Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase space methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Grassmann phase space theory and the Jaynes–Cummings model

The Jaynes–Cummings model of a two-level atom in a single mode cavity is of fundamental importance both in quantum optics and in quantum physics generally, involving the interaction of two simple quantum systems—one fermionic system (the TLA), the other bosonic (the cavity mode). Depending on the initial conditions a variety of interesting effects occur, ranging from ongoing oscillations of the atomic population difference at the Rabi frequency when the atom is excited and the cavity is in an n-photon Fock state, to collapses and revivals of these oscillations starting with the atom unexcited and the cavity mode in a coherent state. The observation of revivals for Rydberg atoms in a high-Q microwave cavity is key experimental evidence for quantisation of the EM field. Theoretical treatments of the Jaynes–Cummings model based on expanding the state vector in terms of products of atomic and n-photon states and deriving coupled equations for the amplitudes are a well-known and simple method for determining the effects. In quantum optics however, the behaviour of the bosonic quantum EM field is often treated using phase space methods, where the bosonic mode annihilation and creation operators are represented by c-number phase space variables, with the density operator represented by a distribution function of these variables. Fokker–Planck equations for the distribution function are obtained, and either used directly to determine quantities of experimental interest or used to develop c-number Langevin equations for stochastic versions of the phase space variables from which experimental quantities are obtained as stochastic averages. Phase space methods have also been developed to include atomic systems, with the atomic spin operators being represented by c-number phase space variables, and distribution functions involving these variables and those for any bosonic modes being shown to satisfy Fokker–Planck equations from which c-number Langevin equations are often developed. However, atomic spin operators satisfy the standard angular momentum commutation rules rather than the commutation rules for bosonic annihilation and creation operators, and are in fact second order combinations of fermionic annihilation and creation operators. Though phase space methods in which the fermionic operators are represented directly by c-number phase space variables have not been successful, the anti-commutation rules for these operators suggest the possibility of using Grassmann variables—which have similar anti-commutation properties. However, in spite of the seminal work by Cahill and Glauber and a few applications, the use of phase space methods in quantum optics to treat fermionic systems by representing fermionic annihilation and creation operators directly by Grassmann phase space variables is rather rare. This paper shows that phase space methods using a positive P type distribution function involving both c-number variables (for the cavity mode) and Grassmann variables (for the TLA) can be used to treat the Jaynes–Cummings model. Although it is a Grassmann function, the distribution function is equivalent to six c-number functions of the two bosonic variables. Experimental quantities are given as bosonic phase space integrals involving the six functions. A Fokker–Planck equation involving both left and right Grassmann differentiations can be obtained for the distribution function, and is equivalent to six coupled equations for the six c-number functions. The approach used involves choosing the canonical form of the (non-unique) positive P distribution function, in which the correspondence rules for the bosonic operators are non-standard and hence the Fokker–Planck equation is also unusual. Initial conditions, such as those above for initially uncorrelated states, are discussed and used to determine the initial distribution function. Transformations to new bosonic variables rotating at the cavity frequency enable the six coupled equations for the new c-number functions–that are also equivalent to the canonical Grassmann distribution function–to be solved analytically, based on an ansatz from an earlier paper by Stenholm. It is then shown that the distribution function is exactly the same as that determined from the well-known solution based on coupled amplitude equations. In quantum–atom optics theories for many atom bosonic and fermionic systems are needed. With large atom numbers, treatments must often take into account many quantum modes—especially for fermions. Generalisations of phase space distribution functions of phase space variables for a few modes to phase space distribution functionals of field functions (which represent the field operators, c-number fields for bosons, Grassmann fields for fermions) are now being developed for large systems. For the fermionic case, the treatment of the simple two mode problem represented by the Jaynes–Cummings model is a useful test case for the future development of phase space Grassmann distribution functional methods for fermionic applications in quantum–atom optics. -- Highlights: •Novel phase space theory of the Jaynes–Cummings model using Grassmann variables. •Fokker–Planck equations solved analytically. •Results agree with the standard quantum optics treatment. •Grassmann phase space theory applicable to fermion many-body problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of barrier voltages in cyclic accelerators

