Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse analysis measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Observability of dark matter substructure with pulsar timing correlations

Dark matter substructure on small scales is currently weakly constrained, and its study may shed light on the nature of the dark matter. In this work we observe the gravitational effects of dark matter substructure on measured pulsar phases in pulsar timing arrays (PTAs). Due to the stability of pulse phases observed over several years, dark matter substructure around the Earth-pulsar system can imprint discernible signatures in gravitational Doppler and Shapiro delays. We compute pulsar phase correlations induced by general dark matter substructure, and project constraints for a few models such as monochromatic primordial black holes (PBHs), and Cold Dark Matter (CDM)-like NFW subhalos. This work extends our previous analysis, which focused on static or single transiting events, to a stochastic analysis of multiple transiting events. We find that stochastic correlations, in a PTA similar to the Square Kilometer Array (SKA), are uniquely powerful to constrain subhalos as light as ~ 10 -13 M ⊙ , with concentrations as low as that predicted by standard CDM.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiochemical capabilities for astrophysics experiments at the national ignition facility

The Nuclear and Radiochemistry Group at Lawrence Livermore National Laboratory (LLNL) has developed a suite of diagnostics and techniques that can be used for astrophysics experiments at the National Ignition Facility (NIF). Capabilities have been developed to add material to the outside of NIF hohlraum assemblies as well as to the interior of NIF target capsules or the fill gas. The ability to place very small amounts of material close to the NIF target enables activation with very large, short-pulse neutron fluxes. The Solid Radiochemistry Diagnostic can be used to collect solid debris from a NIF shot within 2 h of the execution of a shot, and this can be analyzed for radioactive signatures with or without post-shot chemical processing. The Radiochemical Analysis of Gaseous Samples diagnostic system can be used to collect gaseous products produced during a NIF shot. Capsule doping and radiochemical analysis capabilities at NIF will be discussed. The application of these techniques to astrophysical measurements will be discussed as well as some preliminary results.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Improved Fireset Acceptance Using Established Evaluation Measurements

As new insight is gained into the relationship between firesets and detonators, tighter control of the circuit parameters is desired to maintain consistent and optimum system performance. An analysis of the established acceptance method reveals that it has insufficient precision to guarantee a uniform population of units. While the production has been historically very uniform, the uniformity has been primarily due to the quality and consistency of the manufacturing process rather than to the stringency of the acceptance criteria. The established method of evaluating and accepting firesets for the stockpile has been to discharge the units into a representative load and to record the output current waveform. Three characteristics of the output waveform (Peak Current, Rise Time, and Pulse Width) are then analyzed and an acceptance window is applied directly to these measurements. The purpose of this paper is to introduce a new approach that incorporates these same established measurements. However, instead of applying acceptance criteria to the three measurements directly, rather these measurements are used to evaluate the circuit values of capacitance, inductance and resistance to provide a more stringent and uniform acceptance criteria.

42 ENGINEERING↗

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

Sub-critical assembly die-away analysis with organic scintillators

Determining the reactivity of systems containing fissile material is essential for verifying safety, and possession and enrichment levels. The goal of this experiment was to characterize a subcritical nuclear fuel assembly irradiated by a pulsed neutron generator through differential die-away analysis. Similar characterizations are commonly performed with thermal neutron detectors, but these detectors are bulky and cumbersome, the materials are not widely available, and timing can be clouded by the required thermalization time. In this work, an organic scintillator capable of detecting both neutrons and photons was used to measure the die-away profiles of both particles. These time profiles were then used to estimate the reactivity of the assembly. Here, the calculated reactivity estimates compare favorably to simulated estimates, and therefore provide a useful tool for fissile material characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Exploring the High-Pressure Phases of Carbon through X-ray Diffraction of Dynamic Compression Experiments on Sandia’s Z Pulsed Power Facility

