Search NASA⌕ Search

SEARCH · Search NASA

Results for “prt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Proton Recoil Telescope Detector for Neutron Spectroscopy

A compact and versatile Proton Recoil Telescope (PRT) detector has been realized to measure neutron energy spectra in the range from few to hundred MeV. The PRT is a position sensitive detector made by: an active multilayer segmented plastic scintillator as neutron to proton converter, two silicon strip detectors for proton energy and position measurement and a final thick CsI(T1) scintillator to measure the residual proton energy. The detector has been tested with the {sup 13}C(d,n) reaction at Laboratori Nazionali del Sud using a 40 MeV deuteron beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current status of the HIBMC and results of representative diseases

The proton radiotherapy (PRT) has been spreading, since 1990 when 250 MeV proton beams with rotation gantry was developed for medical use. On the other hand, carbon-ion radiotherapy (CRT) that has both physical and biological features is available at 4 facilities in the world. HIBMC is the only facility to be able to use both particles. From Apr 2001 to Dec 2008, 2486 patients were treated with PRT in 2030 patients or with CRT in 456. Treatment to the Head and Neck (H and N: in 405 patients), the lung (245), the liver (371), and the prostatic carcinoma (1059) was a major subject. The 2-year local control rates is 72% in H and N (n = 163, T1:9, T2:18, T3:36, T4:79, malignant melanoma 48, adenoid cystic carcinoma 35, squamous cell carcinoma (SCC) 32, adenocarcinoma 14, others 34), 88% in lung (n = 116, T1:59, T2:42, T3:4, T4:6, SCC 30, adenocarcinoma 59, others 27), and 89% in liver cancer (n = 153, Proton: 130, carbon: 23). Biochemical disease free 3-year survival of 291 prostate cancer is 100% in 9 patients with initial prostate-specific antigen (PSA) level < = 4 ng/ml, 99% in 140 with PSA 4.1-10 ng/ml, 90% in 71 with PSA 10.1-20 ng/ml, and 79% in 71 with PSA>20 ng/ml. These results are excellent comparable or superior to those of surgery. Thus, particle therapy is sophisticated radiotherapy, however the only problem to prohibit the progress is high costs for construction and maintenance. Facilities at which both proton and carbon ion beams can be used, including the HIBMC, have to investigate the differential use. We started clinical randomized trial to compare both ion beams, and started biological examinations in a project aiming at the development of a laser driven proton radiotherapy. We stated about the current status of the HIBMC and the results of representative diseases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apparent absence of a proton beam dose rate effect and possible differences in RBE between Bragg peak and plateau

Purpose: Respiration-gated irradiation for a moving target requires a longer time to deliver single fraction in proton radiotherapy (PRT). Ultrahigh dose rate (UDR) proton beam, which is 10-100 times higher than that is used in current clinical practice, has been investigated to deliver daily dose in single breath hold duration. The purpose of this study is to investigate the survival curve and relative biological effectiveness (RBE) of such an ultrahigh dose rate proton beam and their linear energy transfer (LET) dependence. Methods: HSG cells were irradiated by a spatially and temporally uniform proton beam at two different dose rates: 8 Gy/min (CDR, clinical dose rate) and 325 Gy/min (UDR, ultrahigh dose rate) at the Bragg peak and 1.75 (CDR) and 114 Gy/min (UDR) at the plateau. To study LET dependence, the cells were positioned at the Bragg peak, where the absorbed dose-averaged LET was 3.19 keV/{mu}m, and at the plateau, where it was 0.56 keV/{mu}m. After the cell exposure and colony assay, the measured data were fitted by the linear quadratic (LQ) model and the survival curves and RBE at 10% survival were compared. Results: No significant difference was observed in the survival curves between the two proton dose rates. The ratio of the RBE for CDR/UDR was 0.98{+-}0.04 at the Bragg peak and 0.96{+-}0.06 at the plateau. On the other hand, Bragg peak/plateau RBE ratio was 1.15{+-}0.05 for UDR and 1.18{+-}0.07 for CDR. Conclusions: Present RBE can be consistently used in treatment planning of PRT using ultrahigh dose rate radiation. Because a significant increase in RBE toward the Bragg peak was observed for both UDR and CDR, further evaluation of RBE enhancement toward the Bragg peak and beyond is required.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-12: Proton Radiation Therapy for Left-Sided Breast Cancer: LET and RBE Considerations for Cardiac Toxicity

