Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma environments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SelenITA: A Dual Point Lunar Mission to Characterize the Near Surface Dust and Electromagnetic Plasma Environment

SelenITA is a dual CubeSat mission that will provide the first multi-point dust, plasma, and magnetic field measurements in lunar orbit. This mission will advance the understanding of the electromagnetic space environment at the Moon in support of the Artemis program, exploration, and the geosciences. Here we present the science rationale motivating the mission. The candidate mission science objectives include: (1) constrain the origins of crustal magnetic fields; (2) determine the nature of plasma interactions with crustal magnetic fields; (3) characterize plasma waves and turbulence at the Moon; (4) characterize the lunar surface electric potential in varying plasma environments; (5) constrain the composition, thermal state, and structure of the lunar upper mantle and crust; (6) characterize the ionizing radiation in lunar orbit; and lastly, (7) determine the density of the dust exosphere as a function of latitude, longitude, and altitude, including the lunar polar space environment. The measurement requirements include simultaneous two-point observations of the 3-component vector magnetic field, plasma distribution (flux, energy, density, temperature), and single-point observations of energetic particles (protons, electrons, gamma rays), and dust. These measurements are important because it helps us understand how future astronauts, robots, and space hardware will live and work on the lunar surface.

space weather↗

Io and its plasma environment

The interaction of Io with its plasma torus and the Jovian magnetic field is described and examined in the context of several currently popular models. Three specific matters are addressed. First, features implied by sub-Alfvenic flow which must be common to all models are discussed. Next, the magnetic signature observed near Io by the Goddard Space Flight Center Voyager 1 magnetometer is examined and it is pointed out that the preliminary estimate of 5,000,000 A current may be an overestimate. Good fits are obtained with alternative current distributions which yield currents as small as 700,000 A through Io. The best fits are obtained for an Alfven Mach number of 0.15, but good fits are also found for Alfven Mach numbers between 0.1 and 0.25. Lastly, the crucial role of charged particle data for probing the near Io interaction is pointed out. Published data from the low energy charged particle (LECP) detector are made to suggest that Io has an intrinsic magnetic field of magnitude comparable with earlier estimates. Predictions are made which can test this picture as further data become available.

Southwood, D. J.↗

Large structure current collection in plasma environments

The floating potential, relative to the space plasma, of large satellites proposed for future missions is an important factor in the current balance between the plasma particle collection of biased surfaces and exposed conductors. To solve this balance, a knowledge of the plasma current collection processes is required. One of the unknowns in these relationships is the current collection of large areas of conducting surfaces. Only limited experimental data is available on this collection process. Data from one of the few available tests is used herein to verify the applicability of a plasma collection model for large surfaces. The model is then applied to determine the floating potential of the NASA Space Station.

Stevens, N. John↗

Study of plasma environments for the integrated Space Station electromagnetic analysis system

The final report includes an analysis of various plasma effects on the electromagnetic environment of the Space Station Freedom. Effects of arcing are presented. Concerns of control of arcing by a plasma contactor are highlighted. Generation of waves by contaminant ions are studied and amplitude levels of the waves are estimated. Generation of electromagnetic waves by currents in the structure of the space station, driven by motional EMF, is analyzed and the radiation level is estimated.

Singh, Nagendra↗

Investigation of Lunar Regolith Reduction via Hydrogen Plasma in Different Plasma Environments

The team at NASA KSC explored the use of hydrogen plasma as a reducing agent for Lunar regolith simulant in order to prove the viability of oxygen extraction from oxides. The focus of this work was to investigate the hydrogen ion production of different plasma power sources. An optimization trade study was completed by maximizing the production of the hydrogen ion and comparing the amount produced to the energy consumed. Hydrogen ion production was determined via residual gas analysis and a rough calibration using injected water. The hydrogen ions reduce the oxides present in the Lunar regolith, forming an OH molecule, which can further react with the hydrogen environment to form water vapor. This water vapor can then be measured through a residual gas analysis. Through this study, it was found that a direct current (DC) glow discharge operating at approximately 1 torr in a hydrogen environment produced the largest amount of reduced regolith when compared with a nanosecond pulsed system and alternating current (AC) source. Radiofrequency devices beyond AC were not studied in this work. Although the DC source performed the best here, limitations in design and experiment setup/scalability may lead to the selection of an alternative plasma power source in the future.

