Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Mechanisms for Microseismicity Occurrence Due to CO 2 Injection at Decatur, Illinois: A Coupled Multiphase Flow and Geomechanics Perspective

Here, we numerically investigate the mechanisms that resulted in induced seismicity occurrence associated with CO 2 injection at the Illinois Basin–Decatur Project (IBDP). We build a geologically consistent model that honors key stratigraphic horizons and 3D fault surfaces interpreted using surface seismic data and microseismicity locations. We populate our model with reservoir and geomechanical properties estimated using well-log and core data. We then performed coupled multiphase flow and geomechanics modeling to investigate the impact of CO 2 injection on fault stability using the Coulomb failure criteria. We calibrate our flow model using measured reservoir pressure during the CO 2 injection phase. Our model results show that pore-pressure diffusion along faults connecting the injection interval to the basement is essential to explain the destabilization of the regions where microseismicity occurred, and that poroelastic stresses alone would result in stabilization of those regions. Slip tendency analysis indicates that, due to their orientations with respect to the maximum horizontal stress direction, the faults where the microseismicity occurred were very close to failure prior to injection. These model results highlight the importance of accurate subsurface fault characterization for CO 2 sequestration operations.

58 GEOSCIENCES↗

FORGE STRESS annual report

The project's goal is to combine high-fidelity numerical models and true-triaxial block fracturing tests at high temperatures to understand the relationship between in situ stress, thermal effects, wellbore orientations and hydraulic fracture patterns. The numerical models are calibrated against field data, such as well pressures and microseismic data, and employed to estimate the in situ stress at the FORGE site. Laboratory experiments investigate the complex physics driving hydraulic fracture nucleation in EGS, enhancing understanding of the role of parameters like temperature, well orientation, and stress. Additionally, they are employed to validate some of the numerical tools used in the project. The project will have a significant impact by: (1) improving the characterization of the in-situ stress field at FORGE; (2) demonstrating the use of high-fidelity modeling tools for EGS; (3) providing a unique set of high-temperature hydraulic fracturing results to identify key components for in-situ stress estimation, validate current theories, and propose new ones; (4) offering a validated set of numerical tools within an open-source simulation framework, GEOS, that will be available to any future user.

15 GEOTHERMAL ENERGY↗

Annealing of ion tracks in apatite under pressure characterized in situ by small angle x-ray scattering

Fission track thermochronology is routinely used to investigate the thermal history of sedimentary basins, as well as tectonic uplift and denudation rates. While the effect of temperature on fission track annealing has been studied extensively to calibrate the application of the technique, the effect of pressure during annealing is generally considered to be negligible. However, a previous study suggested elevated pressure results in a significantly different annealing behaviour that was previously unknown. Here, we present a method to study track annealing in situ under high pressure by using synchrotron- based small angle x-ray scattering (SAXS). To simulate fission tracks in a controlled environment, ion tracks were created in apatite from Durango, Mexico using 2 GeV Au or Bi ions provided by an ion accelerator facility. Samples were annealed at 250°C at approximately 1 GPa pressure using diamond anvil cells (DAcs) with heating capabilities. Additional in situ annealing experiments at ambient pressure and temperatures between 320 and 390°C were performed for comparison. At elevated pressure a significantly accelerated annealing rate of the tracks was observed compared with annealing at ambient pressure. However, when extrapolated to geologically relevant temperatures and pressures, the effects become very small. The measurement methodology presented provides a new avenue to study materials behaviour in extreme environments.

58 GEOSCIENCES↗

Pressure Transient Analyses and Poroelastic Modeling of Hydraulic Fracture Dilation for Multiple Injections at the Devine Fracture Pilot Site

