Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Nuclear Spectroscopic Telescope Array (NuSTAR) Mission

The Nuclear Spectroscopic Telescope Array (NuSTAR) is a National Aeronautics and Space Administration (NASA) Small Explorer mission that carried the first focusing hard X-ray (6-79 keV) telescope into orbit. It was launched on a Pegasus rocket into a low-inclination Earth orbit on June 13, 2012, from Reagan Test Site, Kwajalein Atoll. NuSTAR will carry out a two-year primary science mission. The NuSTAR observatory is composed of the X-ray instrument and the spacecraft. The NuSTAR spacecraft is three-axis stabilized with a single articulating solar array based on Orbital Sciences Corporation's LEOStar-2 design. The NuSTAR science instrument consists of two co-aligned grazing incidence optics focusing on to two shielded solid state CdZnTe pixel detectors. The instrument was launched in a compact, stowed configuration, and after launch, a 10-meter mast was deployed to achieve a focal length of 10.15 m. The NuSTAR instrument provides sub-arcminute imaging with excellent spectral resolution over a 12-arcminute field of view. The NuSTAR observatory will be operated out of the Mission Operations Center (MOC) at UC Berkeley. Most science targets will be viewed for a week or more. The science data will be transferred from the UC Berkeley MOC to a Science Operations Center (SOC) located at the California Institute of Technology (Caltech). In this paper, we will describe the mission architecture, the technical challenges during the development phase, and the post-launch activities.

Telescope↗

Flight Integral Field Spectrograph (IFS) Optical Design for WFIRST Coronagraphic Exoplanet Demonstration

Based on the experience from Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST, we have moved to the flight instrument design phase. The specifications for flight IFS have similarities and differences from the prototype. This paper starts with the science and system requirement, discusses a number of critical trade-offs: such as IFS type selection, lenslet array shape and layout versus detector pixel accuracy, how to accommodate the larger Field Of View (FOV) and wider wavelength band for a potential add-on StarShade occulter. Finally, the traditional geometric optical design is also investigated and traded: reflective versus refractive, telecentric versus non-telecentric relay. The relay before the lenslet array controls the chief angle distribution on the lenslet array. Our previous paper has addressed how the relay design combined with lenslet arraypinhole mask can further compress the residual star light and increase the contrast. Finally, a complete phase A IFS optical design is presented.

Integral Field spectrograph↗

Comparison of commercially available polarizing gratings for mid-infrared studies

We present the results of lab comparison tests of performance for several commercially available grating polarizers sold for use at mid-infrared wavelengths. The tests were done using a polarized laser diode source (9.2 μm) and photoconductive HgCdTe single pixel detector. We describe some basic equations governing quantification of polarization performance, our instrumental test setup and our results. There is a great deal of difference in the contrast produced by polarizers from different companies. Availability of high-transmission, high-contrast polarizers for use at near and mid-infrared wavelengths will make it possible to routinely characterize polarization of astronomical sources, such as physical properties of dust grains and magnetic field lines around sources of interest.

Geis, J. M.↗

Design for Minimum Casualty Area – The IXPE Case

The Imaging X-Ray Polarimetry Explorer (IXPE) is a new international space observatory in NASA’s Small Explorer program, designed in a collaboration between the Italian Space Agency and NASA’s Marshall Space Flight Center, and built by Ball Aerospace. IXPE has an expected launch in November 2021, to a 600-km altitude equatorial orbit. IXPE is an astrophysics mission using three telescope assemblies to measure the polarization of cosmic X-rays. Each assembly is composed of a mirror module assembly (MMA) with 24 nested nickel-cobalt cylindrical shells and a unique, polarization-sensitive, gas pixel detector (GPD) within the detector unit (DU). As a NASA mission, IXPE must adhere to the orbital debris mitigation requirements specified in NASA Standard 8719.14 [1]; in the present work, we will only discuss reentry human casualty risk. As initially designed, the IXPE observatory exceeded NASA’s casualty risk threshold. IXPE does not include a propulsion system to perform a controlled reentry at the end of mission to mitigate the ground casualty risk. To reduce the risk from the uncontrolled reentry of this observatory, the IXPE design team worked with the NASA Orbital Debris Program Office to reduce the debris casualty area through design-for-demise and containment methods. The flight design of IXPE is now compliant with the ground casualty risk requirement at a casualty probability of 1:13,100 compared to a casualty requirement of better than 1:10,000.

