Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase two”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies4,5 at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database were investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components was used as an example in this study.

Daimaru, Takuro↗

Two-Phase Turbulent Kinetic Energy Budget Computation in Co-Current Taylor Bubble Flow

Simulation of two-phase flows is relevant for reactor design and safety at normal operation or during accident scenarios. Often, the two-phase flow is in a regime in which slugs are formed or where the flow stratifies. Modeling such situations using standard single-phase Reynolds-averaged Navier-Stokes (RANS) turbulence models fails due to an overestimation of the eddy viscosity at the resolved two-phase interface. To solve this, an ad hoc turbulence damping term has been proposed in the literature that reduces the turbulence production locally at a two-phase interface, analogously to turbulence wall functions. However, this approach must be tailored to the specific setting and does not consider physical contributions such as surface tension or flow topology. Therefore, the problem of two-phase interfacial turbulence must be studied more in-depth. In this work, we consider co-current turbulent Taylor bubble flow using high-fidelity numerical simulation. The Basilisk code is used to simulate a Taylor bubble rising in a vertical pipe. By simulating the bubble in a moving frame of reference, we may study the turbulent kinetic energy (TKE) budgets ahead of the bubble, in its wake, and across the interface. The implementation of the TKE budget computation and the underlying averaging techniques are validated for the single-phase region ahead of the Taylor bubble using reference direct numerical simulation data. The analysis of the TKE budgets in the setting of Taylor bubble flow allows for the study of how turbulence behaves due to the presence of a two-phase interface and, in turn, supports the improvement of two-phase RANS models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Validation of a Two-Phase Thermal-Hydraulic CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance Computational Fluid Dynamics (CFD) code NEK5000. The goal of this work is to verify and validate the two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) previously developed at Argonne but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2020. This report focuses on verification and validation of the water-steam boiling model NEK-2P Two-Phase, CFD code. The NEK-2P was validated with Nuclear Power Engineering Corporation (NUPEC) Pressurized Water Reactor (PWR) Sub-channel and Bundle Test (PSBT) void distribution benchmark. Three different simulations were performed and analyzed for various operating conditions such as wall-heat flux and sub-cooled inlet temperatures. Reasonably good agreement with measured data was obtained in predicting the measured void distributions. Simulations were performed for Virginia Tech. (VT) 3x3 rod bundle geometry with and without spacers. The preliminary results were presented for Simplified Spacer Grid (SSG). In addition, the implementation of interface reconstruction model was tested with one of the Becker benchmark Critical Heat Flux (CHF) experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Two-Phase Technology at NASA/Johnson Space Center

Since the baseline International Space Station (ISS) External Active Thermal Control System (EATCS) was changed from a two-phase mechanically pumped system to a single phase cascade system in the fall of 1993, two-phase EATCS research has continued at a low level at JSC. One of-the lessons of the ISS EATCS selection was that two-phase thermal control systems must have significantly lower power than comparable single phase systems to overcome their larger radiator area, larger line and fluid mass, and perceived higher technical risk. Therefore, research at JSC has concentrated on low power mechanically pumped two-phase EATCSs. In the presentation, the results of a study investigating the trade of single and two-phase mechanically pumped EATCSs for space vehicles will be summarized. The low power two-phase mechanically pumped EATCS system under development at JSC will be described in detail and the current design status of the subscale test unit will be reviewed. Also, performance predictions for a full size EATCS will be presented. In addition to the discussion of two-phase mechanically pumped EATCS development at JSC, two-phase technologies under development for biological water processing will be discussed. These biological water processor technologies are being prepared for a 2001 flight experiment and subsequent usage on the TransHab module on the International Space Station.

Ungar, Eugene K.↗

Review of two-phase flow liquid metal MHD and turbine energy conversion concepts for space applications

Two-phase energy conversion systems could be liquid metal magnetohydrodynamic (LMMHD) with no moving parts or two-phase turbines. Both of them are inherently simple and reliable devices which can operate in a wide range of temperatures. Their thermal efficiency is significantly higher than for conventional cycles due to reheat of vapor by liquid phase during the energy converting expansion. Often they can be more easily coupled to heat sources. These features make two-phase systems particularly promising for space application. Insufficient research has been done in the past. So far achieved LMMHD generator and two-phase turbine efficiencies are in the 40 to 45 percent range. However if certain fluid dynamic and design problems are resolved these efficiencies could be brought into the range of 70 percent. This would make two-phase systems extremely competitive as compared to present or other proposed conversion system for space. Accordingly, well directed research effort on potential space applications of two-phase conversion systems would be a wise investment.

