Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse burst laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Time-resolved CO 2 , CO, and N 2 vibrational population measurements in Ns pulse discharge plasmas

Abstract Time-resolved CO 2 and N 2 vibrational populations and translational-rotational temperature are measured in a CO 2 –N 2 plasma sustained by a ns pulse discharge burst in plane-to-plane geometry. Time-resolved, absolute number density of CO generated in the plasma is also inferred from the experimental data. CO 2 and CO vibrational populations are measured by mid-IR, tunable quantum cascade laser absorption spectroscopy, and N 2 vibrational populations are measured by the ns broadband vibrational CARS. Transient excitation of N 2 and CO 2 asymmetric stretch vibrational energy modes is detected during the discharge burst. The time-resolved rate of CO generation does not correlate with N 2 or CO 2 ( ν 3 ) vibrational temperatures, indicating that CO 2 dissociation via the vibrational excitation is insignificant at the present conditions. The rate of CO generation decreases gradually during the discharge burst. The estimated specific energy cost of the CO product is close to that of N atoms in pure nitrogen, measured previously at similar operating conditions. Comparison of the experimental data with the kinetic modeling analysis indicates that CO 2 dissociation in collisions with electronically excited N 2 molecules is the dominant channel of CO generation at the present conditions, although the inferred CO yield in these processes is significantly lower than 1. The effect of vibrational energy transfer between N 2 and CO 2 on the plasma chemical processes is insignificant. The kinetic model underpredicts a rapid reduction of the N 2 and CO 2 ( ν 3 ) vibrational temperatures during the later half of the discharge burst and in the afterglow. V–T relaxation of N 2 by N and O atoms generated in the ns pulse discharge plasma does not affect the vibrational relaxation rate in a significant way. However, rapid V–T relaxation of CO 2 by O atoms has a significant effect on the relaxation rate. The difference between the experimental data and the modeling predictions may be due to the unknown scaling of the CO 2 –O V–T rates with the vibrational quantum number.

Physics↗

Metastable argon dynamics in a pulsed microplasma at 43 GHz

Short pulses of millimeter wave (MMW) radiation at 43 GHz create microplasma within a photonic crystal for pressures from 40 to 600 Torr (1.3 × 10 3 –8.0 × 10 4 Pa). Gas breakdown occurs within a photonic crystal, which acts as an electromagnetic resonator to create a strong initial electric field. The time response of the argon metastable density is experimentally determined during the pulse and in the afterglow using laser absorption. The metastable density overshoots the steady-state condition at the beginning of the pulse and during the afterglow. Modeling is presented to understand these observations. The overproduction of argon 1s5 at the beginning of each pulse is due to a concurrent overshoot in the MMW electric field within the photonic crystal. This field overheats the plasma electrons and enhances the production of excited states. The burst of argon metastables observed in the afterglow is due to the pooled energy of the plasma stored in electrons, ions, and excited states of argon. As a result, understanding metastable production is an important intermediate step to ionization and is also critical in the study of diode-pumped rare gas lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Effect of Penetration Depth on Thermal Contrast of NDT by Thermography

Nondestructive evaluation by Thermography (TNDE) is generally classified into two categories, the passive approach and the active approach. The passive approach is usually performed by measuring the natural temperature difference between the ambient and the material or structure to be tested. The active approach, on the other hand, requires the application of an external energy source to stimulate the material for inspection. A laser, a heater, a hot air blower, a high power thermal pulse, mechanical, or electromagnetic energy may provide the energy sources. For the external heating method to inspect materials for defects and imperfection at ambient temperature, a very short burst of heat can be introduced to one of the surfaces or slow heating of the side opposite to the side being observed. Due to the interruption of the heat flow through the defects, the thermal images will reveal the defective area by contrasting against the surrounding good materials. This technique is called transient Thermography, pulse video Thermography, or thermal wave imaging. As an empirical rule, the radius of the smallest defect should be at least one to two times larger than its depth under the surface. Thermography is being used to inspect void, debond, impact damage, and porosity in composite materials. It has been shown that most of the defects and imperfection can be detected. However, the current method of inspection using thermographic technique is more of an art than a practical scientific and engineering approach. The success rate of determining the defect location and defect type is largely depend on the experience of the person who operates thermography system and performs the inspection. The operator has to try different type of heat source, different duration of its application time, as well as experimenting with the thermal image acquisition time and interval during the inspection process. Further-more, the complexity of the lay-up and structure of composites makes it more difficult to determine the optimal operating condition for revealing the defects. In order to develop an optimal thermography inspection procedure, we must understand the thermal behavior inside the material subjected to transient heat in order to interpret the thermal images correctly. Fabrication of finite element models of characteristic defects in composite materials subjected to transient heat will enable the development of appropriate procedure for thermography inspection. Design of phantom defects could be modeled and behavior characterized prior to physically building these test parts. Since production of phantom test parts can be very time consuming and laborious, it is important to design good representative defects.