The carbon phase diagram is rich with polymorphs which possess very different physical and optical properties ideal for different scientific and engineering applications. An understanding of the dynamically driven phase transitions in carbon is particularly important for applications in inertial confinement fusion, as well as planetary and meteorite impact histories. Experiments on the Z Pulsed Power Facility at Sandia National Laboratories generate dynamically compressed high-pressure states of matter with exceptional uniformity, duration, and size that are ideal for investigations of fundamental material properties. X-ray diffraction (XRD) is an important material physics measurement because it enables direct observation of the strain and compression of the crystal lattice, and it enables the detection and identification of phase transitions. Several unique challenges of dynamic compression experiments on Z prevent using XRD systems typically utilized at other dynamic compression facilities, so novel XRD diagnostics have been designed and implemented. We performed experiments on Z to shock compress carbon (pyrolytic graphite) samples to pressures of 150–320 GPa. The Z-Beamlet Laser generated Mn-Heα (6.2 keV) X-rays to probe the shock-compressed carbon sample, and the new XRD diagnostics measured changes in the diffraction pattern as the carbon transformed into its high-pressure phases. Quantitative analysis of the dynamic XRD patterns in combination with continuum velocimetry information constrained the stability fields and melting of high-pressure carbon polymorphs.

36 MATERIALS SCIENCE↗

Controlling beam trajectory and transport in a tapered helical undulator

In this paper we present a detailed discussion of the helical undulator system developed for high extraction efficiency experiments in the tapered-enhanced stimulated superradiant amplification regime. The design is based on permanent magnet technology and comprises two Halbach arrays orthogonally oriented and shifted by 90° with respect to each other. When used in low energy beamlines for THz generation, the electron beam trajectory and transport are particularly sensitive to the undulator off-axis fields so that it becomes important to complement on-axis field measurements with analysis and tuning of the higher-order field components. Here we describe how the pulsed wire measurement technique can be effectively used to retrieve on- and off-axis magnetic field characteristics of the undulator. A simple two-dipole model is developed to guide the final adjustments to the permanent magnet positions along the array to tune the quadrupole and sextupole components of the field.

free-electron lasers↗

Fast permeability measurement for tight reservoir cores using only initial data of the one chamber pressure pulse decay test

Here, in this study, a mathematical model for fast determination of the permeabilities of tight rocks using measurements taken from the initial period of the One Chamber Pressure Pulse Decay (OC-PPD) test is presented. The model applies to measurements taken both before and after the pressure pulse front has reached the downstream end of the specimen. The analytical solutions for the pressure decay in the upstream chamber are derived based on a parabolic arc approximation of pore pressure distribution along the test specimen. This approximation allows converting the initial–boundary value problem of fluid diffusion in the specimen, governed by partial differential equations, to a system of ordinary differential equations that can be easily solved by explicit formulae. Thus, an explicit formula for the pressure decay rate is obtained, which enables inverse analysis of the initial experimental data to estimate the rock permeability. The proposed method expedites the pulse decay test as it does not require the system to reach equilibrium. The method is validated with three sets of experimental data of the OC-PPD test using helium as the diffusing fluid, for which the relative error of the permeability is found to be less than 6%. This method is particularly useful if the equilibrium time of the pulse decay test for rock specimens with permeabilities in the range of nano-Darcy takes hours or days.

early-time solution↗

Development of a Pulsed Slowing-Down-Time Benchmark of Neutron Thermalization in Graphite

Graphite is a classic neutronic material that has been used as both a reactor reflector and moderator in various nuclear reactor systems. The ability to accurately predict the slowing down and thermalization of neutrons in graphite can have significant implications on the safety and operation of such reactor systems. In reactors, the neutron thermalization process is quantified using the thermal scattering law (TSL) and related cross sections for a given moderator. An ideal approach to assess the validity of TSL data is using benchmark measurement based on the pulsed Slowing-Down-Time technique and its comparison with the appropriate graphite nuclear library. In this work, experimental measurement and computational Monte Carlo simulations were performed to benchmark the slowing down characteristics and thermalization of neutrons in nuclear (reactor-grade) graphite. Given the density of graphite, various graphite libraries were selected for the benchmark analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 1—Theory