Purpose: Increased risk of coronary artery disease has been documented for patients treated with radiation for left-sided breast cancer. Proton therapy (PRT) has been shown to significantly decrease cardiac irradiation, however variations in relative biological effectiveness (RBE) have been ignored so far. In this study we evaluate the impact of accounting for RBE variations on sensitive structures located within high linear energy transfer (LET) areas (distal end) of the proton treatment fields, for this treatment site. Methods: Three patients treated in our institution with PRT for left-sided breast cancer were selected. All patients underwent reconstructive surgery after mastectomy and treated to a total dose of 50.4Gy with beam(s) vertical to the chest wall. Dose and LET distributions were calculated using Monte Carlo (MC-TOPAS - TOol for PArticle Simulation). The LET-based, variable-RBE-weighted dose was compared to the analytical calculation algorithm (ACA) and MC dose distributions for a constant RBE of 1.1, based on volume histograms and mean values for the target, heart and left anterior descending coronary artery (LAD). Results: Assuming a constant RBE and compared to the ACA dose, MC predicted lower mean target and heart doses by 0.5% to 2.7% of the prescription dose. For variable RBE, plan evaluation showed increased mean target dose by up to 5%. Mean variable-RBE-weighted doses for the LAD ranged from 2.7 to 5.9Gy(RBE) among patients increased by 41%–64.2% compared to constant RBE ACA calculation (absolute dose: 1.7–3.9Gy(RBE)). Smaller increase in mean heart doses was noticed. Conclusion: ACA overestimates the target mean dose by up to 2.7%. However, disregarding variations in RBE may lead to significant underestimation of the dose to sensitive structures at the distal end of the proton treatment field and could thus impact outcome modeling for cardiac toxicities after proton therapy. These results are subject to RBE model and parameter uncertainties.

60 APPLIED LIFE SCIENCES↗

Response time correlations for platinum resistance thermometers in flowing fluids

The thermal response of two types of Platinum Resistance Thermometers (PRT's), which are being considered for use in the National Transonic Wind Tunnel Facility, were studied. Response time correlations for each PRT, in flowing water, oil and air, were established separately. A universal correlation, tau WOA = 2.0 + 1264, 9/h, for a Hy-Cal Sensor (with a reference resistance of 100 ohm) within an error of 20% was established while the universal correlation for the Rosemount Sensor (with a reference resistance of 1000 ohm), tau OA = 0.122 + 1105.6/h, was found with a maximum percentage error of 30%. The correlation for the Rosemount Sensor was based on air and oil data only which is certainly not sufficient to make a correlation applicable to every condition. Therefore, the correlation needs more data to be gathered in different fluids. Also, it is necessary to state that the calculation of the parameter, h, was based on the available heat transfer correlations, whose accuracies are already reported in literature uncertain within 20-30%. Therefore, the universal response constant correlations established here for the Hy-Cal and Rosemount sensors are consistent with the uncertainty in the input data and are recommended for future use in flowing liquids and gases.

