Search NASA⌕ Search

SEARCH · Search NASA

Results for “program metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Enhanced Ionization Charge Identification in the Short-Baseline Neutrino Program Neutrino Detectors with Deep Neural Networks

We present a deep neural net-based region of interest detection method (DNN ROI) for signal processing in the liquid argon time projection chambers of the Short-Baseline Neutrino (SBN) Program, SBND and ICARUS. DNN ROI addresses limitations of the traditional wire-by-wire thresholding algorithm by leveraging the full two-dimensional detector readout and cross-plane matching information. To account for detector performance variations, we explore training with augmented samples. We find that DNN ROI outperforms the traditional method in both low-level ROI identification performance and high-level reconstruction metrics for high-energy cosmic and accelerator neutrino interaction products, while also being more robust against detector variations, with or without sample augmentation.

Abratenko, P. [Tufts U.]↗

Preliminary Study on Fine-Grained Power and Energy Measurements on Grace Hopper GH200 with Open-Source Performance Tools

The increasing adoption of tightly integrated, heterogeneous architectures, combined with the slowdown of Moore’s law, has made application power and energy-driven optimizations critical to efficiently use high-performance computing systems. This paper introduces a newly developed open-source toolkit that seamlessly integrates the Linux real-time hardware monitoring program hwmon with the Performance Application Programming Interface and the Score-P performance measurement system, thereby enabling fine-grained power and energy measurements for high-performance computing applications. Our primary target platform is the Wombat test bed, which is a system based on the NVIDIA GH200 superchip. The toolkit can capture transient power peaks with high temporal resolution (50 ms) and, thanks to Score-P integration, can map power metrics to specific code regions, thereby providing actionable information on power-intensive operations and inefficiencies. The toolkit also provides a holistic view of both the power and the energy consumption of the entire GH200 superchip by covering all major components: the Grace CPU, the Hopper GPU, and the I/O subsystem. Experiments that use Locally Self-consistent Multiple Scattering, which is an application for first-principles calculations of materials developed at Oak Ridge National Laboratory, have demonstrated the tool’s ability to identify transient power spikes and uncover opportunities for energy-aware optimizations. Additionally, we introduce a Python-based utility for converting Open Trace Format 2 traces to Parquet format, thus enabling advanced data analysis for numerical integration methods applied to power data for accurate energy profiling.

Hernandez Mendoza, Oscar [ORNL] (ORCID:00000002538↗

Integrating Resilience Planning in Distribution System Planning

Electric utilities, regulators, and stakeholders face increasing risks of severe storms, freezes, floods, and heat waves damaging grid infrastructure and causing power outages—and increasing risks of utility equipment igniting wildfires. At the same time, customer electricity rates have risen substantially in recent years, due in part to replacing aging infrastructure and improving resilience to natural hazards and physical threats. To address these challenges, utilities are beginning to move beyond traditional, siloed planning processes to balance resilience with other fundamental grid objectives such as affordability, reliability, safety, and serving new loads. This study presents a framework for states and utilities that want to advance integration of resilience and distribution planning processes to improve planning efficiency, better prioritize cost-effective grid expenditures, and balance planning objectives. The framework includes 7 key integration points between these planning processes: -Strategy process -Data -Threat assessments -Solution identification and prioritization -Optimization opportunities -Consideration of other grid needs -Metrics Lawrence Berkeley National Laboratory reviewed utility distribution system plans and interviewed subject matter experts to identify emerging practices for each of the 7 integration points. This report presents these practices, which can be used as a guide toward more holistic planning and cohesive investment strategies. It also includes 3 case studies to provide practical examples of how utilities apply such integrated planning processes: two pole hardening programs and one microgrid planning effort. The report concludes by identifying opportunities for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Sensing Approach for Monitoring Tree Health Adjacent to Transmission Corridors

