Search NASA⌕ Search

SEARCH · Search NASA

Results for “plug load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Workplace Charge Management with Aggregated Building Loads

This paper describes a workplace charge management system developed to control plug-in electric vehicle charging stations based on aggregated building loads. A system to collect information from drivers was also developed for better charge management performance since the present AC charging station standard does not provide battery state of charge information. First, simulations with uncontrolled charging data were conducted to investigate several scenarios and control methods, and then one method with the most power curtailment during peak load was selected for verification tests. This paper illustrates load reduction test results for 36 charging stations and real-time campus net load data.

25 ENERGY STORAGE↗

Process Improvements to Biomass Pretreatment of Fuels and Chemicals

MBI, a 501c(3) company focusing on de-risking and scaling up bio-based technologies, has teamed with Michigan State University and the Idaho National Laboratory to develop and demonstrate process improvements to the ammonia fiber expansion (AFEX) pretreatment process. The logistical hurdles of biomass handling are well known, and the regional depot concept - in which small, distributed bioprocessing operations collect, preprocess, and densify biomass before shipping to a centralized refinery - is a promising alternative to centralized collection. AFEXTM (AFEX is a trademark of MBI) has unique features among pretreatments that would make it desirable as a pretreatment prior to densification at the depot scale. MBI has developed a novel design, using a packed bed reactor for the AFEX process that can be scaled down economically to the depot scale at a lower capital cost as compared to the traditional design (Pandia type reactor). Thus, the purpose of this project was to develop, scale-up, demonstrate, and improve this novel design The key challenges are the recovery of ammonia, consistent and complete pretreatment performance, and the overall throughput of the reactor. In this project an engineering scale packed bed AFEX system with 1-ton per day capacity was installed at MBI’s building. The system has been operational since mid-2013. During that time, MBI has demonstrated the robustness, reliability, and consistency of the process. To date, nearly 500 runs have been performed in the reactors. There have been no incidences of plugging (i.e., inability to remove ammonia from biomass after the treatment), nor has there been any instance of a major ammonia release into the atmosphere. Likewise, the sugar released via enzyme hydrolysis has remained consistent throughout these runs. Our economic model shows a 46% reduction in AFEX capital cost at the 100 ton/day scale compared to the traditional design of AFEX (Pandia type reactor). The key performance factors were demonstrated; >94% ammonia recovery, >75% sugar yields at high solid loading, and complete utilization of the sugars for ethanol production at the 2500 liter scale. Fermentation tests were performed using Zymomonas mobilis 8b and densified AFEX-treated corn stover at >20% solid loading. The obtained titer (~60g/l), productivity (2.5 g/L-h), and yield (330 L/tonne of biomass) exceeded the performance targets set out by NREL. The key findings from these efforts are: no contamination was observed, no cleanup of the sugar stream was required, and no major nutrient addition was required. Our economic model shows that using a packed bed design for the AFEX process and pelleted AFEX-treated biomass reduces the ethanol production cost by 24% when compared to using the traditional AFEX design.

09 BIOMASS FUELS↗

ANALYSIS OF DISTRIBUTION FEEDER LOSSES DUE TO ADDITION OF DISTRIBUTED PHOTOVOLTAIC GENERATORS

Distributed generators (DG) are small scale power supplying sources owned by customers or utilities and scattered throughout the power system distribution network. Distributed generation can be both renewable and non-renewable. Addition of distributed generation is primarily to increase feeder capacity and to provide peak load reduction. However, this addition comes with several impacts on the distribution feeder. Several studies have shown that addition of DG leads to reduction of feeder loss. However, most of these studies have considered lumped load and distributed load models to analyze the effects on system losses, where the dynamic variation of load due to seasonal changes is ignored. It is very important for utilities to minimize the losses under all scenarios to decrease revenue losses, promote efficient asset utilization, and therefore, increase feeder capacity. This paper will investigate an IEEE 13-node feeder populated with photovoltaic generators on detailed residential houses with water heater, Heating Ventilation and Air conditioning (HVAC) units, lights, and other plug and convenience loads. An analysis of losses for different power system components, such as transformers, underground and overhead lines, and triplex lines, will be performed. The analysis will utilize different seasons and different solar penetration levels (15%, 30%).

