Search NASA⌕ Search

SEARCH · Search NASA

Results for “pipe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of Heat Pipe Reactor Modeling in SAM

System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods available in PETSc. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. This report presents the development of new capabilities for modeling the heat pipe type reactor systems. The need for power at remote locations away from a reliable electrical grid is an important niche for nuclear energy. Heat pipe-cooled fast-spectrum nuclear reactors are well suited for these applications. The key feature of the heat pipe reactors is the use of heat pipes for heat removal from the reactor core. The heat pipe makes use of the phase change of the working fluid and transports a large amount of heat from the evaporator to the condensation end with very small temperature drops. In contrast to the traditional nuclear reactor system that makes use of pumped loop for extracting the thermal power, the heat pipe reactors make use of hundreds of heat pipes for removing the thermal power (including the decay heat) passively. This could potentially significantly improve the reliability and safety of the reactor systems. The essential part in the analysis of a heat pipe type reactor is the modeling of heat transport inside the heat pipe. The capability of SAM is extended in this work to enable the modeling of the conventional heat pipe. Two alternative modeling options, 2D-RZ Heat conduction and 3D-1D coupling, are developed, which are both based on the assumption that the heat pipe vapor core can be modeled as a superconductor of extremely high thermal conductivity. Both modeling options are verified with a simplified thermal resistance model. The heat pipes are also coupled with the fuel region of a prototype micro reactor under both normal and off-normal conditions. It is confirmed that both modeling options can correctly model the heat transport in the heat-pipe reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-Physics Simulations of Heat Pipe Micro Reactor

System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. This report presents the development of new capabilities for modeling the heat pipe type reactor systems. The need for power at remote locations away from a reliable electrical grid is an important niche for nuclear energy. Heat pipe-cooled fast-spectrum nuclear reactors are well suited for these applications. The key feature of the heat pipe reactors is the use of heat pipes for heat removal from the reactor core. The heat pipe makes use of the phase change of the working fluid and transports a large amount of heat from the evaporator to the condensation end with very small temperature drops. In contrast to the traditional nuclear reactor system that makes use of pumped loop for extracting the thermal power, the heat pipe reactors make use of hundreds of heat pipes for removing the thermal power (including the decay heat) passively. This could potentially significantly improve the reliability and safety of the reactor systems. The essential part in the analysis of a heat pipe type reactor is the modeling of heat transport inside the heat pipe. The capability of SAM was extended to enable the modeling of the conventional heat pipe. The full suite of non-LWR codes for confirmatory analysis at NRC is known as the Comprehensive Reactor Analysis Bundle (CRAB). It makes use of existing NRC codes, and integrates them with several codes developed through the DOE-NE’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this report, the heat pipe micro reactor is simulated using three submodules under CRAB. The MAMMOTH module is used to simulate the reactor kinetics behavior of the micro reactor; the SAM module is used to simulate the heat conduction in the reactor core and heat removal through the heat pipe heat exchangers and Reactor Cavity Cooling System (RCCS); and the MOOSE Tensor Mechanics module is used to simulate the thermal expansion of the reactor cores. The different sub-models are coupled together using MOOSE’s MultiApp system and executed using the BlueCrab application. The new capability has been demonstrated by a steady-state operation analysis, a failure of a single central heat pipe transient analysis, and a loss of heat sink transient analysis. The fully coupled model is shown to work well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NSTTF Gen 3 Topic 1 CSP Liquid-Pathway to SunShot Pipe Preheating System Comparison Report

The primary objective of this report is to determine a viable pipe preheating system for a chloride-salt blend that can preheat the pipe to 450°C and withstand a maximum exposure temperature of 750°C. Preheating involves heating the pipe to a specific desired temperature, called preheat temperature, of the pipe. The temperature is maintained by heated molten salt flowing through the piping system. This report reviews 5-types of pipe preheating systems, of which three pipe preheating systems- MI cable, heat tape, and ceramic fiber heaters, were found to be viable for the Gen 3 Liquid Pathway application. The report reviews the pipe preheating efficiency of conduction verses radiant heat transfer. For each of the 5 types of pipe preheating systems, the report describes the system and addresses installation requirements, temperature control, reliability survey, and pre-construction verification testing for the most applicable preheating system. Under Appendix A, images from design drawings demonstrate pipe routing with the preheating system and insulation attached to the pipe along with pipe guides and pipe supports, as designed using Caesar II finite element analysis within the SNL NSTTF Solar Power Tower.

