Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse shape”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Attosecond pulse shaping using a seeded free-electron laser

Attosecond pulses are central to the investigation of valence- and core-electron dynamics on their natural timescales. The reproducible generation and characterization of attosecond waveforms has been demonstrated so far only through the process of high-order harmonic generation. Several methods for shaping attosecond waveforms have been proposed, including the use of metallic filters, multilayer mirrors and manipulation of the driving field. However, none of these approaches allows the flexible manipulation of the temporal characteristics of the attosecond waveforms, and they suffer from the low conversion efficiency of the high-order harmonic generation process. Free-electron lasers, by contrast, deliver femtosecond, extreme-ultraviolet and X-ray pulses with energies ranging from tens of microjoules to a few millijoules. Recent experiments have shown that they can generate subfemtosecond spikes, but with temporal characteristics that change shot-to-shot. In this paper we report reproducible generation of high-energy (microjoule level) attosecond waveforms using a seeded free-electron laser. We demonstrate amplitude and phase manipulation of the harmonic components of an attosecond pulse train in combination with an approach for its temporal reconstruction. The results presented here open the way to performing attosecond time-resolved experiments with free-electron lasers.

47 OTHER INSTRUMENTATION↗

Surface plasmon polariton pulse shaping via two-dimensional Bragg grating pairs

Abstract We demonstrate control over the spatial and temporal properties of surface plasmon polaritons (SPPs) launched from nanohole arrays in silver. The arrays provide wave vector matching to allow the conversion of free-space photons into counter-propagating SPPs. SPPs launched from multiple arrays interfere at well-defined spatial positions, and the interference fringes form an all-SPP periodic nano-optical grating which evolves in space and time as the SPPs propagate. The spatio-temporal characteristics of the optical grating can be tuned through various nanohole array parameters such as tilt angle, separation, and array width. In addition, we examine multiperiodic arrays (MPAs) consisting of arrays with different pitches placed adjacent to one another. This platform allows the temporal interference of SPPs with different central wavelengths to be tailored through the MPA geometric and structural parameters. The temporal interference serves as an encoded signal, whereby the frequency components can be controlled by the array properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse shape discrimination in CUPID-Mo using principal component analysis

CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to perform active suppression of $\alpha$ backgrounds, drastically reducing the expected background in the $0\nu\beta\beta$ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.

47 OTHER INSTRUMENTATION↗

Three phase spectral interferometry for recording high dynamic range optical waveforms with <1 ps resolution over >2 ns records applied to closed-loop pulse shaping

Herein we demonstrate, to our knowledge, a novel spectral interferometry technique that simultaneously captures three spectral interferograms of a signal waveform with a reference pulse. The measured performance is robust to nonidealities and ambient drifts by implementing a precisely calibrated 3 × 3 polarization maintaining (PM) splitter that provides three phase shift differences nominally spaced 120° apart. The system can achieve long record length by implementing three, high resolution, virtually imaged phase array (VIPA) spectrometers. Here, we experimentally implement this technique and demonstrate the measurement of waveforms with >2ns of record while maintaining <1ps resolution.

42 ENGINEERING↗

Effects of drive pulse shape on graded metal pushered single shell capsule implosions on the National Ignition Facility

Graded metal pushered single shells (PSS) are a viable alternative to low-Z capsules (Z is the atomic number) for indirect drive inertial confinement fusion implosions due to enhanced core tamping and radiation trapping, but they can be compromised by the pusher mixing with the fuel. We compare 2-shock and 3-shock laser pulses for Be/Cr PSS capsules filled with deuterium–tritium gas fuel at 6 mg/cc density. 1D radiation-hydrodynamic simulations predict higher core compression and, hence, ∼2× higher fusion yield for the 3-shock drive than for 2-shock. Nevertheless, we observe similar core ion temperatures and fusion yields for both drives. The implosion burn duration is 25% shorter and the core volume is ∼2.5× smaller for the 3-shock drive than for 2-shock, consistent with a higher compression. 1D LASNEX mix simulations using a buoyancy-drag model matching the measured yields also agree with the observed core sizes and burn durations and suggest ∼40% and ∼70% yield degradations for 2-shock and 3-shock drives due to hydrodynamic instabilities and atomic mix at the pusher–fuel interface. At the same time, 2D HYDRA simulations show that mid-mode (2–250) instability degradations are negligible for the 2-shock implosion (9%) and significant (45%) for 3-shock. Subtracting these from the 1D mix simulations, we infer similar degradations from high-mode instabilities and atomic mix for both drives. Due to its robustness to mid-mode instabilities, future pusher–gas mix studies will use the 2-shock drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Light output quenching in response to deuterium-ions and alpha particles and pulse shape discrimination in deuterated trans-stilbene

We characterized the light output response of a new 140 cm 3 stilbene-d 12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6 MeV energy range. The excellent PSD capability of the stilbene-d 12 detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks’ quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

36 MATERIALS SCIENCE↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