Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system parameter estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Conformal duality of the nonlinear Schrödinger equation: Theory and applications to parameter estimation

The nonlinear Schrödinger equation (NLSE) in one spatial dimension has stationary solutions similar to those of the linear Schrödinger equation (LSE) as well as more exotic solutions such as solitary waves and quantum droplets. Here, we present a newly discovered conformal duality which unifies the stationary and time-dependent traveling-wave solutions of the one-dimensional cubic-quintic NLSE, the cubic NLSE and LSE. Any two systems that are classified by the same single number called the cross ratio are related by this symmetry. Notably, the conformal duality can also be adapted in Newtonian mechanics and serves as a powerful tool for investigating physical systems that otherwise cannot be directly accessed in experiments. Further, we show that the conformal symmetry is a valuable resource to substantially improve NLSE parameter estimation from noisy empirical data by introducing an optimization afterburner. The new method therefore has far reaching practical applications for nonlinear physical systems. Published by the American Physical Society 2025

Reinhardt, David B. (ORCID:0009000409812838)↗

Sensor Error Estimation for Reactor Coolant System with Generalization Error Equations

We consider a simplified version of the sensor error estimation problem in pressure sensors in the primary coolant system of a nuclear power plant under the condition that a majority of sensors are error-free. We present a sensor fusion method to estimate sensor errors in the primary coolant system of a power reactor by using measurements collected by multiple sensors. The underlying relationship between the measured and estimated parameters is inferred using measurements collected under controlled no-error conditions of the plant. We propose a machine learning approach to train fusers that provide an estimate of the sensor measurement by using measurements from other sensors, and the difference between the actual sensor measurement and its estimate provides the sensor estimate. We present generalization error equations for these methods that characterize the performance of their sensor error estimates on future measurements using the distribution-free machine learning formulation.

Rao, Nageswara S.↗

Optimal Model-Based Fault Estimation and Correction for Particle Accelerators and Industrial Plants Using Combined Support Vector Machines and First Principles Models

Timely estimation of deviations from optimal performance in complex systems and the ability to identify corrective measures in response to the estimated parameter deviations has been the subject of extensive research over the past four decades. The implications in terms of lost revenue from costly industrial processes, operation of large-scale public works projects and the volume of the published literature on this topic clearly indicates the significance of the problem. Applications range from manufacturing industries (integrated circuits, automotive, etc.), to large-scale chemical plants, pharmaceutical production, power distribution grids, and avionics. In this project we investigated a new framework for building parsimonious models that are suited for diagnosis and fault estimation of complex technical systems. We used Support Vector Machines (SVMs) to model potentially time-varying parameters of a First-Principles (FP) description of the process. The combined SVM & FP model was built (i.e. model parameters were trained) using constrained optimization techniques. We used the trained models to estimate faults affecting simulated beam lifetime. In the case where a large number of process inputs are required for model-based fault estimation, the proposed framework performs an optimal nonlinear principal component analysis of the large-scale input space, and creates a lower dimension feature space in which fault estimation results can be effectively presented to the operation personnel. To fulfill the main technical objectives of the Phase I research, our Phase I efforts have focused on: (1) SVM Training in a Combined Model Structure - We developed the software for the constrained training of the SVMs in a combined model structure, and successfully modeled the parameters of a first-principles model for beam lifetime with support vectors. (2) Higher-order Fidelity of the Combined Model - We used constrained training to ensure that the output of the SVM (i.e. the parameters of the beam lifetime model) are physically meaningful. (3) Numerical Efficiency of the Training - We investigated the numerical efficiency of the SVM training. More specifically, for the primal formulation of the training, we have developed a problem formulation that avoids the linear increase in the number of the constraints as a function of the number of data points. (4) Flexibility of Software Architecture - The software framework for the training of the support vector machines was designed to enable experimentation with different solvers. We experimented with two commonly used nonlinear solvers for our simulations. The primary application of interest for this project has been the sustained optimal operation of particle accelerators at the Stanford Linear Accelerator Center (SLAC). Particle storage rings are used for a variety of applications ranging from 'colliding beam' systems for high-energy physics research to highly collimated x-ray generators for synchrotron radiation science. Linear accelerators are also used for collider research such as International Linear Collider (ILC), as well as for free electron lasers, such as the Linear Coherent Light Source (LCLS) at SLAC. One common theme in the operation of storage rings and linear accelerators is the need to precisely control the particle beams over long periods of time with minimum beam loss and stable, yet challenging, beam parameters. We strongly believe that beyond applications in particle accelerators, the high fidelity and cost benefits of a combined model-based fault estimation/correction system will attract customers from a wide variety of commercial and scientific industries. Even though the acquisition of Pavilion Technologies, Inc. by Rockwell Automation Inc. in 2007 has altered the small business status of the Pavilion and it no longer qualifies for a Phase II funding, our findings in the course of the Phase I research have convinced us that further research will render a workable model-based fault estimation and correction for particle accelerators and industrial plants feasible.