36 MATERIALS SCIENCE↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Robotic NDA of Holdup Deposits in Gaseous Diffusion Piping by Gamma Assay of Uranium-235 - 18331

This research exploits in-pipe access to develop robotically deployed, high-cadence, accurate, certain, paperless assay of U-235 in holdup deposits within process piping. Prior radiometric assay from outside the pipes suffered from manual deployment challenges, attenuation of detection through pipe walls, long counting times, approximate modeling, and shortfalls associated with transcription and human interpretation. These downsides limited the speed, quality, and economy of assay resulting in vast cost and budget consequences to D and D. D and D of outdated facilities cuts into these pipes as part of the demolition process, creating the unique, previously unexploited possibility of robotic in-pipe assay. The assay collimates radiation emanating from all but a short segment of pipe wall from reaching a gamma detector. Hence, the detector only views and measures source from a short segment of pipe at a given time. This is achieved by an innovative pair of collimating discs that are coaxial with the pipe and positioned fore and aft of the detector. The detector assembly is translated through pipes by an autonomous mobile robot. Beyond radiometric assay of U-235, the robot images and geometrically models the pipe interior and deposit appearance. The robot is recovered from the same pipe opening from which it is launched, hence it drives the same distance out and back, measuring the same deposits twice. This achieves redundant radiometric and odometric measurements which adds further to statistical significance of the method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.

97 - MATHEMATICS AND COMPUTING↗

Thermostructural applications of heat pipes for cooling leading edges of high-speed aerospace vehicles

Heat pipes have been considered for use on wing leading edge for over 20 years. Early concepts envisioned metal heat pipes cooling a metallic leading edge. Several superalloy/sodium heat pipes were fabricated and successfully tested for wing leading edge cooling. Results of radiant heat and aerothermal testing indicate the feasibility of using heat pipes to cool the stagnation region of shuttle-type space transportation systems. The test model withstood a total seven radiant heating tests, eight aerothermal tests, and twenty-seven supplemental radiant heating tests. Cold-wall heating rates ranged from 21 to 57 Btu/sq ft-s and maximum operating temperatures ranged from 1090 to 1520 F. Follow-on studies investigated the application of heat pipes to cool the stagnation regions of single-stage-to-orbit and advanced shuttle vehicles. Results of those studies indicate that a 'D-shaped' structural design can reduce the mass of the heat-pipe concept by over 44 percent compared to a circular heat-pipe geometry. Simple analytical models for heat-pipe startup from the frozen state (working fluid initially frozen) were adequate to approximate transient, startup, and steady-state heat-pipe performance. Improvement in analysis methods has resulted in the development of a finite-element analysis technique to predict heat-pipe startup from the frozen state. However, current requirements of light-weight design and reliability suggest that metallic heat pipes embedded in a refractory composite material should be used. This concept is the concept presently being evaluated for NASP. A refractory-composite/heat-pipe-cooled wing leading edge is currently being considered for the National Aero-Space Plane (NASP). This concept uses high-temperature refractory-metal/lithium heat pipes embedded within a refractory-composite structure and is significantly lighter than an actively cooled wing leading edge because it eliminates the need for active cooling during ascent and descent. Since the NASP vehicle uses cryogenic hydrogen to cool structural components and then burns this fuel in the combustor, hydrogen necessary for descent cooling only, when the vehicle is unpowered, is considered to be a weight penalty. Details of the design of the refractory-composite/heat-pipe-cooled wing leading edge are currently being investigated. Issues such as thermal contact resistance and thermal stress are also being investigated.

Camarda, Charles J.↗

EXPERIMENTAL VALIDATION OF THEORETICAL BURST STRENGTH SOLUTION FOR DEFECT-FREE THICK-WALLED PIPES

The burst pressure of line pipes is an important strength property required in pipeline design and integrity management. Historically, the Barlow formula in conjunction with the ultimate tensile stress (UTS) of pipeline steels were utilized to estimate the burst strength of line pipes. However, the Barlow formula did not consider the plastic flow effect for ductile steels and is applicable only to thin-walled pipes. In 2006, the present author proposed a new multiaxial plastic yield theory and obtained a theoretical Zhu-Leis solution of burst strength for defect-free thin-walled pipes in term of UTS and strain hardening exponent n of pipeline steels. The Zhu-Leis solution has been validated by various burst test data for thin-walled pipelines for a wide range of steel grades from Grade B to X120. Recently, the present author extended the Zhu-Leis theory of plasticity to thick-walled pipes and obtained the Zhu-Leis solution of burst pressure for thick-walled pipes. The proposed burst pressure solution is applicable to both thin and thick-walled pipes. To experimentally validate the proposed theoretical burst pressure solution, this paper obtains a set of burst test data for three thick-walled pipes in Grade B carbon steel with a nominal diameter of 2.375 inches and three nominal wall thicknesses, resulting in D/t = 15.4, 10.9, 6.9. Through comparisons, these burst data validate the theoretical burst pressure solution for thick-walled pipes. Moreover, two additional burst test datasets collected from literature for thin and thick-walled pipes further validate the proposed burst pressure solution for both thin and thick-walled pipes.

