrons produced at earlier times, the resulting gamma ray spectrum can be entirely explained by nuclear pion production. Over 70 percent of the pions were produced in the extended emission phase. In contrast, more than 70 percent of the high-energy primary electron bremsstrahlung and the nuclear line emission produced by ions below 30 MeV occurred in the 65-s impulsive phase. This represents the first clear observation of a new acceleration process which produces an electron-deficient, very hard ion spectrum extending beyond 1000 MeV.

Forrest, D. J.↗

Iterative-Transform Phase Retrieval Using Adaptive Diversity

A phase-diverse iterative-transform phase-retrieval algorithm enables high spatial-frequency, high-dynamic-range, image-based wavefront sensing. [The terms phase-diverse, phase retrieval, image-based, and wavefront sensing are defined in the first of the two immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] As described below, no prior phase-retrieval algorithm has offered both high dynamic range and the capability to recover high spatial-frequency components. Each of the previously developed image-based phase-retrieval techniques can be classified into one of two categories: iterative transform or parametric. Among the modifications of the original iterative-transform approach has been the introduction of a defocus diversity function (also defined in the cited companion article). Modifications of the original parametric approach have included minimizing alternative objective functions as well as implementing a variety of nonlinear optimization methods. The iterative-transform approach offers the advantage of ability to recover low, middle, and high spatial frequencies, but has disadvantage of having a limited dynamic range to one wavelength or less. In contrast, parametric phase retrieval offers the advantage of high dynamic range, but is poorly suited for recovering higher spatial frequency aberrations. The present phase-diverse iterative transform phase-retrieval algorithm offers both the high-spatial-frequency capability of the iterative-transform approach and the high dynamic range of parametric phase-recovery techniques. In implementation, this is a focus-diverse iterative-transform phaseretrieval algorithm that incorporates an adaptive diversity function, which makes it possible to avoid phase unwrapping while preserving high-spatial-frequency recovery. The algorithm includes an inner and an outer loop (see figure). An initial estimate of phase is used to start the algorithm on the inner loop, wherein multiple intensity images are processed, each using a different defocus value. The processing is done by an iterative-transform method, yielding individual phase estimates corresponding to each image of the defocus-diversity data set. These individual phase estimates are combined in a weighted average to form a new phase estimate, which serves as the initial phase estimate for either the next iteration of the iterative-transform method or, if the maximum number of iterations has been reached, for the next several steps, which constitute the outerloop portion of the algorithm. The details of the next several steps must be omitted here for the sake of brevity. The overall effect of these steps is to adaptively update the diversity defocus values according to recovery of global defocus in the phase estimate. Aberration recovery varies with differing amounts as the amount of diversity defocus is updated in each image; thus, feedback is incorporated into the recovery process. This process is iterated until the global defocus error is driven to zero during the recovery process. The amplitude of aberration may far exceed one wavelength after completion of the inner-loop portion of the algorithm, and the classical iterative transform method does not, by itself, enable recovery of multi-wavelength aberrations. Hence, in the absence of a means of off-loading the multi-wavelength portion of the aberration, the algorithm would produce a wrapped phase map. However, a special aberration-fitting procedure can be applied to the wrapped phase data to transfer at least some portion of the multi-wavelength aberration to the diversity function, wherein the data are treated as known phase values. In this way, a multiwavelength aberration can be recovered incrementally by successively applying the aberration-fitting procedure to intermediate wrapped phase maps. During recovery, as more of the aberration is transferred to the diversity function following successive iterations around the ter loop, the estimated phase ceases to wrap in places where the aberration values become incorporated as part of the diversity function. As a result, as the aberration content is transferred to the diversity function, the phase estimate resembles that of a reference flat.

Dean, Bruce H.↗

Nondestructive Evaluation of Advanced Materials with X-ray Phase Mapping

X-ray radiation has been widely used for imaging applications since Rontgen first discovered X-rays over a century ago. Its large penetration depth makes it ideal for the nondestructive visualization of the internal structure and/or defects of materials unobtainable otherwise. Currently used nondestructive evaluation (NDE) tools, X-ray radiography and tomography, are absorption-based, and work well in heavy-element materials where density or composition variations due to internal structure or defects are high enough to produce appreciable absorption contrast. However, in many cases where materials are light-weight and/or composites that have similar mass absorption coefficients, the conventional absorption-based X-ray methods for NDE become less useful. Indeed, the light-weight and ultra-high-strength requirements for the most advanced materials used or developed for current flight mission and future space exploration pose a great challenge to the standard NDE tools in that the absorption contrast arising from the internal structure of these materials is often too weak to be resolved. In this presentation, a solution to the problem, the use of phase information of X-rays for phase contrast X-ray imaging, will be discussed, along with a comparison between the absorption-based and phase-contrast imaging methods. Latest results on phase contrast X-ray imaging of lightweight Space Shuttle foam in 2D and 3D will be presented, demonstrating new opportunities to solve the challenging issues encountered in advanced materials development and processing.

