A study for development of aerothermodynamic test model materials and fabrication technique

A literature survey, materials reformulation and tailoring, fabrication problems, and materials selection and evaluation for fabricating models to be used with the phase-change technique for obtaining quantitative aerodynamic heat transfer data are presented. The study resulted in the selection of two best materials, stycast 2762 FT, and an alumina ceramic. Characteristics of these materials and detailed fabrication methods are presented.

Dean, W. G.↗

Photographing flow fields and heat-transfer patterns in color simultaneously.

A color-schlieren technique is described that combines the flow-field shock shapes and the phase-change coating to give a very descriptive account of aerodynamic heating. This technique employs, in addition to the conventional schlieren system, a temperature-sensitive material as a thin surface coating that undergoes a visible phase change from opaque solid to clear liquid at a known temperature. The resulting pictures can lead to a better understanding of shock/boundary layer interactions, as shown with the aid of a specific example.

Creel, T. R., Jr.↗

Electron-beam flow visualization - Applications in the definition of configuration aerothermal characteristics.

Comparisons between flow visualization systems using electron-beam fluorescence, schlieren, and shadowgraph techniques illustrate the advantages associated with the electron beam. Specific applications of this method as an aid in defining the origin of erosion on a heat-transfer model are cited. Results of combined electron-beam oil-flow studies on configurations illustrate that the simultaneous definition of the external flow field and its surface flow can be obtained. Comparisons between the electron-beam oil-flow visualization method and phase-change coating heat-transfer tests on a shuttle ascent configuration indicate the complementary nature of these two testing techniques. Potential methods for improving the electron-beam technique are included.

Woods, W. C.↗

Hypersonic aerothermal characteristics of a manned low finenes ratio shuttle booster

An investigation of a winged booster model having canards and an ascent configuration comprised of the booster mounted in tandem with an orbiter model has been conducted at Mach 10.2 in the continuous flow hypersonic tunnel. Longitudinal and lateral directional force characteristics were obtained over angle of attack ranges of -12 deg to 60 deg for the booster and -11 deg to 11 deg for the ascent configuration. Interference heating effects on the booster using the phase-change coating technique were determined at 0 deg angle of attack. Some oil flow photographs of the isolated booster and orbiter and ascent configuration are also presented.

Bernot, P. T.↗

Thermal modeling of phase change solidification in thermal control devices including natural convection effects

Natural convection effects in phase change thermal control devices were studied. A mathematical model was developed to evaluate natural convection effects in a phase change test cell undergoing solidification. Although natural convection effects are minimized in flight spacecraft, all phase change devices are ground tested. The mathematical approach to the problem was to first develop a transient two-dimensional conduction heat transfer model for the solidification of a normal paraffin of finite geometry. Next, a transient two-dimensional model was developed for the solidification of the same paraffin by a combined conduction-natural-convection heat transfer model. Throughout the study, n-hexadecane (n-C16H34) was used as the phase-change material in both the theoretical and the experimental work. The models were based on the transient two-dimensional finite difference solutions of the energy, continuity, and momentum equations.

Ukanwa, A. O.↗

Heating and flow-field studies on a straight-wing hypersonic reentry vehicle at angles of attack from 20 to 80 deg with simulation of real-gas trends

Data are presented from a series of phase-change heat transfer and flow visualization tests at Mach 7.4, 8, and 10.3 in air, Mach 19.5 in nitrogen, Mach 20.3 in helium, and Mach 6 in tetrafluoromethane (CF4) on the windward surface of a straight wing hypersonic reentry configuration for angles of attack from 20 deg to 80 deg. The results indicate that: (1) for hypersonic stream Mach numbers, the flow field over the straight-wing configuration is essentially independent of Mach number, (2) transition Reynolds number decreases with increasing angle of attack, (3) at some critical angle of attack, the wing-shock standoff distance is greatly increased and the stagnation line moves downstream from the wing leading edge, (4) value of the critical angle of attack is very sensitive to the flow shock density ratio or effective gamma, and (5) at angles of attack above the critical value for all gases, the nondimensional level of heat transfer to the wing is higher for the higher shock density ratio flows.

Hunt, J. L.↗

Heat transfer tests of the NASA-MSC space shuttle configuration at the Langley Research Center Mach 8 Variable Density Facility

The experimental investigations performed on the NASA-Manned Spacecraft Center Space Shuttle orbiter and booster configurations at a Mach 8 variable density facility are presented. The test program was a series of aerothermodynamic wind tunnel tests that were run over a range of angles of attack, yaw angles, and Reynolds numbers. Objectives of the test program were to obtain heat transfer data over the NASA-Manned Spacecraft Center Space Shuttle orbiter, booster, and launch configurations for a range of angles of attack from - 20 to + 30 deg, yaw angles of 0 and + or - 6 deg, and Reynolds numbers of 0.6, 2.0, and 3.7 x one million. The phase-change coating technique was used to obtain heat transfer data. Information received from these tests will be instrumental in performing thermal protection systems studies and vehicle aerodynamic design.

