Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SU-F-R-06: Traumatic Brachial Plexus Injury Imaging, Developing a Coherent Clinical Protocol From Literature Review Through Practice

Purpose: Medical Physics teams can now play a critical role to help plan and provide studied approaches for traumatic brachial plexus MR imaging (tbpMRI). This is especially important for coordination with uncommon applications, since it is challenging to select the right modality, parameters, and train technologists on the essential components. For this work, we started with a review of the medical literature, performed crossover/volunteer studies to bring tbpMRI to practice with greater image QC and protocol management. Methods: To the best of our knowledge, we reviewed the known searchable domain for tbpMRI. We found 69 total articles since 2000. Articles were evaluated with our published protocol for literature management (LIMES3). Two physicists and two radiologists condensed the information from all articles into a knowledgebase. Results: The initial literature demonstrated great heterogeneity, which was a sign that this area needed greater consistency. Despite inconsistency and imprecision, we extracted the most relevant targets using our long-term experience with protocol development in MSK. We ran volunteers on six different magnets of various field strengths with multiple receiver coils, and rebuilt a coherent protocol for tbpMRI. Our radiologists rated LIMES3 work as superior. We have received referrals from the ER and have conducted four patient evaluations. Conclusion: Traumatic brachial plexus MRI has great possible benefits for patients. This work supports the complexity of tbpMRI scanning. As this is rarely performed, it requires a more diligent protocol workflow, coordination of caregivers, and education within multiple clinical departments. Choosing the correct imaging exam can be critical, as patients can have significant neuropathy and/or paralysis. The LIMES3 protocol is well liked at our institution, and forms the cornerstone of understanding for our work. Our literature management led to a better clinical protocol creation despite the diffuse and inconclusive information presented in the existing medical literature.

60 APPLIED LIFE SCIENCES↗

SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-488: Comparison of the TG-51 and TG-51 Addendum Calibration Protocols

Purpose: To quantify differences between the TG51 and TG51 addendum calibration protocols. Methods: Beam energies of 6X, 6XSRS, 10X, 15X, 23X, 6XFFF, and 10XFFF were calibrated following both the TG51 and TG51 addendum protocols using both a Farmer and a scanning ionization chamber with traceable absorbed dose-to-water calibrations. For the TG51 addendum procedure, the collimating jaws were positioned to define a 10×10cm{sup 2} radiation field, a lead foil was only used for kQ measurements of FFF energies, and a volume-averaging correction was applied based on crossline and inline dose profiles. For the TG51 procedure, the collimating jaws were set to 10×10cm{sup 2} according to the digital readout, and a lead foil was used for kQ measurements of energies greater than 10MV. Results: For beam energies with a flattening filter, absorbed dose-to-water determined by the two protocols differed by 0.1%–0.3%. For FFF beam energies, differences between the protocols were up to 0.2% and 0.8% for the scanning and Farmer ionization chambers, respectively. Differences between the protocols were due to kQ determination, volume-averaging correction, and measurement of raw ionization. Differences in kQ values between the two protocols were up to 0.4% and 0.2% for the scanning and Farmer ionization chambers, respectively. Volume-averaging corrections were less than 0.1% for the scanning ionization chamber, and up to 0.4% and 0.6% for the Farmer ionization chamber in beams with a flattening filter and FFF beams, respectively. Raw ionization measurements differed up to 0.3%±0.07% due to differences in jaw settings. Conclusion: The TG51 and TG51 addendum calibration protocols differed less than 0.3% for the scanning ionization chamber. For the Farmer chamber in FFF energies, volume-averaging corrections of up to 0.6% contributed to calibration differences of up to 0.8%. Failure to verify the radiation field size can produce calibration differences of up to 0.3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-BRA-11: Implementation and Evaluation of a New 3D Dosimetry Protocol for Validating MRI Guided Radiation Therapy Treatments

