Search NASA⌕ Search

SEARCH · Search NASA

Results for “power maximization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Energy exchanges of swimming man

Three male swimmers underwent 10-min resting and 20-min swimming (breaststroke) exposures in a swimming flume. Water temperatures in separate exposures were 18, 26, and 33 C. At each water temperature the subjects rested and swam at water velocities of 0.50, 0.75, and 0.95 m/sec, which were designed to produce around 40, 70, and 100% of maximal aerobic power. Measurements were made of esophageal temperature, four skin temperatures, water temperature, heat flow from five local skin surfaces (Hatfield-Turner disks), and oxygen uptake. Calculations were made of mean area-weighted skin temperature and heat flow, metabolic rate, and heat storage. Internal body temperature changes after 20 min of swimming were related to water temperature, swimming intensity, and body composition.

Nadel, E. R.↗

Forearm blood flow during body temperature transients produced by leg exercise

Subjects exercised for 30 min on a bicycle ergometer at 30, 50, and 70% of maximal aerobic power in ambient temperatures of 15, 25, and 35 C and vapor pressures of less than 18 torr. Exercise was used to vary internal temperature during an experiment, and different ambient temperatures were used to vary skin temperatures independently of internal temperature. Forearm skin temperature was fixed at about 36.5 C. Esophageal temperature was measured with a thermocouple at the level of the left atrium, and mean skin temperature was calculated from a weighted mean of thermocouple temperatures at eight skin sites. Forearm blood flow was measured by electrocapacitance plethysmography. Data are well accounted for by a linear equation independent of exercise intensity, although some subjects showed an equivocal vasodilator effect of exercise.

Wenger, C. B.↗

Nocturnal lowering of thresholds for sweating and vasodilation

The effect of the time of day on the relation of the heat-dissipating responses (sweating and vasodilation) to esophageal and mean skin temperatures was investigated. These parameters were measured in six subjects exercised at 60-70% of maximal aerobic power in a 25 deg C ambient. Results indicate that a circadian rhythm in the thresholds for sweating and vasodilation can account for much of the rhythm of internal body temperature. The circadian rhythm in the operation of the thermoregulatory system seems to be expressed through a reference point shared by vasomotor and sudomotor controls.

Wenger, C. B.↗

Bandwidth limitations on noiseless optical channel capacity

The channel capacity of an optical communications link utilizing direct photon detection can be substantially larger than the heterodyne detection quantum limit. In the limit of a noiseless channel the capacity per received photon can even be infinite. In most communications systems the real constraint is to deliver a certain throughput capacity measured in nats/second. The current investigation has the objective to show that due to physical limitations on the minimum time resolution which can be achieved, and for any given throughput capacity in nats/second, there exists an optimum PPM word size which maximizes the 'power efficiency capacity' expressed in nats/photon. Such an optimization will allow the system-designer to minimize the amount of power needed to achieve the desired throughput without violating his bandwidth constraint.

Butman, S. A.↗

Bridge feedback for active damping augmentation

A method is described for broadband damping augmentation of a structural system in which the active members (with feedback control) were developed such that their mechanical input impedance can be electrically adjusted to maximize the energy dissipation rate in the structural system. The active member consists of sensors, an actuator, and a control scheme. A mechanical/electrical analogy is described to model the passive structures and the active members in terms of their impedance representation. As a result, the problem of maximizing dissipative power is analogous to the problem of impedance matching in the electrical network. Closed-loop performance was demonstrated for single- and multiple-active-member controlled truss structure.

Chen, G.-S.↗

Polarization filtering of SAR data

A theoretical analysis of polarization filtering for the bistatic case is developed for optimum discrimination between two types of targets. The resulting method is half analytical and half numerical. Because it is based on the Stokes matrix representation, the targets of interest can be extended targets. The scattered field from such targets is partially polarized. This method is then applied to the monostatic case with numerical examples relying on the JPL (Jet Propulsion Laboratory) full-polarimetric L-band radar data. A matched filter to maximize the power ratio between urban and natural targets is developed. The results show that the same filter is optimal for both ocean and forest targets as natural targets.

Dubois, Pascale C.↗

Does training-induced orthostatic hypotension result from reduced carotid baroreflex responsiveness?