This study presents an initial proof-of-concept for a satellite-based remote sensing approach to identify and monitor potential areas of poor tree health across the entire BPA service territory on an annual basis. We tested three variants of “delta peak NDVI” ( ΔPN ) change detection metrics that express interannual variation in primary productivity relative to a baseline by comparing ΔPN values for known insect/disease disturbances and nearby reference locations. All three metrics showed promise for detecting poor tree health in the year during disturbance, but the metric based on the difference from the long-term (2016-2024) median ( Δ Med PN ) was preferred due to its responsiveness to change in the years during and after disturbance, resilience to interannual variation, and ease of interpretation as being above or below normal. Comparison of Δ Med PN grouped by relative severity of disturbance indicated it was not sensitive enough to detect “low” severity disturbances, as mapped by USGS’s LANDFIRE program, but could distinguish “moderate” and “high” severity disturbances from reference locations. These findings informed selection of a threshold for Δ Med PN , which was combined with areas exhibiting negative NDVI to map potential areas of concern. Visual inspection of before/after high-resolution imagery and NDVI time series showed that many areas of concern aligned with visible signs of defoliation and die-off as well as other types of disturbance (e.g., landslides, logging, road grading, flooding). Some areas of concern are thought to be false detections caused by persistent shadow, and some could not be explained with visual inspection due to spatiotemporal limitations of before/after imagery. In summary, our approach shows promise for large-scale monitoring of tree health adjacent to BPA transmission lines, but additional work is recommended to improve model sophistication and remove noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Powered By ERAD [Slides]

Energy Resilience Analysis for Distribution Power System (ERAD) is a free, open-source Python toolkit for estimating the energy and service impacts of hazards like earthquakes and flooding. It uses a graph-based approach to capture high resolution connectivity among the grid, critical services, and customers and rapidly compute household level metrics and aggregated statistics across large distribution systems. It uses asset fragility curves that relate hazard severity to survival probability for power system equipment including cables, transformers, substations, etc. The tool is designed to be modular and extensible, allowing it to interface with third-party hazard simulators and integrate into broader resilience analysis workflows. ERAD enables researchers, students, communities, distribution utilities, and other stakeholders to understand hazard impacts and evaluate the effectiveness of different programs to improve energy resilience. The webinar was hosted by NLR researcher Aadil Latif.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tools And Methods to Analyze Plant Outage Schedule and Assist Schedulers in Improving Outage Resilience

Refueling outages of nuclear power plants (NPPs) are considered one of the most critical phases throughout the plant lifetime. In such instances, tens of thousands of activities (e.g., maintenance, surveillance) are performed in a short amount of time (typically 2-3 weeks unless major backfitting or modernization projects are carried out) by a large number of crews (e.g., electricians, mechanics) that are hired as contractors. As a consequence, a plant outage can be expensive not only in terms of costs (e.g., contractor labor, material), but also in terms of loss generation since the plant is taken off the grid during the full outage duration (an indicative metric is about 1.2M$/day of loss of revenue). Thus, there is a continuous need to decrease the economic impact of outages on plant finances. This can be done by: decreasing the frequency of plant outages (e.g., from 18 to 24 months), reducing the time to complete the outage, and reducing the risk of outage delays. The Optimization of Outage Activities project under the Risk Informed Systems Analysis Pathway (RISA) sponsored by Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program focuses on developing tools and methods to support NPPs with outage schedule optimization. The developed tools and methods are designed to analyze plant outage schedule with the goal of identify critical elements in the schedule that might pose a high risk of delays. These methods and tools can be considered resource-centric in the sense that they address outage challenges as a resource optimization problem. In this context, resources are either time and crews; outage delays occurs when either (or both) resources are insufficient to complete the set of tasks assigned at a specific time instant of the outage. This report provides details on how plant resources (time and crews) can be allocated in such a way that delays are minimized. In this respect, two classes of methods have been developed: the first one focuses on the time resource and how variability of the time to complete outage tasks may impact outage delays. The second one integrates available resources to assess when dailies activities should be performed such that the risk of outage delays are minimized.

