Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton exchange membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Adsorption-Engineered Hydrocarbon Ionomers for Durable Proton-Exchange Membrane Fuel Cells

Reducing reliance on perfluoroalkyl substances (PFAS) in proton-exchange membrane fuel cells requires hydrocarbon ionomers that combine high performance with long-term durability, a persistent challenge in catalyst-layer design. Here, we identify oxidation-driven ionomer-catalyst interfacial degradation as a dominant failure pathway in hydrocarbon ionomer-bonded cathodes and introduce an adsorption-engineering strategy to overcome this limitation. The comparison of a commercial sulfonated poly(phenylene) (Pemion) with structurally engineered sulfonated poly(fluorene)s demonstrated that electrode durability is governed by the interplay between ionomer adsorption strength and resistance to oxidative degradation on carbon-supported Pt catalysts. A poly(fluorene) ionomer with mobile alkyl sulfonic acid groups forms resilient interfaces, delivering 1.28 A cm−2 at 0.65 V under fully humidified H2/air conditions (80°C and 150 kPaabs), comparable to Pemion. After 90,000 accelerated potential cycles, the poly(fluorene)-bonded cathode exhibits significantly improved durability, with only 29% performance loss compared to 58% for Pemion; further molecular refinement reduces the loss to 17%, approaching that of Nafion-bonded cathodes (14%). These findings establish adsorption-engineered ionomer design that decouples interfacial anchoring from oxidative degradation as a general strategy for achieving durable, high-performance PFAS-free PEM fuel cell electrodes.

08 HYDROGEN↗

Mechanistic and Mitigation-Strategy Insights into NaCl and CaCl 2 Contamination of Proton-Exchange-Membrane Water Electrolysis Using Continuum Modeling

Cationic contaminants are detrimental to proton-exchange-membrane water electrolyzers (PEMWEs). To obtain insight, a 1-D, nonisothermal, multiphase continuum cell model including cationic contamination is developed. Simulations of steady-state cell performance predict decreased performance due to an increase in kinetic overpotential associated with the hydrogen-evolution reaction, which was attributed to decreased protonic-activity within the cathode catalyst layer from proton supplantation with contaminant cations. The accumulation and extent of cation exchange in the cathode catalyst layer depends on the operating current density due to migration. Simulations of cell recovery of potential suggest that a contaminated cell can recover approximately 78% (450 mV) with 24 h of constant current density operation at 2 A cm –2 , with higher current densities accelerating reduced recovery times. Parametric studies show that anode-side acidification at lower current densities inhibit cation contaminant adsorption, and cathode-side acidification at larger current densities facilitate the expulsion of adsorbed cations; for a cathode-side pH of 6 and 5, the cell can recover an additional 10% and 100% performance, respectively. Overall, the model serves as a framework for modeling other aspects of PEMWE systems to address durability and performance aspects, which can assist in improving the viability of the technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of non-fluorinated proton exchange membranes from Poly(Terphenyl fluorenyl isatin) with fluorene-linked sulfonate groups and microblock structures

Proton exchange membranes (PEMs) are essential components in energy storage and conversion devices, such as fuel cells and electrolyzers. Here, in this study, we developed a series of non-fluorinated PEMs from poly(terphenyl fluorenyl isatin) with fluorene-pendent disulfonate groups. These polymers feature a microblock structure composed of hydrophobic blocks, hydrophilic blocks, and alternating blocks, arising from the differences in reactivity, concentration, and solubility between the hydrophobic p-terphenyl and hydrophilic disulfonated fluorene monomers. As a result, the sulfonic acid groups are unevenly distributed along the polymer chains, forming densely charged regions (IEC = 3.52 meq/g) with large ion clusters and lightly charged regions (IEC = 2.16 meq/g) with small ion clusters. This microstructure, combined with the degree of sulfonation, significantly influences the overall properties of the membranes, including robust mechanical strength (47.1–63.2 MPa), high thermal stability (up to 270 °C), low swelling ratio (18–25% at 80 °C), and high proton conductivity (136–169 mS/cm in deionized water at 80 °C). The PFLSH60 membrane demonstrated comparable fuel cell performance to Nafion 212. Its hydrogen crossover current density was more than two times lower (0.86 mA/cm 2 for PFLSH60 compared to 1.83 mA/cm 2 for Nafion 212) under testing conditions of 80 °C and 100% RH. This significantly reduced crossover improves fuel utilization in fuel cell stacks. This work offers valuable insights into the design of robust, high-performance PEMs by systematically analyzing the relationships between membrane structure, properties, and performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE↗

Mitigating Hydrogen-Induced Degradation of Iridium Anodes in Proton Exchange Membrane Water Electrolyzers

