Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

All-optical single-shot complete electric field measurement of extreme ultraviolet free electron laser pulses

Recent advances in ultrafast extreme ultraviolet (EUV) and x-ray light sources provide direct access to fundamental time and length scales for biology, chemistry, and materials physics. However, such light pulses are challenging to measure due to the need for femtosecond time resolution at difficult-to-detect wavelengths. Also, single-shot measurements are needed because severe pulse-to-pulse fluctuations are common. Here we demonstrate single-shot, complete field measurements by applying a novel version of frequency resolved optical gating. An EUV free electron laser beam creates a transient grating containing the pulse’s electric field information, which is read out with a 400 nm probe pulse. By varying the time delay between two copies of the EUV pump, rather than between the pump and the probe, we separate the needed coherent wave mixing from the slow incoherent response. Because this approach uses photoionization, it should be applicable from the vacuum ultraviolet to hard x rays.

36 MATERIALS SCIENCE↗

A Square Pulse Thermoreflectance Technique for the Measurement of Thermal Properties

We report on a laser-based square pulse thermoreflectance (SPTR) technique for the measurement of thermal properties for a wide range of materials. SPTR adopts the pump-probe thermoreflectance principle to monitor the evolution of local temperature after square pulse excitation. The technique features a compact setup, high spatial resolution, and fast data collection. By comparing the acquired SPTR signals with a continuum heat transfer model, material thermal properties can be obtained. Taking advantage of various spot sizes and modulation frequencies, SPTR can measure both the thermal diffusivity and thermal conductivity of poorly to moderately conductive materials and the thermal conductivity of conductive materials with satisfactory accuracy, with potential to be applied to more conductive materials. The technique was validated on three materials: fused silica, single crystal CaF2 and single crystal nickel (with conductivities ranging from 1 W·m -1 ·K -1 to 100 W·m -1 ·K -1 ) with typical measurement errors of 5 % to 20 %. The leading sources of error have been identified by Monte Carlo simulations, and the primary limitations of SPTR are discussed. The compact, fiberized platform we describe here will allow instruments based on this methodology to be deployed in complex, multi-analytical environments for the type of high-throughput correlative analyses that are key to materials design and discovery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot measurements of shaped XUV FEL pulses with frequency-resolved optical gating

The ability to control the amplitude and phase of extreme ultraviolet (XUV) and X-ray free-electron laser (FEL) pulses can allow for the extension of optical techniques, such as multidimensional spectroscopy or coherent control, to higher photon energies, for probing and controlling core electronic transitions. However, this requires the ability to make single-shot, and complete, electric field measurements of potentially complex FEL pulses, in order to develop, and verify, pulse shaping strategies. Here, we present direct, single-shot measurements of XUV pulses generated under special operating configurations for producing specific pulse shapes from a laser-seeded XUV FEL. To do this, we built upon our past work using transient grating (TG) cross correlation frequency-resolved optical gating (FROG), where an optical reference pulse is diffracted from an XUV TG produced by a pair of interfering FEL pulses. The resulting nonlinear signal versus frequency and delay, i.e., the FROG trace, contains the electric field of the FEL pulse. The FEL pulse electric field is reconstructed from the FROG trace using a phase retrieval algorithm. Here we confirmed three different pulse shaping strategies for generating chirped, double and multiple FEL pulses by tuning the seed laser and FEL parameters and measuring the resulting shaped FEL pulses with TG XFROG. This work paves the way for generating on-demand pulse shapes with a seeded FEL by improving the characterization of FEL pulses, for transform-limited to more complex shapes.

Elverson, Francesca↗

Thermal detector for measuring radiation parameters of pulsed lasers and generators of submillimetre and millimetre ranges

A theoretical formula is derived that makes it possible to establish a relationship between the speed and sensitivity of bolometers with geometric and thermophysical parameters of the receiving element and substrate. The result is confirmed by a preliminary (evaluation) experiment. The proposed thermal detectors can record and measure the radiation power of lasers and generators of the submillimetre (SMM) and millimetre (MM) ranges. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast UV AlGaN Metal–Semiconductor–Metal Photodetector With a Response Time Below 25 ps

Here, aluminum-gallium-nitride photodetectors were successfully fabricated with micrometer-scale metal–semiconductor–metal structures and tested with ultrafast, UV laser pulses. The measurements were performed with single-shot oscilloscopes. Pulse-broadening effects caused by the measurement system were systematically evaluated and reduced to resolve the intrinsic response time of the detector. The best-performing devices showed a response time of below 25 ps and dark currents below 20 pA. The devices showed linear response with the bias voltage and the laser energy

42 ENGINEERING↗

Simultaneous contrast improvement and temporal compression using divided-pulse nonlinear compression

We experimentally demonstrate how divided-pulse nonlinear compression can be used to improve the temporal contrast of a laser pulse train while simultaneously temporally compressing the pulses. We measure a contrast improvement of almost four orders of magnitude on a nanosecond time scale and temporally compress the pulses from 1.2 ps to 187 fs. The efficiency of our method is also competitive with other contrast improvement methods, with 72% efficiency measured for the main pulse. We expect the method will be useful in the continuing development of high-power, Yb regenerative amplifiers, which suffer from both significant prepulses and relatively long pulse durations.