Pandey, D. K.↗

Shuttle Systems 3-D Applications: Application of 3-D Graphics in Engineering Training for Shuttle Ground Processing

This project illustrates an animation of the orbiter mate to the external tank, an animation of the OMS POD installation to the orbiter, and a simulation of the landing gear mechanism at the Kennedy Space Center. A detailed storyboard was created to reflect each animation or simulation. Solid models were collected and translated into Pro/Engineer's prt and asm formats. These solid models included computer files of the: orbiter, external tank, solid rocket booster, mobile launch platform, transporter, vehicle assembly building, OMS POD fixture, and landing gear. A depository of the above solid models was established. These solid models were translated into several formats. This depository contained the following files: stl for sterolithography, stp for neutral file work, shrinkwrap for compression, tiff for photoshop work, jpeg for Internet use, and prt and asm for Pro/Engineer use. Solid models were created of the material handling sling, bay 3 platforms, and orbiter contact points. Animations were developed using mechanisms to reflect each storyboard. Every effort was made to build all models technically correct for engineering use. The result was an animated routine that could be used by NASA for training material handlers and uncovering engineering safety issues.

Godfrey, Gary S.↗

Passive radiative thermostat

A passive radiative thermostat (PRT) is provided. The PRT comprises a phase-change part comprising a thermochromic phase change material; and a wavelength-selector part designed to create electromagnetic resonances in a wavelength range. The wavelength range may include the visible range, the near-infrared range, or the mid-infrared range. The wavelength-selector part may include an electromagnetic cavity resonator or an electromagnetic plasmonic resonator. Further, the phase-change part may include a thermochromic film; and the wavelength-selector part may include a dielectric spacer.

de Melo Kort-Kamp, Wilton Junior↗

Abu Dhabi's Masdar project: dazzling? or Just a mirage?

The Masdar project is to build a self-contained economic zone creating 70,000 jobs and eventually housing as many as 40,000 residents in the middle of the desert by 2016. The community, which is envisioned to house a science and technology park and housing, is designed to be carbon neutral and virtually waste-free. Two-thirds of the power is to come from a 10 MW solar farm, and nearly all water is to be recycled and reused. There will be virtually no waste, as all packaging and material are to be recycled, used for power generation or turned into compost. The car-free zone will be served by advanced personal rapid transit (PRT) vehicles that will zip residents around the 6.5-square-kilometer area. The problem with Masdar is not so much what goes inside it, but rather what is outside. Masdar is unlikely to change the image of Abu Dhabi as the most carbon-intensive place on earth.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic Properties Of Pr-T-X Compounds (T = d-elements, X = Si, Ge)

The crystal electric field (CEF) effects lead to exotic behaviour in some of the Pr-compounds. Superconductivity in heavy fermion PrOs{sub 4}Sb{sub 12} is mediated by quadrupolar fluctuations involving low lying crystal field excitations. In our search for novel and interesting Pr-compounds we have synthesized PrT{sub 2}X{sub 2}, PrTGe{sub 3} and Pr{sub 2}T{sub 3}Ge{sub 5} series of compounds. Some of these compounds order magnetically while others do not. We present highlights of our recent results on Pr-compounds. Notable among these are anomalously high T{sub N} and strong magnetocrystalline anisotropy in PrRh{sub 2}Si{sub 2}, large magnetoresistance in Pr{sub 2}Pd{sub 3}Ge{sub 5} and excitonic mass enhancement in Pr{sub 2}Rh{sub 3}Ge{sub 5}.

36 MATERIALS SCIENCE↗

Erratum: ?Stimulated Brillouin Backscattering and Ion Acoustic Wave Secondary Instability? [Phys. Plasmas 16, 032701 (2009)]