24 POWER TRANSMISSION AND DISTRIBUTION↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Total Cost of Ownership Reduction Using Passive Pre-Chamber Ignition in Natural Gas Engines

Spark plug durability is a factor affecting the total cost of ownership (TCO) of spark-ignited natural gas engines, with some heavy-duty platforms requiring plug replacement after only 750 hours of operation. The high ignition energy demand under lean or diluted conditions accelerates electrode wear, shortening plug life and increasing maintenance frequency. This work evaluates passive pre-chamber (PC) ignition operating at lowered spark energies as a strategy to reduce spark energy requirements and extend plug durability, thereby lowering TCO. Experiments were conducted on a medium-duty Cummins 6.7L ISB engine at 1600 RPM and 50% load under varying exhaust gas recirculation (EGR) dilution levels (0–40%). Two passive pre-chambers with 1.1 mm and 1.6 mm nozzle diameters were compared with conventional spark ignition (SI). SI was operated with a fixed coil dwell of 4 ms (~90 mJ), while the PC configuration was tested across 2–4 ms dwell times (~30–90 mJ). Cylinder pressure analysis revealed that PC ignition sustained stable combustion at significantly lower spark energies than SI, with improved combustion stability at ~30 mJ compared with SI at ~90 mJ. The PC system also extended the dilution tolerance beyond that achievable with SI, while delivering up to ~2% higher indicated thermal efficiency and reducing the COV by nearly 90% at 30% EGR. A TCO analysis was conducted to assess the economic benefit of adopting a passive PC system operating at reduced spark energies compared to SI. It was found that adopting a passive PC system could reduce TCO by approximately $11,000 per engine over a five-year operational period, primarily due to fuel savings, extended spark plug life, and reduced maintenance frequency. These projections were weighed against the additional hardware cost of the pre-chamber, yielding a rapid estimated return on investment of ~300 operating hours. Therefore, this work motivates continued research and development of passive PC technology and its commercial adoption in natural gas engines used in transportation applications.

Dhotre, Akash [University of Minnesota]↗

FTR for: Reducing plug-load electricity footprint of residential buildings through low-cost, non-intrusive sub-metering and personalized feedback technology

The project started in October 2016 and ended in December 2022. The project's principal goals and achievements were: (i) Measure real and reactive electric power consumption in ~400 apartments in multifamily settings of varying size and vintage and publish the data; data was published according to New York State's recommended 15x15 rule continuously from Jan 2019 through December 2022 (10 second time resolution); with the combination of large number of apartments, real and reactive power, as well as high time resolution (10-seconds), the dataset is first of its kind worldwide; because the dataset New York City apartment consumption pre, during, and post pandemic, it further offers unique insights into changes in residential electricity consumption during lockdowns and after modified work from home schedules. (ii) Measure effectiveness of different feedback types to prompt residents to lower their electricity consumption; achieved 11% (kWh-weighted) reduction versus baseline consumption; confirmed previous studies that social comparisons elicit above average responses; showed, for the first time, that the so called boomerang effect in power consumption feedback projects can be explained by a previously hypothesized norm-conforming "magnet effect" (rather than a non-conforming defiance effect), thus substantially advancing the research in the field. (iii) Disaggregate apartment-level consumption to appliance level; because the hardware for electricity consumption unexpectedly allowed only for 10-second time resolution (rather than the 1-second resolution we had planned on), the disaggregation algorithms we developed on sample data could not be applied to the actual field data we collected. The project has yielded high visibility, with a total of 17 publications, from peer reviewed journals, published data sets (free access), blog posts, NY Times, National Public Radio, and CNN.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Value and Technology Assessment to Enhance the Business Case for the CERTS Microgrid