As manned space travel has steadily increased in duration and sophistication, the answer to a simple, relevant question remains elusive. Does endurance exercise training - high intensity rhythmic activity, performed regularly for extended periods of time - alter the disposition to, or severity of, postflight orthostatic hypotension? Research results continue to provide different views; however, data are difficult to compare because of the following factors that vary between investigations: the type of orthostatic stress imposed (+Gz, lower body negative pressure (LBNP), head-up tilt); pretest perturbations used (exercise, heat exposure, head-down tilting, bed rest, water immersion, hypohydration, pharmacologically-induced diuresis); the length of the training program used in longitudinal investigations (days versus weeks versus months); the criteria used to define fitness; and the criteria used to define orthostatic tolerance. Generally, research results indicate that individuals engaged in aerobic exercise activities for a period of years have been reported to have reduced orthostatic tolerance compared to untrained control subjects, while the results of shorter term longitudinal studies remain equivocal. Such conclusions suggest that chronic athletic training programs reduce orthostatic tolerance, whereas relatively brief (days to weeks) training programs do not affect orthostatic tolerance to any significant degree (increase or decrease). A primary objective was established to identify the alterations in blood pressure control that contribute to training-induced orthostatic hypotension (TIOH). Although any aspect of blood pressure regulation is suspect, current research has been focused on the baroreceptor system. Reductions in carotid baroreflex responsiveness have been documented in exercise-trained rabbits, reportedly due to an inhibitory influence from cardiac afferent, presumably vagal, nerve fibers that is abolished with intrapericardiac denervation. The purpose of this investigation was to attempt to determine if similar relationships existed in men with varied levels of fitness, using maximal aerobic power, VO2 max, as the marker of fitness.

Pawelczyk, James A.↗

TRMM Solar Array

Basic requirement of 978.59 watts per Panel output @ 58.9 volts B.O.L. was met on an average basis per agreement with NASA. Lower grade Cells were used on the shadowed Panel (Boom shadow) to maximize available power to the Spacecraft. The average output @ 58.9 volts was 991 watts. The outputs of the four t4) Panels ranged from 960 to 1,022 watts. The Panels successfully passed environmental testing at TRW to the contract specification and subsequent testing at NASA which involved output measurements at elevated temperatures. As this type of Array had never previously been built by TRW (aluminum Substrate with 4 cm x 4.4 cm GaAs Cells), the TRMM Program was a development effort combined with a Qual and Flight production effort. The most significant technical problem was Cell cracking during Qual thermal cycling. The cracking problem was determined to be generic within our Solar Array factory in the application of GaAs Cells to our designs. As a result, a TRW funded manufacturing process verification panel (known as the Manufacturing Verification Panel) was built to demonstrate our ability to properly apply GaAs Cells. The original Qual Panel comprised three (3) design variations with respect to Coverglass-to-Cell and Cell-to-Substrate adhesives. The intent was to qualify multiple designs in case one or more failed. When two of the three combinations failed due to excessive Cell breakage during thermal cycling, NASA was reluctant to allow Flight production based on the one remaining good Qual Panel Quadrant. This issue was pivotal for continuing the contract. Facts and recommendations are as follows: (1) The cause of the excessive cracking was never determined. and (2) The areas where the excessive cracking occurred utilized DC93-500 glassing adhesive which was NASA approved, and had been widely used by TRW on a multitude of projects.

Source record↗

Diminished forearm vasomotor response to central hypervolemic loading in aerobically fit individuals