Principle of operation of barrier RF voltage systems that are used for stacking and acceleration of charged particles in proton synchrotrons and storage rings is presented. The description is based on two sample models of such systems: with rectangular and quasi-sinusoidal barriers. Two different methods are used for description of particle dynamics in synchrotrons with barrier RF voltage. The first method is “stepwise” analysis of particle motion in the “momentum-phase” space. This method allows to give a clear and simple description of physical principles of the method and to obtain its main properties in analytical form. However, this method is not always efficient. Therefore, a method of analysis of phase motion of particles in barrier systems based on solution of differential equations of phase motion is presented in the paper and is widely used in practice. This method allows both analytical calculations and numeric simulation, which is illustrated with the aid of supplied examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generation of Relativistic Electron Bunches with Arbitrary Current Distribution via Transverse-to-Longitudinal Phase Space Exchange

We propose a general method for tailoring the current distribution of relativistic electron bunches. The technique relies on a recently proposed method to exchange the longitudinal phase space emittance with one of the transverse emittances. The method consists of transversely shaping the bunch and then converting its transverse profile into a current profile via a transverse-to-longitudinal phase-space-exchange beamline. We show that it is possible to tailor the current profile to follow, in principle, any desired distributions. We demonstrate, via computer simulations, the application of the method to generate trains of microbunches with tunable spacing and linearly-ramped current profiles. We also briefly explore potential applications of the technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

W{sup +}W{sup -} production in large extra dimension model at next-to-leading order in QCD at the LHC

We present next-to-leading order QCD corrections to production of two W bosons in hadronic collisions in the extra dimension Arkani-Hamed, Dimopoulos, and Dvali model. Invariant mass and rapidity distributions are obtained to order {alpha}{sub s} in QCD by taking into account all the parton level subprocesses. The computation is organized using the Monte Carlo based method of phase space slicing. We estimate the impact of the QCD corrections on various observables and find that they are significant. We present some results for a 10 TeV LHC, but most of the results presented here are for 14 TeV LHC. We also show the reduction in factorization scale uncertainty when O({alpha}{sub s}) effects are included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations

Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian TrueBeam treatment head geometry imported from cad (computer aided design) without adjusting the input electron phase space parameters. Methods: geant4 v4.9.2.p01 was employed to simulate the 6 MV beam treatment head geometry of the Varian TrueBeam linac. The electron tracks in the linear accelerator were simulated with Parmela, and the obtained electron phase space was used as an input to the Monte Carlo beam transport and dose calculations. The geometry components are tessellated solids included in geant4 as gdml (generalized dynamic markup language) files obtained via STEP (standard for the exchange of product) export from Pro/Engineering, followed by STEP import in Fastrad, a STEP-gdml converter. The linac has a compact treatment head and the small space between the shielding collimator and the divergent arc of the upper jaws forbids the implementation of a plane for storing the phase space. Instead, an IAEA (International Atomic Energy Agency) compliant phase space writer was implemented on a cylindrical surface. The simulation was run in parallel on a 1200 node Linux cluster. The 6 MV dose calculations were performed for field sizes varying from 4 x 4 to 40 x 40 cm{sup 2}. The voxel size for the 60x60x40 cm{sup 3} water phantom was 4x4x4 mm{sup 3}. For the 10x10 cm{sup 2} field, surface buildup calculations were performed using 4x4x2 mm{sup 3} voxels within 20 mm of the surface. Results: For the depth dose curves, 98% of the calculated data points agree within 2% with the experimental measurements for depths between 2 and 40 cm. For depths between 5 and 30 cm, agreement within 1% is obtained for 99% (4x4), 95% (10x10), 94% (20x20 and 30x30), and 89% (40x40) of the data points, respectively. In the buildup region, the agreement is within 2%, except at 1 mm depth where the deviation is 5% for the 10x10 cm{sup 2} open field. For the lateral dose profiles, within the field size for fields up to 30x30 cm{sup 2}, the agreement is within 2% for depths up to 10 cm. At 20 cm depth, the in-field maximum dose difference for the 30x30 cm{sup 2} open field is within 4%, while the smaller field sizes agree within 2%. Outside the field size, agreement within 1% of the maximum dose difference is obtained for all fields. The calculated output factors varied from 0.938{+-}0.015 for the 4x4 cm{sup 2} field to 1.088{+-}0.024 for the 40x40 cm{sup 2} field. Their agreement with the experimental output factors is within 1%. Conclusions: The authors have validated a geant4 simulated IAEA-compliant phase space of the TrueBeam linac for the 6 MV beam obtained using a high accuracy geometry implementation from cad. These files are publicly available and can be used for further research.