Kenneth Engeling↗

Modelling the Neutral Atmosphere and Plasma Environment of Saturn

The first year of this contract has resulted in two publications with the P.I. and co-I Jurac as lead authors and two publications where these team members are co-authors. These papers discuss modeling work undertaken in preparation for Cassini; the goal was to summarize our current best knowledge of the ion and neutrals sources and distributions. One of the major goals of this project is to improve models of the plasma and neutral environment near Saturn. The paper "A self-consistent model of plasma and neutrals at Saturn: Neutral cloud morphology" [Jurac and Richardson, 20051 presents results on the neutral clouds near Saturn using a model which for the first times treats the ions and neutrals self-consistently. We also for the first time include a directly sputtered H source. The Voyager and HST observations are used as model constraints. The neutral source is adjusted to give a good match to the HST observations of OH. For this initial run the ion parameters from Richardson et al. are used; charge exchange with ions is a major neutral loss process. The neutral profile derived from the model is then used in a model of plasma transport and chemistry (with the plasma diffusion rate the only free parameter). This model gives new values of the ion composition which are then fed back into the neutral model. This iteration continues until the values converge.

Richardson, John D.↗

Electromagnetic Radiation in the Plasma Environment Around the Shuttle

As part of the SAMPIE (The Solar Array Module Plasma Interaction Experiment) program, the Langmuir probe (LP) was employed to measure plasma characteristics during the flight STS-62. The whole set of data could be divided into two parts: (1) low frequency sweeps to determine voltage-current characteristics and to find electron temperature and number density; (2) high frequency turbulence (HFT dwells) data caused by electromagnetic noise around the shuttle. The broadband noise was observed at frequencies 250-20,000 Hz. Measurements were performed in ram conditions; thus, it seems reasonable to believe that the influence of spacecraft operations on plasma parameters was minimized. The average spectrum of fluctuations is in agreement with theoretical predictions. According to purposes of SAMPIE, the samples of solar cells were placed in the cargo bay of the shuttle, and high negative bias voltages were applied to them to initiate arcing between these cells and surrounding plasma. The arcing onset was registered by special counters, and data were obtained that included the amplitudes of current, duration of each arc, and the number of arcs per one experiment. The LP data were analyzed for two different situations: with arcing and without arcing. Electrostatic noise spectra for both situations and theoretical explanation of the observed features are presented in this report.

Vayner, Boris V.↗

Electron plasma environment at comet Grigg-Skjellerup: General observations and comparison with the environment at comet Halley

The three-dimensional electron spectrometer of the Reme plasma analyzer-complete positive ion, electron and ram negative ion measurements near comet Halley (RPA-COPERNIC) experiment aboard the Giotto spacecraft, although damaged during the comet Halley encounter in March 1986, has provided very new results during the encounter on July 10, 1992, with the weakly active comet Grigg-Skjellerup (G-S). The main characteristic features of the highly structured interaction region extending from approximately 26,500 km inbound to approximately 37,200 km outbound are presented. These results are compared to the results obtained by the same instrument during the Giotto comet Halley fly-by. Despite the large difference in the size of the interaction regions (approximately 60,000 km for G-S, approximately 2000,000 km for Halley) due to 2 orders of magnitude difference in cometary neutral gas production rate, there are striking similarities in the solar wind interactions with the two comets.

