Search NASA⌕ Search

SEARCH · Search NASA

Results for “plif”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Characterization of Reactant Refill and Detonation Wave Dynamics in a GOx/Natural-gas RDRE Using Simultaneous High Repetition-Rate OH-PLIF and Chemiluminescence

The potential application of rotating detonation engines (RDEs) in rocket combustors hinges on a fundamental understanding of detonation wave structure and injector characteristics with fuel and oxidizer compositions relevant in rocket systems. Simultaneous 300 kHz-rate broadband OH* chemiluminescence and OH-PLIF imaging is employed in a fully optically accessible Natural Gas-GOx rotating detonation rocket engine (RDRE) to visualize reactant refill dynamics and detonation wave structure. A custom-built KTP-type optical parametric oscillator (OPO) is coupled with a nanosecond high-repetition-rate burst-mode laser to output284 nm light and target excitation of the Q1(9) transition in the OH radical. Significant deflagrative burning is observed throughout the chamber as a consequence of the oxygen-rich environment. Trailing Azimuthal Reflected Shock Combustion (ARSC) system, similar to those in a H2-air RDE are observed, burning unburned reactants in the region immediately following the primary detonation wave. Contact burning, as indicated in this study, does not seem to be a primary loss mechanism. The simultaneous measurement of OH and OH* show that axial locations exist in the refill process where OH radicals are present, and produced due to shear layer induced deflagration, however, these zones do not produce excited state OH*. While a deeper understanding of the underlying physics in RDRE systems requires further investigation, this work highlights a first-of-its-kind visualization of the turbulent combustion product field and reactant refill characteristics in this highly unsteady environment.

Propulsion↗

Time-Resolved OH-PLIF Assessment of Deflagrations Levels in a CH4-O2 Rotating Detonation Rocket Combustor

The parasitic loss incurred by deflagrative pre-burning is considered to be one of the key challenges to the effective implementation of rotating detonation engine (RDE) systems. Thus far, there have been relatively limited high fidelity, spatio-temporally resolved measurements of the pre-burning process as a function of the reactant conditions and composition within an RDE. In this work, simultaneous high-repetition-rate broadband OH* chemiluminescence and OH planar laser-induced fluorescence (PLIF) imaging are employed to investigate deflagrative burning dynamics in a fully optically accessible CH4-O2 RDE as compared to a H2-air systems under the same conditions. A custom-built optical parametric oscillator (OPO) is coupled with a high-repetition-rate burst-mode laser to generate the 284 nm source for the excitation of the Q1(9) transition of the OH radical. Significant deflagrative burning is observed throughout the chamber as a consequence of the oxygen-rich environment. Trailing wave systems that consume unburned reactants in the region immediately following the primary detonation wave are observed. The formation of a product gas recirculation zone that entrains and combusts incoming reactants is observed, and quantitative analysis is performed to gain valuable insight into deflagration characteristics. At an oxidizer mass flux of Gox ≈ 350kg/m2/s, it is found that the levels of pre-wave burning in CH4-O2 are a factor of ∼2-3 times higher than in H2-air in the region directly ahead of the detonation wave at a global equivalence ratio Φ ≈ 1.0. This study highlights the key roles of ignition delay and turbulent mixing of the combustion product and reactant fields on the levels of pre-burning and establishes a methodology for further investigation, such as for the effects of various RDE inlet configurations.

Propulsion↗

Temporal evolution of scalar modes in Richtmyer–Meshkov instability of inclined interface using high-speed PIV and PLIF measurements at 60 kHz

Abstract The current work presents simultaneous, high-speed measurements at 60,000 fields per second of velocity and mole fraction using particle image velocimetry (PIV) and planar laser induced acetone-fluorescence in a Richtmyer–Meshkov instability of an inclined interface (Atwood number, At = 0.22). Specifically, around 2 ms of temporal evolution of the vortex structures and their associated scalar modes immediately following the interface-reshock interaction is presented. Two initial interface conditions are discussed—(a) a sharp, inclined ‘single mode’ interface and (b) a ‘multi-mode’ interface where small perturbations are imposed on the single mode case. A 2D wavelet decomposition of the scalar flow field shows a highly intermittent distribution of small-scale variance throughout the interface even at late times. These are correlated strongly with the vortex structures and local turbulence intensity, where each small-scale scalar mode is sandwiched between two co-rotating vortex structures. This indicates that the interstitial regions between the vortices are significant hotspots of entrainment, which is then dispersed by the induced, counter-flow velocity fields. The multimode case demonstrates similar organization at large scales, while the scalar field is much more homogeneous at smaller scales. These observations highlight the importance of capturing the early time vortex evolution to accurately estimate any late time intermittency, especially where deposition of intense vorticity on sharp interfaces is present.