Hu, Zhengwei↗

The evolutionary status of the stellar population in the rho Ophiuchi cloud core

This contribution reports the results of an infrared imaging survey aimed at characterizing the stellar populations associated with the three densest star-forming cores in the Ophiuchus molecular cloud complex. The survey has sufficient sensitivity at J, H, and K (at 5 sigma limits of 16.5, 15.4, and 14.2) to provide a complete census of embedded young stellar objects (YSOs) with masses greater than the hydrogen-burning limit, provided that their ages are less than 3 Myr and that they are obscured by no more than approximately 18 mag of visual extinction. Our data suggest (1) a large fraction (greater than 70%) of the sources located within the cores are still surrounded by circumstellar disks and/or envelopes; and (2) the shape of the initial mass function for masses, M less than 1 solar mass, appears to be consistent with that derived from the solar neighborhood. We also report the results of a deeper imaging survey of centimeter continuum sources (14 sources) in these star-forming cores and in the larger Ophiuchus complex (eight sources). A large fraction (11/14) of the radio sources associated with the cores appear to have infrared excesses diagnostic of circumstellar accretion disks and/or infalling circumstellar envelopes. In these cases, the centimeter continuum radiation most likely diagnoses the ionized component of energetic winds or jets which characterizes YSOs during the disk accretion phase. By contrast, of the eight radio sources located outside dense cores, only two show infrared excesses.

Strom, Karen M.↗

Excess chemical potential of small solutes across water--membrane and water--hexane interfaces

The excess chemical potentials of five small, structurally related solutes, CH4, CH3F, CH2F2, CHF3, and CF4, across the water-glycerol 1-monooleate bilayer and water-hexane interfaces were calculated at 300, 310, and 340 K using the particle insertion method. The excess chemical potentials of nonpolar molecules (CH4 and CF4) decrease monotonically or nearly monotonically from water to a nonpolar phase. In contrast, for molecules that possess permanent dipole moments (CH3F, CH2F, and CHF3), the excess chemical potentials exhibit an interfacial minimum that arises from superposition of two monotonically and oppositely changing contributions: electrostatic and nonelectrostatic. The nonelectrostatic term, dominated by the reversible work of creating a cavity that accommodates the solute, decreases, whereas the electrostatic term increases across the interface from water to the membrane interior. In water, the dependence of this term on the dipole moment is accurately described by second order perturbation theory. To achieve the same accuracy at the interface, third order terms must also be included. In the interfacial region, the molecular structure of the solvent influences both the excess chemical potential and solute orientations. The excess chemical potential across the interface increases with temperature, but this effect is rather small. Our analysis indicates that a broad range of small, moderately polar molecules should be surface active at the water-membrane and water-oil interfaces. The biological and medical significance of this result, especially in relation to the mechanism of anesthetic action, is discussed.

NASA Center ARC↗

Colour thresholding and objective quantification in bioimaging

Computer imaging is rapidly becoming an indispensable tool for the quantification of variables in research and medicine. Whilst its use in medicine has largely been limited to qualitative observations, imaging in applied basic sciences, medical research and biotechnology demands objective quantification of the variables in question. In black and white densitometry (0-256 levels of intensity) the separation of subtle differences between closely related hues from stains is sometimes very difficult. True-colour and real-time video microscopy analysis offer choices not previously available with monochrome systems. In this paper we demonstrate the usefulness of colour thresholding, which has so far proven indispensable for proper objective quantification of the products of histochemical reactions and/or subtle differences in tissue and cells. In addition, we provide interested, but untrained readers with basic information that may assist decisions regarding the most suitable set-up for a project under consideration. Data from projects in progress at Tulane are shown to illustrate the advantage of colour thresholding over monochrome densitometry and for objective quantification of subtle colour differences between experimental and control samples.