This Erratum addresses errors that occurred in some of the analysis in our recent publication (Ref. 1). The main elements of Ref. 1 are (1) the presentation of kinetic simulations of simulated Brillouin backscattering (SBS) and the accompanying secondary instability of the primary SBS ion acoustic wave (IAW) with and without the inclusion of the second harmonic of the primary IAW; (2) analyses of the four-wave (primary IAW, low-frequency IAW, and two sidebands of the primary IAW) and seven-wave (includes the second harmonic of the primary IAW and its two sidebands, as well as the four waves defined in the foregoing) dispersion relations for the secondary IAW instability; (3) comparisons of the results of solving the dispersion relations to the two particle simulations; (4) mode coupling calculations for SBS and the four-wave system of IAWs that model the particle simulations; and (5) a discussion and summary. However, the simplified 7-wave dispersion relation used in Ref. 1 propagated a typographical error in Eq.(44) in Ref. 2, the Pesme, Riconda, and Tikhonchuk (PRT) paper. This Erratum corrects Eq.(44) of Ref. 2 (discussed in more detail in an Erratum3 for Ref. 2) and revises Sec. IV of Ref. 1 by correcting the analysis and comparisons of the 4-wave and 7-wave dispersion relations, and the comparison of the 7-wave dispersion relation to the particle simulations. We find that the results of the corrected 7-wave dispersion relation are not profoundly different from the corresponding results in Ref. 1 and the 7-wave growth rates of the most unstable modes are more similar to the results of the 4-wave dispersion relation. The main results of Ref. 1 are unchanged: (1) the particle simulations exhibit a secondary IAW instability that is a modulational instability involving parallel and obliquely propagating IAWs; (2) the two types of particle simulation exhibit similar spectra, and the second harmonic IAW is a transient feature in the first particle simulation that is not well differentiated from the noise in the streak spectra shown in Ref. 1; (3) the 4-wave dispersion relation fits the simulation data relatively well, and only the 4-wave dispersion relation is applicable to the simulation with the second harmonic IAW suppressed; (4) the results of the 7-wave dispersion relation do not differ profoundly from the 4-wave results for the modulational instability when frequency mismatch effects are included; and (5) it is problematic justifying the application of the 7-wave dispersion relation even to the first particle simulation because the second harmonic signal is either transient or weak. The 7-wave dispersion relation is not a primary focus of Ref. 1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of non-Kramers doublets in magnetic field in PrNi 2 Cd 20 and PrPd 2 Cd 20

Praseodymium-based 1-2-20 cage compounds PrT 2 X 20 (T is generally Ti, V, Nb, Ru, Rh, Ir; and X is either Al, Zn, or Cd) provide yet another platform to study nontrivial electronic states of matter ranging from topological and magnetic orders to unconventional multipolar orders and superconductivity. In this paper, we report measurements of the electronic heat capacity in two Pr-based 1-2-20 materials: PrNi 2 Cd 20 and PrPd 2 Cd 20 . We find that the lowest-energy multiplet of the Pr 4f 2 valence configuration is a Γ 3 non-Kramers doublet and the first excited triplet is assumed to be a magnetic Γ 5 . By analyzing the dependence of the energy splitting between the ground and first excited singlet states on an external magnetic field, we found that the maximum in the heat capacity corresponding to the Schottky anomaly in PrPd 2 Cd 20 , unlike PrNi 2 Cd 20 , shows a pronounced linear dependence on an external magnetic field at higher field values. In conclusion, this effect is associated with the exchange interactions between the field-induced magnetic dipole moments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TH-AB-BRA-02: Automated Triplet Beam Orientation Optimization for MRI-Guided Co-60 Radiotherapy