97 MATHEMATICS AND COMPUTING↗

Meeting the Challenges of Modern Transit through the Integration of Traditional Transit, On-Demand Micro-Transit Services and Vehicle Automation - A Case Study in Chandler, Arizona

Current technology trends of vehicle automation, electrification and on-demand transit are providing new tools to develop effective public mobility services, yet need to be balanced with traditional modes to serve the spectrum of demand effectively and efficiently. Automated vehicle transportation network company (TNC) services, better known as 'Robotaxis' are beginning to proliferate and scale across the US, with Waymo as the lead commercial entity. Chandler, AZ was the first fully automated deployment of Waymo technology. Chandler was also one of the first municipalities in Arizona to roll out micro-transit service to its citizens in 2022. At present the Chandler Flex micro-transit program is beginning to partner with Waymo to augment micro-transit services during peak demands, another first in the nation. However, the mix of services in Chandler relies not only on new technology, but also on traditional modes including fixed route transit and para-transit services. These are blended and balanced such that both old and new modes are applied within the context in which each excel. This presentation will provide background on the Chandler, AZ public mobility services, and the performance metrics that govern their use and selection within the spectrum of development and population density as well as socio-demographics within Chandler. Additionally, the behavioral response of the use of unmanned, automated vehicles employed to augment micro-transit is novel, the first in the nation - and initial feedback from public transit constituents in Chandler will be shared.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recent developments and operation of polarized photocathodes at Jefferson Lab

Spin-polarized electron sources are critical to a wide range of accelerator-based applications for nuclear and particle physics. At Thomas Jefferson National Accelerator Facility, they play a central role in delivering high-quality polarized beams for precision nuclear physics experiments and next-generation parity-violation measurements, where stringent control of systematic uncertainties is essential. These sources are also expected to be key components of other initiatives, including the Electron-Ion Collider and the potential future positron capabilities at Jefferson Lab. In this talk, I will present ongoing research and development efforts at Jefferson Lab focused on the design, fabrication and optimization of spin-polarized photocathodes. This includes growth using molecular beam epitaxy (MBE) or metal-organic chemical vapor deposition (MOCVD), along with detailed characterization of their performance metrics, such as quantum efficiency (QE), electron spin polarization and QE anisotropy, all of which are increasingly important metrics for polarized electron sources at Jefferson Lab and the Electron-Ion Collider. Strategies to mitigate QE anisotropy, which is critical for reducing helicity-correlated beam asymmetries in precision experiments such as MOLLER will be highlighted. Finally, I will present recent efforts aimed at improving the operational lifetime of spin-polarized photocathodes in injector environments, particularly under high-voltage conditions in DC electron guns. These developments are essential for enabling reliable, high-performance operation of polarized sources for current and future accelerator programs.

Kachwala, Alimohammed [Thomas Jefferson National A↗

Data-Driven Protection Software to classify fault locations by protective zone in distribution systems with high PV penetration

The software contains (a) the source codes to generate Point-on-Wave (PoW) transient data for any feeder model in Alternative Transient Program (ATP) format. Codes provide options to change different steady state settings, including the loading condition and PV capacity and transient state setting like faults type, location and initiation time (b) data post-processing source code to converted data from native format to COMTRADE, csv, HDF5 (c) Docker container to train CNN to classify fault locations by protective zone. The container takes dataset and other training parameters (sampling rate, training epochs, batch size etc) as input to train CNN. The container writes back the trained CNN model, training and testing metrics and plots to the local workstation

Ramesh, Meghana↗

Life-cycle analysis of offshore macroalgae production systems in the United States

Offshore macroalgae production offers the potential to provide valuable biomass for food, energy, and higher value products without the use of land or freshwater while using excess nutrients and carbon dioxide. To realize this potential, the Macroalgae Research Inspiring Novel Energy Resources program of the Advanced Research Projects Agency-Energy has initiated projects to develop advanced cultivation technologies that enable the cost- and energy-efficient production of macroalgal biomass. Here, this study addresses the life-cycle greenhouse gas emissions and energy return on investment for five U.S. offshore macroalgae production systems designed for deployment at the thousand-hectare scale using a detailed module developed within the GREET life-cycle analysis model for this study. The carbon intensity of macroalgae production system designs, expressed as kg of carbon dioxide equivalent per dry metric ton of algae harvested, vary widely from 49 to 220 and confirm that biomass productivity has the highest degree of sensitivity across the model parameters tested. Regardless of the system designs, the upstream and combustion emissions from fuel use are the key contributor (over 45 %) to carbon intensity, indicating that the use of low-carbon fuels (e.g., renewable diesel) could further reduce greenhouse gas emissions. Further studies need to specify the market opportunity and specific product slates for macroalgae to provide a complete picture of the environmental impacts of macroalgal feedstock.