NASA Discipline Neuroscience↗

Epstein-Barr virus shedding by astronauts during space flight

Patterns of Epstein-Barr virus (EBV) reactivation in 32 astronauts and 18 healthy age-matched control subjects were characterized by quantifying EBV shedding. Saliva samples were collected from astronauts before, during, and after 10 space shuttle missions of 5-14 days duration. At one time point or another, EBV was detected in saliva from each of the astronauts. Of 1398 saliva specimens from 32 astronauts, polymerase chain reaction analysis showed that 314 (23%) were positive for EBV DNA. Examination by flight phase showed that 29% of the saliva specimens collected from 28 astronauts before flight were positive for EBV DNA, as were 16% of those collected from 25 astronauts during flight and 16% of those collected after flight from 23 astronauts. The mean number of EBV copies from samples taken during the flights was 417 per mL, significantly greater (p<.05) than the number of viral copies from the preflight (40) and postflight (44) phases. In contrast, the control subjects shed EBV DNA with a frequency of 3.7% and mean number of EBV copies of 40 per mL of saliva. Ten days before flight and on landing day, titers of antibody to EBV viral capsid antigen were significantly (p<.05) greater than baseline levels. On landing day, urinary levels of cortisol and catecholamines were greater than their preflight values. In a limited study (n=5), plasma levels of substance P and other neuropeptides were also greater on landing day. Increases in the number of viral copies and in the amount of EBV-specific antibody were consistent with EBV reactivation before, during, and after space flight.

Randomized Controlled Trial↗

Spacecraft Environment May Reduce Resistance To Infection

Living and working in a spacecraft exposes the crew to a unique environment. This environment includes microgravity, increased radiation, chemical and biological contamination, and a variety of stressors. Disturbances in this balance are often manifested by diminished immunity in astronauts/cosmonauts. Reactivation of Epstein- Barr virus (EBV), cytomegalovirus (CMV), and varicella-zoster virus (VZV) has been used as an indicator of immune status. Reactivation of EBV and VZV were detected and quantified in saliva. CMV was measured in urine. The DNA was extracted using a Qiagen Inc. kit and viral DNA was detected by real time polymerase chain reaction (PCR) based assay with Taqman 7700 (PE Biosystems). Patterns of Epstein-Barr virus (EBV) reactivation in 32 astronauts and 18 healthy age-matched control subjects were characterized by quantifying EBV shedding. Saliva samples were collected before, during, and after 10 space shuttle missions of 5 to 14 d duration. Of 1398 saliva specimens from 32 astronauts, 314 (23%) were positive for EBV DNA. Examination by flight phase showed that 29% of the saliva specimens collected from 28 astronauts before flight were positive for EBV DNA, as were 16% of those collected from 25 astronauts during flight and 16% of those collected after flight from 23 astronauts. The mean number of EBV copies/mL from samples taken during the flights was 417, ten-fold greater (p < 0.05) than the copies from the preflight (40) and post flight (44) phases. In contrast, the control subjects shed EBV DNA with a frequency of 3.7% and mean EBV copies of 40 per mL of saliva. Ten days before flight and on landing day, titers of antibody to EBV viral capsid antigen were significantly (p < 0.05) greater than baseline levels. Increases in the number of viral copies and in the amount of EBV-specific antibody were consistent with EBV reactivation before, during, and after space flight. Similarly, CMV and VZV reactivation increased in response to space flight conditions. Data indicates that space flight is a unique stress environment that may produce stress-induced changes in the host-microbe relationship resulting in increased risk of infection.

Pierson, Duane L.↗

Epstein-Barr Virus Shedding by Astronauts During Space Flight

Patterns of Epstein-Barr virus (EBV) reactivation in 32 astronauts and 18 healthy age-matched control subjects were characterized by quantifying EBV shedding. Saliva samples were collected from astronauts before, during, and after 10 space shuttle missions of 5 to 14 d duration. Samples were collected on a similar schedule from control subjects. At one time point or another, EBV was detected in saliva from each of the astronauts. Of 1398 saliva specimens from 32 astronauts, polymerase chain reaction analysis showed that 314 (23%) were positive for EBV DNA. Examination by flight phase showed that 29% of the saliva specimens collected before flight were positive for EBV DNA, as were 16% of those collected during flight and 16% of those collected after flight. The mean number of copies of EBV DNA from samples taken during the flights was 417 plus or minus 31, significantly greater (p less than 0.05) than the number of copies from the preflight (40 plus or minus 2) and postflight (44 plus or minus 5) phases. In contrast, the control subjects shed EBV DNA with a frequency of 3.7% and a mean number of EBV DNA copies of 40 plus or minus 2 per mL of saliva. Ten days before flight and on landing day, titers of antibody to EBV viral capsid antigen were significantly (p less than 0.05) greater than baseline levels. On landing day, urinary levels of cortisol and catecholamines, and plasma levels of substance P and other neuropeptides, were increased over their preflight values. Increases in the number of viral copies and in the amount of EBV-specific antibody were consistent with the occurrence of EBV reactivation before, during, and after space flight.

