Short circuit protection for a power distribution system

Sensing circuit detects when the output from a matrix is present and when it should be present. The circuit provides short circuit protection for a power distribution system where the selection of the driven load is accomplished by digital logic.

Owen, J. R., III↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources: Preprint

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Non-Parametric Statistical Analysis of Current Waveforms through Power System Sensors

The protection, control, and monitoring of the power grid is not possible without accurate measurement devices. As the percentage of renewable energy sources penetrating the existing grid infrastructure increases, so do uncertainties surrounding their effects on the everyday operation of the power system. Many of these devices are sources of high-frequency transients. These transients may be useful for identifying certain events or behaviors otherwise not seen in traditional analysis techniques. Therefore, the ability of sensors to accurately capture these phenomena is paramount. In this work, two commercial-grade power system distribution sensors are investigated in terms of their ability to replicate high-frequency phenomena by studying their responses to three events: a current inrush, a microgrid “close-in”, and a fault on the terminals of a wind turbine. Kernel density estimation is used to derive the non-parametric probability density functions of these error distributions and their adequateness is quantified utilizing the commonly used root mean square error (RMSE) metric. It is demonstrated that both sensors exhibit characteristics in the high harmonic range that go against the assumption that measurement error is normally distributed.

47 OTHER INSTRUMENTATION↗

Protection settings optimizer

SAND2023-06672O The Protection Settings Optimizer (PSO) uses system and fault data as inputs to formulate the problem of calculating relay settings as a mixed integer, nonlinear optimization problem (MINLP). The MINLP is solved using a genetic algorithm-based optimizer that attempts to find settings to reduce the relay operating times. The PSO protects the power system by using the steady-state fault voltages and currents, which then calculates the optimal device setting to protect the power system. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Patel, Trupal↗

Study the Protection Improvements for a Weak Grid Area With High IBRs

NLR is collaborating with Florida Power & Light (FPL) and GE to investigate power system stability and protection reliability challenges in a weak-grid region with high penetration of inverter-based resources (IBRs). This presentation will primarily focus on the protection aspects of the study. We will share key insights from this real-world project, including best practices for developing high-fidelity fault study models, establishing a controller-hardware-in-the-loop (CHIL) platform for testing physical relays, identifying system-level protection challenges, and designing enhanced protection schemes to address those issues. Through this discussion, the audience will gain practical understanding of protection studies in IBR-dominated systems, the emerging challenges associated with reduced fault current and altered transient behavior, and effective mitigation strategies. In particular, we will highlight the critical importance of IBR compliance with IEEE 2800-2022 to ensure dependable and secure protection relay operation in modern transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multiple Model Based Approach for Deep Space Power System Fault Diagnosis

Improving protection and health management capabilities onboard the electrical power system (EPS) for spacecraft is essential for ensuring safe and reliable conditions for deep space human exploration. Electrical protection and control technologies on the National Aeronautics and Space Administration's (NASA's) current human space platform relies heavily on ground support to monitor and diagnose power systems and failures. As communication bandwidth diminishes for deep space applications, a transformation in system monitoring and control becomes necessary to maintain high reliability of electric power service. This paper presents a novel approach for on-line power system security monitoring for autonomous deep space spacecraft.

Autonomous Power Controller↗

Hubble Space Telescope On-orbit NiH2 Battery Performance

This paper summarizes the Hubble Space Telescope (HST) nickel-hydrogen (NiH2) battery performance from launch to the present time. Over the life of HST vehicle configuration, charge system degradation and failures together with thermal design limitations have had a significant effect on the capacity of the HST batteries. Changes made to the charge system configuration in order to protect against power system failures and to maintain battery thermal stability resulted in undercharging of the batteries. This undercharging resulted in decreased usable battery capacity as well as battery cell voltage/capacity divergence. This cell divergence was made evident during on-orbit battery capacity measurements by a relatively shallow slope of the discharge curve following the discharge knee. Early efforts to improve the battery performance have been successful. On-orbit capacity measurement data indicates increases in the usable battery capacity of all six batteries as well as improvements in the battery cell voltage/capacity divergence. Additional measures have been implemented to improve battery performance, however, failures within the HST Power Control Unit (PCU) have prevented verification of battery status. As this PCU fault prevents the execution of on-orbit capacity testing, the HST Project has based the battery capacity on trends, which utilizes previous on-orbit battery capacity test data, for science mission and servicing mission planning. The Servicing Mission 38 (SM-3B) in March 2002 replaced the faulty PCU. Following the servicing mission, on-orbit capacity test resumed. A summary of battery performance is reviewed since launch in this paper.