One promising method for reducing precious metal usage in proton exchange membrane water electrolysis is lowering iridium (Ir) loading at the anode. However, low-loading Ir catalysts often suffer from poor stability under high current densities. In this study, hydrogen (H2) crossover from the cathode to the anode is identified as a key degradation pathway. Temperature-programmed reduction confirms the reduction of IrO2 at 80 °C in a hydrogen environment, highlighting the vulnerability of IrO2-based catalysts to H2 exposure. To mitigate this effect, palladium (Pd) is introduced as an anode additive, acting as an H2 oxidation catalyst and mitigating IrO2 reduction. This protective role is verified by inductively coupled plasma optical emission spectroscopy and in situ X-ray absorption spectroscopy, showing significantly suppressed Ir dissolution at 80 °C under H2 flow when an O-covered Pd surface is present at oxygen evolution reaction potentials. Results from the current study identify a new strategy in improving activity and durability of catalysts in electrolyzers.

58 GEOSCIENCES↗

Identifying electrochemical processes by distribution of relaxation times in proton exchange membrane electrolyzers

Distribution of relaxation time (DRT) is used to interpret electrochemical impedance spectroscopy (EIS) for proton exchange membrane (PEM) water electrolyzers, with an attempt to separate overlapped relaxation processes in Nyquist plots. By varying operating conditions and catalyst loadings, four main relaxation peaks arising from EIS can be identified and successfully separated from low to high frequencies as (P1) mass transport, (P2) oxygen evolution reaction kinetics, (P3) reaction kinetics (with faster time constant than P2), and (P4) ionic transport. Here, the shape, height, and frequency of the DRT peaks change with different membrane electrode assembly (MEA) configurations. Electron microscopy reveals distinct features from the cross-sectioned MEAs which verify critical DRT results in that increasing the iridium (Ir)-anode loading from 0.2 mgIr/cm 2 to 1.5 mgIr/cm 2 reduces kinetic losses due to higher site-access; a thick and compacted anode, however, also triggers higher ohmic resistances from membrane/catalyst layer hydration and increases transport losses due to longer ionomer pathways. DRT provides higher resolution to EIS for deconvoluting processes with different relaxation times and the quantification of DRT peaks improves the accounting of total losses from each process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crossover as Determinant for Safety and Performance Tradeoffs in Proton Exchange Membrane Water Electrolyzers

Hydrogen (H2) crossover is a pressing challenge constraining safe and efficient operation of proton exchange membrane water electrolyzers (PEMWEs) especially amongst strides to employ thinner membranes, which enables improved energy efficiency, and elevated cathode pressures, that reduces the energy burden on downstream compressors. Here, we develop a microstructure-aware multicomponent reactive-transport framework that resolves dissolved and gaseous H2 transport pathways and mechanistically links electrode architecture to crossover related safety and performance. We show that operability is co-governed by the cathode catalyst layer (CCL) and the anode porous transport layer (APTL) which sets the H2 crossover flux and the egress capacity respectively. Elevated Pt/C ratio in the CCL suppresses crossover flux by up to 23% while a higher APTL porosity lowers H2 in O2 fraction by 0.6% in the anode effluent. We condense the findings into (cathode pressure-current density) maps overlaid with safety limits and performance targets and ultimately define two safety-performance unified metrics to gauge the size and quality of the operating window. Given the push towards higher pressure and deeper turndown for renewable integration, this study provides mechanistic design guidance to prevent crossover-induced safety risks while preserving the desired performance.

Electrolysis↗

Optimizing Hybrid-Phase IrO2 Catalysts with Ti for Enhanced Oxygen Evolution Reaction for Proton Exchange Membrane Water Electrolysis

To realize a sustainable energy transition, water electrolysis-particularly proton exchange membrane water electrolysis (PEMWE)-holds significant promise. However, practical deployment is hindered by the cost and instability of the anode catalyst, IrO2. Recent studies indicate that tuning the Ir-O bond distance, via doping or composite formation, is key to enhancing the oxygen evolution reaction (OER) performance of IrO2-based electrocatalysts. Herein, a hybrid-phase Ti-incorporated IrO2 electrocatalyst is developed, exhibiting outstanding OER activity (298.8 mV at 100 mA cm-2) and stability over 25 h. This improvement originates from asymmetric interatomic interactions introduced by Ti, as revealed by combined experimental X-ray analyses and theoretical modeling. Ti incorporation induces tensile strain along the z-axis in IrO2 motifs, effectively reducing the average Ir-O bond distance and thereby enhancing OER activity. In situ X-ray absorption spectroscopy further confirms that at 1.5 V (vs. RHE), the elongated Ir-O bond facilitates -OOH* intermediate formation while suppressing Ir dissolution, contributing to superior stability. These findings underscore the critical role of Ir-O bond engineering in balancing activity and durability, offering strategic insights for the rational design of high-performance OER catalysts for renewable energy technologies.

