Solid state switch panel

An intensive study of various forms of transducers was conducted with application towards hermetically sealing the transducer pick off and all electronics. The results indicated that the Hall effect devices and a LED/phototransistor combination were the most practical for this type of application. Therefore, hardware was developed utilizing a magnet/Hall effect transducer for single action switches and LED/phototransistor transducers for rotary multiposition or potentiometer applications. A number of switches were built and models were hermetically sealed to prove the feasibility of this type of fabrication. One of each type of switch was subjected to temperature cycling, vibration, and EMI tests.

Beenfeldt, E.↗

Orthotic arm joint

An improved orthopedic (orthotic) arm joint that can be used in various joint of mechanical arms is described. The arm joints includes a worm, which is coupled to an electric motor for rotating a worm gear carried within a rotatable housing. The worm gear is supported on a thrust bearing and the rotatable housing is supported on a radial thrust bearing. A bolt extends through the housing, bearings, and worm gear for securing the device together. A potentiometer extends through the bolt, and is coupled to the rotatable housing for rotating therewith, so as to produce an electrical signal indicating the angular position of the rotatable housing.

Dane, D. H.↗

Balloon-borne ultraviolet stellar spectrometer: Acquisition, tracking and command systems

The NASA Balloon-borne Ultraviolet Stellar Spectrometer (BUSS) which is carried to an altitude of 40 km by a 15 million cubic foot balloon for night-time observations of ultraviolet stellar spectra is discussed. The BUSS optical system, comprising an 0.40 m aperture Cassegrain telescope and an Ebert-Fastie spectrometer, points at various selected stars and focuses a portion of their spectra on the photocathode of an image dissector tube. The spectral region between 2,775 Angstroms and 2,825 Angstroms is sampled by the detector at 0.25 Angstroms increments using photon counting techniques. The pointing system for the payload uses a pair of orthogonal magnetometers which sense the earth's magnetic field for an aximuth reference, and a platform potentiometer for an elevation reference. This pointing system places the target star within the 3x1 degree field of view of an outer optical star tracker. The outer star tracker is then used to point the entire instrument to within one arc minute of the target star.

Gibson, W. C.↗

Controlled freezing of biological samples

Apparatus consists of thermocouple connected to semiconductor reference junction. Junction is connected to amplifier that boosts signal by 1,000. High-level signal is displayed on recorder and fed into second amplifier where it is compared with signal from potentiometer of programmed dc reference in bag-temperature programer. Difference in signals indicates output voltage. Remaining circuitry provides zero-phase, time-proportion control of heaters such that heater power is directly proportional to error signal.

Cygnarowicz, T. A.↗

Analog actuator-piston memory

Simple analog control system of digitally controlled acuator uses 'stopped' position of actuator as 'memory' and potentiometer as sensing element during power failure to reload drive circuit to value equal to its last position preceding power loss.

Sable, B. A.↗

Method and device for the detection of phenol and related compounds

A method is described which permits the selective oxidation and potentiometric detection of phenol and related compounds in an electrochemical cell. An anode coated with a gel immobilized oxidative enzyme and a cathode are each placed in an electrolyte solution. The potential of the cell is measured by a potentiometer connected to the electrodes.

Schiller, J. G.↗

IUSThrust Vector Control (TVC) servo system

The IUS TVC SERVO SYSTEM which consists of four electrically redundant electromechanical actuators, four potentiometer assemblies, and two controllers to provide movable nozzle control on both IUS solid rocket motors is developed. An overview of the more severe IUS TVC servo system design requirements, the system and component designs, and test data acquired on a preliminary development unit is presented. Attention is focused on the unique methods of sensing movable nozzle position and providing for redundant position locks.

Conner, G. E.↗

Simple torsion test for shear moduli determination of orthotropic composites

The shear moduli G13 and G23 for two different composites (AS/3501 and T300/5209) of uniaxial and cross-ply fiber orientations were determined by torsion testing of flat specimens of rectangular cross section. Torsion tests were run under controlled angle of twist in an electro-hydraulic servo-controlled test system. Both laser and potentiometer methods of measuring the angle of twist were used. The in-plane shear modulus was calculated with a formula for transversally isotropic materials and a formula for orthotropic materials, while the out-of-plane shear modulus was calculated from the orthotropic material formula. Neither the uniaxial nor the angle-ply composite materials studied were transversely isotropic. The degree of anisotropy for the angle-ply materials was several times greater than that of the uniaxial composites. For specimens of uniaxial fiber orientation, the in-plane shear moduli could be calculated to a good approximation by using the isotropic formula and test machine deflection data.