43 PARTICLE ACCELERATORS↗

Physics-constrained superresolution diffusion for six-dimensional phase space diagnostics

Adaptive physics-constrained superresolution diffusion is developed for noninvasive virtual diagnostics of the six-dimensional (6D) phase space density of charged particle beams. An adaptive variational autoencoder embeds initial beam condition images and scalar measurements to a low-dimensional latent space from which a 32 6 pixel 6D tensor representation of the beam's 6D phase space density is generated. Projecting from a 6D tensor generates physically consistent two-dimensional projections. Physics-guided superresolution diffusion transforms low-resolution images of the 6D density to high resolution 256 × 256 pixel images. Unsupervised adaptive latent space tuning enables tracking of time-varying beams without knowledge of time-varying initial conditions. The method is demonstrated with experimental data and multiparticle simulations at the HiRES UED. The general approach is applicable to a wide range of complex dynamic systems evolving in high-dimensional phase space. The method is shown to be robust to distribution shift without retraining. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

A Versatile and Accurate Method for Halo Mass Determination from Phase-space Distribution of Satellite Galaxies

We propose a versatile and accurate method to estimate the halo mass and concentration from the kinematics of satellite galaxies. We construct the 6D phase-space distribution function of satellites from a cosmological simulation based on the similarity of internal dynamics for different halos. Within the Bayesian statistical framework, not only can we efficiently infer the halo mass and concentration, we can also treat various observational effects, including the selection function, incomplete data, and measurement errors, in a rigorous and straightforward manner. Through tests with mock samples, we show that our method is valid and accurate, as well as more precise than pure steady-state methods. It can constrain the halo mass to within ~20% using only 20 tracers and has a small intrinsic uncertainty of ~10%. In addition to the clear application to the Milky Way and similar galaxies, our method can be extended to galaxy groups or clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo calculation of monitor unit for electron arc therapy