The CERTS Microgrid concept is an advanced approach for enabling integration of, in principle, an unlimited quantity of distributed energy resources into the electricity grid. A key feature of a microgrid, is its ability, during a utility grid disturbance, to separate and isolate itself from the utility seamlessly with no disruption to the loads within the microgrid (including no reduction in power quality). Then, when the utility grid returns to normal, the microgrid automatically resynchronizes and reconnects itself to the grid, in an equally seamless fashion. What is unique about the CERTS Microgrid is that it can provide this technically challenging functionality without extensive (i.e., expensive) custom engineering. In addition, the design of the CERTS Microgrid also provides high system reliability and great flexibility in the placement of distributed generation within the microgrid. The CERTS Microgrid offers these functionalities at much lower costs than traditional approaches by incorporating peer-to-peer and plug-and-play concepts for each component within the Microgrid. The predecessor to the current project involved the construction of and completion of initial testing using the world's first, full-scale, inverter-based, distributed generation test bed. The project demonstrated three advanced techniques, collectively referred to as the CERTS Microgrid concept, which collectively significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques are: (1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; (2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and (3) a method for microgrid control that achieves voltage and frequency stability under both grid and islanded conditions without requiring high-speed communications. The work conducted in this phase of RD&D on the CERTS Microgrid Concept builds upon this base of technical accomplishments to prioritize, develop, and then demonstrate technology enhancements to further enhance the business case for microgrids. That is, having demonstrated the technical feasibility of microgrid functions, RD&D optimization efforts are now needed to accelerate commercial deployment. The current phase is a contribution to these efforts. This project involved seven distinct analysis, bench-, and full-scale testing tasks. The first five tasks were described in the original proposal submitted and awarded through DOE's solicitation. Two additional tasks were added to address issues that had been identified in the earlier, first phase of testing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

Simulating energy performance of buildings: a study using eQUEST and Energy Star ® portfolio manager

Commercial buildings consume significant energy in the United States and exhibit high potential for energy use reduction through retrofits. Benchmarking and energy simulation are well established tools in the industry to identify potential improvements and measure performance. Analysis to identify most sensitive retrofit parameters to energy performance can optimize investment and available energy savings. Presented study demonstrates methodology using a static model to determine sensitivity of building design and retrofit parameters with respect to energy performance. Calibrated simulation energy models (eQUEST) of two distribution centers (A, B) are presented. A fractional factorial analysis is conducted on retrofit parameters of efficiency measures targeting the highest energy consumers, and the results are benchmarked using Energy Star® Portfolio Manager. A custom Microsoft Excel® based simulation model is created to simulate occupancy levels, lighting, plug loads, and other equipment used in various spaces throughout the day. For Building A, efficient lighting was the most influential parameter for energy savings, carbon savings and benchmarking score; whereas, for Building B, HVAC efficiency was most influential for energy and demand controlled ventilation and economizers was most influential for benchmarking score. While retrofit projects can save energy and carbon emissions, variation in source-site ratios and state grid emissions, benchmarking scores may not always reflect equivalent improvement. State grid emissions factors, natural gas composition are difficult to model and hence not considered in this study. In conclusion, the synergistic analysis presented, emphasizes the importance of benchmarking and efficiency retrofits in promoting sustainable building practices to reduce energy consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

DEEP: A Database of Energy Efficiency Performance to Accelerate Energy Retrofitting of Commercial Buildings

The paper presents a method and process to establish a database of energy efficiency performance (DEEP) to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 35 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER prototype buildings. The prototype buildings represent seven building types across six vintages of constructions and 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and domestic hot water. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of an on-going project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users’ decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit. DEEP will be migrated into the DEnCity - DOE’s Energy City, which integrates large-scale energy data for multi-purpose, open, and dynamic database leveraging diverse source of existing simulation data.