Purpose: To develop, evaluate and apply a novel high-resolution 3D remote dosimetry protocol for validation of MRI guided radiation therapy treatments (MRIdian by ViewRay™). We demonstrate the first application of the protocol (including two small but required new correction terms) utilizing radiochromic 3D plastic PRESAGE™ with optical-CT readout. Methods: A detailed study of PRESAGE™ dosimeters (2kg) was conducted to investigate the temporal and spatial stability of radiation induced optical density change (ΔOD) over 8 days. Temporal stability was investigated on 3 dosimeters irradiated with four equally-spaced square 6MV fields delivering doses between 10cGy and 300cGy. Doses were imaged (read-out) by optical-CT at multiple intervals. Spatial stability of ΔOD response was investigated on 3 other dosimeters irradiated uniformly with 15MV extended-SSD fields with doses of 15cGy, 30cGy and 60cGy. Temporal and spatial (radial) changes were investigated using CERR and MATLAB’s Curve Fitting Tool-box. A protocol was developed to extrapolate measured ΔOD readings at t=48hr (the typical shipment time in remote dosimetry) to time t=1hr. Results: All dosimeters were observed to gradually darken with time (<5% per day). Consistent intra-batch sensitivity (0.0930±0.002 ΔOD/cm/Gy) and linearity (R2=0.9996) was observed at t=1hr. A small radial effect (<3%) was observed, attributed to curing thermodynamics during manufacture. The refined remote dosimetry protocol (including polynomial correction terms for temporal and spatial effects, CT and CR) was then applied to independent dosimeters irradiated with MR-IGRT treatments. Excellent line profile agreement and 3D-gamma results for 3%/3mm, 10% threshold were observed, with an average passing rate 96.5%± 3.43%. Conclusion: A novel 3D remote dosimetry protocol is presented capable of validation of advanced radiation treatments (including MR-IGRT). The protocol uses 2kg radiochromic plastic dosimeters read-out by optical-CT within a week of treatment. The protocol requires small corrections for temporal and spatially-dependent behaviors observed between irradiation and readout.

60 APPLIED LIFE SCIENCES↗

Determining the Safety and Efficacy of Enhanced Recovery Protocols in Major Oncologic Surgery: An Institutional NSQIP Analysis

Background: Enhanced-recovery (ER) protocols are increasingly being utilized in surgical practice. Outside of colorectal surgery, however, their feasibility, safety, and efficacy in major oncologic surgery have not been proven. This study compared patient outcomes before and after multispecialty implementation of ER protocols at a large, comprehensive cancer center. Methods: Surgical cases performed from 2011 to 2016 and captured by an institutional NSQIP database were reviewed. Following exclusion of outpatient and emergent surgeries, 2747 cases were included in the analyses. Cases were stratified by presence or absence of ER compliance, defined by preoperative patient education and electronic medical record order set-driven opioid-sparing analgesia, goal-directed fluid therapy, and early postoperative diet advancement and ambulation. Results: Approximately half of patients were treated on ER protocols (46%) and the remaining on traditional postoperative (TP) protocols (54%). Treatment on an ER protocol was associated with decreased overall complication rates (20% vs. 33%, p < 0.0001), severe complication rates (7.4% vs. 10%, p = 0.010), and median hospital length of stay (4 vs. 5 days, p < 0.0001). There was no change in readmission rates (ER vs. TP, 8.6% vs. 9.0%, p = 0.701). Subanalyses of high magnitude cases and specialty-specific outcomes consistently demonstrated improved outcomes with ER protocol adherence, including decreased opioid use. Conclusions: This assessment of a large-scale ER implementation in multispecialty major oncologic surgery indicates its feasibility, safety, and efficacy. Future efforts should be directed toward defining the long-term oncologic benefits of these protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems (PNNL-22010) was first issued in November 2012 as a first step toward providing a foundational basis for developing an initial standard for the uniform measurement and expression of energy storage system (ESS) performance. Based on experiences with the application and use of that document, and to include additional ESS applications and associated duty cycles, test procedures and performance metrics, a first revision of the November 2012 Protocol was issued in June 2014 (PNNL-22010 Rev. 1). As an update of the 2014 revision 1 to the Protocol, this document (the March 2016 revision 2 to the Protocol) is intended to supersede the June 2014 revision 1 to the Protocol and provide a more user-friendly yet more robust and comprehensive basis for measuring and expressing ESS performance. This foreword1 provides general and specific details about what additions, revisions, and enhancements have been made to the June 2014 Protocol and the rationale for them in arriving at this March 2016 Protocol (PNNL-22010 Rev. 2).