59 BASIC BIOLOGICAL SCIENCES↗

Establishment of a Vertically Integrated Domestic Manufacturing Process for Production of Substrates Needed for Manufacture of Gas Diffusion Layers

In this project, AvCarb, LLC evaluated the baseline performance metrics of commercial carbon veils and their corresponding Gas Diffusion Layers (GDLs) with the goal of establishing an optimized, vertically integrated production system for wet-laid nonwoven substrates used in gas diffusion media for electrochemical energy storage and conversion devices. Mechanical testing and microstructural characterization were conducted and used to develop a multiscale computational model capable of simulating and predicting the performance of GDLs in fuel cells. Although the project successfully generated foundational transport and modeling data, it was terminated prior to identifying the critical GDL design parameters necessary for full optimization. The program aimed to improve carbon veil fabrication through enhanced fiber dispersion, fiber-fiber adhesion control, and improved web formation, enabling the production of high-quality, uniform substrates. Simulations were intended to guide mixing and solution delivery system design and process conditions, followed by production-scale trials to evaluate fiber dispersion, web uniformity, and mechanical robustness. At full deployment, the proposed production line would have been capable of producing approximately 650,000 m² of carbon veil annually. This capability remains strategically important, as the United States currently lacks a domestic source of wet-laid nonwoven carbon substrates that satisfy the stringent quality requirements for fuel-cell GDLs and electrolyzers representing an ongoing supply-chain vulnerability. Beyond supply-chain benefits, the project established a robust benchmarking dataset for existing commercial carbon veils while advancing next-generation material concepts targeting improved performance and manufacturing consistency.

Olson, Cynthia Lemay↗

Life-Cycle Cost Analysis Framework for Water Efficiency Measures

Life-Cycle Cost Analysis Framework for Water Efficiency Measures: Guidance Designed for Federal Agencies (hereafter referred to as “this report”) provides a technical framework for federal agencies to conduct a life-cycle cost analysis (LCCA) for water efficiency projects in accordance with 42 U.S.C. § 8253. This report leverages insights from the 2023 report, PNNL-34006, Water and Wastewater Annual Price Escalation Rates for Selected Cities Across the United States: 2023 Edition (Unger et al. 2023). The primary objective of this report is to provide a framework to assist federal agencies with evaluating the full economic impact of water efficiency projects by assessing both initial investments and long-term operational benefits. An LCCA can provide a comprehensive view of all costs associated with a water efficiency project, including initial investment, ongoing operations and maintenance (O&M), and eventual disposal or replacement, ensuring the most cost-effective solution is selected. The LCCA methodology outlined in this report enables users to compare base case scenarios with potential alternatives using a standardized present value approach. It incorporates key cost components such as energy, water and wastewater, installation, O&M, and equipment replacement. Additionally, the framework introduces relevant evaluation metrics, such as the net savings and the savings-to-investment ratio, to ensure that water efficiency measures are economically justified over the lifespan of the project. To support practical application, this report also describes various water efficiency strategies that may be analyzed using an LCCA, including plumbing retrofits, irrigation upgrades, alternative water use, and cooling system improvements. By applying this framework, federal agencies can ensure compliance with regulatory mandates while maximizing the return on investment and contributing to resilient water management practices. The information provided in this report is aligned with the Federal Energy Management Program (FEMP) life-cycle cost (LCC) methodology, as conveyed in National Institute of Standards and Technology (NIST) Handbook 135 (Kneifel and Webb 2022). This report is intended to provide relatively high-level guidance, acting as a complement to, rather than a substitute for, that resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SLIA Reference Architecture Models

