Remote Heat Flux Measurement Using a Self Calibration Multiwavelength Pyrometer and a Transparent Material

A self calibrating multiwavelength pyrometer was used to conduct remote heat flux measurements using a transparent sapphire disk by determining the sapphire disk's front and back surface temperatures. Front surface temperature (Tfs) was obtained from detection of surface emitted radiation at long wavelengths (lambda > 6 micrometers). Back surface temperature (Tbs) was obtained from short wavelength (1 to 5 micrometers) radiation transmitted through the sapphire disk. The thermal conductivity k of the sapphire disk and the heat transfer coefficients h(sub 1) and h(sub 2) of its surfaces are determined experimentally. An analysis of the heat flux measurement is presented.

Ng, Daniel↗

Polaradiometric pyrometer in which the parallel and perpendicular components of radiation reflected from an unpolarized light source are equalized with the thermal radiation emitted from a measured object to determine its true temperature

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) =I(sub 1p) + I(sub 2p) and I(sub s)=I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

High resolution color band pyrometer ratioing

The sensing head of a two-color band ratioing pyrometer of a known type using a fiber optic cable to couple radiation to dual detector photodiodes is improved to have high spatial resolution by focusing the radiation received through an objective lens (i.e., by focusing the image of a target area) onto an opaque sheet spaced in front of the input end of the fiber optic cable. A two-mil hole in that sheet then passes radiation to the input end of the cable. The detector has two channels, one for each color band, with an electronic-chopper stabilized current amplifier as the input stage followed by an electronic-chopper stabilized voltage amplifier.

Bickler, Donald B.↗

A Plenoptic Multi-Color Imaging Pyrometer

A three-color pyrometer has been developed based on plenoptic imaging technology. Three bandpass filters placed in front of a camera lens allow separate 2D images to be obtained on a single image sensor at three different and adjustable wavelengths selected by the user. Images were obtained of different black- or grey-bodies including a calibration furnace, a radiation heater, and a luminous sulfur match flame. The images obtained of the calibration furnace and radiation heater were processed to determine 2D temperature distributions. Calibration results in the furnace showed that the instrument can measure temperature with an accuracy and precision of 10 Kelvins between 1100 and 1350 K. Time-resolved 2D temperature measurements of the radiation heater are shown.

Danehy, Paul M.↗

System and method for multi-channel pyrometer allowing non-contact temperature measurements down to 800 K on the microsecond scale

The present disclosure relates to a system for sensing temperature changes on a microsecond scale. The system uses a multi-channel pyrometer that works in the NIR spectrum to receive thermal radiation. Each channel includes an interference filter tuned to pass thermal radiation within a specified wavelength range, and a detector. Each detector detects thermal radiation focused on it. Each channel further includes an interference filter which reflects thermal radiation which does not pass through it to a subsequent downstream interference filter of a subsequent channel. Each subsequent interference filter is oriented to reflect the thermal radiation not passing through it to a next downstream one of the subsequent interference filters. A subsystem is included for receiving the output from the detectors and determining sensed temperature data therefrom, allowing measurement of temperatures down to 800 K.

Montgomery, Jeffrey↗

Evaluation of a novel mid-infrared pyrometer for dynamic material experiments

Dynamic experiments create high-pressure shock waves on the microsecond time scale (or smaller), compressing materials to high pressures and temperatures and enabling the study of material properties at these conditions. Other dynamic studies use quasi-isentropic compression to produce similar high pressures at much lower temperatures. High pressure experiments performed on dynamic platforms such as gas-guns, laser, and pinch machines generate up to several hundred GPa in the sample pressure conditions12. Related static studies include diamond anvil cells, which obtain high pressures and have extremely high precision, but are most often conducted at room temperature or modest temperature increases (often <2000K). By combining these methods, material properties across a wide range of thermodynamic conditions can be probed, and a high quality equation of state (EOS) constructed.

36 MATERIALS SCIENCE↗

Detection of effect of deposits on optical windows of pyrometer measurements

Temperatures measurements in an enclosed test chamber are more accurate when the reflectivity of the inner coated surface is compared to the outer clean surface of an optical window. Temperature readings are corrected by correlating the reflectivity of the deposits with their effect on the temperature measurement.

Cipolone, P.↗

Pyrometer for measurement of surface temperature distribution on a rotating turbine blade

A conceptual optical method and some test results are presented for measuring the surface temperature distribution on one of the rotating turbine blades with a surface resolution of 0.05 cm spot diameter at a tip speed of 400 m/sec. The blade is scanned line-by-line by a fixed optical system. During each line-scan, the detector analog output signal is converted to two hundred consecutive digital values that are temporarily stored in a high speed buffer memory, and then transferred at a slower rate to a computer for processing. The signal-to-noise ratio of the silicon avalanche detector is large enough to obtain an accuracy of one percent at 1050 K blade temperature. By averaging 25 scans of the same line the same accuracy can be obtained at 900 K.

Buchele, D. R.↗

Pyrometer for measurement of surface temperature distribution on a rotating turbine blade.

A conceptual optical method and some test results are presented for measuring the surface temperature distribution on one of the rotating turbine blades with a surface resolution of 0.05 cm spot diameter at a tip speed of 400 m/sec. The blade is scanned line-by-line by a fixed optical system. During each line-scan, the detector analog output signal is converted to 200 consecutive digital values that are temporarily stored in a high-speed buffer memory and then transferred at a slower rate to a computer for processing. The signal-to-noise ratio of the silicon avalanche detector is large enough to obtain an accuracy of 1% at 1050 K blade temperature. By averaging 25 scans of the same line the same accuracy can be obtained at 900 K.

Buchele, D. R.↗

Radiation pyrometer for gas turbine blades

A turbine blade temperature measuring system for liquid oxygen turbopumps is reported. The system includes a three mode, two-input optical signal processor, interconnecting cable, and four sensor heads. Two of the heads are aperture type, while the other two are lens type. This system is applicable to a temperature range of 1400 to 2200 F.

Rohy, D. A.↗

Multiwavelength pyrometer for gray and non-gray surfaces in the presence of interfering radiation

A method and apparatus for detecting the temperature of gray and non-gray bodies in the presence of interfering radiation are presented. A gray body has a constant emissivity less than 1 and a non-gray body has an emissivity which varies with wavelength. The emissivity and reflectivity of the surface is determined over a range of wavelengths. Spectra are also measured of the extraneous interference radiation source and the surface of the object to be measured in the presence of the extraneous interference radiation source. An auxiliary radiation source is used to determine the reflectivity of the surface and also the emissivity. The measured spectrum of the surfaces in the presence of the extraneous interference radiation source is set equal to the emissivity of the surface multiplied by a Planck function containing a temperature term T plus the surface reflectivity multiplied by the spectrum of the extraneous interference radiation source. The equation is then solved for T to determine the temperature of the surface.

Ng, Daniel L. P.↗

Noncontact temperature pattern measuring device

Laser pyrometer techniques are utilized to accurately image a true temperature distribution on a given target without touching the target and without knowing the localized emissivity of the target. The pyrometer utilizes a very high definition laser beam and photodetector, both having a very narrow focus. The pyrometer is mounted in a mechanism designed to permit the pyrometer to be aimed and focused at precise localized points on the target surface. The pyrometer is swept over the surface area to be imaged, temperature measurements being taken at each point of focus.

Elleman, Daniel D.↗

Noncontact measurement of high temperature using optical fiber sensors

The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

Claus, R. O.↗