Purpose: Monitor unit (MU) calculations for electron arc therapy were carried out using Monte Carlo simulations and verified by measurements. Variations in the dwell factor (DF), source-to-surface distance (SSD), and treatment arc angle ({alpha}) were studied. Moreover, the possibility of measuring the DF, which requires gantry rotation, using a solid water rectangular, instead of cylindrical, phantom was investigated. Methods: A phase space file based on the 9 MeV electron beam with rectangular cutout (physical size=2.6x21 cm{sup 2}) attached to the block tray holder of a Varian 21 EX linear accelerator (linac) was generated using the EGSnrc-based Monte Carlo code and verified by measurement. The relative output factor (ROF), SSD offset, and DF, needed in the MU calculation, were determined using measurements and Monte Carlo simulations. An ionization chamber, a radiographic film, a solid water rectangular phantom, and a cylindrical phantom made of polystyrene were used in dosimetry measurements. Results: Percentage deviations of ROF, SSD offset, and DF between measured and Monte Carlo results were 1.2%, 0.18%, and 1.5%, respectively. It was found that the DF decreased with an increase in {alpha}, and such a decrease in DF was more significant in the {alpha} range of 0 deg. - 60 deg. than 60 deg. - 120 deg. Moreover, for a fixed {alpha}, the DF increased with an increase in SSD. Comparing the DF determined using the rectangular and cylindrical phantom through measurements and Monte Carlo simulations, it was found that the DF determined by the rectangular phantom agreed well with that by the cylindrical one within {+-}1.2%. It shows that a simple setup of a solid water rectangular phantom was sufficient to replace the cylindrical phantom using our specific cutout to determine the DF associated with the electron arc. Conclusions: By verifying using dosimetry measurements, Monte Carlo simulations proved to be an alternative way to perform MU calculations effectively for electron arc therapy. Since Monte Carlo simulations can generate a precalculated database of ROF, SSD offset, and DF for the MU calculation, with a reduction in human effort and linac beam-on time, it is recommended that Monte Carlo simulations be partially or completely integrated into the commissioning of electron arc therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Travelling fronts of the CO oxidation on Pd(111) with coverage-dependent diffusion

In this work, we study a surface reaction on Pd(111) crystals under ultra-high-vacuum conditions that can be modeled by two coupled reaction-diffusion equations. In the bistable regime, the reaction exhibits travelling fronts that can be observed experimentally using photo electron emission microscopy. The spatial profile of the fronts reveals a coverage-dependent diffusivity for one of the species. We propose a method to solve the nonlinear eigenvalue problem and compute the direction and the speed of the fronts based on a geometrical construction in phase-space. This method successfully captures the dependence of the speed on control parameters and diffusivities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next-to-leading order corrections to e{sup +}e{sup -{yields}}W{sup +}W{sup -}Z and e{sup +}e{sup -{yields}}ZZZ

We calculate the one-loop electroweak corrections to e{sup +}e{sup -{yields}}W{sup +}W{sup -}Z and e{sup +}e{sup -{yields}}ZZZ and analyze their impacts on both the total cross section and some key distributions. These processes are important for the measurements of the quartic couplings of the massive gauge bosons which can be a window on the mechanism of spontaneous symmetry breaking. We find that even after subtracting the leading QED corrections, the electroweak corrections can still be large, especially as the energy increases. We compare and implement different methods of dealing with potential instabilities in the routines pertaining to the loop integrals. For the real corrections we apply a dipole subtraction formalism and compare it to a phase-space slicing method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-386: A Monte Carlo Dose Calculation Framework for Electron Beams On Varian TrueBeam

Purpose: The design of the linac head is different for TrueBeam than Clinac, and there are differences in measured dose distributions in water phantoms between TrueBeam and Clinac for electron beams. Therefore, MC models for Clinac may not be applied directly to the Truebeam linac. The purpose of this study is to validate a Monte Carlo (MC) dose calculation framework for electron beams on Varian TrueBeam with phase space files provided by Varian. Methods: The particle histories from the phase space file were used as input for the down-stream simulation including jaws, applicators, and water phantom. MC packages BEAMnrc/DOSYXZnrc were used. The down-stream beam components were modeled according to manufacturer specifications and the dose distributions were compared with the measured data of standard cones. The measurements were performed in a water phantom with a p-type electron field diode (diameter 0.2cm) and ion chamber (CC13). Depth dose and orthogonal profiles at depths defined by R{sub 1} {sub 0} {sub 0}, R{sub 5} {sub 0}, Rp were compared. Results: Preliminary results for a 16 MeV phase space and 10x10, 15x15, and 20x20 cm{sup 2} applicator are presented. Simulations were run for a statistical uncertainty of <2% at depth of maximum dose for a voxel resolution of 0.5x0.5x0.2cm{sup 2}. Dose and range differences for the PDD profiles were within 2% and 1 mm, respectively. Dose differences within the central 80% of the beam width for the orthogonal profiles at depth of maximum dose were less than 2% for the 10x10, 15x15, and 20x20 cm{sup 2} applicator, respectively. Conclusion: Varian electron phase space files simulations are in agreement with measured commissioning data. These phase space files can be used in the simulation of TrueBeam linacs, and will provide reproducibility across publications. Analyses for all electron energies and standard applicators are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

Beam dynamics simulations of the transverse-to-longitudinal emittance exchange proof-of-principle experiment at the Argonne Wakefield Accelerator.