C Ostrom↗

Adaptive Wavelength Scanning Lidar (AWSL) for 3D Mapping from Space

We present the design and performance of an adaptive wavelength scanning lidar (AWSL) for highly efficient mapping from low Earth orbit (LEO). Mapping is accomplished by steering a laser beam across 1,200 resolvable spots using wavelength tuning and grating dispersion. Any subset of these 1,200 spots can be selected by wavelength switching. The design is validated with an 1550-nm prototype using a fast wavelength-tuned (500-kHz) pulsed (2-ns) fiber laser with the beam dispersed by gratings for beam steering. Reflected pulses are detected with an eight-pixel detector array with single-photon sensitivity. Eight lidar returns are time-multiplexed to one output that is digitized with a single 1-GSPS-digitizer, to save power. A grating spectrometer rejects solar background noise spatially and spectrally, and images laser footprints on to the detector array. The gratings retain the fiber laser beam quality. We are developing a 1030-nm AWSL intended for a LEO SmallSat platform.

Guangning Yang↗

CEPS - A Compact Electron-Proton Spectrometer

Small mass/power sensors are needed for autonomous Moon surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. The proposed work will bring ability to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.

Radiation↗

Development of Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System (CASALS) for Swath Mapping From Space

We present the design and performance of a Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS) for 3D imaging from Space. With a single fast wavelength tuning laser, CASALS accomplishes a 1,200 resolvable spots swath mapping by grating dispersion wavelength steering. Any subset of these 1,200 spots can be selected by wavelength switching. The validation operating principle was accomplished and reported in IGASS-2022. With configurable base design, we report the designs and progress of the CASALS airplane campaign with 256 contiguous ground spots. It is accomplished with a single fast tuning lase at 1040-nm, 1.152MHz tuning rate, and pulse modulated 2-ns on each wavelength. Return pulses are mapped to an eight-pixel detector array with single-photon sensitivity. The lidar returns are time-multiplexed to two outputs that are digitized with two 1-GSPS-digitizer. A grating spectrometer rejects solar background noise spatially and spectrally. We are developing a 1040-nm CASALS intended for multiple LEO orbit missions: Earth Venture Mission on ESPA Grande, STV Mission on ESPA Grande SmallSat, STV Mission on spacecraft equivalent to ICESat power (SWaP,) and splitting the laser beam requires higher laser pulse energy.

ranging lidar↗

X-Ray Polarization of the Eastern Lobe of SS 433

IXPE is the first satellite mission dedicated to X-ray polarimetry in the 2–8 keV band. It contains three telescopes, each with a gas-pixel detector sensitive to linear X-ray polarization. IXPE enables imaging X-ray polarimetry of extended sources with an angular resolution of ~30ʺ over a 12ʹ diameter field of view.

x-ray polarimetry, black holes, jets↗

Characterization of Pixelated Cadmium-Zinc-Telluride Detectors for Astrophysical Applications

Comparisons of charge sharing and charge loss measurements between two pixelated Cadmium-Zinc-Telluride (CdZnTe) detectors are discussed. These properties along with the detector geometry help to define the limiting energy resolution and spatial resolution of the detector in question. The first detector consists of a 1-mm-thick piece of CdZnTe sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). Signal readout is via discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). This crystal is bonded to a custom-built readout chip (ASIC) providing all front-end electronics to each of the 256 independent pixels. These detectors act as precursors to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation.