The SLIA Reference Architecture Models project, sponsored by the DOE CESER Energy CyberSense Program (Oct 2024–Sep 2025), advanced LLNL’s PySCES simulation tool to better support CyTRICS Prioritization and Initial Risk Assessment (PIRA) reference architectures. Key achievements include enhancements to the PySCES transmission substation facility model, expanded asset coverage, and enhancements to the PySCES code base. Software improvements reduced code complexity, migrated PySCES to Python version 3.11, introduced an object-oriented design, and added a schema database for easier updates and validation. New features support device criticality assessments and a more precise parametric simulation mode. Remaining gaps include model validation, workflow limitations, Monte Carlo convergence issues, full device criticality metric implementation, model fidelity, and general software improvements. Continued development is recommended to address these gaps and fully align PySCES with CyTRICS PIRA requirements.

97 MATHEMATICS AND COMPUTING↗

Nuclear Data Sensitivity/Uncertainty Studies of Tantalum-Reflected Systems

Tantalum (Ta) is a refractory metal with high melting point and high corrosion resistance. This makes it useful as a mold material for plutonium casting operations. Unfortunately, there are few criticality benchmarks with high nuclear data sensitivities. Given that, it is desirable to design new experiments to provide additional validation data for nuclear criticality safety, which is the objective of the Thales project. Multiple application models were used to represent process conditions (either normal conditions or credible upset conditions) both at Los Alamos National Laboratory (LANL) and Savannah River Site (SRS). A total of 40 application models were obtained. Given this, it was useful to down-select the number of needed application models. This work documents the down-selection based on several nuclear data sensitivity/uncertainty metrics. In addition to showing the result of the specific down-selection used for the Thales project, this work discusses potential ways to represent a large number of application models with a smaller number of proposed experiment designs.

42 ENGINEERING↗

LDRD FY25 Program Overview

As Lawrence Livermore National Laboratory’s (LLNL’s) Laboratory Directed Research and Development (LDRD) program enters its fifth decade of leading-edge research and development, its impact and importance have never been stronger. The program continues to advance strategic investments in pioneering science, technology, and engineering, ensuring LLNL will be ready to deliver on our mission as it evolves over the coming decades. Investing in LDRD research, and the people who perform this critical work, gives LLNL the ability to sustain our role as a leader in the Department of Energy and National Nuclear Security Administration enterprise. The LDRD program enables high-risk, high-payoff research that anticipates emerging threats and future mission needs. By nurturing the ingenuity of the Lab’s greatest asset, its people, LDRD funding advances not only our research but also grows and nurtures our workforce: engaging future innovators with student mentoring, challenging postdoctoral researchers to apply their skills to support national security, and strengthening the leadership skills of early career staff. This annual report documents how LDRD investments advance LLNL’s science, technology, and engineering across our mission space. To assess LDRD’s impact we track both short and long-term metrics such as peer-reviewed publications, number of students, or professional fellows. In addition to reviewing these metrics, I encourage you to delve deeper into the breadth of science and technology that illustrate the strategic value of this research portfolio. For instance, a recent exploratory research project used advanced manufacturing to construct miniaturized three-dimensional ion traps for a quantum computer with reduced quantum error rates to enable applications that address national security missions and support basic science. Another project has delved into studying detonation by examining deflagration to enhance the safety and security of the nuclear weapons stockpile. LDRD researchers are also deploying AI agents on two of the world’s most powerful supercomputers to automate and accelerate inertial confinement fusion experiments. Other teams are delivering more accurate optical constants to enable improved validation for aluminum to advance atomic and molecular physics models. LDRD-driven discoveries of how metals deform under extreme conditions strengthen our ability to model and design materials for demanding national security environments. National security challenges are increasingly complex and continuously evolving. LDRD focuses our most innovative science and technology on these challenges, ensuring the Laboratory is developing creative, forward-leaning solutions for our nation and the world. The following pages feature highlights of published scientific advances, patents, and honors that stem from LDRD investments. As you read this report, I hope you will understand how these investments position the Laboratory, and our partners, to meet the demands of the decades ahead.