43 PARTICLE ACCELERATORS↗

Parameter Estimation and Confidence Regions in the Method of Light Curve Simulations for the Analysis of Power Density Spectra

The Method of Light Curve Simulations is a tool that has been applied to X-ray monitoring observations of Active Galactic Nuclei (AGN) for the characterization of the Power Density Spectrum (PDS) of temporal variability and measurement of associated break frequencies (which appear to be an important diagnostic for the mass of the black hole in these systems as well as their accretion state). It relies on a model for the PDS that is fit to the observed data. The determination of confidence regions on the fitted model parameters is of particular importance, and we show how the Neyman construction based on distributions of estimates may be implemented in the context of light curve simulations. We believe that this procedure offers advantages over the method used in earlier reports on PDS model fits, not least with respect to the correspondence between the size of the confidence region and the precision with which the data constrain the values of the model parameters. We plan to apply the new procedure to existing RXTE and XMM observations of Seyfert I galaxies as well as RXTE observations of the Seyfert II galaxy NGC 4945.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methods and systems for evaluating and improving distribution-grid observability

This document describes systems and techniques for evaluating and improving distribution-grid observability. These systems and techniques allow engineers to quantify the observability of a distribution grid, which represents an ability to combine actual measurements and various types of computations (e.g., analytics, estimators, forecasters), from a system model. Distribution engineers can also identify islands of observability where operating parameters, including voltages, currents, and power flows, can be determined from available sensor readings. By exclusion, distribution engineers can similarly identify areas of the distribution grid with observability deficiencies that may require additional instrumentation to maintain proper operation. Distribution engineers, using an iterative or automated process, can determine the observability of the system model with new or relocated sensors to generate a sensor allocation plan. The sensor allocation plan can indicate the number and location of sensors to either maximize observability for a fixed sensor cost or minimize sensor cost for predetermined observability.

Reiman, Anthony P.↗

Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System

This paper presents tests of different methods for long term voltage stability analysis based on PMU measurements. In particular, Thevenin Impedance Matching and sensitivity calculation are studied. Simulation are performed in a modified Argentine power system model, to include the main components for studying long term voltage stability. Disconnection of a large Thermal Generating Station causing long-term voltage instability at Gran Buenos Aires Area is studied. It is shown that computing the apparent impedance of Thevenin equivalent at load bus from measurements taken at a single time but at various locations of the transmission corridor produce a significant reduction of the estimation error produce when only local measurements are used. Voltage Stability analysis is performed using a reduced power system model where changing parameters are fully computed through PMU data at each time. Over this reduced power system model, voltage stability index and sensibility calculations are performed.

Gill-Estebez, Pablo↗

Impact of Inverter-Interfaced Renewable Generation on Transient Stability at Varying Levels of Penetration: Preprint

The transient dynamics of conventional power systems are dominated by synchronous generators, and low-inertia inverters serve as the primary interface between power systems and renewable energy resources. Increasing penetration levels of inverter-interfaced generation are impacting the transient dynamics of power systems. In this paper, we attempt to quantify these impacts at different penetration levels. An elementary system including one inverter, one synchronous generator, and one load is studied under different parameter variations to assess the transient dynamics of the system. To quantify transient stability, the post-fault regions of attraction of the system are estimated by the sample-based basin stability approach with parallel computing technology. The simulation results suggest that different inverter penetration levels, inertias of the generator, inverter controller gains, and phase-locked loop controller gains have a clear impact on the regions of attraction as well as on the transient dynamics of proposed systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Individual Load Model Parameter Estimation in Distribution Systems Using Load Switching Events