Transverse-to-longitudinal emittance exchange has promising applications in various advanced acceleration and light source concepts. A proof-of-principle experiment to demonstrate this phase space manipulation method is currently being planned at the Argonne Wakefield Accelerator. The experiment focuses on exchanging a low longitudinal emittance with a high transverse horizontal emittance and also incorporates room for possible parametric studies e.g. using an incoming flat beam with tunable horizontal emittance. In this paper, we present realistic start-to-end beam dynamics simulation of the scheme, explore the limitations of this phase space exchange.

43 PARTICLE ACCELERATORS↗

Limiting Effects in the Transverse-to-Longitudinal Emittance Exchange Technique for Low Energy Relativistic Electron Beams

Transverse to longitudinal phase space manipulation hold great promises, e.g., as a potential technique for repartitioning the emittances of a beam. A proof-of-principle experiment to demonstrate the exchange of a low longitudinal emittance with a larger transverse emittance is in preparation at the Argonne Wakefield Accelerator using a {approx}12 MeV electron beam. In this paper we explore the limiting effects of this phase space manipulation method including high order and collective effects. A realistic start-to-end simulation of the planned proof-of-principle experiment including sensitivity studies is also presented.

43 PARTICLE ACCELERATORS↗

4D Emittance Measurements Using Multiple Wire and Waist Scan Methods in the ATF Extraction Line

Emittance measurements performed in the diagnostic section of the Accelerator Test Facility (ATF) extraction line since 1998 led to vertical emittances three times larger than the expected ones, with a strong dependence on intensity. An experimental program is pursued to investigate potential sources of emittance growth and find possible remedies. This requires efficient and reliable emittance measurement techniques. In the past, several phase-space reconstruction methods developed at SLAC and KEK have been used to estimate the vertical emittance, based on multiple location beam size measurements and dedicated quadrupole scans. These methods have been shown to be very sensitive to measurement errors and other fluctuations in the beam conditions. In this context new emittance measurements have been performed revisiting these methods and newly developed ones with a systematic approach to compare and characterise their performance in the ATF extraction line.

43 PARTICLE ACCELERATORS↗

MO-FG-CAMPUS-TeP3-03: Calculation of Proton Pencil Beam Properties with Full Beamline Model in TOPAS

Purpose: Introducing Monte Carlo based dose calculation algorithms into proton therapy planning systems (TPS) leads to improved accuracy. However accurate modelling of the proton pencil beam impinging the patient is necessary. Current approaches rely on measurement-driven reconstruction of phase-space and spectrum properties, typically constrained to analytical model functions. In this study a detailed Monte Carlo model of the complete cyclotron-based delivery system was created with the aim of providing more representative beam properties at treatment position. Methods: A model of the Varian Probeam proton system from the cyclotron exit to isocenter was constructed in the TOPAS Monte Carlo framework. The beam evolution through apertures and magnetic elements was validated using Transport/Turtle calculations and additionally against measurements from the Probeam™ system at Scripps Proton Therapy Center (SPTC) in San Diego, CA. A voxelized water phantom at isocenter allowed for comparison of the dose-depth curve from the Probeam model with that of a corresponding Gaussian beam over the entire energy range (70–240 MeV). Measurements of relative beam fluence cross-profiles and depth-dose curves at and around isocenter were also compared to the MC results. Results: The simulated TOPAS beam envelope was found to agree with both the Transport/Turtle and measurements to within 5% for most of the beamline. The MC predicted energy spectrum at isocenter was found to deviate increasingly from Gaussian at energies below 160 MeV. The corresponding effects on the depth dose curve agreed well with measurements. Conclusion: Given the flexibility of TOPAS and available details of the delivery system, an accurate characterization of a proton pencil beam at isocenter is possible. Incorporation of the MC derived properties of the proton pencil beam can eliminate analytical approximations and ultimately increase treatment plan accuracy and quality. Both authors are employees of Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Full Core Power Calculations for Pressurized Water Reactors