Engineering↗

PLIF Temperature and Velocity Distributions in Laminar Hypersonic Flat-plate Flow

Rotational temperature and velocity distributions have been measured across a hypersonic laminar flat-plate boundary layer, using planar laser-induced fluorescence. The measurements are compared to a finite-volume computation and a first-order boundary layer computation, assuming local similarity. Both computations produced similar temperature distributions and nearly identical velocity distributions. The disagreement between calculations is ascribed to the similarity solution not accounting for leading-edge displacement effects. The velocity measurements agreed to within the measurement uncertainty of 2 % with both calculated distributions. The peak measured temperature was 200 K lower than the computed values. This discrepancy is tentatively ascribed to vibrational relaxation in the boundary layer.

OByrne, S.↗

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

A nonintrusive laser-based measurement system has been applied for the first time in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. Planar laser-induced fluorescence of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements. Results are presented at selected facility run conditions, including some in simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of 0.5km/s were measured.

Inman, Jennifer A.↗

Experimental Assessment and Enhancement of Planar Laser-Induced Fluorescence Measurements of Nitric Oxide in an Inverse Diffusion Flame

We have experimentally assessed the quantitative nature of planar laser-induced fluorescence (PLIF) measurements of NO concentration in a unique atmospheric pressure, laminar, axial inverse diffusion flame (IDF). The PLIF measurements were assessed relative to a two-dimensional array of separate laser saturated fluorescence (LSF) measurements. We demonstrated and evaluated several experimentally-based procedures for enhancing the quantitative nature of PLIF concentration images. Because these experimentally-based PLIF correction schemes require only the ability to make PLIF and LSF measurements, they produce a more broadly applicable PLIF diagnostic compared to numerically-based correction schemes. We experimentally assessed the influence of interferences on both narrow-band and broad-band fluorescence measurements at atmospheric and high pressures. Optimum excitation and detection schemes were determined for the LSF and PLIF measurements. Single-input and multiple-input, experimentally-based PLIF enhancement procedures were developed for application in test environments with both negligible and significant quench-dependent error gradients. Each experimentally-based procedure provides an enhancement of approximately 50% in the quantitative nature of the PLIF measurements, and results in concentration images nominally as quantitative as LSF point measurements. These correction procedures can be applied to other species, including radicals, for which no experimental data are available from which to implement numerically-based PLIF enhancement procedures.

Partridge, William P.↗

A Comparison of NO Laser-Induced Fluorescence Models at Conditions Relevant to Supersonic and Hypersonic Flows

Planar laser-induced fluorescence (PLIF) of the nitric oxide (NO) molecule has been widely used in wind tunnel facilities for flow visualization, velocity, and temperature measurements. The experimental PLIF measurements are often compared with synthetic PLIF images using computationally derived temperatures, pressures, velocities, and species mole fractions. This approach is commonly referred to as computational flow imaging (CFI). In the present work, we compare signal intensity from PLIF models with experimental PLIF measurements obtained within a low pressure gas cell system at pressures and NO mole fractions relevant to supersonic and hypersonic flowfields. Experimental measurements were compared to several different laser induced-fluorescence models reported in the literature including LIFBASE, LINUS, and a NASA two-level model. The experimental measurements agreed well with all of the models at lower pressures and lower NO mole fractions; the fluorescence there is linear with both of these parameters. However, at higher pressures and mole fractions, the signal becomes nonlinear with respect to these parameters as self-quenching limits the signal and absorption further limits the signal. In fact, for the experimental path length of the experiment, the combination of high pressure and high NO mole fraction causes the experimental results to deviate significantly from the predicted results that neglect absorption of the incident laser sheet. The LINUS model, which allows absorption to be calculated, provided results that agreed better with the experimental measurements. Since supersonic and hypersonic flowfields may contain a region of the flow with high pressures and measurements in large-scale facilities often include a long path length, neglecting absorption may have a significantly negative effect on the CFI comparison to experimental PLIF images. As a result, PLIF models that account for absorption should be included in computational flow imaging approaches for laser induced fluorescence.

laser-induced fluorescence↗

Multi-Dimensional Measurements of Combustion Species in Flame Tube and Sector Gas Turbine Combustors

The higher temperature and pressure cycles of future aviation gas turbine combustors challenge designers to produce combustors that minimize their environmental impact while maintaining high operation efficiency. The development of low emissions combustors includes the reduction of unburned hydrocarbons, smoke, and particulates, as well as the reduction of oxides of nitrogen (NO(x)). In order to better understand and control the mechanisms that produce emissions, tools are needed to aid the development of combustor hardware. Current methods of measuring species within gas turbine combustors use extractive sampling of combustion gases to determine major species concentrations and to infer the bulk flame temperature. These methods cannot be used to measure unstable combustion products and have poor spatial and temporal resolution. The intrusive nature of gas sampling may also disturb the flow structure within a combustor. Planar laser-induced fluorescence (PLIF) is an optical technique for the measurement of combustion species. In addition to its non-intrusive nature, PLIF offers these advantages over gas sampling: high spatial resolution, high temporal resolution, the ability to measure unstable species, and the potential to measure combustion temperature. This thesis considers PLIF for in-situ visualization of combustion species as a tool for the design and evaluation of gas turbine combustor subcomponents. This work constitutes the first application of PLIF to the severe environment found in liquid-fueled, aviation gas turbine combustors. Technical and applied challenges are discussed. PLIF of OH was used to observe the flame structure within the post flame zone of a flame tube combustor, and within the flame zone of a sector combustor, for a variety of fuel injector configurations. OH was selected for measurement because it is a major combustion intermediate, playing a key role in the chemistry of combustion, and because its presence within the flame zone can serve as a qualitative marker of flame temperature. All images were taken in the environment of actual engines during flight, using actual jet fuel. The results of the PLIF study led directly to the modification of a fuel injector.