Zhu, Xiankui↗

Arterial and grooved cryogenic heat pipes.

Tests were conducted on two cryogenic heat pipes using nitrogen as the working fluid. Both pipes are 1.27 cm in diameter. The first pipe is 141 cm long and uses longitudinal grooves in the aluminum wall as the wick structure. The second pipe is 91 cm long and has an arterial wick adjacent to the wall. In addition, circumferential screw threads are machined along the entire length of the inside pipe wall. Both heat pipes primed with no difficulty in the horizontal position. Start-up after burn-out was obtained repeatedly. However, more testing is required to determine whether the artery pipe is as reliable as the grooved pipe with respect to priming. Once primed, the artery heat pipe is much less sensitive to elevation than the grooved design and, consequently, offers a significant advantage with respect to ground testing. Heat-transfer characteristics of the two pipes were comparable, with both pipes achieving the initial goal of 1000 watt-cm of heat-transport capability.

Brennan, P.↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.

Keddy, E.↗

Working Fluids for Increasing Capacities of Heat Pipes

A theoretical and experimental investigation has shown that the capacities of heat pipes can be increased through suitable reformulation of their working fluids. The surface tensions of all of the working fluids heretofore used in heat pipes decrease with temperature. As explained in more detail below, the limits on the performance of a heat pipe are associated with the decrease in the surface tension of the working fluid with temperature, and so one can enhance performance by reformulating the working fluid so that its surface tension increases with temperature. This improvement is applicable to almost any kind of heat pipe in almost any environment. The heat-transfer capacity of a heat pipe in its normal operating-temperature range is subject to a capillary limit and a boiling limit. Both of these limits are associated with the temperature dependence of surface tension of the working fluid. In the case of a traditional working fluid, the decrease in surface tension with temperature causes a body of the liquid phase of the working fluid to move toward a region of lower temperature, thus preventing the desired spreading of the liquid in the heated portion of the heat pipe. As a result, the available capillary-pressure pumping head decreases as the temperature of the evaporator end of the heat pipe increases, and operation becomes unstable. Water has widely been used as a working fluid in heat pipes. Because the surface tension of water decreases with increasing temperature, the heat loads and other aspects of performance of heat pipes that contain water are limited. Dilute aqueous solutions of long-chain alcohols have shown promise as substitutes for water that can offer improved performance, because these solutions exhibit unusual surface-tension characteristics: Experiments have shown that in the cases of an aqueous solution of an alcohol, the molecules of which contain chains of more than four carbon atoms, the surface tension increases with temperature when the temperature exceeds a certain value. There are also other liquids that have surface tensions that increase with temperature and could be used as working fluids in heat pipes. For example, as a substitute for ammonia, which is the working fluid in some heat pipes, one could use a solution of ammonia and an ionic surfactant.

Chao, David F.↗

High-Fidelity Modeling and Experiments to Inform Safety Analysis Codes for Heat Pipe Microreactors

Heat pipe microreactors are reactor designs that primarily use liquid-metal heat pipes to cool the core. The main interest in heat pipes is the fact that they can remove heat passively. This, along with the use of liquid metal, allows the reactor to operate at higher temperatures. Although the use of heat pipes in nuclear reactors is new, liquid-metal heat pipe technology is mature. Nevertheless, experimental data on heat pipes are scarce, and very little is known about their behavior during abnormal operations and close to their thermal limits. Therefore, new experiments and accurate heat pipe simulations are needed to develop reliable closure models. This work describes a joint experimental and numerical investigation into heat pipes that attempts an initial closure of this gap. Further, the numerical and experimental efforts are currently proceeding in parallel, aimed at different aspects of heat pipes. The numerical part is focused on gaps in local closures, and the experiments capture the overall heat pipe behavior.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Robot for Nondestructive Assay of Holdup Deposits in Gaseous Diffusion Piping - 19504