25 ENERGY STORAGE↗

Towards Provable Security in Industrial Control Systems Via Dynamic Protocol Attestation

Industrial control systems (ICSs) increasingly rely on digital technologies vulnerable to cyber attacks. Cyber attackers can infiltrate ICSs and execute malicious actions. Individually, each action seems innocuous. But taken together, they cause the system to enter an unsafe state. These attacks have resulted in dramatic consequences such as physical damage, economic loss, and environmental catastrophes. This paper introduces a methodology that restricts actions using protocols. These protocols only allow safe actions to execute. Protocols are written in a domain specific language we have embedded in an interactive theorem prover (ITP). The ITP enables formal, machine-checked proofs to ensure protocols maintain safety properties. We use dynamic attestation to ensure ICSs conform to their protocol even if an adversary compromises a component. Since protocol conformance prevents unsafe actions, the previously mentioned cyber attacks become impossible. We demonstrate the effectiveness of our methodology using an example from the Fischertechnik Industry 4.0 platform. We measure dynamic attestation's impact on latency and throughput. Our approach is a starting point for studying how to combine formal methods and protocol design to thwart attacks intended to cripple ICSs.

97 MATHEMATICS AND COMPUTING↗

Effect of formation protocol: Cells containing Si-Graphite composite electrodes

The effect of formation protocol was observed in tests using small pouch cells containing silicon-graphite/Li(Ni 0.5 Mn 0.3 Co 0.2 )O 2 chemistry. The time for the formation protocol was either 13.2 or 186 h for the tested cells. It is demonstrated that the “fast” formation protocol produces cells with similar performance characteristics to that of the “slow” protocol. Moreover, the solid-electrolyte interface layers from both formation protocols are stable and function analogously, albeit with different chemistry. The fast formation protocol may thus allow a more economical route to cell fabrication.

25 ENERGY STORAGE↗

Developing extreme fast charge battery protocols – A review spanning materials to systems

Extreme fast charging (XFC) has become a focal research point in the lithium-battery community over the last several years. As adoption of electric vehicles increases, fast charging has become a key driver in enhancing consumer recharge experience. Recently, the research community has made significant improvements in developing charge protocols to support XFC. New charge protocol designs derived using a combination of advanced, physically derived models, and electrochemical and secondary characterization methods, increase charge acceptance and decrease aging. By coordinating these methods and modifying protocols to account for different material constraints, including lithium plating and cathode particle degradation, novel charge protocols have increased the energy accepted during charging by over 25% in 10 min and increased the charge acceptance prior to a constant-voltage step by approximately 3x. Here, we review several charge-protocol advances, aging factors which are enhanced by XFC and advances which will enable adoption of XFC capable vehicles. These advances include implementing machine learning and other detection algorithms to reduce and classify lithium plating, which is known to significantly degrade cell performance and reduce cell life. The review concludes by discussing full-system fast charge requirements, including electric vehicle service equipment needs for implementing XFC protocols.

25 ENERGY STORAGE↗

Model-Instructed Design of Novel Charging Protocols for the Extreme Fast Charging of Lithium-Ion Batteries Without Lithium Plating

Relatively long recharge time of high-energy density lithium-ion batteries (LIBs) is one of the major obstacles to the widespread deployment of electric vehicles (EVs). Excessive fast charge of LIBs can cause severe safety issues, the most significant of which is lithium plating. In addition to the consumption of cyclable lithium, dendrite-like lithium plating can cause short-circuiting within the cell, which could lead to catastrophic failure. In addition to the developments of advanced electrolytes, active materials and electrodes, the fast charging capability of LIBs can be improved by using optimized charging protocol. In this paper, the Pseudo2D battery model is first used to screen some conventional charging protocols proposed for fast charging, including the constant-current constant-voltage charging (CCCV), constant-power constant-voltage charging (CPCV), multi-stage constant-current charging, and pulse current charging. A semi-optimal charging protocol is then developed by automatically modifying the charge current such that the cell is charged at close-to-maximum current without lithium plating. Based on the features of the semi-optimal protocol, two practical novel fast charging protocols are proposed which allow charging the cell at a higher rate without lithium plating. Through simulation, we show that the no-plating capacity after 10 min charge can be improved by up to ~10.7% compared to CCCV charging for a 2.5 mAh cm -2 cell and ~18.8% for a 4 mAh cm -2 cell, when the proposed charging protocols are used.

25 ENERGY STORAGE↗

Anion exchange membrane test protocol validation

This study presents the validation of protocols for measuring ion exchange capacity (IEC) and alkaline stability of anion exchange membranes (AEMs) for low-temperature water electrolysis. While protocols are often tested within individual laboratories, their results across multiple laboratories with varying equipment, environmental conditions, and personnel qualification remain unverified. The validation involved Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), and University of Oregon (UO) using the same commercially available AEM to assess reproducibility and reliability of the protocols under diverse conditions. For the IEC protocol, results across laboratories were consistent within ±10% of the NMR-determined reference value. The alkaline stability protocol could pose greater challenges due to factors such as variations in sample collection timing, preservation methods, and analytical techniques, but consistent test results for percentage IEC loss were demonstrated across institutions. These results highlight the reliability and applicability of the protocols, emphasizing the importance of validation to ensure consistency in diverse research environments.