Summary Core-scale measurements are considered the ground truth that oil and gas or electric utility companies use to predict the migration of fluids such as oil, natural gas, carbon dioxide, or brine deep underground during their extraction or injection operations. To provide a greater understanding of petrophysical properties of low-permeability geologic formations such as shales and tight gas sandstones, this study introduces a novel core-analysis procedure. The technique follows conventional pressure-pulse-decay permeametry, where the pressure in an inlet chamber adjacent to a cylindrical core plug undergoes a rapid pressurization, the system is shut in, and the pressure reaches a new equilibrium. However, unlike a standard unidirectional pressure-pulse decay, the full-immersion pressure-pulse decay (Hannon 2019) applies a pressure disturbance to the entire outer surface area of the sample. This article covers the numerical simulator designed to model flow through an anisotropic porous sample in this scenario. The model assumes distinct but uniform permeabilities along the radial and axial directions of the cylindrical plug sample. When extracting a plug vertically (or perpendicular to bedding), the permeability along the radial direction associates with the horizontal permeability (i.e., parallel to bedding), whereas in the axial direction, flow occurs perpendicular to bedding (a vertical permeability). Investigations of these model outputs demonstrate an approximately 20-fold decrease in time to complete a full-immersion experiment compared with conventional pressure-pulse decay. Furthermore, the pressure-decay curves resulting from the full-immersion method have slightly different shapes than those resulting from other unidimensional transient methods. These differences begin to demonstrate that, under achievable experimental conditions, the analysis of pressure data from one full-immersion test could enable the simultaneous estimation of the apparent permeabilities parallel and perpendicular to bedding of a cylindrical sample in addition to its porosity. A follow-up article finalizes the proof of this capability with a parameter-estimation procedure and presents experimental verification through a proof-of-concept study. Described in greater detail in that article, the parameter estimator requires multiple forward simulations to analyze the data, which behooves minimizing the compute time for each simulation. By using an alternating direction implicit time-marching scheme and a structured but variably spaced grid, the numerical simulator built for this purpose provides a forward model output with suitable accuracy in approximately 0.5 seconds.

Energy & Fuels↗

Near real-time streaming analysis of big fusion data

Experiments on fusion plasmas produce high-dimensional data time series with ever-increasing magnitude and velocity, but turn-around times for analysis of this data have not kept up. For example, many data analysis tasks are often performed in a manual, ad-hoc manner some time after an experiment. In this article, we introduce the Delta framework that facilitates near real-time streaming analysis of big and fast fusion data. By streaming measurement data from fusion experiments to a high-performance compute center, Delta allows computationally expensive data analysis tasks to be performed in between plasma pulses. This article describes the modular and expandable software architecture of Delta and presents performance benchmarks of individual components as well as of an example workflow. Focusing on a streaming analysis workflow where electron cyclotron emission imaging (ECEi) data is measured at KSTAR on the National Energy Research Scientific Computing Center's (NERSC's) supercomputer we routinely observe data transfer rates of about 4 Gigabit per second. In NERSC, a demanding turbulence analysis workflow effectively utilizes multiple nodes and graphical processing units and executes them in under 5 min. We further discuss how Delta uses modern database systems and container orchestration services to provide web-based real-time data visualization. For the case of ECEi data we demonstrate how data visualizations can be augmented with outputs from machine learning models. Here, by providing session leaders and physics operators, results of higher-order data analysis using live visualizations may make more informed decisions on how to configure the machine for the next shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of Nuclear Data Measurement and Analysis at RPI [Slides]

This presentation discusses the experimental, simulation, and nuclear data methods that were validated for the RPI γ-Multiplicity Detector. When the neutron capture γ-cascade data is well-known, the γ-emission spectra can be accurately calculated using the modified simulation tools. The RPI γ-Multiplicity Detector system is now ready for analysis and recommendations for isotopes with deficiencies in γ-ray data. The presentation also discusses future work which includes developing a method for analyzing and adjusting nuclear data for 59 Co, 55 Mn and other measured isotopes including 181 Ta. Additionally, future work includes comparing experimental γ-emission spectra with MCNP-6.2/DICEBOX simulations for 238 U and 235 U. In summation, new capture and transmission measurements for 54 Fe will help improve resonance parameter evaluation. Neutron capture gamma cascade spectra and yields were measured in the resolved resonance region and compared to evaluations. In addition, the pulsed neutron die-away method was developed as a tool to provide data for validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Forward and backward stimulated Raman scattering in multi-speckled beams: Density dependence and effects on cross-beam energy transfer

