Search NASA⌕ Search

SEARCH · Search NASA

Results for “pumped storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Solar-heating and cooling system design package

Package of information includes design data, performance specifications, drawings, hazard analysis, and spare parts list for commercially produced system installed in single-family dwelling in Akron, Ohio. System uses air flat-plate collectors, 12000 kg rock storage and backup heat pump. Solar portion requires 0.7 kW, and provides 35% of average total heating load including hot water. Information aids persons considering installing solar home-heating systems.

Source record↗

Benefit assessment of solar-augmented natural gas systems

Report details how solar-energy-augmented system can reduce natural gas consumption by 40% to 70%. Applications discussed include: domestic hot water system, solar-assisted gas heat pumps, direct heating from storage tank. Industrial uses, solar-assisted appliances, and economic factors are discussed.

Davis, E. S.↗

Solar hot water system installed at Quality Inn, Key West, Florida

The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.

Source record↗

Solar hot water system installed at Days Inn Motel, Dallas, Texas (Forrest Lane)

The solar system was designed to provide 65 percent of the total Domestic Hot Water (DHW) demand. The liquid flat plate (water) collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank located in the mechanical room when the pump is not running. Heat is transferred from the storage tank to DHW tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and the heat exchanger enables solar heated water to help make DHW tank standby losses. All pumps are controlled by differential temperature.

Source record↗

Correlation Analysis Of Vibration Data From Rotary Pumps

Correlation technique represents vibration data from rotary pumps in compact form convenient for storage in data base. Analysis determines coefficients of Fourier series representing typical response of pump for one revolution of pump shaft. Changes in harmonic spectrum of pump indicates changes in performance caused by internal wear, rubbing of seals, and the like.

Fenwick, James R.↗

Phase Separators And Fountain-Effect Pumps For He 11

Fused-glass microchannel arrays for use as HE 11 phase separators and fountain-effect pumps. Microchannel devices for use in low-gravity storage and cooling systems containing superfluid helium. Phase separators and pumps take advantage of thermomechanical effect peculiar to He 11 in restricted spaces. By creating thermal gradient in porous plug, direction of flow reversed, turning phase separator into pump. However, addition of heat disadvantage. Thermal gradient created by using Peltier effect to transfer heat across array, removing heat from He 11 supply and overcoming undesirable addition of heat.

Whitehouse, Paul L.↗

Phase-Change Heat-Storage Module

Heat-storage module accommodates momentary heating or cooling overload in pumped-liquid heat-transfer system. Large heat-storage capacity of module provided by heat of fusion of material that freezes at or near temperature desired to maintain object to be heated or cooled. Module involves relatively small penalties in weight, cost, and size and more than compensates by enabling design of rest of system to handle only average load. Latent heat of fusion of phase-change material provides large heat-storage capacity in small volume.

Mulligan, James C.↗

Design concept definition study for an improved shuttle waste collection subsystem

A no-risk approach for developing an Improved Waste Collection Subsystem (WCS) for the shuttle orbiter is described. The GE Improved WCS Concept builds on the experience of 14 Shuttle missions with over 400 man-days of service. This concept employs the methods of the existing flight-proven mature design, augmenting them to eliminate foreseen difficulties and to fully comply with the design requirements. The GE Improved WCS Concept includes separate storage for used wipes. Compaction of the wipes provides a solution to the capacity problem, fully satisfying the 210 man-day storage requirement. The added feature of in-flight serviceable storage space for the wipes creates a variable capacity feature which affords redundancy in the event of wipes compaction system failure. Addition of features permitting in-flight servicing of the feces storage tank creates a variable capacity WCS with easier post-flight servicing to support rapid turnaround of the Shuttle orbiter. When these features are combined with a vacuum pump to evacuate wipes and fecal storage tanks through replaceable odor/bacteria filters to the cabin, the GE Improved WCS satisfies the known requirements for Space Station use, including no venting to space.