There currently exists a mature literature on modeling the aggregate load of a distribution feeder by making use of measurements at its feeder-head at substation. The primary application of such feeder-aggregated load models is in sub-transmission or transmission system analysis. However, there is a growing need in practice also to model each individual load across the feeder. If available, such individual load models have applications in power distribution system analysis, e.g., to better integrate distributed energy resources or to improve power quality and reliability. Motivated by this observation, in this paper, we propose a new method for individual load modeling in power distribution systems. It works by using the measurements only at the feeder-head. It takes an innovative approach to analyzing the load switching events across the distribution feeder itself, instead of or in addition to relying on upstream voltage events that are commonly used in feeder-aggregated load modeling. By tracking the downstream load switching events, the proposed method can make a robust estimation of the ZIP load model parameters for all individual loads. The proposed method is examined on small illustrative test-feeders as well as the IEEE 33-bus test system under various operating scenarios. The adverse impact of errors in measurements and system parameters are also investigated on the performance of the developed load modeling method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-Localization of Forced Oscillations in Power Systems

In power systems forced oscillations occur, and identification of these oscillations is important for the proper operation of the system. Two of the parameters of interest in analyzing and addressing forced oscillations are the starting and ending points. To obtain estimates of these parameters, this paper proposes a time-localization algorithm based on the geometric analysis of the sample cross-correlation between the measured data and a complex sinusoid at the frequency of the forced oscillation. Results from simulated and measured synchrophasor data demonstrate the algorithm's ability to accurately estimate the starting and ending points of forced oscillations.

Forced oscillatitons, synchrophasors, power system↗

Determining circuit model parameters from operation data for PV system degradation analysis: $\mathrm{PVPRO}$

Physics-based circuit parameters like series and shunt resistance are essential to provide insights into the degradation status of photovoltaic (PV) arrays. However, calculating these parameters typically requires a full current-voltage characteristic (I-V curve), the acquisition of which involves specific measurement devices and costly methods. Thus, I-V curves of the PV system level are often not available. Here this paper proposes a methodology (PVPRO) to estimate these I-V curve parameters using only operation (string-level DC voltage and current) and weather data (irradiance and temperature). PVPRO first performs multi-stage data pre-processing to remove noisy data. Next, the time-series DC data are used to fit an equivalent circuit single-diode model (SDM) to estimate the circuit parameters by minimizing the differences between the measured and estimated values. In this way, the time evolutions of the SDM parameters are obtained. We evaluate PVPRO on synthetic datasets and find an excellent estimation of both SDM and the key I-V parameters (e.g., open-circuit voltage, short-circuit current, maximum power, etc.) with an average relative error of 0.55%. The performance, especially the extracted degradation rate of parameters, is robust to various measurement noises and the presence of faults. In addition, PVPRO is applied to a 271 kW PV field system. The relative error between the real and estimated operation voltage and current is less than 1%, suggesting that degradation trends are well captured. PVPRO represents a promising open-source tool to extract the time-series degradation trends of key PV parameters from routine operation data.

14 SOLAR ENERGY↗

Estimation of Uncertainties of Wall Temperature Accomplished by Model Calibration Technique Using Small to Large Scale Reflooding Test Data

The fidelity of the prediction can be evaluated by performing validation and uncertainty quantification with suitable test data. Nuclear power plant design and operation must accommodate the uncertainties in predicting system performance, where those uncertainties originating due to initial and boundary conditions, numerics, and modeling uncertainties. To improve the prediction of the reactor system performance, these various sources of uncertainties can be refined through model calibration technique. The objective of this work is to refine the model parameters and to estimate the uncertainties on parameters/responses during reflood phase. To accomplish this experiments should be performed, data collected, and the data utilized to complete model calibration for the thermal-hydraulic input parameters. Simulations were performed using Safety and Performance Analysis Code (SPACE) developed by multiple research institutes in South Korea to predict the thermal hydraulic system behaviors of nuclear power plants. Since existing experimental data were obtained from several tests performed at the small scale, scaling considerations must be addressed during the uncertainty quantification process. (authors)