Gaskin, Jessica↗

Development of Tiled Imaging CZT Detectors for Sensitive Wide-Field Hard X-Ray Surveys to EXIST

Motivated by the proposed EXIST mission, a "medium-class" space observatory to survey black holes and the Early Universe proposed to the 2010 NAS/NRC Astronomy and Astrophysics Decadal Survey, we have developed the first "large" area 256 sq cm close-tiled (0.6 mm gaps) hard X-ray (20-600 keV) imaging detector employing pixelated (2.5 mm) CdZnTe (CZT) detectors, each 2 x 2 x 0.5 cubic cm. We summarize the design, development and operation of this detector array (8 x 8 CZTs) and its performance as the imager for a coded aperture telescope on a high altitude (40 km) balloon flight in October. 2009, as the ProtoEX1STl payload. We then outline our current development of a second-generation imager, ProtcEXIST2. with 0.6 mm pixels on a 32 x 32 array on each CZT, and how it will lead to the ultimate imaging system needed for EXIST. Other applications of this technology will also be mentioned.

Grindlay, J.↗

A high resolution spectrometer for EUV/FUV wavelengths

The most efficient of the various configurations considered for a high-resolution spaceborne spectrometer for point-source astronomy in the 400-1200-A wavelength region which will fit within an envelope defined by the projected Spartan space platform is a multiple Rowland circle spectrograph, with each of four toroidal gratings respectively intercepting a fraction of the primary mirror beam. Each spectrometer can accept a rather slowly diverging beam, reducing grating aberrations, without further efficiency loss due to additional reflections or magnification. The line densities, detector size, pixel size, etc., of the detector for this instrument are dependent on the drift rate of the space platform; a design optimized for an uncorrected 4-arcsec drift is presented.

Hurwitz, Mark↗

Performance of the Zero Degree Detector

The Zero Degree Detector (ZDD) is a large area pixelated silicon detector that measures secondary particle angular distributions from heavy ion interactions. The ZDD is part of the instrumentation being used in an ongoing measurement program to measure fragmentation cross-sections of heavy nuclei and evaluate the relative effectives of novel materials for spacecraft shielding. The initial performance of the ZDD has been assessed using the primary heavy ions measured. We report here on the ZDD's design, capabilities and signal calibration using heavy ions.

Christl, Mark J.↗

Computational Ghost Imaging for Remote Sensing

This work relates to the generic problem of remote active imaging; that is, a source illuminates a target of interest and a receiver collects the scattered light off the target to obtain an image. Conventional imaging systems consist of an imaging lens and a high-resolution detector array [e.g., a CCD (charge coupled device) array] to register the image. However, conventional imaging systems for remote sensing require high-quality optics and need to support large detector arrays and associated electronics. This results in suboptimal size, weight, and power consumption. Computational ghost imaging (CGI) is a computational alternative to this traditional imaging concept that has a very simple receiver structure. In CGI, the transmitter illuminates the target with a modulated light source. A single-pixel (bucket) detector collects the scattered light. Then, via computation (i.e., postprocessing), the receiver can reconstruct the image using the knowledge of the modulation that was projected onto the target by the transmitter. This way, one can construct a very simple receiver that, in principle, requires no lens to image a target. Ghost imaging is a transverse imaging modality that has been receiving much attention owing to a rich interconnection of novel physical characteristics and novel signal processing algorithms suitable for active computational imaging. The original ghost imaging experiments consisted of two correlated optical beams traversing distinct paths and impinging on two spatially-separated photodetectors: one beam interacts with the target and then illuminates on a single-pixel (bucket) detector that provides no spatial resolution, whereas the other beam traverses an independent path and impinges on a high-resolution camera without any interaction with the target. The term ghost imaging was coined soon after the initial experiments were reported, to emphasize the fact that by cross-correlating two photocurrents, one generates an image of the target. In CGI, the measurement obtained from the reference arm (with the high-resolution detector) is replaced by a computational derivation of the measurement-plane intensity profile of the reference-arm beam. The algorithms applied to computational ghost imaging have diversified beyond simple correlation measurements, and now include modern reconstruction algorithms based on compressive sensing.