Fabris, Gracio↗

Definition of two-phase flow behaviors for spacecraft design

Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. A boiling and condensing experiment was built in which R-12 was used as the working fluid. A two-phase pump was used to circulate a freon mixture and allow separate measurements of the vapor and liquid flow streams. The experimental package was flown five times aboard the NASA KC-135 aircraft which simulates zero-g conditions by its parabolic flight trajectory. Test conditions included stratified and annual flow regimes in 1-g which became bubbly, slug, or annular flow regimes on 0-g. A portion of this work is the analysis of adiabatic flow regimes. The superficial velocities of liquid and vapor have been obtained from the measured flow rates and are presented along with the observed flow regimes.

Reinarts, Thomas R.↗

Improvements to CTF Closure Models for Modelling of Two-Phase Flow

This report documents the efforts to improve the CTF prediction of void fraction and two-phase pressure drop by improving two-phase closure models. Previous validation activities have revealed that CTF tends to overpredict void fraction and two-phase pressure drop. In response to this, two approaches were taken to improve CTF’s predictive capabilities. Based on findings that the interfacial drag and subcooled boiling models significantly impact void prediction, alternative closure models for these physical effects were found and implemented into the code. An extensive assessment was performed by using the existing and newly added two-phase experimental data, which showed that void prediction, wall temperature, and two-phase pressure-drop results are improved by using the newly implemented models. A second approach for improving CTF modeling accuracy involved the use of a Bayesian calibration process that uses CTF validation data to optimize selected modeling coefficients and closure model multipliers to achieve a more accurate prediction of experimental results. A similar assessment was performed with calibrated models that improved the void and pressure-drop prediction for test cases that were both included and not included in the calibration dataset. Results of this study will be used to change the models used in CTF to achieve more accurate BWR analyses moving forward. This study also identified opportunities for improving additional closure models and other opportunities to use calibration techniques to improve CTF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Two-phase turbine engines

A description is given of a two-phase turbine which utilizes a uniform mixture of gas and liquid accelerated in nozzles of the types reported by Elliott and Weinberg (1968). The mixture acts directly on an axial flow or tangential impulse turbine or is separated into gas and liquid streams which operate separately on a gas turbine and a hydraulic turbine. The basic two-phase cycles are examined, taking into account working fluids, aspects of nozzle expansion, details of turbine cycle operation, and the effect of mixture ratio variation. Attention is also given to two-phase nozzle efficiency, two-phase turbine operating characteristics and efficiencies, separator turbines, and impulse turbine experiments.

Elliott, D. G.↗

A Comparison of System Architectures for a Mechanically Pumped Two-Phase Thermal Control System

The NASA Jet Propulsion Laboratory is developing a mechanically pumped two-phase fluid loop thermal control system to enable novel mission designs and greater science return. Pumped two-phase fluid loops have the potential to provide robust and effective thermal control that combine the best aspects of passive two-phase systems (heat pipes) and mechanically pumped single-phase fluid loops. The current program requirements include the development of a system with multiple 1 sq.m evaporators, each of which is capable of remaining spatially and temporally isothermal while accommodating heat loads of up to 500 W and local fluxes of up to 5 W/sq.cm. The goal is to attain this using less than 5 W of power. Such a system would be able to accommodate the next generation of payload and bus electronics while using minimal resources. This paper compares two different mechanically pumped two-phase fluid loop architectures in the context of these requirements. A mixed flow and separated flow architecture are compared on a theoretical and experimental basis. Test data from sub-scale, single evaporator/single condenser, mixed flow and separated flow testbeds are presented. In addition, a model is introduced to better understand separated flow systems and some expressions for the theoretical performance limits of such systems are developed. To date, the investigation suggests that a separated flow architecture is better suited to the program requirements. Separated flow systems have the potential to accommodate an isothermalizing two-phase evaporator while using lower levels of power than would be required for a mixed flow system. In addition, it is argued that separated flow systems are more robust and amenable to analysis than mixed flow systems, since they significantly reduce the occurrence of two-phase flow by separating phases in the evaporator. Future work will include developing a full-scale testbed that includes multiple evaporators and condensers in a representative flight configuration.

Furst, Benjamin↗

Definition of two-phase flow behaviors for spacecraft design

Data for complete models of two-phase flow in microgravity are taken from in-flight experiments and applied to an adiabatic flow-regime analysis to study the feasibility of two-phase systems for spacecraft. The data are taken from five in-flight experiments by Hill et al. (1990) in which a two-phase pump circulates a freon mixture and vapor and liquid flow streams are measured. Adiabatic flow regimes are analyzed based on the experimental superficial velocities of liquid and vapor, and comparisons are made with the results of two-phase flow regimes at 1 g. A motion analyzer records the flow characteristics at a rate of 1000 frames/sec, and stratified flow regimes are reported at 1 g. The flow regimes observed under microgravitational conditions are primarily annular and include slug and bubbly-slug regimes. The present data are of interest to the design and analysis of two-phase thermal-management systems for use in space missions.