Rao, Gopalakrishna M.↗

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Statistical Spread of Transmission Outages on a Fast Protection Time Scale Based on Utility Data

When there is a fault, the protection system automatically removes one or more transmission lines on a fast time scale of less than one minute. The outaged lines form a pattern in the transmission network. We extract these patterns from utility outage data, determine some key statistics of these patterns, and then show how to generate new patterns consistent with these statistics. The generated patterns provide a new and easily feasible way to model the overall effect of the protection system at the scale of a large transmission system. This new data-driven generative modeling of protection is expected to contribute to simulations of disturbances in large grids so that they can better quantify the risk of blackouts. Analysis of the pattern sizes suggests an index that describes how much outages spread in the transmission network at the fast timescale.

Transmission↗

Challenges, Industry Practice, and Research Opportunities for Protection of IBR-Rich Systems

The objective of this technical report is to outline the challenges of protection design for power systems rich in inverter-based resources (IBRs), synthesize current industrial practices, review new approaches from recent literature, and explore future opportunities in protection. IBRs are experiencing widespread adoption across both transmission and distribution systems. When present in significant quantities, IBRs challenge the performance of many traditional protection functions. To address these issues, the industry has developed sophisticated protection schemes that involve advanced relaying techniques in highly engineered pilot projects. However, these schemes are expensive and time-consuming to develop, build, and test. Researchers have proposed a number of new approaches for protection in IBR-rich distribution systems. Despite their potential, these new approaches do not address some major shortcomings of industry approaches stemming from complexity, practical requirements, and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

Cui, Tao↗

Hybrid Interior-Point/Active-Set SCOPF Algorithms Exploiting Power System Characteristics

These protected data were produced under agreement no. with the U.S. Department of Energy and may not be published, disseminated, or disclosed to others outside the Government until 5 years after development of information under this agreement, unless express written authorization is obtained from the recipient. Upon expiration of the period of protection set forth in this Notice, the Government shall have unlimited rights in this data. This Notice shall be marked on any reproduction of this data, in whole or in part.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Measurement and Analysis of Frequency and RoCoF for Low-Inertia Power Systems

The frequency measurement and rate of change of frequency (RoCoF) calculations are important for active power, frequency control, and frequency-related protection in power system operations. With the rapid decrease in inertia under modern power systems, however, multiple power variations introduced by variable renewable energy bring large RoCoF and introduce oscillations in frequency measurements. To shed light on this issue, this article proposes a frequency measurement and RoCoF analysis technology, as well as the sensitivity analysis for the real low-inertia power grid. First, a real-world event in an island power grid is analyzed as an example, and an event numerical model is estimated considering four uncertainties, including event RoCoF, oscillation magnitude, oscillation frequency, and underfrequency load-shedding threshold. Then, a sensitivity analysis is performed using the Sobol indices method and quasi-Monte Carlo simulations to identify the dominant uncertainties based on the event model. Here, the dominant uncertainties are compared to provide a guideline for the frequency estimation algorithm selection under different event cases. This algorithm is compared with an enhanced zero-crossing algorithm and gives a 3.41% better RoCoF error rate. Finally, an experiment is conducted using universal grid analyzers to validate the simulation results and the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discovery of Signatures, Anomalies, and Precursors in Synchrophasor Data with Matrix Profile and Deep Recurrent Neural Networks (Final Project Report)

The widespread deployment of phasor measurement unit (PMU) across the U.S. together with the burgeoning machine learning technology made it possible to develop data-driven PMU data analytics to improve grid security and reliability in a more insightful and effective manner. Although PMU applications have been explored for over a decade, the representative PMU usage is limited to the bulk power system monitoring mainly due to the data integrity issues associated with PMUs (typically missing, fragmented, and wrongly amplified data). To forge a breakthrough on this stalemate and embrace PMUs for power system control and protection as well, we applied various advanced machine learning and big data analysis technology to the power system event detection and classification as the first step toward the power system control and protection pertaining to grid security enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