The aim of this study was to test the hypothesis that cardiopulmonary baroreflex control of forearm vascular resistance (FVR) during central hypervolemic loading was less sensitive in exercise trained high fit individuals (HF) compared to untrained average fit individuals (AF). Eight AF (age: 24 +/- 1 yr and weight: 78.9 +/- 1.7 kg) and eight HF (22 +/- 1 yr 79.5 +/- 2.4 kg) voluntarily participated in the investigation. Maximal aerobic power (determined on a treadmill), plasma volume and blood volume (Evans blue dilution method) were significantly greater in the HF than AF (60.8 +/- 0.7 vs. 41.2 +/- 1.9 ml.kg-1.min-1, 3.96 +/- 0.17 vs 3.36 +/- 0.08 1, and 6.33 +/- 0.23 vs 5.28 +/- 0.13 1). Baseline heart rate (HR), central venous pressure (CVP), mean arterial pressure (MAP, measured by an intraradial catheter or a Finapres finger cuff), forearm blood flow (FBF, plethysmography), and FVR, calculated from the ratio (MAP-CVP)/FBF, were not different between the HF and the AF. Lower body negative pressure (LBNP, -5, -10, -15, and -20 torr) and passive leg elevation (LE, 50 cm) combined with lower body positive pressure (LBPP, +5, +10, and +20 torr) were utilized to elicit central hypovolemia and hypervolemia, respectively. Range of CVP (from LBNP to LE+LBPP) was similar in the AF (from -3.9 to +1.9 mm Hg) and HF (from -4.0 to +2.2 mm Hg). However, FVR/CVP was significantly less in the HF (-1.8 +/- 0.1 unit.mm Hg-1) than AF (-34 +/- 0.1 unit.mm Hg-1). The FVR decrease in response to increase in CVP was significantly diminished in the HF (-1.46 +/- 0.45 unit.mm Hg-1) compared to the AF (-4.40 +/- 0.97 unit.mm Hg-1), and during LBNP induced unloading the FVR/CVP of the HF (-2.01 +/- 0.49 unit.mm Hg-1) was less (P < 0.08) than the AF (-3.28 +/- 0.69 unit.mm Hg-1). We concluded that the cardiopulmonary baroreceptor mediated FVR reflex response was significantly less sensitive to changes in CVP in individuals who practice exercise training.

NASA Discipline Number 93-10↗

Cluster Computing for Embedded/Real-Time Systems

Embedded and real-time systems, like other computing systems, seek to maximize computing power for a given price, and thus can significantly benefit from the advancing capabilities of cluster computing.

cluster computing technology embedded clusters sta↗

Multi-mode horn

A horn has an input aperture and an output aperture, and comprises a conductive inner surface formed by rotating a curve about a central axis. The curve comprises a first arc having an input aperture end and a transition end, and a second arc having a transition end and an output aperture end. When rotated about the central axis, the first arc input aperture end forms an input aperture, and the second arc output aperture end forms an output aperture. The curve is then optimized to provide a mode conversion which maximizes the power transfer of input energy to the Gaussian mode at the output aperture.

Neilson, Jeffrey M.↗

An Update on Mortality in the U.S. Astronaut Corps: 1959-2009

Although it has now been over 50 years since mankind first ventured into space, the long-term health impacts of human space flight remain largely unknown. Identifying factors that affect survival and prognosis among those who participate in space flight is vitally important, as the era of commercial space flight approaches and NASA prepares for missions to Mars. The Longitudinal Study of Astronaut Health is a prospective study designed to examine trends in astronaut morbidity and mortality. The purpose of this analysis was to describe and explore predictors of overall and cause-specific mortality among individuals selected for the U.S. astronaut corps. All U.S. astronauts (n=321), regardless of flight status, were included in this analysis. Death certificate searches were conducted to ascertain vital status and cause of death through April 2009. Data were collected from medical records and lifestyle questionnaires. Multivariable Cox regression modeling was used to calculate the mortality hazard associated with embarking on space flight, adjusted for sex, race, and age at selection. Between 1959 and 2009, there were 39 (12.1%) deaths. Of these deaths, 18 (42.2%) were due to occupational accidents; 7 (17.9%) were due to other accidents; 6 (15.4%) were attributable to cancer; 6 (15.4%) resulted from cardiovascular/circulatory diseases; and 2 (5.1%) were from other causes. Participation in space flight did not significantly increase mortality hazard over time (adjusted hazard ratio=0.57; 95% confidence interval=0.26-1.26. Because our results are based on a small sample size, future research that includes payload specialists, other space flight participants, and international crew members is warranted to maximize statistical power.

Amirian, E.↗

Effects of Short- and Long-Duration Space Flight on Neuromuscular Function

The Functional Task Tests (FTT) is an interdisciplinary study designed to correlate the changes in functional tasks (such as emergency egress, ladder climbing, and hatch opening) with changes in neuromuscular, cardiovascular, and sensorimotor function. One aspect of the FTT, the neuromuscular function test, is used to investigate the neuromuscular component underlying changes in the ability of astronauts to perform functional tasks (representative of critical mission tasks) safely and quickly after flight. PURPOSE: To describe neuromuscular function after short- and long-duration space flight. METHODS: To date, 5 crewmembers on short-duration (10- to 15-day) missions and 3 on long-duration missions have participated. Crewmembers were assessed 30 days before flight, on landing day (short-duration subjects only) and 1, 6, and 30 days after landing. The interpolated twitch technique, which utilizes a combination of maximal voluntary contractions and electrically evoked contractions, was used to assess the maximal voluntary isometric force (MIF) and central activation capacity of the knee extensors. Leg-press and bench-press devices were used to assess MIF and maximal dynamic power of the lower and upper body respectively. Specifically, power was measured during concentric-only ballistic throws of the leg-press sled and bench-press bar loaded to 40% and 30% of MIF respectively. RESULTS: Data are currently being collected from both Shuttle and ISS crewmembers. Emerging data indicate that measures of knee extensor muscle function are decreased with long-duration flight. DISCUSSION: The relationships between flight duration, neural drive, and muscle performance are of particular interest. Ongoing research will add to the current sample size and will focus on defining changes in muscle performance measures after long-duration space flight.