Connor, L. E.↗

Advanced Thermal Control Flight Experiment.

The advanced Thermal Control Flight Experiment on the Applications Technology Satellite (ATS-F) will evaluate, for the first time in a space environment, the performance of a feedback-controlled variable conductance heat pipe and a heat pipe thermal diode. In addition, the temperature control aspects of a phase-change material (PCM) will be demonstrated. The methanol/stainless steel feedback-controlled heat pipe uses helium control gas that is stored in a wicked reservoir. This reservoir is electrically heated through a solid state controller that senses the temperature of the heat source directly. The ammonia/stainless steel diode heat pipe uses excess liquid to block heat transfer in the reverse direction. The PCM is octadecane. Design tradeoffs, fabrication problems, and performance during qualification and flight acceptance tests are discussed.

Kirkpatrick, J. P.↗

Effects of surface roughness on the aerodynamic characteristics of the modified 089 B shuttle orbiter at Mach 6 (LA15)

A one hundredth scale model of the modified 089B shuttle orbiter was tested in the Langley 20-Inch Mach 6 tunnel. Force and moment, surface pressure and oilflow data were obtained on one model, and phase-change coating data were obtained on another. The pressure tests were conducted first; the tubes were clipped near the base of the model and then the force and moment and oil flow tests conducted. Angles of attack for the tests were from 20 deg to 35 deg and are commensurate with the range of flight values from entry down to Mach 5. The design flight Reynolds number at Mach 6, based on model length, was 15 million, which could not be obtained in the tunnel; therefore, the tests were conducted at the highest and lowest values for this model in the tunnel, 9.4 million and 4.0 million, respectively, to indicate Reynolds number effects. Two control deflection combinations, representative of the bank and pitch control limits of the design flight trajectory, were used.

Ashby, G. C., Jr.↗

Development of an apparatus to measure thermophysical properties of wind tunnel heat transfer models

The apparatus and technique for measuring the thermophysical properties of models used with the phase-change paint method for obtaining wind tunnel heat transfer data are described. The method allows rapid measurement of the combined properties in a transient manner similar to an actual wind tunnel test. An effective value of the thermophysical properties can be determined which accounts for changes in thermal properties with temperature or with depth into the model surface. The apparatus was successfully tested at various heating rates between 19,000 and 124,000 watts per square meter.

Romanowski, R. F.↗

Heat-transfer tests on the Rockwell International space shuttle orbiter with and without simulated protuberances

Aerothermodynamic tests on the forward half of the Rockwell International Space Shuttle Orbiter Configuration 140C were conducted at Mach number 8. The phase-change paint and thin-skin thermocouple techniques were used to determine the aerodynamic heating rates on the Orbiter models during simulated atmospheric reentry. Smooth 0.04-scale models and models with scaled protuberances and indentations which simulated the windshields, cargo bay door hinges, vents, and thruster nozzles were tested over an angle-of-attack range from 20 to 45 deg at yaw angles from -5 to 5 deg and at Reynolds numbers, based on the total Orbiter scaled length, from 2.15 to 15.9 million. Comparisons of the model heat-transfer rates obtained with a smooth surface and with scaled protuberances are presented.

Carter, L. D.↗

ATS-6 - Flight performance of the Advanced Thermal Control Flight Experiment

The Advanced Thermal Control Flight Experiment on ATS-6 was designed to demonstrate the thermal control capability of a thermal diode (one-way) heat pipe, a phase-change material for thermal storage, and a feedback-controlled heat pipe. Flight data for the different operational modes are compared to ground test data, and the performance of the components is evaluated on an individual basis and as an integrated temperature-control system.

Kirkpatrick, J. P.↗

Proportionality between Doppler noise and integrated signal path electron density validated by differenced S-X range

Observations of Viking differenced S-band/X-band (S-X) range are shown to correlate strongly with Viking Doppler noise. A ratio of proportionality between downlink S-band plasma-induced range error and two-way Doppler noise is calculated. A new parameter (similar to the parameter epsilon which defines the ratio of local electron density fluctuations to mean electron density) is defined as a function of observed data sample interval (Tau) where the time-scale of the observations is 15 Tau. This parameter is interpreted to yield the ratio of net observed phase (or electron density) fluctuations to integrated electron density (in RMS meters/meter). Using this parameter and the thin phase-changing screen approximation, a value for the scale size L is calculated. To be consistent with Doppler noise observations, it is seen necessary for L to be proportional to closest approach distance a, and a strong function of the observed data sample interval, and hence the time-scale of the observations.