Reme, H.↗

Low Frequency Waves in the Plasma Environment Around the Shuttle

As a part of the SAMPIE (The Solar Array Module Plasma Interaction Experiment) program, the Langmuir probe (LP) was employed to measure plasma characteristics during the flight of STS-62. The whole set of data could be divided into two parts: (1) low frequency sweeps to determine voltage-current characteristics and to find the electron temperature and number density; (2) high frequency turbulence (HFT) data caused by electromagnetic noise around the Shuttle. Broadband noise was observed at 250-20,000 Hz frequencies. Measurements were performed in ram conditions; thus, it seems reasonable to believe that the influence of spacecraft operations on plasma parameters was minimized. It is shown that ion acoustic waves were observed, and two kinds of instabilities are suggested for explanation of the origin of these waves. According to the purposes of SAMPIE, samples of solar cells were placed in the cargo bay of the Shuttle, and high negative bias voltages were applied to them to initiate arcing between these cells and the surrounding plasma. The arcing onset was registered by special counters, and data were obtained that included the amplitudes of current, duration of each arc, and the number of arcs per one experiment. The LP data were analyzed for two different situations: with arcing and without arcing. Electrostatic noise spectra for both situations and a theoretical explanation of the observed features are presented in this paper.

Vayner, Boris V.↗

The integrated miniaturized electrostatic analyzer: A space plasma environment sensor

The integrated Miniaturized Electrostatic Analyzer (iMESA) was a satellite-based ionospheric sensor that operated on NASA’s Space Test Program Satellite (STPSat-3) from December 2013 to July 2019. The instrument’s scientific objective was to (1) measure the plasma density in low Earth orbit, (2) measure the plasma temperature in low Earth orbit, and (3) quantify the spacecraft potential with respect to the ambient plasma potential in the ionosphere. iMESA sampled the ionosphere every 10 s by measuring the ion current density through the ESA as a result of the motion of the spacecraft through the plasma. Current density spectra were transmitted to the ground where they were post-processed into ion density spectra and then analyzed numerically to determine the ion density, ion temperature, and spacecraft potential. This article discusses the instrument design and simulation, the determination of a geometric factor, and data processing procedures and evaluates the final data product with regard to the mission success criteria. Here, the ion density and ion temperature captured by the iMESA instrument are on the same order and range as the values predicted in the literature. The spacecraft potential was also quantified. The conclusion after the evaluation of the instrument’s data product is that the scientific mission is successful on all three points.

47 OTHER INSTRUMENTATION↗

Electrostatic Noise in the Plasma Environment Around the Shuttle

The Langmuir probe flown as part of the Solar Array Module Plasma Interactions Experiment (SAMPIE) package aboard the space shuttle flight STS-62 was used to determine plasma potential fluctuations in the vicinity of the shuttle. The broadband noise was observed at frequencies 250 - 20,000 Hz. Measurements were performed in ram conditions; thus, it seems reasonable to believe that the influence of spacecraft operations on plasma parameters was absolutely negligible. The average spectrum of fluctuations is in agreement with theoretical predictions. The influence on the observed spectra of arcing generated by high negative bias voltages applied to solar cell samples is briefly discussed.

Vayner, Boris V.↗

The simulation of the geosynchronous Earth orbit plasma environment in Chamber A: An assessment of possible experimental investigations

The possible use of Chamber A for the replication or simulation of space plasma physics processes which occur in the geosynchronous Earth orbit (GEO) environment is considered. It is shown that replication is not possible and that scaling of the environmental conditions is required for study of the important instability processes. Rules for such experimental scaling are given. At the present time, it does not appear technologically feasible to satisfy these requirements in Chamber A. It is, however, possible to study and qualitatively evaluate the problem of vehicle charging at GEO. In particular, Chamber A is sufficiently large that a complete operational spacecraft could be irradiated by beams and charged to high potentials. Such testing would contribute to the assessment of the operational malfunctions expected at GEO and their possible correction. However, because of the many tabulated limitations in such a testing programs, its direct relevance to conditions expected in the geo environment remains questionable.

Bernstein, W.↗

A global analysis of the electrodynamic interactions between a space station and the ionospheric plasma environment

A general analysis of the electrodynamic interactions between a space station with two biased platforms and the ionospheric plasma is presented. This problem can be separated into a far-field problem, concerned with the electromagnetic interference surrounding the entire space station, and a near-field problem, concentrated on the interactions in the vicinity of the biased platforms. The far-field problem is solved by application of plasma fluid theory. The space station will generate a radiation field composed mainly of the Alfven waves. This far-field radiation depends on the details of the near-field current collection. Computer particle simulations were performed in the near-field of the biased platform to study the plasma flow field, the sheath structure and the current collection. Approximate analytical solutions to the near-field are also obtained. The far-field and near-field solutions are coupled to provide a global description of the electrodynamic interactions.