Buxton, Roxanne E.↗

80-GHz MMIC HEMT Voltage-Controlled Oscillator

A voltage-controlled oscillator (VCO) that operates in the frequency range from 77.5 to 83.5 GHz has been constructed in the form of a monolithic microwave integrated circuit (MMIC) that includes high-electron-mobility transistors (HEMTs). This circuit is a prototype of electronically tunable signal sources in the 75-to-110-GHz range, needed for communication, imaging, and automotive radar applications, among others. This oscillator (see Figure 1) includes two AlInAs/GaInAs/InP HEMTs. One HEMT serves mainly as an oscillator gain element. The other HEMT serves mainly as a varactor for controlling the frequency: the frequency-control element is its gate-to-source capacitance, which is varied by changing its gate supply voltage. The gain HEMT is biased for class-A operation (meaning that current is conducted throughout the oscillation cycle). Grounded coplanar waveguides are used as impedance-matching transmission lines, the input and output matching being chosen to sustain oscillation and maximize output power. Air bridges are placed at discontinuities to suppress undesired slot electromagnetic modes. A high density of vias is necessary for suppressing a parallel-plate electromagnetic mode that is undesired because it can propagate energy into the MMIC substrate. Previous attempts at constructing HEMT-based oscillators yielded circuits with relatively low levels of output power and narrow tuning ranges. For example, one HEMT VCO reported in the literature had an output power of 7 dBm (.5 mW) and a tuning range 2-GHz wide centered approximately at a nominal frequency of 77 GHz. In contrast, as shown in Figure 2, the present MMIC HEMT VCO puts out a power of 12.5 dBm (.18 mW) or more over the 6-GHz-wide frequency range from 77.5 to 83.5 GHz

Samoska, Lorene↗

The First Intervention Study in Elder Self-Neglect: A Randomized Clinical Trial to Improve Vitamin D Levels

Despite high mortality rates, elder self-neglect is characterized by refusal of medical and social interventions. To date there have been no tested clinical interventions in elders who self-neglect. Previous research from the TEAM Institute has shown significantly low vitamin D levels in this population. This study aimed to determine the feasibility of a clinical intervention. Replacement of vitamin D was chosen because of its ease of administration and favorable safety profile. Methods: A randomized clinical trial using directly observed therapy of vitamin D was conducted using 50 elders, >65 years of age, with Adult Protective Services (APS) validated self-neglect. A staggered intervention with waiting controls was used to maximize statistical power. One-third (n=17) of the group was administered 50,000 IU vitamin D2 (ergocalciferol) monthly and the remainder (n=33) were administered 400 IU monthly. Serum 25-OH vitamin D was assessed at baseline and 5-months. Results: 69% agreed to participate in the study and of those n=40 (80%) remained at 5-months. At baseline, 12% (n=7) were deficient in vitamin D (<30nmol/L) and approximately 38% (n=22) had inadequate vitamin D levels (<50nmol/L). The baseline 25-OH vitamin D level was 59 nmol/L +25 (mean SD), and increased significantly to 72nmol/L +21 nmol/L at 5-months. Conclusion: These data are the first to provide evidence that clinical interventions are feasible in elders who self-neglect. The increase in vitamin D levels confirmed that the study personnel were able to successfully intervene community-dwelling elders with self-neglect. This study sets the precedent for future intervention and prevention studies

