Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase frequency detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

68 records · Page 4

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Binary neutron star mergers as a probe of quark-hadron crossover equations of state

It is anticipated that the gravitational radiation detected in future gravitational wave (GW) detectors from binary neutron star (NS) mergers can probe the high-density equation of state (EOS). In this work, we perform the first simulations of binary NS mergers which adopt various parametrizations of the quark-hadron crossover (QHC) EOS. These are constructed from combinations of a hadronic EOS ($n_b$<2 $n_0$) and a quark-matter EOS ($n_b$>5 $n_0$), where $n_b$ and $n_0$ are the baryon number density and the nuclear saturation density, respectively. At the crossover densities (2 $n_0$ < $n_b$ < 5 $n_0$) the QHC EOSs continuously soften, while remaining stiffer than hadronic and first-order phase transition EOSs, achieving the stiffness of strongly correlated quark matter. This enhanced stiffness leads to significantly longer lifetimes of the postmerger NS than that for a pure hadronic EOS. We find a dual nature of these EOSs such that their maximum chirp GW frequencies $f_{\text{max}}$ fall into the category of a soft EOS while the dominant peak frequencies ($f_{\text{peak}}$) of the postmerger stage fall in between that of a soft and stiff hadronic EOS. An observation of this kind of dual nature in the characteristic GW frequencies will provide crucial evidence for the existence of strongly interacting quark matter at the crossover densities for QCD.

79 ASTRONOMY AND ASTROPHYSICS↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗

A microchip microcontroller-based transducer controller for non-contact scanning probe microscopy with phase-locked loop, amplitude, and Q control

An inexpensive yet versatile transducer controller for non-contact scanning probe microscopy (SPM) based on a PIC32 microcontroller from Microchip Technology, Inc is described. In addition to feedback control using the amplitude or phase of the signal from the non-contact transducer, the controller includes a phase-locked loop for frequency-shift feedback, as well as fixed-amplitude, quality factor (Q) control, and self-excitation modes. Apart from the input amplifiers, output buffers, and the Q-control circuit, all other functions of the controller are instantiated in software on the microchip, enabling rapid changes in operating parameters if needed. The controller communicates with a host personal computer via a simple serial connection. The controller has been tested with a quartz tuning-fork transducer but can be used with any oscillating non-contact transducer.

47 OTHER INSTRUMENTATION↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Large magnetoresistance and quantum oscillations observed in superconducting β -IrSn 4

Diverse quantum phenomena have been observed in TSn 4 transition metal (T) stannides, including superconductivity, nontrivial topology, and large magnetoresistance (MR) at low temperatures. Here, we report the experimental and theoretical investigation of tetragonal β-IrSn 4 (space group I 4 1 /acd) with the lattice parameters a = 6.362(3) Å and c = 22.723(0) Å. The temperature dependence of the electrical resistivity indicates that β-IrSn 4 is a good metal with Fermi-liquid behavior above the superconducting transition at T c ∼ 0.7 K. Magnetic susceptibility measurements indicate it is non-magnetic. However, positive transverse MR with linear field dependence is observed. At T= 2 K and Μ 0 H = 14 T, the MR reaches 700% without sign of saturation. Shubnikov–de Haas oscillations are observed from proximity detector oscillator measurements up to 60 T. We experimentally extract several frequencies, and through comparison to first-principles calculations, identify corresponding electronic bands. For H // c, two strong oscillations, F 1 ≈ 109 and F 2 ≈ 302 T, allow us to determine effective masses 0.266m 0 and 0.300m 0 (m 0 is the free-electron mass), respectively. The topology of these bands is discussed.

36 MATERIALS SCIENCE↗

A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beehive haloscope for high-mass axion dark matter

We propose a new haloscope geometry that can arbitrarily increase the resonator volume for a given target axion mass. This geometry consists of closely packed, overlapping coaxial cavities operating as a single resonator. While the resonant frequency is still determined by the dimensions of the individual “cells,” the strong interactions between the cells encourage the entire “beehive” to oscillate in phase, a phenomenon expected of tightly coupled harmonic oscillators. This synchronization behavior allows the construction of a singly connected large volume resonator at high frequency by simply increasing the number of the cells. Using direct numerical simulations, we verify the existence of a global eigenmode that has a high (40%) form factor in a 169-element beehive resonator. The resonant frequency of the eigenmode is tunable by moving the center rods laterally in unison. The form factor is very tolerant to dimensional deviations and misalignment as a result of mode hybridization due to strong coupling. The beehive haloscope inherits many appealing properties from the conventional coaxial cavity: a high quality factor, compatibility with a solenoid magnet, and ease of fabrication, tuning, and coupling. We argue that this geometry is an excellent candidate for high-mass axion searches covering the post-inflationary parameter space (>5 GHz).

47 OTHER INSTRUMENTATION↗

Project 8 apparatus for cyclotron radiation emission spectroscopy with 83m Kr and tritium

Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project 8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection of the CRES signal from the conversion electrons of 83m Kr and the first CRES measurement of the beta-decay spectrum of molecular tritium.

Neutrino detectors↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

D-Egg: a dual PMT optical module for IceCube

The D-Egg, an acronym for "Dual optical sensors in an Ellipsoid Glass for Gen2," is one of the optical modules designed for future extensions of the IceCube experiment at the South Pole. The D-Egg has an elongated-sphere shape to maximize the photon-sensitive effective area while maintaining a narrow diameter to reduce the cost and the time needed for drilling of the deployment holes in the glacial ice for the optical modules at depths up to 2700 m. The D-Egg design is utilized for the IceCube Upgrade, the next stage of the IceCube project also known as IceCube-Gen2 Phase 1, where nearly half of the optical sensors to be deployed are D-Eggs. With two 8-inch high-quantum efficiency photomultiplier tubes (PMTs) per module, D-Eggs offer an increased effective area while retaining the successful design of the IceCube digital optical module (DOM). The convolution of the wavelength-dependent effective area and the Cherenkov emission spectrum provides an effective photodetection sensitivity that is 2.8 times larger than that of IceCube DOMs. The signal of each of the two PMTs is digitized using ultra-low-power 14-bit analog-to-digital converters with a sampling frequency of 240 MSPS, enabling a flexible event triggering, as well as seamless and lossless event recording of single-photon signals to multi-photons exceeding 200 photoelectrons within 10 ns. Mass production of D-Eggs has been completed, with 277 out of the 310 D-Eggs produced to be used in the IceCube Upgrade. In this paper, we report the design of the D-Eggs, as well as the sensitivity and the single to multi-photon detection performance of mass-produced D-Eggs measured in a laboratory using the built-in data acquisition system in each D-Egg optical sensor module.

47 OTHER INSTRUMENTATION↗