08 HYDROGEN↗

Effect of cell compression on the performance and the structure of proton exchange membrane water electrolyzer (PEMWE) assembly

Here, in the field of water electrolysis, the proton exchange membrane water electrolyzer (PEMWE) is currently the most advanced technology for producing hydrogen without emitting CO 2 . Although PEMWE plants are already in operation, further research is needed to improve cell efficiency and reduce the use of rare materials, such as iridium oxide catalysts for the oxygen evolution reaction (OER). One of the main causes of performance loss in PEMWE is the relatively low electric conductivity of the porous transport layer (PTL) and of the anode catalyst layer, which results in ohmic losses and low catalyst utilization during high current density operation. The objective of this study is to investigate how optimization of the PTL and electrode interface can increase the cell performance. To this end, we tested different cell assemblies using fibrous and sintered PTLs, decreasing membrane thickness, reducing iridium loading, and inserting a microporous layer to increase contact surface area. Electrochemical characterization of each cell configuration was systematically performed at various compression levels as the pressure is a crucial parameter influencing the electrode/PTL contact area. In parallel, X-ray microcomputed tomography (micro-CT) was employed to investigate the effects of cell hydration and compression on the structure of PEMWE components. This study combining electrochemistry and micro-CT imaging presents how optimizing the electrode/PTL contact surface area, minimizes ohmic losses, and enables PEMWE operation with low iridium loading at high current densities.

Catalyst - PTL interface↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

Rational Materials and Structure Design for Improving the Performance and Durability of High Temperature Proton Exchange Membranes (HT-PEMs)

Hydrogen energy as the next-generation clean energy carrier has attracted the attention of both academic and industrial fields. A key limit in the current stage is the operation temperature of hydrogen fuel cells, which lies in the slow development of high-temperature and high-efficiency proton exchange membranes. Currently, much research effort has been devoted to this field, and very innovative material systems have been developed. The authors think it is the right time to make a short summary of the high-temperature proton exchange membranes (HT-PEMs), the fundamentals, and developments, which can help the researchers to clearly and efficiently gain the key information. In this paper, the development of key materials and optimization strategies, the degradation mechanism and possible solutions, and the most common morphology characterization techniques as well as correlations between morphology and overall properties have been systematically summarized.

08 HYDROGEN↗

Recent advances in integrating platinum group metal-free catalysts in proton exchange membrane fuel cells

Platinum group metal (PGM)-free catalysts are promising low-cost materials for the oxygen reduction reaction in proton exchange membrane fuel cells (PEMFCs). A variety of chemical precursors and synthesis methods have been proposed to increase their catalytic activity. In comparison, significantly less attention has been dedicated to the integration of these PGM-free catalysts into operating electrodes by investigating the role of the membrane electrode assembly (MEA) fabrication on the PEMFC performance. Here, we discuss here some remarkable performance improvements recently achieved by tuning catalyst loading, ionomer content, and ink solvent composition, and call for further explorations of the ink processing and MEA fabrication to improve performance.

25 ENERGY STORAGE↗

Using X-ray radiography to study oxygen flow in a proton exchange membrane electrolyzer operating under balanced pressure conditions

Of the various water electrolyzer technologies, the proton exchange membrane electrolyzer (PEMWE) is one of the best solutions for producing clean hydrogen without releasing CO 2 . In order to allow for widespread use of clean hydrogen, it is necessary to decrease its cost, which is intrinsically related to system operation. Current PEMWE plants operate in differential mode, directly pressurizing hydrogen and benefiting from thermodynamic compression, which increases overall system efficiency. However, high differential pressure above 30 bar can cause membrane stress, resulting in membrane creeping and failure. Pressurizing the water and operating at balanced pressure allows hydrogen to be produced at higher pressures while preserving the integrity of the membrane and porous layers. Nevertheless, the impact of pressurizing water on PEMWE performance must be better understood to maximize performance under balanced pressure conditions. Here, this study examined the impact of water pressure on two-phase flow. A high-pressure electrolyzer setup was developed to perform operando X-ray radiography and examine oxygen transport with high temporal resolution. The imaging segmentation process, developed to capture bubble properties in the channel, was applied to a specific experiment. The results clearly showed that as pressure increased up to 30 bars, the initial bubbly flow transitioned to slug flow, which led to channel saturation with oxygen. This work demonstrates that two-phase flow in an electrolyzer can be studied using X-ray radiography, which has the advantages of fast measurements and the ability to probe dense materials, such as those required for pressurized electrolyzers.