Our team has conducted electromagnetic (EM) surveys for the past six years to monitor hydraulic-fracture behavior at the Devine Fracture Pilot Site (DFPS). The sub-horizontal orientation of a shallow hydraulic fracture at the DFPS provides uniform access to the fracture area for interrogation and data collection. Ahmadian et al. (2023) suggested a possible correlation between spatiotemporal changes in the flow rate, bottomhole pressure (BHP), and the observed surface recorded electric field at the DFPS. In this paper, we present the development of poroelastic forward models and pressure transient analyses (PTAs) to support the development of a multiphysics inverse model for these EM surveys. First, we conducted PTAs of the shut-in periods after six injections out of 10 to determine the fracture closure pressure (FCP) or the overburden pressure used in a poroelastic fracture reopening model. Second, we developed a finite-element poroelastic model throughout five injection cycles to include the effect of the cumulative injected volumes due to the previous injections on current fracture dilation in the presence of highly permeable unpropped and propped zones adjacent to the cohesive layer that models fracture reopening. Fracture reopening in this poroelastic model is based on a calibrated traction-separation response using the bottomhole pressure collected in two injection campaigns in 2020 and 2022. We used the outcomes of a previous simulation study of the primary hydraulic-fracturing stimulation to define the dimension of an unpropped fracture zone ahead of the propped fracture area. The PTAs led to FCPs consistent with those obtained using the injection data collected at the DFPS in 2020. Further, these analyses showed that at later injections, the fracture closure occurred at a later time with respect to the shut-in time, inferring the effect of cumulative injected volumes in previous injections. The simulation results show that considering the propped and unpropped fracture zones improves our poroelastic model in predicting the injection-well BHP. The numerical simulation results demonstrate a significant excess pore pressure near the fracture because of the preceding formation loadings by the previous injections. The obtained fracture dilation area and fluid pressure distribution provide a basis to improve the development of a multiphysics inverse model. Furthermore, in an iteratively coupled scheme, this pressure distribution can be introduced into EM models to render a holistic view of the causative mechanisms for the surface signal anomalies.

02 PETROLEUM↗

A robust three-parameter reference curve for condensed phase materials

Many isothermal equations of state lead to numerical problems under tension conditions due to negative bulk modulus. We summarize the properties of four existing models and devise a continuous non-piecewise reference curve to address this issue. The final functional form contains three fitting parameters that are directly related to the bulk modulus and its pressure derivative at the reference state and at infinite pressures. We also include bounds that guarantee the monotonicity of its pressure derivative in all volume space. To demonstrate the qualitative features of each isotherm, we conduct calibrations against experimental data for cyclotetramethylene tetranitramine, magnesium oxide, gold, and platinum. Furthermore, pressure residuals and root mean square deviations show that the proposed functional form is capable of adequately fitting the data compared to other three-parameter models.

36 MATERIALS SCIENCE↗

Poromechanical cohesive interface element with combined Mode I-II cohesive zone elastoplasticity for simulating fracture in fluid-saturated porous media

A combined Mode I-II cohesive zone (CZ) elasto-plastic constitutive model, and a two-dimensional (2D) cohesive interface element (CIE) are formulated and implemented at small strain within an ABAQUS User Element (UEL) for simulating 2D crack nucleation and propagation in fluid-saturated porous media. Here, the CZ model mitigates problems of convergence for the global Newton-Raphson solver within ABAQUS, which when combined with a viscous stabilization procedure allows for simulation of post-peak response under load control for coupled poromechanical finite element analysis, such as concrete gravity dam stability analysis. Verification examples are presented, along with a more complex ambient limestone-concrete wedge fracture experiment, water-pressurized concrete wedge experiment, and concrete gravity dam stability analyses. A calibration procedure for estimating the CZ parameters is demonstrated with the limestone-concrete wedge fracture process. For the water-pressurized concrete wedge fracture experiment it is shown that the inherent time-dependence of the poromechanical CIE analysis provides a good match with experimental force versus displacement results at various crack mouth opening rates, yet misses the pore water pressure evolution ahead of the crack tip propagation. This is likely a result of the concrete being partially-saturated in the experiment, whereas the finite element analysis assumes fully water saturated concrete. For the concrete gravity dam analysis, it is shown that base crack opening and associated water uplift pressure leads to a reduced Factor of Safety, which is confirmed by separate analytical calculations.