08 HYDROGEN↗

How to achieve patient-centered testing: role of the protocol nurse

Introduction: Patient-centered cardiac testing is predicated on choosing the right test for the right patient. We studied the effects of changing from script-driven scheduling to nurse-driven protocoling of stress tests. Methods and Results: A protocol nurse reviewed records before scheduling and communicated with patients and ordering providers if needed. We found that instituting nurse protocolling of all non-imaging (ETT) and nuclear (MPI) stress tests (N = 3071) resulted in protocol changes in 37% of our patients, and reduced the proportion of tests that could not be performed as scheduled by 56% and cancelations by 71% (P < 0.001 for each). These changes were sustained over two successive 6-month periods following a baseline observation period of 6 months. For MPI, the most frequent nurse interventions were re-protocoling as stress-first MPI (12% of tests), changing test location for clinical reasons (13%), changing stress modality (7%), and care coordination (5%). Conclusions: Changing from script-driven scheduling to protocol nursing contributed measurably to patient-centered testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Beam Therapy for Hepatocellular Carcinoma: A Comparison of Three Treatment Protocols

Background: Our previous results for treatment of hepatocellular carcinoma (HCC) with proton beam therapy revealed excellent local control with low toxicity. Three protocols were used to avoid late complications such as gastrointestinal ulceration and bile duct stenosis. In this study, we examined the efficacy of these protocols. Methods and Materials: The subjects were 266 patients (273 HCCs) treated by proton beam therapy at University of Tsukuba between January 2001 and December 2007. Three treatment protocols (A, 66 GyE in 10 fractions; B, 72.6 GyE in 22 fractions; and C, 77 GyE in 35 fractions) were used, depending on the tumor location. Results: Of the 266 patients, 104, 95, and 60 patients were treated with protocols A, B, and C, respectively. Seven patients with double lesions underwent two different protocols. The overall survival rates after 1, 3 and 5 years were 87%, 61%, and 48%, respectively (median survival, 4.2 years). Multivariate analysis showed that better liver function, small clinical target volume, and no prior treatment (outside the irradiated field) were associated with good survival. The local control rates after 1, 3, and 5 years were 98%, 87%, and 81%, respectively. Multivariate analysis did not identify any factors associated with good local control. Conclusions: This study showed that proton beam therapy achieved good local control for HCC using each of three treatment protocols. This suggests that selection of treatment schedules based on tumor location may be used to reduce the risk of late toxicity and maintain good treatment efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure to Adhere to Protocol Specified Radiation Therapy Guidelines Was Associated With Decreased Survival in RTOG 9704-A Phase III Trial of Adjuvant Chemotherapy and Chemoradiotherapy for Patients With Resected Adenocarcinoma of the Pancreas

Purpose: In Radiation Therapy Oncology Group 9704, as previously published, patients with resected pancreatic adenocarcinoma received continuous infusion 5-FU and concurrent radiotherapy (5FU-RT). 5FU-RT treatment was preceded and followed by randomly assigned chemotherapy, either 5-FU or gemcitabine. This analysis explored whether failure to adhere to specified RT guidelines influenced survival and/or toxicity. Methods and Materials: RT requirements were protocol specified. Adherence was scored as per protocol (PP) or less than per protocol (<PP). Scoring occurred after therapy but before trial analysis and without knowledge of individual patient treatment outcomes. Scoring was done for all tumor locations and for the subset of pancreatic head location. Results: RT was scored for 416 patients: 216 PP and 200 <PP. For all pancreatic sites (head, body/tail) median survival (MS) for PP vs. <PP was 1.74 vs. 1.46 years (log-rank p = 0.0077). In multivariate analysis, PP vs. <PP score correlated more strongly with MS than assigned treatment arm (p = 0.014, p = NS, respectively); for patients with pancreatic head tumors, both PP score and gemcitabine treatment correlated with improved MS (p = 0.016, p = 0.043, respectively). For all tumor locations, PP score was associated with decreased risk of failure (p = 0.016) and, for gemcitabine patients, a trend toward reduced Grade 4/5 nonhematologic toxicity (p = 0.065). Conclusions: This is the first Phase III, multicenter, adjuvant protocol for pancreatic adenocarcinoma to evaluate the impact of adherence to specified RT protocol guidelines on protocol outcomes. Failure to adhere to specified RT guidelines was associated with reduced survival and, for patients receiving gemcitabine, trend toward increased nonhematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel protocol to recycle zirconium from zirconium alloy cladding from used nuclear fuel rods