Source record↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Cryogenic techniques for large superconducting magnets in space

A large superconducting magnet is proposed for use in a particle astrophysics experiment, ASTROMAG, which is to be mounted on the United States Space Station. This experiment will have a two-coil superconducting magnet with coils which are 1.3 to 1.7 meters in diameter. The two-coil magnet will have zero net magnetic dipole moment. The field 15 meters from the magnet will approach earth's field in low earth orbit. The issue of high Tc superconductor will be discussed in the paper. The reasons for using conventional niobium-titanium superconductor cooled with superfluid helium will be presented. Since the purpose of the magnet is to do particle astrophysics, the superconducting coils must be located close to the charged particle detectors. The trade off between the particle physics possible and the cryogenic insulation around the coils is discussed. As a result, the ASTROMAG magnet coils will be operated outside of the superfluid helium storage tank. The fountain effect pumping system which will be used to cool the coil is described in the report. Two methods for extending the operating life of the superfluid helium dewar are discussed. These include: operation with a third shield cooled to 90 K with a sterling cycle cryocooler, and a hybrid cryogenic system where there are three hydrogen-cooled shields and cryostat support heat intercept points.

Green, M. A.↗

The fountain effect in aerospace cryogenics

The theory of the fountain effect, also known as the thermomechanical effect, exhibited by superfluid helium is presented, and the application of this effect in space projects is described. Future uses of superfluid He in space are also discussed. These include the use of the fountain effect for liquid-vapor phase separation; for pumping superfluid helium from a storage vessel to a payload (as in the Superfluid Helium On-Orbit Transfer Flight Demonstration and the Superfluid Helium Tanker); for actuating a low-temperature refrigerator; and for circulating liquid helium within a cryostat (as in the Astromag dewar).

Castles, S. H.↗

Zero-G Thermodynamic Venting System (TVS) Performance Prediction Program

This report documents the Zero-g Thermodynamic Venting System (TVS) performance prediction computer program. The zero-g TVS is a device that destratifies and rejects environmentally induced zero-g thermal gradients in the LH2 storage transfer system. A recirculation pump and spray injection manifold recirculates liquid throughout the length of the tank thereby destratifying both the ullage gas and liquid bulk. Heat rejection is accomplished by the opening of the TVS control valve which allows a small flow rate to expand to a low pressure thereby producing a low temperature heat sink which is used to absorb heat from the recirculating liquid flow. The program was written in FORTRAN 77 language on the HP-9000 and IBM PC computers. It can be run on various platforms with a FORTRAN compiler.

Nguyen, Han↗

Thermal control systems for low-temperature heat rejection on a lunar base

One of the important issues in the design of a lunar base is the thermal control system (TCS) used to reject low-temperature heat from the base. The TCS ensures that the base and the components inside are maintained within an acceptable temperature range. The temperature of the lunar surface peaks at 400 K during the 336-hour lunar day. Under these circumstances, direct dissipation of waste heat from the lunar base using passive radiators would be impractical. Thermal control systems based on thermal storage, shaded radiators, and heat pumps have been proposed. Based on proven technology, innovation, realistic complexity, reliability, and near-term applicability, a heat pump-based TCS was selected as a candidate for early missions. In this report, Rankine-cycle heat pumps and absorption heat pumps (ammonia water and lithium bromide-water) have been analyzed and optimized for a lunar base cooling load of 100 kW.

Sridhar, K. R.↗

A Conceptual Design Study on the Application of Liquid Metal Heat Transfer Technology to the Solar Thermal Power Plant

Alkali metal heat transfer technology was used in the development of conceptual designs for the transport and storage of sensible and latent heat thermal energy in distributed concentrator, solar Stirling power conversion systems at a power level of 15 kWe per unit. Both liquid metal pumped loop and heat pipe thermal transport were considered; system configurations included: (1) an integrated, focal mounted sodium heat pipe solar receiver (HPSR) with latent heat thermal energy storage; (2) a liquid sodium pumped loop with the latent heat storage, Stirling engine-generator, pump and valves located on the back side of the concentrator; and (3) similar pumped loops serving several concentrators with more centralized power conversion and storage. The focus mounted HPSR was most efficient, lightest and lowest in estimated cost. Design confirmation testing indicated satisfactory performance at all angles of inclination of the primary heat pipes to be used in the solar receiver.

