Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comments on the paper “Eliminating beam-induced depolarizing effects in the hydrogen jet target for high-precision proton beam polarimetry at the Electron-Ion Collider” (Part I)

A critical review of the methodology used in F. Rathmann et al., Phys. Rev. Accel. Beams 29, 021001 (2026), to evaluate beam-induced depolarization of the Atomic Polarized Hydrogen Gas Jet (HJET) target at the Electron–Ion Collider (EIC) is presented. It is shown that several key assumptions underlying that analysis—including the introduction of a photon emission threshold, the application of Fermi’s Golden Rule to coherent hyperfine transitions, the interpretation of power broadening as a physical linewidth increase, and the treatment of spatial magnetic fields—are either incorrect or internally inconsistent. As a consequence, the predicted large depolarization effects are demonstrated to be artifacts of the adopted methodology rather than genuine physical phenomena. A consistent quantum-mechanical treatment based on the time-dependent Schrödinger equation shows that beam-induced depolarization probabilities at the EIC are negligibly small.

43 PARTICLE ACCELERATORS↗

Electron Cooling Experiment for Proton Beams with Intense Space-Charge in IOTA

Electron cooling as a method of creating intense ion beams has a practical upper limit when it comes to the peak phase space density of ion beams which can be achieved in practice. We describe a new experiment to study electron cooling of 2.5 MeV protons at the intensity limit using the Integrable Optics Test Accelerator (IOTA), which is a storage ring dedicated to beam physics research at Fermilab. This system will enable the study of magnetized electron cooling of a proton beam with transverse incoherent tune shifts approaching -0.5 due to the presence of intense space-charge forces. We present an overview of the hardware design, simulations and specific experiments planned for this project.

43 PARTICLE ACCELERATORS↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗

A Wide Dynamic-Range Halo Monitor for 8 GeV Proton Beams at FNAL

Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. At J-PARC, a wide dynamic range monitor was installed in the beam transport line in 2012. The device is a two-dimensional beam profile monitor [*, **], and it has a dynamic range of approximately six digits of magnitude by using Optical Transition Radiation and fluorescence screens. The FNAL accelerator complex has been upgrading through increased beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between the booster and recycler. It will be manufactured in a collaboration between J-PARC and FNAL as a part of the U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. We are redesigning the monitor to satisfy FNAL specifications for beam energy, intensity, and size. The equipment will be manufactured at J-PARC and then shipped to FNAL in 2024. In this report, the design of the device will be described.

43 PARTICLE ACCELERATORS↗

Modeling and design of compact, permanent-magnet transport systems for highly divergent, broad energy spread laser-driven proton beams

Laser-driven (LD) ion acceleration has been explored in a newly constructed short focal length laser beamline at the BELLA petawatt facility (interaction point 2, iP2). For applications utilizing such LD ion beams, a beam transport system is required, which for reasons of compactness be ideally contained within 3 m. While they are generated from a micron-scale source, large divergence and energy spread of LD ion beams present a unique challenge to transporting them compared to beams from conventional accelerators. This study gives an overview of proposed compact transport designs using permanent magnets satisfying different requirements depending on the application for the iP2 laser beamline such as radiation biology, material science, and high-energy density science. These designs are optimized for different parameters such as energy spread and peak proton density according to the application’s need. The various designs consist solely of permanent magnet elements, which can provide high magnetic field gradients on a small footprint. While the field strengths are fixed, we have shown that the beam size is able to be tuned effectively by varying the placement of the magnets. The performance of each design was evaluated based on high-order particle tracking simulations of typical LD proton beams. We also examine the ability of certain configurations to tune and select beam energies, critical for specific applications. A more detailed investigation was carried out for a design to deliver 10 MeV LD accelerated ions for radiation biology applications. With these transport system designs, the iP2 laser beamline is ready to house various application experiments.

43 PARTICLE ACCELERATORS↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Electron Cooling With Space-Charge Dominated Proton Beams at IOTA

We describe a new electron cooler being developed for 2.5 MeV protons at the Integrable Optics Test Accelerator (IOTA), which is a highly re-configurable storage ring at Fermilab. This system would enable the study of magnetized electron cooling in the presence of intense space-charge with transverse tune shifts approaching -0.5 as well as highly non-linear focusing optics in the IOTA ring. We present an overview of the design, simulations and hardware to be used for this project.