Sumsion, H. T.↗

Focal plane transport assembly controls for the High Energy Astronomy Observatory X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B) is a satellite observatory for the purpose of performing a detailed X-ray survey of the celestial sphere. Measurements will be made of stellar radiation in the range of 0.2 to 20 keV. The central part of the Observatory is an X-ray telescope, into the focus of which a variety of imaging instruments and spectrographs may be introduced. The telescope has a resolution of about 1 arc second, so that the instruments must be placed with extreme precision. This is obtained by a mechanical system of toggles and stops and a motor drive system controlled by a position sensing potentiometer with a resolution of about 1.5 degrees

Carpenter, C.↗

Skin friction measuring device for aircraft

A skin friction measuring device for measuring the resistance of an aerodynamic surface to an airstream is described. It was adapted to be mounted on an aircraft and is characterized by a friction plate adapted to be disposed in a flush relationship with the external surface of the aircraft and be displaced in response to skin friction drag. As an airstream is caused to flow over the surface, a potentiometer connected to the plate for providing an electrical output indicates the magnitude of the drag.

Montoya, L. C.↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials, part 1

The use of pressure differentials in a flight control system was evaluated. The pressure profile around the test surface was determined using two techniques: (1) windtunnel data (actual); and (2) NASA/Langley Single Element Airfoil Computer Program (theoretical). The system designed to evaluate the concept of using pressure differentials is composed of a sensor drive and power amplifiers, actuator, position potentiometer, and a control surface. The characteristics (both desired and actual) of the system and each individual component were analyzed. The desired characteristics of the system as a whole are given. The flight control system developed, the testing procedures and data reduction methods used, and theoretical frequency response analysis are described.

Hrabak, R. R.↗

Simple Temperature Regulator for a Cold Chamber

Electronic control circuit holds cold chamber at selectable temperature and lights warning light if temperature exceeds predetermined level amplifiers. Temperature regulator circuit and warning-light circuit are independent of one another, but reference-level potentiometers are ganged. Temperature control circuit includes some feedback to prevent refrigeration unit from cycling on and off too frequently.

Redmond, W. G.↗

Electronic Load Tests High-Voltage Solar Arrays

Adjustable electronic load in solar-cell-array test instrument uses ten power MOSFET's and eight resistors. Two gate-control voltages adjusting load are derived from single, manually-operated, ganged potentiometer control. Third adjustable resistor adjusts relative turn-on points of two groups of transistors.

Miller, E. L.↗

Motor power factor controller with a reduced voltage starter

A power factor type motor controller is disclosed in which the conventional power factor constant voltage command signal is replaced during a starting interval with a graduated control voltage. This continuation-impart of a pending patent application (Serial No. 199, 765: Three Phase Factor Controller) provides a means for modifying the operation of the system for a motor start-up interval of 5 to 30 second. Using a ramp generators, an initial ramp-like signal replaces a constant power factor signal supplied by a potentiometer. The ramp-like signal is applied to a 15 terminal where it is summed with an operating power factor signal from phase detectors in order to obtain a control signal for ultimately controlling SCR devices. The SCR devices are turned on at an advancing rate with time responsive to the combination signal described rather than simply a function of a ramp-like signal alone.

Nola, F. J.↗

Longwall Guidance and Control Development

The longwall guidance and control (G&C) system was evaluated to determine which systems and subsystems lent themselves to automatic control in the mining of coal. The upper coal/shale interface was identified as the reference for a vertical G&C system, with two sensors (the natural backgound and the sensitized pick) being used to locate and track this boundary. In order to insure a relatively smooth recession surface (roof and floor of the excavated seam), a last and present cut measuring instrument (acoustic sensor) was used. Potentiometers were used to measure elevations of the shearer arms. The intergration of these components comprised the vertical control system (pitch control). Yaw and roll control were incorporated into a face alignment system which was designed to keep the coal face normal to its external boundaries. Numerous tests, in the laboratory and in the field, have confirmed the feasibility of automatic horizon control, as well as determining the face alignment.

Source record↗

Two-Wire to Four-Wire Audio Converter

Simple circuit provides interface between normally incompatible voicecommunication lines. Circuit maintains 40 dB of isolation between input and output halves of four-wire line permitting two-wire line to be connected. Balancing potentiometer, Rg, adjusts gain of IC2 to null feed through from input to output. Adjustment is done on workbench just after assembly.

Talley, G. L., Jr↗

Constant-Operating-Resistance Hot-Wire Probe

Effects of lead-wire-resistance changes with temperature nullified. Constant-operating-resistance hot-wire probe uses two sets of leads. Exposed to identical conditions, comparison of resistance gives change in sensing element itself. Data taken in more convenient manner, with advantage of not having to constantly check for possible changes in lead resistance and consequently readjust potentiometer.

Stainback, P. C.↗