Berman, A. L.↗

Range safety signal propagation through the SRM exhaust plume of the space shuttle

Theoretical predictions of plume interference for the space shuttle range safety system by solid rocket booster exhaust plumes are reported. The signal propagation was calculated using a split operator technique based upon the Fresnel-Kirchoff integral, using fast Fourier transforms to evaluate the convolution and treating the plume as a series of absorbing and phase-changing screens. Talanov's lens transformation was applied to reduce aliasing problems caused by ray divergence.

Boynton, F. P.↗

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen↗

Undercooling minimization in ultrasound coupled DTA measurements of molten salts

Molten salts are ionic liquids that are used for the electrolytic pyroprocessing of metals and as heat transfer fluids in very high temperature processes. Recently, halide-based molten salt reactors (MSR) have gained momentum for high density and environmentally responsible electricity generation. The function of these reactors and their fuel cycle depend on a knowledge of the halide salt’s thermodynamic properties [1]. Therefore, high accuracy phase equilibria of MSR relevant base halide and actinide containing salts are needed. Modern thermal analysis of the phase transitions of halide salts is usually done during heating at relatively high scan rates with commercial devices. Normally such measurements are adequate for pure or pseudo-binary salts. However, as the number of components in the mixture increases, accurately resolving the liquidus becomes increasingly difficult. Reversing the scanning mode greatly increases the sensitivity of phase transition measurements but can decrease accuracy due to undercooling [2] — a common occurrence in molten halide systems [3]. This work presents the development of a differential thermal analysis (DTA) cell intended for use in radiological gloveboxes. Non-contact ultrasonic agitation of the halide salt is implemented to limit kinetic limitations on crystallization during cooling to minimize undercooling [4]. Measurements on halide salts are also presented to elucidate the effect of non-contact mixing on undercooling. Reference [1] S. Boyd and C. Taylor, “3 - Chemical fundamentals and applications of molten salts,” in Molten Salt Reactors and Thorium Energy, T. J. Dolan, Ed., Woodhead Publishing, 2017, pp. 29–91. doi: 10.1016/B978-0-08-101126-3.00003-8. [2] K. Nitsch, A. Cihlár, and M. Rodová, “Molten state and supercooling of lead halides,” J. Cryst. Growth, vol. 264, no. 1, pp. 492–498, Mar. 2004, doi: 10.1016/j.jcrysgro.2004.01.011. [3] L. Rycerz, “Practical remarks concerning phase diagrams determination on the basis of differential scanning calorimetry measurements,” J. Therm. Anal. Calorim., vol. 113, no. 1, pp. 231–238, Jul. 2013, doi: 10.1007/s10973-013-3097-0. [4] Md. H. Zahir, S. A. Mohamed, R. Saidur, and F. A. Al-Sulaiman, “Supercooling of phase-change materials and the techniques used to mitigate the phenomenon,” Appl. Energy, vol. 240, pp. 793–817, Apr. 2019, doi: 10.1016/j.apenergy.2019.02.045.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Self‐Strain Suppression of the Metal‐to‐Insulator Transition in Phase‐Change Oxide Devices

Strongly correlated materials exhibiting phase transitions which can be controlled through external stimuli, such as electric fields, are promising for future computing technologies beyond conventional semiconductor transistors. Devices that take advantage of structural phase transitions have inherent built‐in memory, reminiscent of synapses and neurons, and are thus natural candidates for neuromorphic computing. Of particular interest are phase‐change oxides, which allow for control over the metal‐to‐insulator transition. Here, X‐ray nano‐diffraction structural imaging of micro‐devices fabricated with the archetypal phase‐change material vanadium sesquioxide (V 2 O 3 ) is reported. The devices contain a Ga ion‐irradiated region where the metal‐to‐insulator transition critical temperature is lowered, a useful feature for controlling neuron‐like spiking behavior. Results show that strain, induced by crystal lattice mismatch between the pristine and irradiated material, leads to a suppression of the metal‐to‐insulator‐transition. Suppression occurs within the irradiated region or along its edges, depending on the defect‐distribution and the size of the region. The observed self‐straining effect can extend to other phase‐change oxides and dominate as device dimensions are reduced and become too small to dissipate strain within the irradiated region. The findings are important for phase engineering in phase‐change devices and highlight the necessity to study phase transitions at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