42 ENGINEERING↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

Low depth quantum circuits for Ising models

A scheme for measuring complex temperature partition functions of Ising models is introduced. Two applications of this scheme are presented. First, through appropriate Wick rotations, those amplitudes can be analytically continued to yield estimates for partition functions of Ising models. Bounds on the estimated error are provided through a central-limit theorem whose validity extends beyond the present context; it holds for example for estimations of the Jones polynomial. The kind of state preparations and measurements involved in this application can be made independent of the system size or the parameters of the system being simulated. Second, the scheme allows to accurately estimate non-trivial invariants of links. Another result concerns the computational power of estimations of partition functions for real temperature classical ferromagnetic Ising models. We provide conditions under which estimating such partition functions allows to reconstruct scattering amplitudes of quantum circuits, making the problem BQP-hard. We also show fidelity overlaps for ground states of quantum Hamiltonians, which serve as a witness to quantum phase transitions, can be estimated from classical Ising model partition functions. Finally, we discuss how accurate corner magnetisation measurements on thermal states of two-dimensional Ising models lead to fully polynomial random approximation schemes (FPRAS) for the partition function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

General expressions and physical origin of the coupling coefficient of arbitrary tuned coupled electromagnetic resonators

The theory and operation of various devices and systems, such as wireless power transfer via magnetic resonant coupling, magneto-inductive wave devices, magnetic resonance spectroscopy probes, and metamaterials can rely on coupled tuned resonators. The coupling strength is usually expressed in terms of the coupling coefficient κ, which can have electrical κ{sub E} and/or magnetic κ{sub M} components. In the current article, general expressions of κ are derived. The relation between the complex Poynting equation in its microscopic form and κ is made and discussed in detail. It is shown that κ can be expressed in terms of the interaction energy between the resonators' modes. It thus provides a general form that combines the magnetic and electric components of κ. The expressions make it possible to estimate the frequencies and fields of the coupled modes for arbitrarily oriented and spaced resonators. Thus, enabling the calculation of system specific parameters such as the transfer efficiency of wireless power transfer systems, resonator efficiency for electron spin resonance probes, and dispersion relations of magneto-inductive and stereo-metamaterials structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Range, resolution and power of THz systems for remote detection of concealed radioactive materials

This paper analyzes parameters required for realizing remote detection of a concealed source of ionizing radiation by observing the occurrence of breakdown in air by a focused wave beam. Production of free electrons and the free electron density in the absence/presence of additional sources of ionization are analyzed. The maximum electron density in the discharge and the time required for this density to return after the discharge back to its stationary level, are estimated. The optimal excess of the power density and the corresponding power level as the function of frequency are determined. It is shown that the optimal frequency of such systems ranges from 0.3 up to 0.8 THz. The paper also determines the range of such systems as the function of the source frequency and power and contains a brief analysis of available sources of microwave, millimeter-wave and THz radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transformer Health Monitoring Using Dissolved Gas Analysis

As integral components of any power plant, transformers supply the generated electricity to the grid. However, a transformer’s cellulose-based paper insulation and the mineral oil in which it is immersed break down over time under standard operating conditions—or more rapidly due to potential faults within the system. As the transformer’s mineral oil breaks down, gases are released that can be measured and monitored. This technical brief exhibits a collection of diagnostic and prognostic techniques that utilities can adopt in lieu of labor-intensive periodic preventive maintenance routines. Furthermore, prognostic models have been incorporated using the latest version of the Institute of Electrical and Electronics Engineers (IEEE) standard (IEEE, 2019) for dissolved gas analysis (DGA), thus expanding it to include estimation of the time to maintenance. Overall, four different methodologies are explained, each of which aids in determining a transformer’s state of health. These methodologies include the Chendong model, the IEEE thermal life consumption model (IEEE, 2012), a diagnostic model for DGA, and a prognostic model for DGA that uses an autoregressive integrated moving average (ARIMA) model. An additional improvement for estimating missing system parameters by using monitoring data (i.e., a tool for parameter estimation utilizing Powell’s method) is presented, enabling the IEEE thermal life consumption model to benefit not only the collaborating power plant, but also the power industry at large.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assigning value to energy storage systems at multiple points in an electrical grid

The ability to define the potential value that energy storage systems (ESS) could generate through various applications in electric power systems, and an understanding of how these values change due to variations in locations, ESS performance and parameters, market structure, utility structures, and valuation methodologies is highly important in advancing ESS deployment. This paper presents the outcome of an effort to assign benefits values, or more precisely ranges of values, to major ESS applications, and summarize and evaluate the capabilities of several available tools currently used to estimate value for specific ESS deployments.

energy storage valuation, balducci, energy storage↗