A potential new zirconium recycling protocol has been demonstrated using unirradiated Zircaloy-based claddings and depleted uranium oxide for the chemical removal of zirconium alloy cladding in used nuclear fuel (UNF) rods from light water reactors. This protocol is based on the application of three new scientific findings. First, a new lower temperature chlorination reaction of zirconium with sulfur monochloride is described. Second, the high solubility of zirconium chloride in thionyl chloride is used to separate it from uranium oxide fuel and fission and activation contaminants. Finally, in the third step, the zirconium chloride is purified by simple recrystallization from thionyl chloride. Utilizing sulfur chloride solvents for a lower temperature liquid-based chemical digestion and purification of zirconium alloy claddings reduces technical complications experienced by current high temperature gas phase chlorination strategies, such as contamination of product streams. This novel protocol has been demonstrated on a 3–50 g scale of unirradiated zirconium alloy, with no significant change in the time required for complete chlorination (3–4 h). This zirconium chlorination protocol has also been performed in the presence of depleted uranium oxide pellets. The depleted fuel pellets do not affect zirconium chlorination, and the chlorination protocol does not chemically or physically alter the fuel pellets. Finally, a preliminary description of an industrial protocol to recycle nuclear grade zirconium from UNF rods is presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling HEP to Web size with RESTful protocols: The frontier example

The World-Wide-Web has scaled to an enormous size. The largest single contributor to its scalability is the HTTP protocol, particularly when used in conformity to REST (REpresentational State Transfer) principles. High Energy Physics (HEP) computing also has to scale to an enormous size, so it makes sense to base much of it on RESTful protocols. Frontier, which reads databases with an HTTP-based RESTful protocol, has successfully scaled to deliver production detector conditions data from both the CMS and ATLAS LHC detectors to hundreds of thousands of computer cores worldwide. Frontier is also able to re-use a large amount of standard software that runs the Web: on the clients, caches, and servers. I discuss the specific ways in which HTTP and REST enable high scalability for Frontier. I also briefly discuss another protocol used in HEP computing that is HTTP-based and RESTful, and another protocol that could benefit from it. My goal is to encourage HEP protocol designers to consider HTTP and REST whenever the same information is needed in many places.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Simulation of Logical Magic State Preparation Protocols

Developing space- and time-efficient logical magic state preparation (MSP) protocols will likely be an essential step toward building a large-scale fault-tolerant quantum computer. Motivated by this need, we introduce a scalable method for simulating logical MSP protocols under the standard circuit-level noise model. When applied to protocols based on code-switching, magic state cultivation, and magic state distillation, our method yields a complexity polynomial in (i) the number of qubits and (ii) the nonstabilizerness, e.g., stabilizer rank or Pauli rank, of the target encoded magic state. The efficiency of our simulation method is rooted in a curious fact: every circuit-level Pauli error in these protocols propagates to a Clifford error at the end. This property is satisfied by a large family of protocols, including those that repeatedly measure a transversal Clifford that squares to a Pauli. We provide a proof-of-principle numerical simulation that prepares a magic state using such logical Clifford measurements. Our work enables practical simulation of logical MSP protocols without resorting to approximations or resource-intensive state-vector simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simple protocols for oblivious transfer and secure identification in the noisy-quantum-storage model

We present simple protocols for oblivious transfer and password-based identification which are secure against general attacks in the noisy-quantum-storage model as defined in R. Koenig, S. Wehner, and J. Wullschleger [e-print arXiv:0906.1030]. We argue that a technical tool from Koenig et al. suffices to prove security of the known protocols. Whereas the more involved protocol for oblivious transfer from Koenig et al. requires less noise in storage to achieve security, our ''canonical'' protocols have the advantage of being simpler to implement and the security error is easier control. Therefore, our protocols yield higher OT rates for many realistic noise parameters. Furthermore, a proof of security of a direct protocol for password-based identification against general noisy-quantum-storage attacks is given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