At least 73 records · Page 4

Mounting, support, and isolation of various components of a hydrogen maser

Polytetrafluoroethylene tubing partially collapsed during assembly protects the shields from thermal expansion stress in isothermal and magnetic canisters. Thermal insulation between the shields is made from epoxy foam cast in position and cured under high temperature. Stacked mounting array supports the maser's hexapole magnet and hydrogen atom source.

Cutler, L.↗

New electrocatalysts for hydrogen-oxygen fuel cells

Platinum-silver, palladium-gold, and platinum-gold alloys serve as oxygen reduction catalysts in high-current-density cells. Catalysts were tested on polytetrafluoroethylene-bonded cathodes and a hydrogen anode at an operating cell temperature of 80 degrees C.

Cattabriga, R. A.↗

Film breakers prevent migration of aqueous potassium hydroxide in fuel cells

Electrolyte film breakers made from polytetrafluoroethylene are installed in the reactant and water vapor removal outlets of each cell and sealed by elastomers. Use of these devices in the water vapor removal cavity outlets prevents loss of KOH solution through film migration during water removal.

Hess, P. D.↗

Improved linings for integrating spheres

Sphere surface is covered with plain weave of glass fibers coated with polytetrafluoroethylene and one or two layers of magnesium oxide vapor. The resultant lining is suitable for measurement of radiation in the ultraviolet, visible, and near-infrared wavelengths, is not damage prone, and is easily cleaned.

Fergerson, P. O.↗

Filled polymers for bearings and seals used in liquid hydrogen

Filled polytrifluorochloroethylene /PTFCE/ shows better thermal stability, less creep, and higher compressive moduli than filled polytetrafluoroethylene /PTFE/. Bearing and seal materials exhibiting the best characteristics contain a high percentage of PTFCE.

Johnson, R. L.↗

Preparation of perfluoropolyether prepolymers

Fluorinated prepolymers are used to generate highly fluorinated polymers which possess most of the desirable properties of polytetrafluoroethylene, such as nonflammability and high corrosion resistance, while retaining good low temperature flexibility.

Rochow, S. E.↗

Apollo 13 Mission: Cryogenic Oxygen Tank 2 Anomaly Report

There were two investigative aspects associated with the loss of the cryogenic oxygen tank pressure during the Apollo 13 flight. First, what was the cause of the flight failure of cryogenic oxygen tank 2. Second, what possible contributing factors during the ground history of the tank could have led to the ultimate failure in flight. The first flight indication of a problem occurred when the quantity measurement in the tank went full scale about 9 hours before the incident. This condition in itself could not have contributed to ignition in the tank, since the energy in the circuit is restricted to about 7 milli-joules. Data from the electrical system provided the second indication of a problem when the fans in tank 2 were activated to reduce any stratification which might have been present in the supercritical oxygen in the tank. Several short-circuits were detected and have been isolated to the fan circuits of tank 2. The first short-circuit could have contained as much as 160 joules of energy, which is within the current-protection level of the fan circuits. Tests have shown that two orders of magnitude less energy than this is sufficient to ignite the polytetrafluoroethylene insulation on the fan circuits in the tank. Consequently, the evidence indicates that the insulation on the fan wiring was ignited by the energy in the short-circuit.

Source record↗

Hydrophobic liquid/gas separator for heat pipes

Perforated nonwetting plug of material such as polytetrafluoroethylene is mounted in gas reservoir feed tube, preferably at end which extends into heat pipe condenser section, to prevent liquid from entering gas reservoir of passively controlled heat pipe.

Marcus, B. D.↗

Fundamental ignition study for material fire safety improvement, part 1

The investigation of preignition, ignition, and combustion characteristics of Delrin (acetate terminated polyformaldehyde) and Teflon (polytetrafluoroethylene) resins in air and oxygen are presented. The determination of ignition limits and their dependence on temperature and the oxidizing media, as well as the analyses of the volatiles produced, were studied. Tests were conducted in argon, an inert medium in which only purely pyrolytic reactions can take place, using the stagnation burner arrangement designed and constructed for this purpose. A theoretical treatment of the ignition and combination phenomena was devised. In the case of Delrin the ignition and ignition delays are apparently independent of the gas (air, oxygen) temperatures. The results indicate that hydrogen is the ignition triggering agent. Teflon ignition limits were established in oxygen only.