Reinarts, Thomas R.↗

Modeling the use of a binary mixture as a control scheme for two-phase thermal systems

Two-phase thermal loops using mechanical pumps, capillary pumps, or a combination of the two have been chosen as the main heat transfer systems for the space station. For these systems to operate optimally, the flow rate in the loop should be controlled in response to the vapor/liquid ratio leaving the evaporator. By substituting a mixture of two non-azeotropic fluids in place of the single fluid normally used in these systems, it may be possible to monitor the temperature of the exiting vapor and determine the vapor/liquid ratio. The flow rate would then be adjusted to maximize the load capability with minimum energy input. A FLUINT model was developed to study the system dynamics of a hybrid capillary pumped loop using this type of control and was found to be stable under all the test conditions.

Benner, S. M.↗

Phase evolution in two-phase alloys during severe plastic deformation

Herein, phase evolution in FCC metals with strongly interacting alloy components during severe plastic deformation is investigated using molecular dynamics simulations. Specifically, we study the alloy microstructure in steady state, nucleation and growth of precipitates in supersaturated alloys, and the decomposition of precipitates in undersaturated alloys. The results are compared to a modified effective temperature model, providing a physical understanding for the atomic processes underlying the model and a perspective on its strengths and weaknesses. Key observations in this work are nucleation and growth of precipitates during SPD at a temperature of 100 K; Gibbs-Thomson-like behavior relating solubility to precipitate size under steady-state shearing; a direct relationship between the effective temperature and the shear modulus; and the importance of cluster agglomeration during precipitate growth. The study also reveals that the mechanisms of forced chemical mixing depends on precipitate size, adding complications for effective temperature models describing inhomogeneous systems. The simulations are shown to provide good semiquantitative agreement with experimental findings reported in the literature.

36 MATERIALS SCIENCE↗

Buoyant thermocapillary flow with nonuniform supra-heating. I - Liquid-phase behavior. II - Two-phase behavior

The present computational study of transient heat transfer and fluid flow in a circular pool of n-decane which is undergoing central radiative heating from above gives attention to the volumetric absorption of the radiation incident on the pool surface. The first part of this study notes that buoyancy influences the number and recirculation rates of the subsurface vortices by stabilizing hot subsurface fluid above the colder core fluid; this affects the liquid surface temperature profile and in turn governs the velocity profile that is due to thermocapillarity. In the second part, the effects of gas-liquid phase coupling, variable density and thermophysical properties, and vaporization are considered.

Schiller, David N.↗

Design and test of a mechanically pumped two-phase thermal control flight experiment

A flight experiment of a mechanically pumped two-phase ammonia thermal control system, incorporating a number of new component designs, has been assembled and tested in a 1-g environment. Additional microgravity tests are planned on the Space Shuttle when Shuttle flights are resumed. The primary purpose of this experiment is to evaluate the operation of a mechanically pumped two-phase ammonia system, with emphasis on determining the performance of an evaporative Two-Phase Mounting Plate. The experiment also evaluates the performance of other specially designed components, such as the two-phase reservoir for temperature control, condensing radiator/heat sink, spiral tube boiler, and pressure drop experiment. The 1-g tests have shown that start-up of the two-phase experiment is easily accomplished with only a partial fill of ammonia. The experiment maintained a constant mounting plate temperature without flow rate controls over a very wide range of heat loads, flow rates, inlet flow conditions and exit qualities. The tests also showed the successful operation of the mounting plate in the heat sharing condensing mode.

Grote, M. G.↗

Thermal Vibrational Convection in a Two-phase Stratified Liquid

The response of a two-phase stratified liquid system subject to a vibration parallel to an imposed temperature gradient is analyzed using a hybrid thermal lattice Boltzmann method (HTLB). The vibrations considered correspond to sinusoidal translations of a rigid cavity at a fixed frequency. The layers are thermally and mechanically coupled. Interaction between gravity-induced and vibration-induced thermal convection is studied. The ability of applied vibration to enhance the flow, heat transfer and interface distortion is investigated. For the range of conditions investigated, the results reveal that the effect of vibrational Rayleigh number and vibrational frequency on a two-phase stratified fluid system is much different than that for a single-phase fluid system. Comparisons of the response of a two-phase stratified fluid system with a single-phase fluid system are discussed.

Chang, Qingming↗