Chu, Tsuchin Philip↗

2D-imaging of absolute OH and H 2 O 2 profiles in a He–H 2 O nanosecond pulsed dielectric barrier discharge by photo-fragmentation laser-induced fluorescence

We report pulsed dielectric barrier discharges (DBD) in He–H 2 O and He–H 2 O–O 2 mixtures are studied in near atmospheric conditions using temporally and spatially resolved quantitative 2D imaging of the hydroxyl radical (OH) and hydrogen peroxide (H 2 O 2 ). The primary goal was to detect and quantify the production of these strongly oxidative species in water-laden helium discharges in a DBD jet configuration, which is of interest for biomedical applications such as disinfection of surfaces and treatment of biological samples. Hydroxyl profiles are obtained by laser-induced fluorescence (LIF) measurements using 282 nm laser excitation. Hydrogen peroxide profiles are measured by photo-fragmentation LIF (PF-LIF), which involves photo-dissociating H 2 O 2 into OH with a 212.8 nm laser sheet and detecting the OH fragments by LIF. The H 2 O 2 profiles are calibrated by measuring PF-LIF profiles in a reference mixture of He seeded with a known amount of H 2 O 2 . OH profiles are calibrated by measuring OH-radical decay times and comparing these with predictions from a chemical kinetics model. Two different burst discharge modes with five and ten pulses per burst are studied, both with a burst repetition rate of 50 Hz. In both cases, dynamics of OH and H 2 O 2 distributions in the afterglow of the discharge are investigated. Gas temperatures determined from the OH-LIF spectra indicate that gas heating due to the plasma is insignificant. The addition of 5% O 2 in the He admixture decreases the OH densities and increases the H 2 O 2 densities. The increased coupled energy in the ten-pulse discharge increases OH and H 2 O 2 mole fractions, except for the H 2 O 2 in the He–H 2 O–O 2 mixture which is relatively insensitive to the additional pulses.

hydrogen peroxide↗

Measurements and kinetic modeling of O 2 vibrational kinetics in O 2 –Ar mixtures partially dissociated by a Ns pulse discharge

Vibrational kinetics of O 2 is studied during the O atom recombination in an O 2 –Ar mixture, partially dissociated by a burst of ns discharge pulses in a heated plasma flow reactor. The time-resolved temperature in the discharge afterglow is determined by Rayleigh scattering. Time-resolved O atom number density is measured by ps Two-Photon absorption Laser Induced Fluorescence, calibrated in xenon. Time-resolved vibrational level populations of molecular oxygen, O 2 (v= 8–20), are measured by ps Laser Induced Fluorescence (LIF), with the absolute calibration by NO LIF. Time-resolved ozone number density is monitored by broadband UV absorption. The results are compared with the predictions of a state-specific kinetic model. The experimental data indicate a rapid initial decay of O 2 (v) populations generated by electron impact in the discharge, due to the vibration-translation (V–T) relaxation by O atoms. This is followed by a slower population reduction, on the time scale much longer compared to that for V–T relaxation or vibration-vibration (V–V) exchange. Both O atoms and the O 2 (v) populations decay on the same time scale, indicating that chemical reactions initiated by the O atom recombination result in the generation of vibrationally excited O 2 molecules. These trends are reproduced by the kinetic model, which shows that the reaction of O atoms with ozone is the dominant pathway of O 2 (v) generation at the present conditions. The predicted relative O 2 (v) populations are close to the experimental results, but absolute number densities differ from the experimental data. This is likely due to uncertainties in the absolute calibration of LIF measurements and in the spectroscopic model used in the data reduction. The present work demonstrates the capability for the absolute, time-resolved measurements of vibrationally excited O 2 in recombining gas flows, to quantify the energy partition in the recombination reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray emission from high temperature plasmas

The physical processes occurring in plasma focus devices were studied. These devices produce dense high temperature plasmas, which emit X rays of hundreds of KeV energy and one to ten billion neutrons per pulse. The processes in the devices seem related to solar flare phenomena, and would also be of interest for controlled thermonuclear fusion applications. The high intensity, short duration bursts of X rays and neutrons could also possibly be used for pumping nuclear lasers.