Hoon Lee, Sang↗

DEEP: Database of Energy Efficiency Performance

A database of energy efficiency performance (DEEP) is a presimulated database to enable quick and accurate assessment of energy retrofit of commercial buildings. DEEP was compiled from results of about 10 million EnergyPlus simulations. DEEP provides energy savings for screening and evaluation of retrofit measures targeting the small and medium-sized office and retail buildings in California. The prototype building models are developed for a comprehensive assessment of building energy performance based on DOE commercial reference buildings and the California DEER [sic] prototype buildings. The prototype buildings represent seven building types across six vintages of constructions and 16 California climate zones. DEEP uses these prototypes to evaluate energy performance of about 100 energy conservation measures covering envelope, lighting, heating, ventilation, air conditioning, plug loads, and domestic hot war. DEEP consists the energy simulation results for individual retrofit measures as well as packages of measures to consider interactive effects between multiple measures. The large scale EnergyPlus simulations are being conducted on the super computers at the National Energy Research Scientific Computing Center (NERSC) of Lawrence Berkeley National Laboratory. The pre-simulation database is a part of the CEC PIER project to develop a web-based retrofit toolkit for small and medium-sized commercial buildings in California, which provides real-time energy retrofit feedback by querying DEEP with recommended measures, estimated energy savings and financial payback period based on users' decision criteria of maximizing energy savings, energy cost savings, carbon reduction, or payback of investment. The pre-simulated database and associated comprehensive measure analysis enhances the ability to performance assessments of retrofits to reduce energy use for small and medium buildings and business owners who typically do not have resources to conduct costly building energy audit.

Hong, Tianzhen↗

Field Evaluation of Medium-Duty Plug-in Electric Delivery Trucks

This report focuses on medium-duty electric delivery vehicles operated by Frito-Lay North America (FLNA) at its Federal Way, Washington, distribution center. The 100% electric drive system is an alternative to conventional diesel delivery trucks and reduces both energy consumption and carbon dioxide (CO2) emissions. The vehicles' drive cycles and operation are analyzed and compared to demonstrate the importance of matching specific electric vehicle (EV) technologies to the appropriate operational duty cycle. The results of this analysis show that the Smith Newton EVs demonstrated a 68% reduction in energy consumption over the data reporting period compared to the conventional diesel vehicles, as well as a 46.4% reduction in CO 2 equivalent emissions based on the local energy generation source. In addition to characterizing the in-use performance of the EVs compared to the conventional diesels, detailed facility load data were collected at the main building power feed as well as from each of the 10 EV chargers to better understand the broader implications associated with commercial EV deployment. These facility loads were incorporated into several modeling scenarios to demonstrate the potential benefits of integrating onsite renewables.

33 ADVANCED PROPULSION SYSTEMS↗

Nature and spatial distribution of sulfur species in a sulfated barium-based commercial lean NOx trap catalyst

We report observations of the nature and spatial distribution of sulfur species on a sulfated Ba-based commercial lean NO{sub x} trap (LNT) catalyst. The monolithic catalyst was sulfated in a bench flow reactor during 60/4-s NO{sub x} storage/reduction cycling to achieve a total sulfur loading of 3.4 g L{sup -1} of catalyst. Washcoat composition, structure and sulfur distribution were analyzed with electron probe microanalysis, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and temperature-programmed reduction. The most significant washcoat elements of catalytic relevance were Pt, Pd, Rh, Ba, Ce, Zr, Mg, Al, and these were present mainly in four distinct domains; Mg/Al mixed oxide with Pt, Ce; Al oxide with Rh, Pd; Ce/Zr mixed oxide with Pt, Pd, Ba (high Ba content); Ce/Zr mixed oxide with Pt, Pd, Ba (lower Ba content). Sulfur was present in the form of sulfates that decreased in concentration along the LNT axis from front to back. Barium showed the highest sulfur affinity leading to a plug-like axial progression of its sulfation. The sulfation of AI, Mg/Al, and Ce/Zr oxides was less vigorous with a more axially dispersed and less penetrating front.

