Thermoelectric Control Of Temperatures Of Pressure Sensors

Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.

Burkett, Cecil G., Jr.↗

Fiber-optic photoelastic pressure sensor with fiber-loss compensation

A new fiber-optic pressure sensor is described that has high immunity to the effects of fiber-loss variations. This device uses the photoelastic effect to modulate the proportion of the light from each of two input fibers that is coupled into each of two output fibers. This four-fiber link permits two detectors to be used to measure the sensor's responses to the light from each of two independently controlled sources. These four detector outputs are processed to yield a loss-compensated signal that is a stable and sensitive pressure indicator.

Beheim, G.↗

Thin film oxygen partial pressure sensor

The development is described of a laboratory model oxygen partial pressure sensor using a sputtered zinc oxide thin film. The film is operated at about 400 C through the use of a miniature silicon bar. Because of the unique resistance versus temperature relation of the silicon bar, control of the operational temperature is achieved by controlling the resistance. A circuit for accomplishing this is described. The response of sputtered zinc oxide films of various thicknesses to oxygen, nitrogen, argon, carbon dioxide, and water vapor caused a change in the film resistance. Over a large range, film conductance varied approximately as the square root of the oxygen partial pressure. The presence of water vapor in the gas stream caused a shift in the film conductance at a given oxygen partial pressure. A theoretical model is presented to explain the characteristic features of the zinc oxide response to oxygen.

Wortman, J. J.↗

Temperature Induced Voltage Offset Drifts in Silicon Carbide Pressure Sensors

We report the reduction of transient drifts in the zero pressure offset voltage in silicon carbide (SiC) pressure sensors when operating at 600 C. The previously observed maximum drift of +/- 10 mV of the reference offset voltage at 600 C was reduced to within +/- 5 mV. The offset voltage drifts and bridge resistance changes over time at test temperature are explained in terms of the microstructure and phase changes occurring within the contact metallization, as analyzed by Auger electron spectroscopy and field emission scanning electron microscopy. The results have helped to identify the upper temperature reliable operational limit of this particular metallization scheme to be 605 C.

Okojie, Robert S.↗

Thin film devices used as oxygen partial pressure sensors

Electrical conductivity of zinc oxide films to be used in an oxygen partial pressure sensor is measured as a function of temperature, oxygen partial pressure, and other atmospheric constituents. Time response following partial pressure changes is studied as a function of temperature and environmental changes.

Canady, K. S.↗

Evaluation of Silicon Carbide Pressure Sensor in Turbofan Engine Core Exhaust Nozzle

We report the results of the evaluation of single crystal 4H-silicon carbide piezoresistive pressure sensors that were directly inserted at the compressor and core exhaust nozzle exits, in shear contact with the engine-internal flow streams of the NASA DGEN Aeropropulsion Research Turbofan, where the operating temperatures at maximum power were ~230 oC, and ~460 oC, respectively. In addition to demonstrating sensor survivability during this maiden test, the frequency responses of the silicon-carbide sensors at the core-nozzle exit were compared against industry-standard silicon-based piezoresistive pressure transducers that externally placed, using an infinite-tube-probe arrangement. The low-voltage output of these early-development SiC sensors limited the frequency range with an acceptable signal-to-noise-ratio for the current application to less than about 2,500 Hz. The low output of the SiC sensors were due to a conservative burst-pressure diaphragm design that can be optimized to increase the frequency range. The results from this initial campaign offered insights to aspects of the sensor that would require further improvement, with the goal of achieving full-bandwidth capture of engine unsteady pressure fluctuations by direct interrogation of the flow field in hostile-environment engine-core components.

Silicon Carbide↗

Evaluation of SiC Pressure Sensors in Turbofan Engine Core Exhaust Nozzle

We report the results of the evaluation of single crystal 4H-silicon carbide piezoresistive pressure sensors that were directly inserted at the compressor and core exhaust nozzle exits, in shear contact with the engine-internal flow streams of the NASA DGEN Aeropropulsion Research Turbofan, where the operating temperatures at maximum power were ~230°C, and ~460°C, respectively. In addition to demonstrating sensor survivability during this maiden test, the frequency responses of the silicon-carbide sensors at the core-nozzle exit were compared against industry-standard silicon-based piezoresistive pressure transducers that externally placed, using an infinite-tube-probe arrangement. The low-voltage output of these early-development SiC sensors limited the frequency range with an acceptable signal-to-noise-ratio for the current application to less than about 2,500 Hz. The low output of the SiC sensors were due to a conservative burst-pressure diaphragm design that can be optimized to increase the frequency range. The results from this initial campaign offered insights to aspects of the sensor that would require further improvement, with the goal of achieving full-bandwidth capture of engine unsteady pressure fluctuations by direct interrogation of the flow field in hostile-environment engine-core components.

Silicon Carbide↗

Acoustic Diagnosis Of Faulty Dynamic-Pressure Sensors

New use for particle-impact-noise detector found. Dynamic-pressure sensors and accelerometers that tend to produce spurious readings identified with help of particle-impact-noise detector, PIND.

Willis, Martha P.↗

Alpha-Particle Gas-Pressure Sensor

An approximate model was developed to establish design curves for the saturation region and a more complete model developed to characterize the current-voltage curves for an alpha-particle pressure sensor.

alpha-particle↗

Characterization of Silicon Carbide Pressure Sensors at 800 °C

We have performed the initial characterization of single crystal 4H silicon carbide (4H-SiC) pressure sensors to determine the operational reliability over time at 800 °C. Important parameters such as the zero pressure offset, bridge resistance, and pressure sensitivity as they are affected by temperature were extracted. These parameters showed relative stability within the prescribed operational envelop of the sensor at 800 °C. Of significance is the increase in pressure sensitivity with increasing temperature beyond 400 °C, to the extent that the sensitivity at 800 °C was higher than the room temperature value. The implication of this result is that the sensor can be inserted further into the high temperature environment, thereby capturing the wider bandwidth of the pressure transients than currently possible.