Particle-in-cell simulations of cross-beam energy transfer (CBET) between multi-speckled beams reveal a potentially prominent energy loss from forward stimulated Raman scattering (FSRS) in the amplified seed beam [Yin et al., Phys. Plasmas 26, 082708 (2019)]. In this work, an intensity scan is used to examine this energy loss in the CBET-amplified seed beam at intensities of a few times 1014 W/cm2. Electron tracers demonstrate both the trapping in the electron plasma waves that is sustained over multiple speckles and the subsequent acceleration to velocities well beyond the phase velocity. Motivated by expanding our understanding of this energy loss mechanism, we isolate the FSRS density dependence by using a 2×1014 W/cm2 pulse to scan densities between 0.06 ncr and 0.12 ncr; a spectral analysis characterizes the energy losses from scattering with the changing densities. At saturation, both greater beam attenuation is measured at the laser frequency and larger scattering FSRS angles are observed as density increases, along with a rapid transition to primarily backscatter SRS between 0.10 ncr and 0.12 ncr, earlier than predicted by linear theory. Density gradients are shown to effectively mitigate oblique FSRS and beam energy losses in the two lower density cases, whereas 0° forward scattering is primarily suppressed in the higher density cases. Finally returning to the two-beam CBET system of interest, the interplay and mitigation of the secondary instabilities at larger domain and beam spatial scales are discussed, here also examining backward stimulated Brillouin scattering.

Stark, D. J. (ORCID:0000000203642733)↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revisiting the Detection of Optical Lightning Superbolts

This study uses Fast On-Orbit Detection of Transient Events (FORTE) satellite observations to identify superbolt-class optical lightning events and evaluate their origins. Superbolts have been defined by Turman as lightning pulses whose peak optical power exceeds 1011 W. However, it has been unclear whether superbolts resulted from particular types of high-energy lightning process or whether they were the result of measurement bias. In the latter case, any decently bright lightning process could be recorded as a superbolt if the sensor had a particularly clear sight line to the hot channel without thick clouds diluting the optical signals. Here, our 12-year analysis of FORTE superbolt detections indicates that the lower optical superbolt energy range (~100 GW) is dominated by normal lightning, but brighter cases are predominantly strong +CG strokes that originate from specific types of storms. Oceanic storm systems, particularly during the winter, and especially those located around Japan are shown to produce these intense superbolts. We suggest that some optical superbolts result from favorable viewing conditions and would not be identified as such by another instrument located elsewhere and that others are associated with a unique set of physics that may merit the “superbolt” distinction.

54 ENVIRONMENTAL SCIENCES↗

Monitoring Radiochemical Processing Streams for the 238 Pu Supply Program with Process Pulse II

Oak Ridge National Laboratory (ORNL) is developing advanced spectroscopic and real-time monitoring capabilities to improve the timeliness of analytical measurements and process decisions for the 238Pu Supply Program. Reducing the time, resources, and costs associated with each production campaign is critical because overlapping campaigns will be required to meet the production goals of the National Aeronautics and Space Administration. Real-time, in situ analytical measurements in the heavily shielded hot cells at the Radiochemical Engineering Development Center (REDC) will allow for rapid process information feedback and operational benefits that help the 238Pu supply program scale-up production efforts. Noteworthy steps were taken during Campaign 5 to establish the ability to monitor processing streams in real time with spectrophotometry and a commercially available online monitoring software called The Unscrambler X Process Pulse II (PP) multivariate statistical process monitoring system by Camo Analytics (version 5.60). PP automates univariate-type calculations within the software itself and executes multivariate models built using The Unscrambler X (version 10.4 or newer). The Unscrambler is a commercially available data analysis software made by the same company. PP is composed of easy-to-use-tools for all personnel, including data scientists and technicians. The software can be used to plot analyte concentration profiles, spectral data, and other process variables in real time. All process data are represented in a single view with interactive charts useful for viewing how a process evolves over time.

07 ISOTOPE AND RADIATION SOURCES↗