Purpose: MRI guided Co-60 provides daily and intrafractional MRI soft tissue imaging for improved target tracking and adaptive radiotherapy. To remedy the low output limitation, the system uses three Co-60 sources at 120° apart, but using all three sources in planning is considerably unintuitive. We automate the beam orientation optimization using column generation, and then solve a novel fluence map optimization (FMO) problem while regularizing the number of MLC segments. Methods: Three patients—1 prostate (PRT), 1 lung (LNG), and 1 head-and-neck boost plan (H&NBoost)—were evaluated. The beamlet dose for 180 equally spaced coplanar beams under 0.35 T magnetic field was calculated using Monte Carlo. The 60 triplets were selected utilizing the column generation algorithm. The FMO problem was formulated using an L2-norm minimization with anisotropic total variation (TV) regularization term, which allows for control over the number of MLC segments. Our Fluence Regularized and Optimized Selection of Triplets (FROST) plans were compared against the clinical treatment plans (CLN) produced by an experienced dosimetrist. Results: The mean PTV D95, D98, and D99 differ by −0.02%, +0.12%, and +0.44% of the prescription dose between planning methods, showing same PTV dose coverage. The mean PTV homogeneity (D95/D5) was at 0.9360 (FROST) and 0.9356 (CLN). R50 decreased by 0.07 with FROST. On average, FROST reduced Dmax and Dmean of OARs by 6.56% and 5.86% of the prescription dose. The manual CLN planning required iterative trial and error runs which is very time consuming, while FROST required minimal human intervention. Conclusions: MRI guided Co-60 therapy needs the output of all sources yet suffers from unintuitive and laborious manual beam selection processes. Automated triplet orientation optimization is shown essential to overcome the difficulty and improves the dosimetry. A novel FMO with regularization provides additional controls over the number of MLC segments and treatment time. Varian Medical Systems; NIH grant R01CA188300; NIH grant R43CA183390.

60 APPLIED LIFE SCIENCES↗

Los Alamos National Laboratory and Lawrence Livermore National Laboratory Plutonium Sustainment Monthly Program Report, October 2012 (Revision 8)

In October of 2012 the Plutonium Sustainment program at LANL completed or addressed the following high-level activities: 1) Completed Pollux shipment to DAF in early October in accordance with the Gemini Core Team's schedule. Unpacked Pollux at DAF and supported Gemini team in various tests and inspections. Pollux test and measurement results were all acceptable. Pollux is expected to g to U1A in November. Pu Sustainment no longer has any obligations associated with the Gemini experiment. 2) Presented to Dr. Cook on the successful assembly of the Pollux experimental device as part of the Gemini series. 3) Supported the release of the FY12 Pu Sustainment Program Implementation Plan. 4) Established the FY12 program baseline and allocated funds accordingly. 5) Meetings: a. Hosted the Pu Containment 4 th Quarter Program Review; b. Hosted the Power Supply PRT; c. Traveled to KCP for the W87 Pit IPT. All four MRT L2 Milestones (4622-4625) associated with Plutonium Sustainment are on track for success in FY13.

Nuclear Physics & Radiation Physics(73)↗

McCallen Professional Research and Teaching Leave Report

This end of assignment report for a Professional Research and Teaching (PRT) Leave award includes the attached assessment of success by the host organization, University of California Davis (UCD). The following summarizes the accomplishments and attached are a selection of documented items.

36 MATERIALS SCIENCE↗

Results of Surveys for Special Status Reptiles at the Site 300 Facilities of Lawrence Livermore National Laboratory

The purpose of this report is to present the results of a live-trapping and visual surveys for special status reptiles at the Site 300 Facilities of Lawrence Livermore National Laboratory (LLNL). The survey was conducted under the authority of the Federal recovery permit of Swaim Biological Consulting (PRT-815537) and a Memorandum of Understanding issued from the California Department of Fish and Game. Site 300 is located between Livermore and Tracy just north of Tesla road (Alameda County) and Corral Hollow Road (San Joaquin County) and straddles the Alameda and San Joaquin County line (Figures 1 and 2). It encompasses portions of the USGS 7.5 minute Midway and Tracy quadrangles (Figure 2). Focused surveys were conducted for four special status reptiles including the Alameda whipsnake (Masticophis lateralis euryxanthus), the San Joaquin Whipsnake (Masticophis Hagellum ruddock), the silvery legless lizard (Anniella pulchra pulchra), and the California horned lizard (Phrynosoma coronanum frontale).