Zimmerman, W. F.↗

Studies of blackbody-pumped lasers

Laser action was achieved in a large-scale pulsed system and meaningful experiments were carried out in the axial flow facility to understand the physics of solar-pumped lasers. Studies of the variation of laser mixture composition were done for mixtures of CO2 and N2O additions. Theoretical analysis and modeling of the system were also performed based on a model including radiative pumping, diffusion and wall deactivation, and vibrational energy transfer between two optically active species. Qualitative agreement between predictions in the parameter variation and the experimental results were obtained with CO and N2O mixtures. Several experimental studies were performed to quantify the properties of carbon monoxide as absorber and storage of energy in the blackbody pumped system.

Christiansen, W. H.↗

Vacuum Pump-Down of the Annular Insulation Space for Large Field-Erected Liquid Hydrogen Storage Tanks

Insulation systems are critical to liquid hydrogen storage tank performance. Tanks in the capacity range of 100 to 1,000 m 3 are typically shop built and designed with high-vacuum (HV) multi-layer insulation (MLI), whereas storage vessels larger than 1,000 m 3 are typically field-erected and supplied with bulk fill insulation working at moderate vacuum (MV) levels (1-100 millitorr). For large, field-erected vessels, two types of bulk fill insulation typically used: perlite and hollow glass microspheres (glass bubbles). Selection of either material is driven by a tradeoff between CAPEX and OPEX, such as the material and construction cost versus operating thermal performance and maintenance. In either case, the vacuum level needed to achieve optimum performance is likely to drive the field testing and commissioning portion of the construction schedule. A primary goal of this paper is to present practical experience and data for warm vacuum pressure (WVP) and cold vacuum pressure (CVP) levels. Recommended WVP levels needed prior to cooldown consider both perlite powder and glass bubbles. Pumping time expected to achieve target vacuum levels, considering a variety of factors, is also discussed. Recommendations for a standard practice in vacuum-insulated tank commissioning are based on historical NASA data, and those collected during recent projects.

A M Swanger↗

Development and Testing of the CRYOTSU Flight Experiment

This paper describes the development and ground testing of the CRYOTSU thermal management flight experiment. CRYOTSU incorporates three cryogenic temperature experiments and one ambient temperature experiment into a Hitchhiker (HH) Get Away Special (GAS) Canister that is currently scheduled to fly on STS-95 in October 1998. The cryogenic experiments consist of a nitrogen triple-point cryogenic thermal storage unit (CTSU), a nitrogen cryogenic capillary pumped loop (CCPL), and a hydrogen gas-gap cryogenic thermal switch (CTSW). The ambient experiment is a carbon-fiber core, paraffin-filled thermal storage unit. Test results of integrated flight canister testing are provided herein for the CTSU and CCPL experiments. Pre-integration laboratory test results are provided for the CTSW. Design information and test results for the ambient experiment are not included.

Bugby, David C.↗

Development and Testing of the CRYOTSU Flight Experiment

This paper describes the development and ground testing of the CRYOTSU thermal management flight experiment. CRYOTSU incorporates three cryogenic temperature experiments and one ambient temperature experiment into a Hitchhiker (HH) Get Away Special (GAS) Canister that is currently scheduled to fly on STS-95 in October 1998. The cryogenic experiments consist of a nitrogen triple-point cryogenic thermal storage unit (CTSU), a nitrogen cryogenic capillary pumped loop (CCPL) and a hydrogen gas-gap cryogenic thermal switch (CTSW). The ambient experiment is a carbon-fiber core, paraffin-filled thermal storage unit. Test results of integrated flight canister testing are provided herein for the CTSU and CCPL experiments. Pre-integration laboratory test results are provided for the CTSW. Design information and test results for the ambient experiment are not included.

Bugby, David C.↗