Wang, J.↗

Charge-exchange plasma environment for an ion drive spacecraft

A model was reviewed which describes the propagation of the mercury charge-exchange plasma and extended to describe the flow of the molybdenum component of the charge-exchange plasma. The uncertainties in the models for various conditions are discussed. Such topics as current drain to the solar array, charge-exchange plasma material deposition, and the effects of space plasma on the charge-exchange plasma propagation are addressed.

Kaufman, H. R.↗

Effects of Kinetic Processes in Shaping Io's Global Plasma Environment: A 3D Hybrid Model

The global dynamics of the ionized and neutral components in the environment of Io plays an important role in the interaction of Jupiter's corotating magnetospheric plasma with Io. The stationary simulation of this problem was done in the MHD and the electrodynamics approaches. One of the main significant results from the simplified two-fluid model simulations was a production of the structure of the double-peak in the magnetic field signature of the I0 flyby that could not be explained by standard MHD models. In this paper, we develop a method of kinetic ion simulation. This method employs the fluid description for electrons and neutrals whereas for ions multilevel, drift-kinetic and particle, approaches are used. We also take into account charge-exchange and photoionization processes. Our model provides much more accurate description for ion dynamics and allows us to take into account the realistic anisotropic ion distribution that cannot be done in fluid simulations. The first results of such simulation of the dynamics of ions in the Io's environment are discussed in this paper.

Lipatov, Alexander S.↗

Effects of Kinetic Processes in Shaping Io's Global Plasma Environment: A 3D Hybrid Model

The global dynamics of the ionized and neutral gases in the environment of Io plays an important role in the interaction of Jupiter s corotating magnetospheric plasma with Io. Stationary simulations of this problem have already been done using the magnetohydrodynamics (MHD) and the electrodynamics approaches. One of the major results of recent simplified two-fluid model simulations [Saur, J., Neubauer, F.M., Strobel, D.F., Summers, M.E., 2002. J. Geophys. Res. 107 (SMP5), 1-18] was the production of the structure of the double-peak in the magnetic field signature of the Io flyby. These could not be explained before by standard MHD models. In this paper, we present a hybrid simulation for Io with kinetic ions and fluid electrons. This method employs a fluid description for electrons and neutrals, whereas for ions a particle approach is used. We also take into account charge-exchange and photoionization processes and solve self-consistently for electric and magnetic fields. Our model may provide a much more accurate description for the ion dynamics than previous approaches and allows us to account for the realistic anisotropic ion velocity distribution that cannot be done in fluid simulations with isotropic temperatures. The first results of such a simulation of the dynamics of ions in Io s environment are discussed in this paper. Comparison with the Galileo IO flyby results shows that this approach provides an accurate physical basis for the interaction and can therefore naturally reproduce all the observed salient features.

Lipatov, Alexander S.↗

Operating in the space plasma environment: A spacecraft charging study of the Solar X-ray Imager

This study presents the results of a spacecraft charging effects protection study conducted on the Solar X-ray Imager (SXI). The SXI is being developed by NASA Marshall Space Flight Center for NOAA's Space Environment Laboratory, and will be used to aid in forecasting energetic particle events and geomagnetic storms. Images will provide information on the intensity and location of solar flares, coronal mass ejections, and high speed solar streams. The SXI will be flown on a next-generation GOES sometime in the mid to late 1990's. Charging due to the encounter with a worst-case magnetic substorm environment is modeled using the NASCAP/GEO computer code. Charging levels of exterior surfaces and the floating potential of the spacecraft relative to plasma are determined as a function of spacecraft design, operational configuration, and orbital conditions. Areas where large surface voltage gradients exist on or near the SXI are identified as possible arc-discharge sites. Results of the charging analysis are then used to develop design recommendations that will limit the effects of spacecraft charging on the SXI operation.

Herr, Joel L.↗