47 OTHER INSTRUMENTATION↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

CPC data from TAMU TRACER campaign in the Houston, TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.3 LPM is directed to the CPC. To correct the data for particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate total particle loss through the inlet for every SMPS scan at a single deployment location. Second, the CPC data was corrected for particle losses using the average of the total losses per scan. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. An additional flatline correction of 14% was applied to all CPC data based on laboratory calibration prior to and after the campaign. In laboratory calibrations, we identified that for the same sample of air the field CPC (GRIMM Model 5.403 CPC) undercounted the total concentration of particles by 14% compared to the ground truth laboratory CPC (TSI Model 3750). This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

SMPS data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow, 1.0 LPM, is directed through TSI's 0.071 cm impactor attached to the classifier of the SMPS setup. The SMPS’s DMA and CPC are connected through a 20.3 cm length of 0.48 cm diameter tubing. Measured SMPS size distributions were used to calculate size-dependent particle losses for each SMPS scan. Particle losses from diffusion (based on Kesten, 1991 and Gormley, 1949) and inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977) were included in the loss calculation. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977.

54 ENVIRONMENTAL SCIENCES↗

Mini-Micropulse Lidar data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (mini-MPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. The mini-MPL deployed with ROAM-V is a 532 nm elastic and polarization lidar. The mini-MPL outputs normalized relative backscatter (NRB) derived from raw signal after after-pulse, overlap, and dead-time correction calibration. The depolarization ratio is calculated from the co-polarized and cross-polarized NRB (Flynna et al., 2007). The NRB and depolarization ratio data are resampled from the original data at 1-minute intervals. The vertical resolution of the mini-MPL data is 15 meters. The mini-MPL data can be used to determine the boundary layer, cloud top, and cloud bottom height and can be used to retrieve aerosol type and concentration profile. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu . Flynna, C. J., Mendozaa, A., Zhengb, Y., & Mathurb, S. (2007). Novel polarization-sensitive micropulse lidar measurement technique. Optics express, 15(6), 2785-2790.

54 ENVIRONMENTAL SCIENCES↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

Control of electron recollision and molecular nonsequential double ionization

Abstract Intense laser pulses lasting a few optical cycles, are able to ionize molecules via different mechanisms. One such mechanism involves a process whereby within one optical period an electron tunnels away from the molecule, and is then accelerated and driven back as the laser field reverses its direction, colliding with the parent molecule and causing correlated non-sequential double ionization (NSDI). Here we report control over NSDI via spectral-phase pulse shaping of femtosecond laser pulses. The measurements are carried out on ethane molecules using shaped pulses. We find that the shaped pulses can enhance or suppress the yield of dications resulting from electron recollision by factors of 3 to 6. This type of shaped pulses is likely to impact all phenomena stemming from electron recollision processes induced by strong laser fields such as above threshold ionization, high harmonic generation, attosecond pulse generation, and laser-induced electron diffraction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Double echo symmetry-based REDOR and RESPDOR pulse sequences for proton detected measurements of heteronuclear dipolar coupling constants

1 H{X} symmetry-based rotational echo double resonance pulse sequences (S-REDOR) and symmetry-based rotational echo saturation pulse double resonance (S-RESPDOR) solid-state NMR experiments have found widespread application for 1 H detected measurements of difference NMR spectra, dipolar coupling constants, and internuclear distances under conditions of fast magic angle spinning (MAS). In these experiments the supercycled $\text{R4}^2_1 (\text{SR4}^2_1)$ symmetry-based recoupling pulse sequence is typically applied to the 1 H spins to reintroduce heteronuclear dipolar couplings. However, the timing of $\text{SR4}^2_1$ and other symmetry-based pulse sequences must be precisely synchronized with the rotation of the sample, otherwise, the evolution of 1 H CSA and other interactions will not be properly refocused. For this reason, significant distortions are often observed in experimental dipolar dephasing difference curves obtained with S-REDOR or S-RESPDOR pulse sequences. Here we introduce a family of double echo (DE) S-REDOR/S-RESPDOR pulse sequences that function in an analogous manner to the recently introduced $t_1$-noise eliminated (TONE) family of dipolar heteronuclear multiple quantum coherence (D-HMQC) pulse sequences. Through numerical simulations and experiments the DE S-REDOR/S-RESPDOR sequences are shown to provide dephasing difference curves similar to those obtained with S-REDOR/S-RESPDOR. However, the DE sequences are more robust to the deviations of the MAS frequency from the ideal value that occurs during typical solid-state NMR experiments. In this work, the DE sequences are shown to provide more reliable 1 H detected dipolar dephasing difference curves for nuclei such as 15 N (with isotopic labelling), 183 W and 35 Cl. The double echo sequences are therefore recommended to be used in place of conventional S-REDOR/S-RESPDOR sequences for measurement of weak dipolar coupling constants and long-range distances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