We have implemented a new multilevel parallel decomposition in the Denovo discrete ordinates radiation transport code. In concert with Krylov subspace iterative solvers, the multilevel decomposition allows concurrency over energy in addition to space-angle. The original space-angle partitioning in Denovo placed an eective limit on the scalability of the transport solver that was highly dependent on the problem size. The added phase-space concurrency combined with the high-performance Krylov solvers has enabled weak scaling to 100K cores on the Jaguar XT5 supercomputer. Furthermore, the multilevel decomposition provides enough concurrency to scale to exascale computing and beyond.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo simulation of TrueBeam flattening-filter-free beams using Varian phase-space files: Comparison with experimental data

Purpose: Phase-space files for Monte Carlo simulation of the Varian TrueBeam beams have been made available by Varian. The aim of this study is to evaluate the accuracy of the distributed phase-space files for flattening filter free (FFF) beams, against experimental measurements from ten TrueBeam Linacs. Methods: The phase-space files have been used as input in PRIMO, a recently released Monte Carlo program based on thePENELOPE code. Simulations of 6 and 10 MV FFF were computed in a virtual water phantom for field sizes 3 × 3, 6 × 6, and 10 × 10 cm{sup 2} using 1 × 1 × 1 mm{sup 3} voxels and for 20 × 20 and 40 × 40 cm{sup 2} with 2 × 2 × 2 mm{sup 3} voxels. The particles contained in the initial phase-space files were transported downstream to a plane just above the phantom surface, where a subsequent phase-space file was tallied. Particles were transported downstream this second phase-space file to the water phantom. Experimental data consisted of depth doses and profiles at five different depths acquired at SSD = 100 cm (seven datasets) and SSD = 90 cm (three datasets). Simulations and experimental data were compared in terms of dose difference. Gamma analysis was also performed using 1%, 1 mm and 2%, 2 mm criteria of dose-difference and distance-to-agreement, respectively. Additionally, the parameters characterizing the dose profiles of unflattened beams were evaluated for both measurements and simulations. Results: Analysis of depth dose curves showed that dose differences increased with increasing field size and depth; this effect might be partly motivated due to an underestimation of the primary beam energy used to compute the phase-space files. Average dose differences reached 1% for the largest field size. Lateral profiles presented dose differences well within 1% for fields up to 20 × 20 cm{sup 2}, while the discrepancy increased toward 2% in the 40 × 40 cm{sup 2} cases. Gamma analysis resulted in an agreement of 100% when a 2%, 2 mm criterion was used, with the only exception of the 40 × 40 cm{sup 2} field (∼95% agreement). With the more stringent criteria of 1%, 1 mm, the agreement reduced to almost 95% for field sizes up to 10 × 10 cm{sup 2}, worse for larger fields. Unflatness and slope FFF-specific parameters are in line with the possible energy underestimation of the simulated results relative to experimental data. Conclusions: The agreement between Monte Carlo simulations and experimental data proved that the evaluated Varian phase-space files for FFF beams from TrueBeam can be used as radiation sources for accurate Monte Carlo dose estimation, especially for field sizes up to 10 × 10 cm{sup 2}, that is the range of field sizes mostly used in combination to the FFF, high dose rate beams.

61 RADIATION PROTECTION AND DOSIMETRY↗