Harries, W. L.↗

Megahertz Rate Optical Diagnostics of Explosively Generated Soot

Detonation of a solid explosive produces a turbulent and luminous post‐detonation fireball containing condensed carbon soot. Diagnostics of soot dynamics are needed for model validation and to interpret emission signals. Diffuse back‐illumination extinction imaging (DBI‐EI) and laser‐induced incandescence (LII) are two common optical diagnostics for flame soot. This work extends both to measure time‐resolved soot dynamics from a 12 mm HMX hemisphere. DBI‐EI measured line‐of‐sight optical extinction exceeds 99% in some regions. Results are tomographically inverted to obtain a signal proportional to the soot volume fraction. Pulse‐burst LII measures are presented at 1 MHz. For the first time, LII results are combined with DBI‐EI extinction measurements to quantify and correct for signal trapping. Following this, spatially and temporally resolved DBI‐EI and LII measures are shown to be in reasonable agreement. Finally, experimental results are compared against recently developed simulations. Quantitative differences in the soot mixing dynamics are resolved. These findings motivate future model improvements and demonstrate ongoing needs for diagnostic advancements for heavily sooting environments.

diffuse back-illumination extinction imaging↗

A combined MeV-neutron and x-ray source for the National Ignition Facility

We report that in support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF’s long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal > 1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×10 13 n/cm 2 and an x-ray dose of 7 krad.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlled molecule injector for cold, dense, and pure molecular beams at the European x-ray free-electron laser

A permanently available molecular-beam injection setup for controlled molecules (COMO) was installed and commissioned at the small quantum systems (SQS) instrument at the European x-ray free-electron laser (EuXFEL). A b-type electrostatic deflector allows for pure state-, size-, and isomer-selected samples of polar molecules and clusters. The source provides a rotationally cold (T ≈ 1 K) and dense (ρ ≈ 10 8 cm −3 ) molecular beam with pulse durations up to 100 µs generated by a new version of the Even-Lavie valve. Here, a performance overview of the COMO setup is presented along with characterization experiments performed both with an optical laser at the Center for Free-Electron-Laser Science and with x rays at EuXFEL under burst-mode operation. COMO was designed to be attached to different instruments at the EuXFEL, in particular, the SQS and single particles, clusters, and biomolecules (SPB) instruments. This advanced controlled-molecules injection setup enables x-ray free-electron laser studies using highly defined samples with soft and hard x-ray FEL radiation for applications ranging from atomic, molecular, and cluster physics to elementary processes in chemistry and biology.

He, Lanhai↗

1 GW peak power and 100 J pulsed operation of a diode-pumped Tm:YLF laser

We report on the generation of high energy, high power pulses in a tabletop diode-pumped Tm:YLF-based laser system, which delivers amplified pulse energies up to 108 J, as well as GW peak power performance when seeded with nanosecond duration pulses. Furthermore, the high power and efficiency capabilities of operating Tm:YLF in the multi-pulse extraction (MPE) regime were explored by seeding the experimental setup with a multi-kHz burst of pulses exhibiting a low individual pulse fluence, resulting in a 3.6 kW average power train of multi-joule-level pulses with an optical-to-optical efficiency of 19%.

47 OTHER INSTRUMENTATION↗

Versatile LDV burst simulator

A device for generating burst signals is reported that can be used to determine whether or not a laser Doppler velocimeter is operating properly. A high frequency signal which corresponds to the information frequency of the laser Doppler velocimeter is modulated by a low frequency signal to provide an envelope for the high frequency signal. The high frequency signal is modulated by any modulator means such as, for example, an analog multiplier. The low frequency signal is added to the modulated signal to provide pedestals for the resulting series of burst pulses. The means are provided for selecting different combinations of these burst signals. Also means are provided for making the burst signals asymmetrical as desired. In addition, means are provided for varying the frequencies, and amplitudes of the information, envelope and pedestal frequency signals in the burst signals.

Youngbluth, O., Jr.↗

Shaping attosecond pulses by controlling the minima in high-order harmonic generation through alignment of CO 2 molecules

In this paper, we report a simple method for generating shaped attosecond pulses by using a CO 2 molecule. Unlike most other molecules, owing to its unique energy and angle dependence and the presence of deep minima in the photoionization transition dipole moment, the shape of harmonic spectra, especially the position and depth of minima, can be readily controlled by tuning the degree of alignment. The sensitive alignment dependence of the minima is due to the coherent interference of a laser-induced dipole from each molecule when CO 2 molecules are moderately aligned, but not when they are well aligned or when they are isotropically distributed. Such a sensitivity offers a simple way of controlling the spectral amplitude and phase of the generated harmonics and thus shaping the generated attosecond pulses, for example, producing structured attosecond pulses by splitting a single burst into two. We illustrate how such pulses are generated and how to characterize them. This method offers a simple way to shape attosecond pulses at the generation step. It can be easily implemented experimentally to generate attosecond pulses with strong phase variations for unique applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-Temperature, High-Pressure Optical Cells

Optical cell constructed for measurement of thermal diffusivity of HgCdTe semiconductor by laser pulses. Container allows radiation from laser to enter one side of alloy sample, while allowing lower-energy infrared radiation to leave opposite side of sample so temperature rise read by sensor. Composed entirely of fused silica, cell includes two optical windows joined by tube. Cell withstands 1,000 degrees C cell-operating temperature and contains molten alloy at its 100-atmosphere vapor pressure. Finally, allows alloy to solidify without bursting even though alloy expands on cooling.