43 PARTICLE ACCELERATORS↗

Measurements of displacement cross sections of metals for 120-GeV proton beam irradiation

The number of displacements per atom (dpa) is widely used as an indicator of irradiation damage of materials in proton accelerator facilities. Experiments have been carried out to validate the dpa of metallic materials for protons with energies below 3 GeV. However, measurements of the displacement cross-sections for high-energy protons above 3 GeV have not been carried out and the calculations have not been validated. To validate the displacement cross section of metals in high-energy region, electrical resistivity changes in wires of aluminum, copper and tungsten at 8 K were measured using protons with energies of 120-GeV. The results show that the Norgett-Robinson-Torrens dpa model of the Particle and Heavy Ion Transport Calculation Code overestimates the experimental data. On the other hand, the calculated results using the athermal recombination corrected dpa model were in agreement with the measured displacement cross sections. In the proton energy region above 1 GeV, the displacement cross section is almost constant, which is due to the fact that the damage energy of the material under 1 GeV proton irradiation is almost the same as under 120 GeV proton irradiation. Damage recovery of defects accumulated in the sample was also measured using isochronal annealing: At 80 K, approximately 60 % and 80 % of the damage remains for copper and tungsten, respectively. These results are the same as those obtained from other experiments on proton and neutron irradiation.

43 PARTICLE ACCELERATORS↗

Stable Spin Direction Measurements at RHIC with Polarized Proton Beams

We describe methods for measuring the three-dimensional stable spin vector at the STAR detector (using STAR local polarimetry) and at the proton-Carbon coulomb nuclear interaction polarimeter at the 12 o’clock RHIC interaction region (hereafter the pC polarimeter). These polarimeters can only provide information about the two transverse components of the stable spin direction. If a known, local spin rotation can be generated at the location of the polarimeter, then the longitudinal component can be calculated by comparing the transverse components before and after the rotation. At STAR the stable spin direction can be rotated using the helical dipole spin rotators. At the pC polarimeter, a local horizontal orbital angle is introduced to rotate the stable spin direction. The stable spin direction at the hydrogen jet polarimeter is determined by transporting the spin vector at the pC polarimeter target to the location of the jet using a Zgoubi model. We describe the measurement and analysis methods used and present results of measurements made during RHIC Run 22.

43 PARTICLE ACCELERATORS↗

Optimization of radiochromic film stacks to diagnose high-flux laser-accelerated proton beams

Here, we extend flatbed scanner calibrations of GafChromic EBT3, MD-V3, and HD-V2 radiochromic films using high-precision x-ray irradiation and monoenergetic proton bombardment. By computing a visibility parameter based on fractional errors, optimal dose ranges and transitions between film types are identified. The visibility analysis is used to design an ideal radiochromic film stack for the proton energy spectrum expected from the interaction of a petawatt laser with a cryogenic hydrogen jet target.

Curry, C. B. (ORCID:000000018756181X)↗

Incoherent Dynamics of Intense Proton Beams under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5~MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Incoherent Dynamics of Intense Proton Beams Under Electron Cooling

The minimum emittance of ion beams achieved using electron cooling is limited by the heating processes of Intra Beam Scattering and diffusion driven by resonance crossing of particles due to space-charge. We describe a new experiment to explore the intense space-charge regime with a transverse tune shift approaching -0.5 using 2.5 MeV protons at the Integrable Optics Test Accelerator (IOTA) at Fermilab. We also report on the results from PyORBIT simulations incorporating transverse space-charge and electron cooling with emphasis on the incoherent dynamics of the particles.

43 PARTICLE ACCELERATORS↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of Cherenkov photon production in PbF 2 crystals using proton beams at Fermilab

Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precision measurements of electrons and photons without sacrificing jet energy resolution, given adequate light collection efficiency and separation. This paper presents initial measurements from a program aimed at developing such a calorimeter system for future colliders. Finally, we focus on using PbF 2 crystals to enhance the understanding of Cherenkov light collection, marking the first step in this endeavor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