Okojie, Robert S.↗

Pressure-Application Device for Testing Pressure Sensors

A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

Source record↗

Improved Reliability of SiC Pressure Sensors for Long Term High Temperature Applications

We report advancement in the reliability of silicon carbide pressure sensors operating at 600 C for extended periods. The large temporal drifts in zero pressure offset voltage at 600 C observed previously were significantly suppressed to allow improved reliable operation. This improvement was the result of further enhancement of the electrical and mechanical integrity of the bondpad/contact metallization, and the introduction of studded bump bonding on the pad. The stud bump contact promoted strong adhesion between the Au bond pad and the Au die-attach. The changes in the zero offset voltage and bridge resistance over time at temperature were explained by the microstructure and phase changes within the contact metallization, that were analyzed with Auger electron spectroscopy (AES) and field emission scanning electron microscopy (FE-SEM).

Okojie, R. S.↗

Self-Correcting Electronically-Scanned Pressure Sensor

High-data-rate sensor automatically corrects for temperature variations. Multichannel, self-correcting pressure sensor can be used in wind tunnels, aircraft, process controllers and automobiles. Offers data rates approaching 100,000 measurements per second with inaccuracies due to temperature shifts held below 0.25 percent (nominal) of full scale over a temperature span of 55 degrees C.

Gross, C.↗

The trade-off characteristics of acoustic and pressure sensors for the NASP

Results of a trade study for the development of pressure and acoustic sensors for use on the National Aerospace Plane (NASP) are summarized. Pressure sensors are needed to operate to 100 psia; acoustic sensors are needed that can give meaningful information about a 200 dB sound pressure level (SPL) environment. Both sensors will have to operate from a high temperature of 2000 F down to absolute zero. The main conclusions of the study are the following: (1) Diaphragm materials limit minimum size and maximum frequency response attainable. (2) No transduction is available to meet all the NASP requirements with existing technology. (3) Capacitive sensors are large relative to the requirement, have limited resolution and frequency response due to noise, and cable length is limited to approximately 20 feet. (4) Eddy current sensors are large relative to the requirement and have limited cable lengths. (5) Fiber optic sensors provide the possibility for a small sensor, even though present developments do not exhibit that characteristic. The need to use sapphire at high temperature complicates the design. Present high temperature research sensors suffer from poor resolution. A significant development effort will be required to realize the potential of fiber optics. (6) Short-term development seems to favor eddy current techniques with the penalty of larger size and reduced dynamic range for acoustic sensors. (7) Long-term development may favor fiber optics with the penalties of cost, schedule, and uncertainty.

Winkler, Martin↗

An oxygen pressure sensor using surface acoustic wave devices

Surface acoustic wave (SAW) piezoelectric devices are finding widespread applications in many arenas, particularly in the area of chemical sensing. We have developed an oxygen pressure sensor based on coating a SAW device with an oxygen binding agent which can be tailored to provide variable sensitivity. The coating is prepared by dissolving an oxygen binding agent in a toluene solution of a copolymer which is then sprayed onto the surface of the SAW device. Experimental data shows the feasibility of tailoring sensors to measure the partial pressure of oxygen from 2.6 to 67 KPa (20 to 500 torr). Potential applications of this technology are discussed.

Leighty, Bradley D.↗

Alpha-Particle Gas-Pressure Sensor

An approximate model was developed to establish design curves for the saturation region and a more complete model developed to characterize the current-voltage curves for an alpha-particle pressure sensor. A simple two-parameter current-voltage expression was developed to describe the dependence of the ion current on pressure. The parameters are the saturation-current pressure coefficient and mu/D, the ion mobility/diffusion coefficient. The sensor is useful in the pressure range between 0.1 and 1000 mb using a 1 - mu Ci(241) Am source. Experimental results, taken between 1 and up to 200 mb, show the sensor operates with an anode voltage of 5 V and a sensitivity of 20 fA/mb in nitrogen.

Buehler, M. C.↗

The effects of pressure sensor acoustics on airdata derived from a High-angle-of-attack Flush Airdata Sensing (HI-FADS) system

The accuracy of a nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was verified for quasi-steady flight conditions up to 55 deg angle of attack during the F-18 High Alpha Research Vehicle (HARV) Program. The system is a matrix of nine pressure ports arranged in annular rings on the aircraft nose. The complete airdata set is estimated using nonlinear regression. Satisfactory frequency response was verified to the system Nyquist frequency (12.5 Hz). The effects of acoustical distortions within the individual pressure sensors of the nonintrusive pressure matrix on overall system performance are addressed. To quantify these effects, a frequency-response model describing the dynamics of acoustical distortion is developed and simple design criteria are derived. The model adjusts measured HI-FADS pressure data for the acoustical distortion and quantifies the effects of internal sensor geometries on system performance. Analysis results indicate that sensor frequency response characteristics very greatly with altitude, thus it is difficult to select satisfactory sensor geometry for all altitudes. The solution used presample filtering to eliminate resonance effects, and short pneumatic tubing sections to reduce lag effects. Without presample signal conditioning the system designer must use the pneumatic transmission line to attenuate the resonances and accept the resulting altitude variability.

Whitmore, Stephen A.↗