Paciorek, K. L.↗

Performance of high speed ball bearings with lead plated retainers in liquid hydrogen for potential use in a radiation environment

Ball bearings (40-mm bore) with lead coated, aluminum-bronze retainers were operated successfully in liquid hydrogen at 30,000 rpm under a thrust load of 1780 newtons (400 lb) for running times up to 15 hours. The lead transfer films on the bearing surfaces prevented galling of bearing components. The lead coated retainers used in this investigation show promise for use in the high radiation environments, where polytetrafluoroethylene (PTFE) based materials are not suitable. Failure was a result of the loss of lead lubricant on the retainer-inner-land and ball-pocket surfaces. The longest bearing life (15 hr) was achieved with a lead coating thickness of 50 micrometers (0.002 in.) on the retainer. Other bearings had lives of 2 to 6 hours.

Wisander, D. W.↗

Adhesion and transfer of PTFE to metals studied by auger emission spectroscopy

The adhesion and transfer of polytetrafluoroethylene (PTFE) to metals in ultrahigh vacuum has been studied using Auger emission spectroscopy. The transfer was effected both by compressive static contact and by sliding contact. The transfer observed after static contact was independent of the chemical constitution of the substrate. Electron induced desorption of the fluorine in the transferred PTFE showed that the fluorine had no chemical interaction with the metal substrate. The coefficient of friction on metals was independent of the chemical constitution of the substrate. However, sliding PTFE on soft metals such as aluminum, generated wear fragments that lodged in the PTFE and machined the substrate.

Pepper, S. V.↗

Adhesion and transfer of polytetrafluorethylene to metals studied by Auger emission spectroscopy

The adhesion and transfer of polytetrafluoroethylene (PTFE) to metals in ultrahigh vacuum were studied. The transfer was effected both by compressive static contact and by sliding contact. The transfer observed after static contact was independent of the chemical constitution of the substrate. Electron-induced desorption of the fluorine in the transferred PTFE showed that the fluorine had no chemical interaction with the metal substrate. The coefficient of friction on metals was independent of the chemical constitution of the substrate. However, sliding PTFE on soft metals, such as aluminum, generated wear fragments that lodged in the PTFE and machined the substrate.

Pepper, S. V.↗

Thermal anomalies in stressed Teflon.

In the course of testing polytetrafluoroethylene (Teflon) as a calorimetric gasketing material, serendipity revealed a thermal anomaly in stressed film that occurs concomitantly with the well-documented 25 C transition. The magnitude of the excess energy absorption - about 35 cal/g - is suggested to be related to the restricted thermal expansion of the film.

Lee, S. H.↗

Auger analysis of films formed on metals in sliding contact with halogenated polymers

The use of Auger electron spectroscopy (AES) to search for transferred polymer must contend with the fact that there has been no published work on Auger analysis of polymers. Since this is a new area for AES, the Auger spectra of polymers and of halogenated polymers in particular is discussed. It is shown that the Auger spectra of halogenated polymers have certain characteristics that permit an assessment of whether a polymeric transfer film has been established by sliding contact. The discussion is general and the concepts should be useful in considering the Auger analysis of any polymer. The polymers chosen for this study are the halogenated polymers polytetrafluoroethylene (PTFE), polyvinyl chloride (PVC), and polychlorotrifluorethylene (PCTFE).

Pepper, S. V.↗

The Acute Inhalation Toxicity in Rats from the Pyrolysis Products of Four Fluoropolymers

Male Sprague-Dawley rats (225?250 g) were exposed to the thermal degradation products from four fluoropolymers. The three polymers containing vinylidene fluoride and hexafluoropropene (VF2/HFP) were pyrolyzed at 550? and 800?C, whereas polytetrafluoroethylene (PTFE) was pyrolyzed at 625 and 800?C. At the lower temperatures, the pyrolysate from the copolymer of vinylidene fluoride and hexafluoropropene (VF2/HFP) was less toxic than the pyrolysates from either the terpolymer of vinyidene fluoride, hexafluoropropene, and tetrafluoroethylene (VF2/HFP/TFE) or the copolymer of vinylidene fluoride and hexafluoropropene with ?additives? (VF2/HFP-A). However, the pyrolysates from the VF2/HFP-containing materials produced less toxic products than the pyrolysate from PTFE at 625?C. When the pyrolysis temperature was increased to 800?C, very little difference was noted between the pyrolysis toxicity for any of the VF2/HFP-containing polymers with the most toxic pyrolysate again produced by PTFE. Carbon monoxide levels were all sublethal. No correlation could be established between hydrolyzable fluoride levels and the lethality of the pyrolysates. Death following exposure occurred within 48 hr due to acute pulmonary edema and hemorrhage. Survival of this acute phase was followed by alveolar lymphocytic infiltration and peribronchial tissue proliferation.

Carter, V. L., Jr.↗