Hicks, Yolanda Royce↗

Quantitative Measurements of Nitric Oxide Concentration in High-Pressure, Swirl-Stabilized Spray Flames

Lean direct-injection (LDI) spray flames offer the possibility of reducing NO(sub x) emissions from gas turbines by rapid mixing of the liquid fuel and air so as to drive the flame structure toward partially-premixed conditions. We consider the technical approaches required to utilize laser-induced fluorescence methods for quantitatively measuring NO concentrations in high-pressure LDI spray flames. In the progression from atmospheric to high-pressure measurements, the LIF method requires a shift from the saturated to the linear regime of fluorescence measurements. As such, we discuss quantitative, spatially resolved laser-saturated fluorescence (LSF), linear laser-induced fluorescence (LIF), and planar laser-induced fluorescence (PLIF) measurements of NO concentration in LDI spray flames. Spatially-resolved LIF measurements of NO concentration (ppm) are reported for preheated, LDI spray flames at pressures of two to five atmospheres. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q(sub 2)(26.5) transition of the gamma(0,0) band. Detection is performed in a two nanometer region centered on the gamma(0,1) band. A complete scheme is developed by which quantitative NO concentrations in high-pressure LDI spray flames can be measured by applying linear LIF. NO is doped into the reactants and convected through the flame with no apparent destruction, thus allowing a NO fluorescence calibration to be taken inside the flame environment. The in-situ calibration scheme is validated by comparisons to a reference flame. Quantitative NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors. Moreover, parametric studies are provided for variations in pressure, air-preheat temperature, and equivalence ratio. Similar parametric studies are performed for lean, premixed-prevaporized flames to permit comparisons to those for LDI flames. Finally, PLIF is expanded to high pressure in an effort to quantify the detected fluorescence image for LDI flames. Success is achieved by correcting the PLIF calibration via a single-point LIF measurement. This procedure removes the influence of any preferential background that occurs in the PLIF detection window. In general, both the LIF and PLIF measurements verify that the LDI strategy could be used to reduce NO(sub x) emissions in future gas turbine combustors.

Cooper, Clayton S.↗

Comparison of MSL RCS Jet Computations With Flow Visualization and Velocimetry

Numerical predictions of the Mars Science Laboratory (MSL) reaction control system (RCS) jets interacting with a Mach 10 hypersonic flow are compared to experimental nitric oxide (NO) planar laser-induced fluorescence (PLIF) data. The steady Reynolds Averaged Navier Stokes (RANS) equations using the Baldwin-Barth one-equation turbulence model were solved using the OVERFLOW code. The experimental PLIF data used for comparison consists of qualitative two-dimensional visualization images, qualitative reconstructed three-dimensional flow structures, and quantitative two-dimensional distributions of streamwise velocity. Through modeling of the PLIF signal equation, computational flow images (CFI) were produced and directly compared to the qualitative PLIF data. Post processing of the experimental and simulation data enabled the jet trajectory to be extracted for a more quantitative comparison. The two-dimensional velocity fields were reconstructed through interpolation of a series of single-component velocity profiles. Each distribution of single-component velocity was obtained using molecular tagging velocimetry (MTV). After validating the numerical model, the numerical solution was further examined to gain insight into hypersonic jet-in-crossflow interaction. Future NO-PLIF experiments are proposed based on this analysis.

Johansen, Craig T.↗

Visualization of post-detonation fireball flowfields and comparison to CFD modeling

Visualization of flow structures within post-detonation fireballs has been performed for benchmark validation of numerical simulations. Custom pressed PETN explosives with a 12-mm diameter hemispherical form factor were used to produce a spherically symmetric post-detonation flow with low soot yield. Hydroxyl-radical planar laser induce fluorescence (OH-PLIF) was employed to visualize the structure ranging from approximately 10 μs to 35 μs after shock breakout from the explosive pellet. Fireball simulations were performed using the HyBurn Computational Fluid Dynamics (CFD) package. Experimental OH-PLIF results were compared to synthetic OH-PLIF from post-processing of CFD simulations. From the comparison of experimental and synthetic OH-PLIF images, CFD is shown to replicate much of the flow structure observed in the experiments, revealing potential differences in turbulent length scales and OH kinetics. Furthermore, results provide significant advancement in experimental resolution of these harsh turbulent combustion environments and validate physical models thereof.

Detonator↗