Harris, R. P.↗

Progress in coherent laser radar

Considerable progress with coherent laser radar has been made over the last few years, most notably perhaps in the available range of high performance devices and components and the confidence with which systems may now be taken into the field for prolonged periods of operation. Some of this increasing maturity was evident at the 3rd Topical Meeting on Coherent Laser Radar: Technology and Applications. Topics included in discussions were: mesoscale wind fields, nocturnal valley drainage and clear air down bursts; airborne Doppler lidar studies and comparison of ground and airborne wind measurement; wind measurement over the sea for comparison with satellite borne microwave sensors; transport of wake vortices at airfield; coherent DIAL methods; a newly assembled Nd-YAG coherent lidar system; backscatter profiles in the atmosphere and wavelength dependence over the 9 to 11 micrometer region; beam propagation; rock and soil classification with an airborne 4-laser system; technology of a global wind profiling system; target calibration; ranging and imaging with coherent pulsed and CW system; signal fluctuations and speckle. Some of these activities are briefly reviewed.

Vaughan, J. M.↗

A versatile burst generator for LDV

A laser-Doppler velocimeter (LDV) burst generator developed for calibration of an LDV before an actual test is described. This generator uses voltage-controlled oscillators to produce the information frequency up to 1 MHz and the pedestal frequency up to 10 MHz. The amplitude and the frequency of each signal can be adjusted independently, and the generator is capable of producing a single burst or a variety of periodic and aperiodic bursts. Variable symmetry in the burst signal can be introduced to the point of producing the 'double-pulse' burst. An LED display is used for the readout of the information and the pedestal frequencies.

Youngbluth, O., Jr.↗

Visualization of Freestream Vortices in the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel

Streamwise vortices present in the freestream of the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel have been observed experimentally for the first time. A high-energy, burst-mode laser system was used to conduct time-resolved planar laser Mie scattering in the freestream of this facility. The freestream of the facility was observed over Mach numbers ranging from 2.4 to 4.6 and (unit) Reynolds number between 3.3 × 10 6 to 14.8 × 10 6 1/m. Apparent vortical structures were observed in the tunnel freestream at Mach numbers ≤ 3 with little difference observed for varying Reynolds number. With further-increasing Mach number, protrusive and oscillatory vertical ‘sprite’ structures were observed emanating from the tunnel floor boundary layer. Neither of these structural phenomena have been observed before experimentally in the facility and act to confirm and inform predictions made in computational fluid dynamic simulations of the facility.

Flow visualization↗

Visualization of Freestream Vortices in the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel

Streamwise vortices present in the freestream of the NASA Langley 4-Foot Supersonic Unitary Plan Wind Tunnel have been observed experimentally for the first time. A high-energy, burst-mode laser system was used to conduct time-resolved planar laser Mie scattering in the freestream of this facility. The freestream of the facility was observed over Mach numbers ranging from 2.4 to 4.6 and (unit) Reynolds number between 3.3 × 10 6 to 14.8 × 10 6 1/m. Apparent vortical structures were observed in the tunnel freestream at Mach numbers ≤ 3 with little difference observed for varying Reynolds number. With further-increasing Mach number, protrusive and oscillatory vertical ‘sprite’ structures were observed emanating from the tunnel floor boundary layer. Neither of these structural phenomena have been observed before experimentally in the facility and act to confirm and inform predictions made in computational fluid dynamic simulations of the facility.

Flow visualization↗

Early experience with a highly mobile Lageos ranging system

Two portions of the University of Texas Transportable Laser Ranging System (TLRS) are presented: the beam director and the burst mode single photon laser ranging system. The system, optimized for the Lageos target, has satellite track rates varying from approximately 1800 arcsec per sec on low targets to a few arcsec per sec on the highest. Using full aperture, approximately 3 millijoules of laser power per shot can be transmitted without exceeding the eye damage threshold, and a beam divergence of less than 30 arcsec is dictated by these parameters. Position loop response is optimized, and the instrument is capable of tracking the satellite from nearly any firm, flat position. The laser ranging system uses a multiple pulse laser, and power restrictions result in an average return of less than one photoelectron per shot. The use of a simple laser for ranging has virtually eliminated the high percentage of down time.

Silverberg, E. C.↗