02 PETROLEUM↗

An Investigation of the Applicability and Limitations of the ORNL Expanded Plug Test

The expanded plug test technique for measuring the circumferential tensile properties of irradiated nuclear fuel cladding was developed at Oak Ridge National Laboratory (ORNL) and has been used successfully in several applications. The primary advantage of this technique over other procedures is its simplicity for application in the complex hot cell environment. During the development stage, efforts were made to both qualify the technique as much as possible regarding its experimental application and to develop and validate the data reduction procedures. However, since this is a new technique, the technical community is cautious in adopting a procedure that has not been fully vetted. The purpose of this effort was to address several baseline issues regarding the applicability of the technique and the precision of the use of experimental expanded ring load-deformation data to calculate material circumferential stress-strain properties. The tests performed, in conjunction with the developed data reduction procedures, demonstrate good reliability in the prediction of ring material stress-strain behavior for several materials of widely different strengths.

tensile, nuclear fuel cladding↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility of Achieving a Zero-Net-Energy, Zero-Net-Cost Homes

A green building competition, to be known as the Energy Free Home Challenge (EFHC), is scheduled to be opened to teams around the world in 2010. This competition will encourage both design innovation and cost reduction, by requiring design entries to meet 'zero net energy' and 'zero net cost' criteria. For the purposes of this competition, a 'zero net energy' home produces at least as much energy as it purchases over the course of a year, regardless of the time and form of the energy (e.g., electricity, heat, or fuel) consumed or produced. A 'zero net cost' home is no more expensive than a traditional home of comparable size and comfort, when evaluated over the course of a 30-year mortgage. In other words, the 'green premium' must have a payback period less than 30 years, based on the value of energy saved. The overarching goal of the competition is to develop affordable, high-performance homes that can be mass-produced at a large scale, and are able to meet occupant needs in harsh climates (as can be found where the competition will be held in Illinois). This report outlines the goals of the competition, and gauges their feasibility using both modeling results and published data. To ensure that the established rules are challenging, yet reasonable, this report seeks to refine the competition goals after exploring their feasibility through case studies, cost projections, and energy modeling. The authors of this report conducted a survey of the most progressive home energy-efficiency practices expected to appear in competition design submittals. In Appendix A, a summary can be found of recent projects throughout the United States, Canada, Germany, Switzerland, Sweden and Japan, where some of the most progressive technologies have been implemented. As with past energy efficient home projects, EFHC competitors will incorporate a multitude of energy efficiency measures into their home designs. The authors believe that the cost of electricity generated by home generation technologies will continue to exceed the price of US grid electricity in almost all locations. Strategies to minimize whole-house energy demand generally involve some combination of the following measures: optimization of surface (area) to volume ratio; optimization of solar orientation; reduction of envelope loads; systems-based engineering of high efficiency HVAC components, and on-site power generation. A 'Base Case' home energy model was constructed, to enable the team to quantitatively evaluate the merits of various home energy efficiency measures. This Base Case home was designed to have an energy use profile typical of most newly constructed homes in the Champaign-Urbana, Illinois area, where the competition is scheduled to be held. The model was created with the EnergyGauge USA software package, a front-end for the DOE-2 building energy simulation tool; the home is a 2,000 square foot, two-story building with an unconditioned basement, gas heating, a gas hot-water heater, and a family of four. The model specifies the most significant details of a home that can impact its energy use, including location, insulation values, air leakage, heating/cooling systems, lighting, major appliances, hot water use, and other plug loads. EFHC contestants and judges should pay special attention to the Base Case model's defined 'service characteristics' of home amenities such as lighting and appliances. For example, a typical home refrigerator is assumed to have a built-in freezer, automatic (not manual) defrost, and an interior volume of 26 cubic feet. The Base Case home model is described in more detail in Section IV and Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