Miles of contaminated pipe must be characterized as part of the decommissioning effort at deactivated gaseous diffusion enrichment facilities. The current method requires cutting away asbestos- lined thermal enclosures and performing repeated, elevated operations to manually perform nondestructive assay (NDA) on pipe from the outside. The RadPiper robot, part of the Pipe Crawling Activity Measurement System (PCAMS) developed by Carnegie Mellon University and commissioned for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, automatically measures U-235 in pipes from the inside. This improves certainty, increases safety, and greatly reduces measurement time. The heart of the RadPiper robot is a sodium iodide scintillation detector in an innovative disc-collimated assembly. By measuring from inside pipes, the robot significantly increases its count rate relative to external through-pipe measurements. The robot also provides imagery, models interior pipe geometry, and precisely measures distance in order to localize radiation measurements. Data collected by this system provides insight into pipe interiors that is simply not possible from exterior measurements, all while keeping operators safer. This paper describes the technical details of the PCAMS RadPiper robot. Key features for this robot include precision distance measurement, in-pipe obstacle detection, ability to transform for two pipe sizes, and robustness in autonomous operation. Test results demonstrating the robot's functionality are presented, including deployment tolerance tests, safeguarding tests, and localization tests. Integrated robot tests are also shown. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Precision In-Pipe Robot Localization with Reciprocal Sensor Fusion - 19516

Manual measurement of U-235 deposits in uranium enrichment piping is a costly, time consuming, and labor-intensive process that is a well-known cost and schedule driver. Autonomous, robotic innovation enabled by this research is revolutionizing the measurement speed, quality and safety of this important operation. The huge advantage is the robot's ability to measure from inside the pipes. The upside is sensing the geometry, appearance and radiometry directly. The downside is the inability to know precise, absolute position of the measurements in very long pipe runs. This paper develops the unprecedented localization required for this purpose. This paper presents the precise localization method designed for in-pipe radiation measurement robots. Unlike other in-pipe localization methods, this approach achieves millimeter-level accuracy in hundred-foot runs and does everything on one robot without relying on tether cable or communicating devices out of pipe, which is an important feature for nuclear in-pipe robot. It overcomes challenges usually encountered by in-pipe localization such as long travelling distance and operation time, narrow view angle, and featureless environment. The robot is equipped with encoders embedded in tracks which can record travelled distance, but encoder odometry drifts unacceptably due to slip and non-linearity. The robot also incorporates a laser range finder measuring the absolute distance, but range finder in long pipes has many misleading false measurements that are difficult to filter. The innovation here is to use one to filter/calibrate the other so that data used from the two sensors improve each other iteratively and reciprocally. The survey measurements accuracy of this localization method is proven by experiments comparing to ground truth and 'Zippering error' experiments that compare measurements to fixed features in pipes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.

97 - MATHEMATICS AND COMPUTING↗

Benchmark Gamma Spectroscopy Measurements of Uranium Hexafluoride in Aluminmum Pipe with a Sodium Iodide Detector