Erkmen, Baris I.↗

Charge Loss and Charge Sharing Measurements for Two Different Pixelated Cadmium-Zinc-Telluride Detectors

As part of ongoing research at Marshall Space Flight Center, Cadmium-Zinc- Telluride (CdZnTe) pixilated detectors are being developed for use at the focal plane of the High Energy Replicated Optics (HERO) telescope. HERO requires a 64x64 pixel array with a spatial resolution of around 200 microns (with a 6m focal length) and high energy resolution (< 2% at 60keV). We are currently testing smaller arrays as a necessary first step towards this goal. In this presentation, we compare charge sharing and charge loss measurements between two devices that differ both electronically and geometrically. The first device consists of a 1-mm-thick piece of CdZnTe that is sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). The signal is read out using discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe that is sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). Instead of using discrete preamplifiers, the crystal is bonded to an ASIC that provides all of the front-end electronics to each of the 256 pixels. what degree the bias voltage (i.e. the electric field) and hence the drift and diffusion coefficients affect our measurements. Further, we compare the measured results with simulated results and discuss to

Gaskin, Jessica↗

Photon-counting array detectors for space and ground-based studies at ultraviolet and vacuum ultraviolet /VUV/ wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric photon-counting array detectors, with formats as large as (256 x 1024)-pixels that can be operated in a windowless configuration at vacuum ultraviolet (VUV) and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. This paper describes the construction and modes of operation of (1 x 1024)-pixel and (24 x 1024)-pixel MAMA detector systems that are being built and qualified for use in sounding-rocket spectrometers for solar and stellar observations at wavelengths below 1300 A. The performance characteristics of the MAMA detectors at ultraviolet and VUV wavelengths are also described.

Timothy, J. G.↗

Order-sorting filter transmittance measured with an array detector

The simultaneous measurement of the spectrally and spatially variant transmittance of a linear variable order-sorting filter in a manner that closely resembles its conditions of actual use is described. The transmittance of a prototype order-sorting filter was measured in the 400- to 880-nm wavelength region by illuminating it with the output beam of a spectrophotometer while the filter was attached to the front of a 30 x 32 pixel silicon array detector. The filter was designed to be used in the output beam of a grating spectrometer to prevent the dispersal of higher diffracted orders onto an array detector. Areas of the filter that were spatially matched to the corresponding detector pixel column had measured peak transmittances of about 90 percent that were uniform to within +/- 1.5 percent along a given column. Transmittances for incident wavelengths shorter than the desired bandpass, corresponding to the order overlap region, were measured in the 0.003 range. Line spread function measurements made with the array detector indicated no significant beam spreading caused by inserting the filter into the beam.

Heaney, James B.↗

Geostationary Coastal and Air Pollution Events (GeoCAPE) Filter Radiometer (FR)

The GeoCAPE Filter Radiometer (FR) Study is a different instrument type than all of the previous IDL GeoCape studies. The customer primary goals are to keep mass, volume and cost to a minimum while meeting the science objectives and maximizing flight opportunities by fitting on the largest number of GEO accommodations possible. Minimize total mission costs by riding on a commercial GEO satellite. For this instrument type, the coverage rate, km 2 min, was significantly increased while reducing the nadir ground sample size to 250m. This was accomplished by analyzing a large 2d area for each integration period. The field of view will be imaged on a 4k x 4k detector array of 15 micrometer pixels. Each ground pixel is spread over 2 x 2 detector pixels so the instantaneous field of view (IFOV) is 2048 X 2048 ground pixels. The baseline is, for each field of view 50 sequential snapshot images are taken, each with a different filter, before indexing the scan mirror to the next IFOV. A delta would be to add additional filters.

Geo Cape↗

Characterization of a 2-mm thick, 16x16 Cadmium-Zinc-Telluride Pixel Array

The detector under study is a 2-mm-thick, 16x16 Cadmium-Zinc-Telluride pixel array with a pixel pitch of 300 microns and inter-pixel gap of 50 microns. This detector is a precursor to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation. In addition, we discuss electric field modeling for this specific detector geometry and the role this mapping will play in terms of charge sharing and charge loss in the detector.

Gaskin, Jessica↗