Balanced high pressure operation↗

Non-iridium-based electrocatalyst for durable acidic oxygen evolution reaction in proton exchange membrane water electrolysis

Iridium-based electrocatalysts remain the only practical anode catalysts for proton exchange membrane (PEM) water electrolysis, due to their excellent stability under acidic oxygen evolution reaction (OER), but are greatly limited by their high cost and low reserves. Here, in this study, we report a nickel-stabilized, ruthenium dioxide (Ni-RuO 2 ) catalyst, a promising alternative to iridium, with high activity and durability in acidic OER for PEM water electrolysis. While pristine RuO 2 showed poor acidic OER stability and degraded within a short period of continuous operation, the incorporation of Ni greatly stabilized the RuO 2 lattice and extended its durability by more than one order of magnitude. When applied to the anode of a PEM water electrolyser, our Ni-RuO 2 catalyst demonstrated >1,000 h stability under a water-splitting current of 200 mA cm -2 , suggesting potential for practical applications. Density functional theory studies, coupled with operando differential electrochemical mass spectroscopy analysis, confirmed the adsorbate-evolving mechanism on Ni-RuO 2 , as well as the critical role of Ni dopants in stabilization of surface Ru and subsurface oxygen for improved OER durability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constructing Highly Porous Low Iridium Anode Catalysts Via Dealloying for Proton Exchange Membrane Water Electrolyzers

Iridium (Ir) is the most active and durable anode catalyst for the oxygen evolution reaction (OER) for proton exchange membrane water electrolyzers (PEMWEs). However, their large-scale applications are hindered by high costs and scarcity of Ir. Lowering Ir loadings below 1.0 mgcm -2 causes significantly reduced PEMWE performance and durability. Therefore, developing efficient low Ir-based catalysts is critical to widely commercializing PEMWEs. Herein, an approach is presented for designing porous Ir metal aerogel (MA) catalysts via chemically dealloying IrCu alloys. In this study, the unique hierarchical pore structures and multiple channels of the Ir MA catalyst significantly increase electrochemical surface area (ECSA) and enhance OER activity compared to conventional Ir black catalysts, providing an effective solution to design low-Ir catalysts with improved Ir utilization and enhanced stability. An optimized membrane electrode assembly (MEA) with an Ir loading of 0.5 mg Ir cm -2 generated 2.0 A cm -2 at 1.79 V, higher than the Ir black at a loading of 2.0 mg Ir cm -2 (1.63 A cm -2 ). The low-Ir MEA demonstrated an acceptable decay rate of ≈40 µV h -1 during durability tests at 0.5 (>1200 h) and 2.0 A cm -2 (400 h), outperforming the commercial Ir-based MEA (175 µV h -1 at 2.0 mg Ir cm -2 ).

36 MATERIALS SCIENCE↗

Durable hybrid electrocatalysts for proton exchange membrane fuel cells

The low durability of carbon-based non-precious metal electrocatalysts hinders their practical applications in proton exchange membrane fuel cells (PEMFCs). In this study, we rationally design a hybrid Pt-Fe-N-C electrocatalyst with unprecedented durability. It consists of abundant Pt and Fe single atoms homogeneously dispersed on the nitrogen-doped carbon support and a small amount of Pt-Fe alloy nanoparticles. A PEMFC with Pt-Fe-N-C as the cathode shows a larger peak power density (0.75 W cm -2 ) than that with Fe-N-C as the cathode (0.50 W cm -2 ). The remarkable durability of Pt-Fe-N-C is reflected from no noticeable drop in the half-wave potential after 70000 potential cycles between 0.6 and 1.0 V in the liquid cell, and 80% current retention after 85 h of potential hold at 0.4 V in the fuel cell. This work demonstrates the feasibility of improving the durability of Fe-N-C material via ultra-low Pt doping and makes non-precious metal electrocatalysts be close to achieving commercial metrics.

25 ENERGY STORAGE↗

Performance and Durability Investigation of Thin, Low Crossover Proton Exchange Membranes for Water Electrolyzers

The goal of this project was to fabricate and study the performance and durability implications of thin, mechanically reinforced membranes containing gas recombination catalysts (GRCs) for advanced proton exchange membrane water electrolysis (PEMWE) systems. The thinner membranes, optimized for a PEMWE environment, dramatically reduced the proton transport resistance across the membrane, improving the overall efficiency of the PEMWE system. At the same time, the GRC technology was deployed to recombine crossover hydrogen from the cathode with oxygen from the anode to form water within the membrane. This reaction mitigated the buildup of hydrogen in the oxygen stream, ensuring safe operation of the PEMWE system. Capabilities to measure the gas crossover in both an ex-situ screening cell and in operando application testing were developed over the course of the project to track membrane progress and quantify deliverables. State of the art roll to roll manufacturing technologies were leveraged to fabricate the membranes on a commercial scale, where the membrane structure was precisely tuned and GRC distributed within the membrane structure.

08 HYDROGEN↗