Pierson, D. L.↗

Approximations of distant retrograde orbits for mission design

Distant retrograde orbits (DROs) are stable periodic orbit solutions of the equations of motion in the circular restricted three body problem. Since no closed form expressions for DROs are known, we present methods for approximating a family of planar DROs for an arbitrary, fixed mass ratio. Furthermore we give methods for computing the first and second derivatives of the position and velocity with respect to the variables that parameterize the family. The approximation and derivative methods described allow a mission designer to target specific DROs or a range of DROs with no regard to phasing in contrast to the more limited case of targeting a six-state only.

Distant Retrograde Orbits (DRO)↗

From a Sounding Rocket per Year to an Observatory per Lifetime

When I began my career as an X-ray astronomer/astrophysicist we launched new experiments at a cadence of approximately one per year. The majority of each these projects involved a newly developed instrument, revolutionary for its time. Then, innovation in instrument development could proceed in parallel with friendly competition amongst a number of groups. Thus, I was privileged to help develop and fly X-ray concentrators and telescopes, crystal spectrometers, and two types of X ]ray polarimeters. I have also been privileged to play a central role in design, development, calibration and operation of the Chandra X ]Ray Observatory. I will contrast these phases of my career both from a historical perspective and for the lessons I would pass on for the future.

Weisskopf, Martin C.↗

Zernike Wavefront Sensor (ZWFS) Development for Low Order Wavefront Sensing (LOWFS)

ZWFS is known to be photon noise optimal for measuring low order aberrations. Recently, ZWFS was selected as the baseline LOWFS technology on WFIRST for its sensitivity, accuracy, and its ease of integration with the starlight rejection mask. In this paper, we present the development of ZWFS sensor, including the algorithm description, sensitivity analysis, and some early experimental model validation results from a fabricated ZWFS phase mask on a stand-alone LOWFS testbed.

Zernike phase contrast↗

Convergent properties of vestibular-related brain stem neurons in the gerbil

Three classes of vestibular-related neurons were found in and near the prepositus and medial vestibular nuclei of alert or decerebrate gerbils, those responding to: horizontal translational motion, horizontal head rotation, or both. Their distribution ratios were 1:2:2, respectively. Many cells responsive to translational motion exhibited spatiotemporal characteristics with both response gain and phase varying as a function of the stimulus vector angle. Rotationally sensitive neurons were distributed as Type I, II, or III responses (sensitive to ipsilateral, contralateral, or both directions, respectively) in the ratios of 4:6:1. Four tested factors shaped the response dynamics of the sampled neurons: canal-otolith convergence, oculomotor-related activity, rotational Type (I or II), and the phase of the maximum response. Type I nonconvergent cells displayed increasing gains with increasing rotational stimulus frequency (0.1-2.0 Hz, 60 degrees /s), whereas Type II neurons with convergent inputs had response gains that markedly decreased with increasing translational stimulus frequency (0.25-2.0 Hz, +/-0.1 g). Type I convergent and Type II nonconvergent neurons exhibited essentially flat gains across the stimulus frequency range. Oculomotor-related activity was noted in 30% of the cells across all functional types, appearing as burst/pause discharge patterns related to the fast phase of nystagmus during head rotation. Oculomotor-related activity was correlated with enhanced dynamic range compared with the same category that had no oculomotor-related response. Finally, responses that were in-phase with head velocity during rotation exhibited greater gains with stimulus frequency increments than neurons with out-of-phase responses. In contrast, for translational motion, neurons out of phase with head acceleration exhibited low-pass characteristics, whereas in-phase neurons did not. Data from decerebrate preparations revealed that although similar response types could be detected, the sampled cells generally had lower background discharge rates, on average one-third lower response gains, and convergent properties that differed from those found in the alert animals. On the basis of the dynamic response of identified cell types, we propose a pair of models in which inhibitory input from vestibular-related neurons converges on oculomotor neurons with excitatory inputs from the vestibular nuclei. Simple signal convergence and combinations of different types of vestibular labyrinth information can enrich the dynamic characteristics of the rotational and translational vestibuloocular responses.

Non-NASA Center↗