54 ENVIRONMENTAL SCIENCES↗

Mechanical Devices Readiness FY04.0402.1

This Advanced Design and Production Technologies (ADAPT) project funded production process and tooling improvements to meet and sustain rate production for the program mechanism assemblies. Techniques were developed to allow evaluation and rework of sealed mechanisms that will result in prevention of the scrapping of future mechanisms. Future system mechanisms will likely be smaller with tighter tolerance parts that will require improved inspection equipment and techniques. During the latter phase of this project, the ISL (Intent Stronglink) PRT (Product Realization Team) developed designs and manufacturing processes at Sandia and at multiple KCP (Kansas City Plant) vendors, to produce glass ceramic headers to replace the brazed ceramic headers in the ISL. This achievement will result in significant production costs savings (unit cost and product scrap due to leaking headers).

42 ENGINEERING↗

Complete Inactivation of Blood Borne Pathogen Trypanosoma cruzi in Stored Human Platelet Concentrates and Plasma Treated With 405 nm Violet-Blue Light

The introduction of pathogen reduction technologies (PRTs) to inactivate bacteria, viruses and parasites in donated blood components stored for transfusion adds to the existing arsenal toward reducing the risk of transfusion-transmitted infectious diseases (TTIDs). We have previously demonstrated that 405 nm violet-blue light effectively reduces blood-borne bacteria in stored human plasma and platelet concentrates. In this report, we investigated the microbicidal effect of 405 nm light on one important bloodborne parasite Trypanosoma cruzi that causes Chagas disease in humans. Our results demonstrated that a light irradiance at 15 mWcm -2 for 5 h, equivalent to 270 Jcm -2 , effectively inactivated T. cruzi by over 9.0 Log 10 , in plasma and platelets that were evaluated by a MK2 cell infectivity assay. Giemsa stained T. cruzi infected MK2 cells showed that the light-treated parasites in plasma and platelets were deficient in infecting MK2 cells and did not differentiate further into intracellular amastigotes unlike the untreated parasites. The light-treated and untreated parasite samples were then evaluated for any residual infectivity by injecting the treated parasites into Swiss Webster mice, which did not develop infection even after the animals were immunosuppressed, further demonstrating that the light treatment was completely effective for inactivation of the parasite; the light-treated platelets had similar in vitro metabolic and biochemical indices to that of untreated platelets. Overall, these results provide a proof of concept toward developing 405 nm light treatment as a pathogen reduction technology (PRT) to enhance the safety of stored human plasma and platelet concentrates from bloodborne T. cruzi, which causes Chagas disease.

405 nm light↗

The Preclinical Validation of 405 nm Light Parasiticidal Efficacy on Leishmania donovani in Ex Vivo Platelets in a Rag2 -/- Mouse Model

Violet–blue light of 405 nm in the visible spectrum at a dose of 270 J/cm 2 alone has been shown to be an effective microbicidal tool for inactivating several bacteria, HIV-1, and Trypanosoma cruzi in ex vivo plasma and platelets. Unlike chemical- and ultraviolet (UV)-based pathogen inactivation methods for plasma and platelet safety, 405 nm light is shown to be less toxic to host cells at light doses that are microbicidal. In this report, we evaluated the parasiticidal activity of a 405 nm light treatment on platelets spiked with the Leishmania donovani parasite. Following the light treatment, parasite viability was observed to be near zero in both low- and high-titer-spiked platelets relative to controls. Furthermore, to test the residual infectivity after inactivation in vivo, the light-treated low-titer L. donovani-spiked platelets were evaluated in an immunodeficient Rag2 -/- mouse model and monitored for 9 weeks. The parasiticidal efficacy of 405 nm light was evident from the lack of a presence of parasites in the mice spleens. Parasiticidal activity was confirmed to be mediated through 405 nm light-induced reactive oxygen species (ROS), as quantitatively measured by a 2',7'-Dichlorodihydrofluorescein diacetate (H 2 DCFDA)-based assay. Overall, these results confirm the complete inactivation of L. donovani spiked in ex vivo platelets by 405 nm light treatment and exemplify the utility of the Rag2 -/- mouse infection model for the preclinical validation of the parasiticidal efficacy of 405 nm light and this light-based technology as a potential PRT for ex vivo platelets.

405 nm light↗