97 MATHEMATICS AND COMPUTING↗

Experimental thermal equation of state of B 2–KCl

The alkali halides are often used as optically-transparent pressure-transmitting media and thermal insulators in laser-heated diamond anvil cell experiments. High P-T equations of state for these materials would allow them to be used simultaneously as sensitive in situ pressure markers, making sample preparation and data analysis simpler. KCl is especially useful for this application because its high melting point, crystallographic simplicity, and low electron density are ideal for use in high-temperature X-ray diffraction experiments. However, the high-temperature static equation of state data for this material is limited in pressure to 8 GPa. As experiments routinely exceed 100 GPa in pressure and thousands of Kelvin, it is necessary for the equation of state of KCl to be determined experimentally at these conditions if it is to be used as an equation of state calibrant in the future. This work combines new high-pressure, high-temperature data of the B2 phase of KCl (up to 167 GPa and 2400 K) with the previously published room-temperature data of Dewaele et al. (2012) to produce a Mie-Gruneisen-Debye thermal equation of state for this material. The room temperature equation of state parameters are similar to those reported previously: V 0 = 32.0(3) cm 3 /mole, K 0 = 24(1) GPa and $K$$^{'}_{0}$ = 4.56(5). The thermal parameters, 0 and q, are 2.9(4) and 1.0(1), respectively. While a q of 1 is expected, the 0 is higher than expected from previous calculations, lower pressure experimental data, and the available shockwave data. Here, previously-reported equations of state underestimate the pressure of KCl at high temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quarterly Management Document – FY20, 1st Quarter, Physics-based Creep Simulations of Thick Section Welds in High Temperature and Pressure Applications

During the first quarter of FY20, efforts focused on calibrating a computational model using experimental data. The experimental creep data obtain from specimens containing weld metal exhibit considerable inherent variability making calibration of the computational difficult and may not result in an accurate model.

36 MATERIALS SCIENCE↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

57Fe Mössbauer isomer shift of pure iron and iron oxides at high pressure—An experimental and theoretical study

The 57Fe isomer shift (IS) of pure iron has been measured up to 100 GPa using synchrotron Mössbauer spectroscopy in the time domain. Apart from the expected discontinuity due to the α→ε structural and spin transitions, the IS decreases monotonically with increasing pressure. The absolute shifts were reproduced without semi-empirical calibrations by periodic density functional calculations employing extensive localized basis sets with several common density functionals. However, the best numerical agreement is obtained with the B1WC hybrid functional. Extension of the calculations to 350 GPa, a pressure corresponding to the Earth’s inner core, predicted the IS range of 0.00 to -0.85 mm/s, covering the span from Fe(0) to Fe(VI) compounds measured at ambient pressure. The calculations also reproduced the pressure trend from polymorphs of prototypical iron oxide minerals, FeO and Fe2O3. Analysis of the electronic structure shows a strong donation of electrons from oxygen to iron at high pressure. The assignment of formal oxidation to the Fe atom becomes ambiguous under this condition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science↗

Groundwater and surface water head from 2019 to 2022 at the Tims Branch in Savannah River Site (SRS), South Carolina.

This dataset contains groundwater and surface water head measurements for investigating hydro-biogeochemical processes in Tims Branch at the Savannah River Site, SC. Water levels were monitored using pressure transducers installed in surface water gauges and piezometers across three subsites in Tims Branch, identified as Wfloc, Snon (Snon1 and Snon2), and Sfloc. A barometric pressure logger was deployed in piezometers to correct pressure transducers from atmospheric pressure. Manual water level measurements were taken to calibrate transducer data. The dataset consists of at least paired groundwater and surface water head time series for each subsite, provided as individual CSV files. These data support analyses of surface-groundwater interactions, hydrologic controls on redox processes, and broader synthesis of wetland hydrology at the Savannah River Site.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

Development of Time Lapse VSP Integration Workflow: A Case Study at Farnsworth CO2-EOR Project