36 MATERIALS SCIENCE↗

SolarAPP+ Performance Review (2023 Data)

The Solar Automated Permit Processing Plus (SolarAPP+) platform is an online portal to facilitate and expedite rooftop solar photovoltaic (PV) and battery storage permitting processes. SolarAPP+ allows PV contractors to upload system specifications, have that information automatically reviewed for code compliance, and receive instant approval for code-compliant systems, reducing authority having jurisdiction (AHJ) staff time needed for review. SolarAPP+ also provides inspection checklists to verify installation practices and adherence to approved designs. SolarAPP+ is available to AHJs at no cost. This report is part of an ongoing series of reviews of SolarAPP+ performance. Consistent with previous performance reviews, we summarize SolarAPP+ adoption trends to date and compare various metrics for PV systems permitted through SolarAPP+ versus systems permitted through traditional AHJ permitting processes. As of the end of 2023, the National Renewable Energy Laboratory (NREL) had contacted over 1,700 AHJs with significant solar permitting volume regarding SolarAPP+. Of those, 793 AHJs had expressed interest in the platform as of the end of 2023. 161 AHJs had begun piloting the platform and 97 of these had publicly launched the platform by the end of 2023. In 2023, 668 installers submitted 18,906 permits through the SolarAPP+ platform, including 4,834 permits submitted as part of a solar plus storage program. SolarAPP+ permits accounted for around 43% of all permits issued in participating AHJs. We compare permitting timelines through SolarAPP+ to traditional AHJ permitting processes to assess the platform's performance. Consistent with previous SolarAPP+ performance reviews, we find that permitting timelines are significantly shorter for SolarAPP+ projects. Based on median timelines, a typical SolarAPP+ project is permitted and inspected 14.5 business days sooner than traditional projects. We estimate that automatic SolarAPP+ permitting saved around 7,200 hours of AHJ staff time in 2023. Finally, we estimate that SolarAPP+ eliminated over 150,000 business days in permitting-related delays in 2023.

14 SOLAR ENERGY↗

Nine Canyon Long-Duration Energy Storage: A Feasibility Study

The Nine Canyon Long Duration Energy Storage (LDES) Feasibility Study explores the technical and economic viability of deploying advanced energy storage technologies at Energy Northwest's (EN) Nine Canyon (9C) Wind Project site in Benton County, Washington. Supported by the Washington State Department of Commerce and the U.S. Department of Energy’s Office of Electricity under its LDES Voucher Program, the study represents a collaborative effort between EN, Pacific Northwest National Laboratory (PNNL), and ARES North America. At the core of this effort is the development of a generalized techno-economic modeling framework and evaluation tool designed to assess the value proposition of LDES projects across a variety of contexts. The modeling tool is technology-agnostic and accommodates user-defined parameters such as rated power, energy duration, round-trip efficiency, capital and operational costs, and dispatch constraints. It also integrates economic inputs, including market prices, energy revenue structures, and financing parameters to evaluate performance through key metrics. The tool provides utilities with a transparent, adaptable platform to support decision-making, investment prioritization, and portfolio planning for various storage technologies. To guide scenario design and interpretation, the study first surveyed the LDES technology landscape, including lithium-ion batteries, flow batteries, non-hydro gravity storage, and thermo-mechanical systems, comparing cost trajectories, technical performance, safety and hazards, materials sourcing and recyclability, and spatial/siting considerations. This literature-grounded review highlights technology trade-offs and reinforces the need to align technology choice with site characteristics, use cases, and project objectives. A companion chapter examines ownership structures (EN ownership, third-party ownership, shared models) and offtake options (energy marketing, capacity/energy PPAs, time-of-use PPAs, block-delivery PPAs, and tolling), where PPAs (power purchase agreements) represent contractual arrangements for buying and selling electricity. The chapter also highlights implications for risk allocation, capital access, operational control, and revenue certainty. The study also evaluates supervisory control and data acquisition (SCADA) and transmission interconnection pathways, options include upgrading the existing SCADA or deploying a dedicated LDES controller, with attention to protection schemes, data telemetry, cybersecurity, and regulatory coordination with BPA. In addition, an ARES-specific geotechnical and hydrology assessment presented in the appendix screens multiple corridors for slope stability, bearing capacity, cut-and-fill magnitude, and stormwater behavior.

25 ENERGY STORAGE↗