The expected increased demand in fuel for nuclear power plants, combined with the fact that a significant portion of the current supply from the blend down of weapons-source material will soon be coming to an end, has led to the need for new sources of enriched uranium for nuclear fuel. As a result, a number of countries have announced plans, or are currently building, gaseous centrifuge enrichment plants (GCEPs) to supply this material. GCEPs have the potential to produce uranium at enrichments above the level necessary for nuclear fuel purposes-enrichments that make the uranium potentially usable for nuclear weapons. As a result, there is a critical need to monitor these facilities to ensure that nuclear material is not inappropriately enriched or diverted for unintended use. Significant advances have been made in instrument capability since the current International Atomic Energy Agency (IAEA) monitoring methods were developed. In numerous cases, advances have been made in other fields that have the potential, with modest development, to be applied in safeguards applications at enrichment facilities. A particular example of one of these advances is the flow and enrichment monitor (FEMO). (See Gunning, J. E. et al., 'FEMO: A Flow and Enrichment Monitor for Verifying Compliance with International Safeguards Requirements at a Gas Centrifuge Enrichment Facility,' Proceedings of the 8th International Conference on Facility Operations - Safeguards Interface. Portland, Oregon, March 30-April 4th, 2008.) The FEMO is a conceptual instrument capable of continuously measuring, unattended, the enrichment and mass flow of {sup 235}U in pipes at a GCEP, and consequently increase the probability that the potential production of HEU and/or diversion of fissile material will be detected. The FEMO requires no piping penetrations and can be installed on pipes containing the flow of uranium hexafluoride (UF{sub 6}) at a GCEP. This FEMO consists of separate parts, a flow monitor (FM) and an enrichment monitor (EM). Development of the FM is primarily the responsibility of Oak Ridge National Laboratory, and development of the EM is primarily the responsibility of Los Alamos National Laboratory. The FM will measure {sup 235}U mass flow rate by combining information from measuring the UF{sub 6} volumetric flow rate and the {sup 235}U density. The UF{sub 6} flow rate will be measured using characteristics of the process pumps used in product and tail UF{sub 6} header process lines of many GCEPs, and the {sup 235}U density will be measured using commercially available sodium iodide (NaI) gamma ray scintillation detectors. This report describes the calibration of the portion of the FM that measures the {sup 235}U density. Research has been performed to define a methodology and collect data necessary to perform this calibration without the need for plant declarations. The {sup 235}U density detector is a commercially available system (GammaRad made by Amptek, www.amptek.com) that contains the NaI crystal, photomultiplier tube, signal conditioning electronics, and a multichannel analyzer (MCA). Measurements were made with the detector system installed near four {sup 235}U sources. Two of the sources were made of solid uranium, and the other two were in the form of UF{sub 6} gas in aluminum piping. One of the UF{sub 6} gas sources was located at ORNL and the other at LANL. The ORNL source consisted of two pipe sections (schedule 40 aluminum pipe of 4-inch and 8-inch outside diameter) with 5.36% {sup 235}U enrichment, and the LANL source was a 4-inch schedule 40 aluminum pipe with 3.3% {sup 235}U enrichment. The configurations of the detector on these test sources, as well as on long straight pipe configurations expected to exist at GCEPs, were modeled using the computer code MCNP. The results of the MCNP calculations were used to define geometric correction factors between the test source and the GCEP application. Using these geometric correction factors, the experimental 186 keV counts in the test geometry were extrapolated to the expected GCEP geometry, and calibration curves were developed. A unique method to analyze the measurement was also developed that separated the detector spectrum into the five detectable decay gamma rays emitted by {sup 235}U in the 120 to 200 keV energy range. This analysis facilitated the assignment of a consistent value for the detector counts originating from {sup 235}U decays at 186 keV. This value is also more accurate because it includes the counts from gamma energies other than 186 keV, which results in increased counting statistics for the same measurement time. The 186 keV counts expected as a function of pressure and enrichment are presented in the body of this report. The main result of this research is a calibration factor for 4-inch and 8-inch schedule 40 aluminum pipes. For 4-inch pipes, the {sup 235}U density is 0.62 {sup 235}U g/m{sup 3} per each measured 186 keV count.

March-Leuba, Jose A↗

Design, development and testing of a cryogenic temperature heat pipe for the icicle system

An analytical model was formulated for a cryogenic heat pipe, and thermal and transport analyses were developed to predict the performance characteristics of various heat pipe designs. These analyses permitted optimization of various design parameters. A series of four breadboard heat pipes were fabricated and tested to provide inputs such as internal film coefficients, minimum capillary radii, and wick permeabilities which are required for the analyses. The results of instrumentation, charging, and testing of cryogenic heat pipes were applied to the prototype heat pipes. After a thorough design analysis of three potential heat pipe wicks (slab, artery, and axial groove), the first two were chosen for application to two prototype heat pipes. Detailed designs were made of the two heat pipes and the units were fabricated. Tests were conducted which verified the integrity and safety margin of the design to withstand the internal pressure at ambient temperature and fatigue of thermal cycling. During the acceptance testing in the vacuum chamber, no difficulty was experienced in priming the slab-wick heat pipe and it met the performance design requirements. The artery-wick heat pipe would not prime with nitrogen working fluid for any test conditions.

Trimmer, D. S.↗

Thermion: Verification of a thermionic heat pipe in microgravity

The Idaho National Engineering Laboratory (INEL) is conducting intensive research in the design and development of a small excore heat-pipe-thermionic space nuclear reactor power system (SEHPTR). The SEHPTR spacecraft will be able to supply 40 kW of power in any given orbit. The key components in this reactor are the thermionic heat pipes. The heat pipes have two major functions: (1) to convert heat energy into electrical energy, and (2) to radiate the excess heat to space. Thermionic power conversion is the process of converting heat energy into electrical energy with no moving parts. Heat is applied to the cathode surface. This heat will boil off electrons that will jump across the gap to the cooler surface of the anode, which will cause a potential difference between the two plates and induce a current through the load. Thermionic power conversion is incorporated as part of the heat pipe. The heat pipe, which is being developed by Thermacore Inc., is actually two heat pipes. It uses a radial heat pipe, called the emitter, and an axial heat pipe collector. The emitter heat pipe will pass the heat from the nuclear core to the cathode surface. The collector heat pipe keeps the anode surface cooler by transferring the heat from the anode surface and radiating it to space.

Source record↗