Abstract This study aims to develop a 4D Vertical Seismic Profile (VSP) integration workflow to improve the prediction of subsurface stress changes. The selected study site is a 5-spot pattern within the ongoing CO2-EOR operations at the Farnsworth Field Unit FWU in Ochiltree County, Texas. The specific pattern has undergone extensive geological and geomechanical characterization through the acquisition of 3D seismic data, geophysical well logs, and core. This workflow constrains a numerical hydromechanical model by applying a penalty function formed between "modeled" versus "observed" time-lapse compressional and shear seismic velocity changes. Analyses of geophysical logs and ultra-sonic measurements on core exhibit measurable sensitivities to changes in both fluid saturation and mean effective stress. These data are used to develop a site-specific rock physics model and stress-velocity relationship, which inform the numerical models used to generate the "modeled" portion of the penalty function. The "observed" portion of the penalty function is provided by a novel elastic full-waveform inversion of the available 3D baseline and three monitor surveys to produce high-quality estimates of time-lapse compressional and shear seismic velocity changes. The modeling workflow accounts sequentially for fluid substitution and stress impacts. Hydrodynamic and geomechanical properties of the 3D coupled numerical model are estimated through geostatistical integration of well log and core data with 3D seismic inversion products. Changes in seismic velocities due to fluid substitution are computed using the Biot-Gassmann workflow and site-specific rock physics. Stress impacts on time-lapse seismic velocity changes are modeled from the effective stress output of the hydromechanical model and are initially based on the velocity versus effective stress relationship extracted from core mechanical testing. Based on the principle of superposition of seismic wavefields, seismic velocity changes attributed to fluid substitution and that due to changes in mean effective stress are treated as linearly additive. The modeled results are upscaled using Backus averaging to reconcile scale discrepancies between the modeled and measured datasets to formulate the penalty function. This manuscript presents the forward modeling process and concludes that for the base case, the seismic velocity changes due to mean effective stress dominates over the seismic velocity changes attributed to fluid substitution because of the extensive range of the pressure perturbations. Successful minimization of this penalty function calibrates the coupled hydrodynamic geomechanical numerical model and affirms the suitability of acoustic time-lapse measurements such as 4D-VSP for geomechanical calibration.

02 PETROLEUM↗

Design of Sample Holder for Plutonium Coupon Studies

In order to gain better understanding of the plutonium (Pu) corrosion behaviors and reaction kinetics, it is imperative that coupon experiments must be performed on well-defined surfaces. The reactions at the samples’ surfaces have to be properly monitored in terms of reactive gaseous pressures and temperatures. The pressure can be measured by using a pressure gauge, the temperature can be detected with calibrated thermal couples and/or pyrometric camera. These devices do not interfere with the chemistry of the surface reaction. However, to obtain information from the surface reaction, the aggressively machined edge and the back side of the Pu coupons need to be shielded from the applied gases. The coupons are typically made to 5/8 inch in diameter and 0.065 inch in thickness. To this end, a sample holder was designed which can seal the machined edge and the back side of coupons from the exposed gases, thus allowing proper surface reaction. The holder design was fabricated and had been tested with several coupon samples. We have achieved perfect sealing of the machined edge and the back side of the coupons, even when the coupons’ thicknesses are vastly different than the nominal thickness for which the sample holders were fabricated for. This write-up is to document the design of the holder and provide a description of the procedures to properly put the components together.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Understanding Calibration and Error Propagation in Longitudinal and Lateral Manganin Gauge Shock Experiments

Soda-lime glass remains elastic under shock pressures up to approximately 6.5 GPa. In this paper, soda lime glass shock experiments are used to understand the calibration and error propagation in longitudinal and lateral manganin gauge experiments. The errors in the calibration process for both longitudinal and lateral manganin gauge experiments are identified and discussed. Five soda-lime glass experiments up to 3 GPa are analyzed using this refined technique. The results show good agreement between the experimental data and the published calibration by Rosenberg and Moshel. Errors are propagated from the experimental data measurements and the assumptions that are made in the calibration, where the bulk of the error seems to come from uncertainty in the dynamic yield strength of manganin. Finally, the method presented in this paper allows for analysis of dynamic shock experiments with longitudinal and lateral manganin gauges including error propagation.

36 MATERIALS SCIENCE↗

Bayesian calibration of viscous anisotropic hydrodynamic simulations of heavy-ion collisions

Owing to large pressure gradients at early times, standard hydrodynamic model simulations of relativistic heavy-ion collisions do not become reliable until O(1) fm/c after the collision. To address this one often introduces a prehydrodynamic stage that models the early evolution microscopically, typically as a conformal, weakly interacting gas. In such an approach the transition from the prehydrodynamic to the hydrodynamic stage is discontinuous, introducing considerable theoretical model ambiguity. Alternatively, fluids with large anisotropic pressure gradients can be handled macroscopically using the recently developed viscous anisotropic hydrodynamics (VAH). In high-energy heavy-ion collisions VAH is applicable already at very early times, and at later times transitions smoothly into conventional second-order viscous hydrodynamics. Here we present a Bayesian calibration of the VAH model with experimental data for Pb-Pb collisions at the LHC at $\sqrt{^{S}NN}$ = 2.76 A TeV. We find that the VAH model has the unique capability of constraining the specific viscosities of the quark-gluon plasma at higher temperatures than other previously used models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