Burnett, Jason↗

Azimuthal Spoke Propagation in Hall Effect Thrusters

Spokes are azimuthally propagating perturbations in the plasma discharge of Hall Effect Thrusters (HETs) that travel in the E x B direction and have been observed in many different systems. The propagation of azimuthal spokes are investigated in a 6 kW HET known as the H6 using ultra-fast imaging and azimuthally spaced probes. A spoke surface is a 2-D plot of azimuthal light intensity evolution over time calculated from 87,500 frames/s videos. The spoke velocity has been determined using three methods with similar results: manual fitting of diagonal lines on the spoke surface, linear cross-correlation between azimuthal locations and an approximated dispersion relation. The spoke velocity for three discharge voltages (300, 400 and 450 V) and three anode mass flow rates (14.7, 19.5 and 25.2 mg/s) yielded spoke velocities between 1500 and 2200 m/s across a range of normalized magnetic field settings. The spoke velocity was inversely dependent on magnetic field strength for low B-field settings and asymptoted at B-field higher values. The velocities and frequencies are compared to standard drifts and plasma waves such as E x B drift, electrostatic ion cyclotron, magnetosonic and various drift waves. The empirically approximated dispersion relation yielded a characteristic velocity that matched the ion acoustic speed for 5 eV electrons that exist in the near-anode and near-field plume regions of the discharge channel based on internal measurements. Thruster performance has been linked to operating mode where thrust-to-power is maximized when azimuthal spokes are present so investigating the underlying mechanism of spokes will benefit thruster operation.

Cylindrical Hall Thruster (CHT)↗

Azimuthal spoke propagation in Hall Effect Thrusters

Spokes are azimuthally propagating perturbations in the plasma discharge of Hall Effect Thrusters (HETs) that travel in the E × B direction and have been observed in many different systems. The propagation of azimuthal spokes are investigated in a 6 kW HET known as the H6 using ultra-fast imaging and azimuthally spaced probes. A spoke surface is a 2-D plot of azimuthal light intensity evolution over time calculated from 87,500 frames/s videos. The spoke velocity has been determined using three methods with similar results: manual fitting of diagonal lines on the spoke surface, linear cross-correlation between azimuthal locations and an approximated dispersion relation. The spoke velocity for three discharge voltages (300, 400 and 450 V) and three anode mass flow rates (14.7, 19.5 and 25.2 mg/s) yielded spoke velocities between 1500 and 2200 m/s across a range of normalized magnetic field settings. The spoke velocity was inversely dependent on magnetic field strength for low B-field settings and asymptoted at B-field higher values. The velocities and frequencies are compared to standard drifts and plasma waves such as E × B drift, electrostatic ion cyclotron, magnetosonic and various drift waves. The empirically approximated dispersion relation yielded a characteristic velocity that matched the ion acoustic speed for 5 eV electrons that exist in the near-anode and near-field plume regions of the discharge channel based on internal measurements. Thruster performance has been linked to operating mode where thrust-to-power is maximized when azimuthal spokes are present so investigating the underlying mechanism of spokes will benefit thruster operation.

Polk, James E.↗

120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna

Two monolithic microwave integrated circuits (MMICs) have been designed and built to function together as a source of electromagnetic radiation at a frequency of 120 GHz. One of the MMICs is an oscillator and is the highest-power 120-GHz oscillator reported thus far in the literature. The other MMIC is an end-fire antenna that radiates the oscillator signal. Although these MMICs were constructed as separate units and electrically connected with wire bonds, future oscillator/ antenna combinations could readily be fabricated as monolithic integrated units. Such units could be used as relatively high-power solid-state microwave sources in diverse applications that include automotive radar, imaging, scientific instrumentation, communications, and radio astronomy. As such, these units would be attractive alternatives to vacuum-tube oscillators, which are still used to obtain acceptably high power in the frequency range of interest. The oscillator (see figure) includes a high-electron-mobility transistor (HEMT), with gate-periphery dimensions of 4 by 37 m, in a common-source configuration. The series feedback element of the oscillator is a grounded coplanar waveguide (CPW) at the source. The HEMT is biased for class-A operation (meaning that current is conducted throughout the oscillation cycle) to maximize the output power of the oscillator. Input and output impedance-matching circuit elements are designed to maximize output power and to establish the conditions needed for oscillation. The design of the antenna takes advantage of surface waves, which, heretofore, have been regarded as highly disadvantageous because they can leak power and degrade the performances of antennas that have not been designed to exploit them. Measures taken to suppress surface waves have included complex machining of circuit substrates and addition of separate substrates. These measures are difficult to implement in standard MMIC fabrication processes. In contrast, because the design of the present antenna eliminates the need to suppress surface waves, the fabrication of the antenna is fully compatible with standard MMIC fabrication processes.

Samoska, Lorene↗