Search NASA⌕ Search

SEARCH · Search NASA

Results for “random reversal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

63 records · Page 4

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. This suite included a network of MEDLI2 Instrumented Sensor Plugs (MISPs). Each MISP was comprised of a cylinder made of Thermal Protection System (TPS) material with 1-3 embedded thermocouples (TCs), and it was flush mounted into the heatshield or backshell. Data from these in-depth TCs were used to reconstruct the aeroheating environment of the vehicle throughout entry. Surface heating was posed as an inverse problem, with the goal of estimating the surface heating by minimizing an objective function of the difference between MISP temperature measurements during flight and the temperature predictions derived from the Fully Implicit Ablation and Thermal response (FIAT) program. Given an aerothermal environment, FIAT calculates the material response and provides in-depth temperatures throughout the TPS material. To achieve the reverse, an internal tool called FIAT_Opt runs through multiple different environments until the output temperature at the TC depth closely matches the flight data. 95% confidence intervals on the reconstructed surface heating were obtained using Monte Carlo analysis, in which uncertainties in the thermocouple depth and the TPS material properties (e.g., density, thermal conductivity, heat capacity, emissivity) based on flight-lot material testing were included. A variance decomposition method using Sobol indices was employed to assess the sensitivity of the reconstructed peak heating to the TC placement and material property uncertainties. Variance decomposition was found to require tens of thousands of FIAT_Opt runs in order for the Sobol indices to converge. With a single FIAT_Opt run taking on the order of 40 minutes, the required number of computations would take months to complete, even if using multiple CPUs. To mitigate this problem, three machine learning models (ridge regression with cross-validation, random forest regression, and a deep neural network) were trained and tested using the 2000 Monte Carlo runs that were already completed. A subset of 1600 runs were used to train the model (i.e., training set), while the remaining 400 runs were used as the test set. The predictions from the deep neural network (DNN) on the test set showed nearly perfect agreement to the actual values computed with FIAT_Opt (R2 > 0.99). Using the DNN as a surrogate model, the variance decomposition using 50,000 runs was completed within minutes. The resulting Sobol indices showed that the reconstructed peak surface heating was most sensitive to the uncertainties in the thermal conductivity (ST = 0.37) and heat capacity (ST = 0.26). This method can be leveraged to provide requirements for material property measurements needed to improve the accuracy of surface heating prediction and ultimately lead to the reduction of design margins in the future. This presentation will include background on the MEDLI2 suite; the method used for inverse heating estimation; the way that material property uncertainties were accounted for using Monte Carlo analysis; a brief background on variance decomposition; the motivation for using machine learning in this context; how a neural network was trained on the data to enable variance decomposition in a fraction of the time; and the variance decomposition results for one of the MISPs.

Hannah Alpert↗

A petabyte size electronic library using the N-Gram memory engine

A model library containing petabytes of data is proposed by Triada, Ltd., Ann Arbor, Michigan. The library uses the newly patented N-Gram Memory Engine (Neurex), for storage, compression, and retrieval. Neurex splits data into two parts: a hierarchical network of associative memories that store 'information' from data and a permutation operator that preserves sequence. Neurex is expected to offer four advantages in mass storage systems. Neurex representations are dense, fully reversible, hence less expensive to store. Neurex becomes exponentially more stable with increasing data flow; thus its contents and the inverting algorithm may be mass produced for low cost distribution. Only a small permutation operator would be recalled from the library to recover data. Neurex may be enhanced to recall patterns using a partial pattern. Neurex nodes are measures of their pattern. Researchers might use nodes in statistical models to avoid costly sorting and counting procedures. Neurex subsumes a theory of learning and memory that the author believes extends information theory. Its first axiom is a symmetry principle: learning creates memory and memory evidences learning. The theory treats an information store that evolves from a null state to stationarity. A Neurex extracts information data without a priori knowledge; i.e., unlike neural networks, neither feedback nor training is required. The model consists of an energetically conservative field of uniformly distributed events with variable spatial and temporal scale, and an observer walking randomly through this field. A bank of band limited transducers (an 'eye'), each transducer in a bank being tuned to a sub-band, outputs signals upon registering events. Output signals are 'observed' by another transducer bank (a mid-brain), except the band limit of the second bank is narrower than the band limit of the first bank. The banks are arrayed as n 'levels' or 'time domains, td.' The banks are the hierarchical network (a cortex) and transducers are (associative) memories. A model Neurex was built and studied. Data were 50 MB to 10 GB samples of text, data base, and images: black/white, grey scale, and high resolution in several spectral bands. Memories at td, S(m(sub td)), were plotted against outputs of memories at td-1. S(m(sub td)) was Boltzman distributed, and memory frequencies exhibited self-organized criticality (SOC); i.e., 'l/f(sup beta)' after long exposures to data. Whereas output signals from level n may be encoded with B(sub output) = O(-log(2)f(sup beta)) bits, and input data encoded with B(sub input) = O((S(td)/S(td-1))(sup n)), B(sup output)/B(sub input) is much less than 1 always, the Neurex determines a canonical code for data and it is a lossless data compressor. Further tests are underway to confirm these results with more data types and larger samples.

Bugajski, Joseph M.↗

Snowex 2017 Community Snow Depth Measurements: A Quality-Controlled, Georeferenced Product

Snow depth was one of the core ground measurements required to validate remotely-sensed data collected during SnowEx Year 1, which occurred in Colorado. The use of a single, common protocol was fundamental to produce a community reference dataset of high quality. Most of the nearly 100 Grand Mesa and Senator Beck Basin SnowEx ground crew participants contributed to this crucial dataset during 6-25 February 2017. Snow depths were measured along ~300 m transects, whose locations were determined according to a random-stratified approach using snowfall and tree-density gradients. Two-person teams used snowmobiles, skis, or snowshoes to travel to staked transect locations and to conduct measurements. Depths were measured with a 1-cm incremented probe every 3 meters along transects. In shallow areas of Grand Mesa, depth measurements were also collected with GPS snow-depth probes (a.k.a. MagnaProbes) at ~1-m intervals. During summer 2017, all reference stake positions were surveyed with <10 cm accuracy to improve overall snow depth location accuracy. During the campaign, 193 transects were measured over three weeks at Grand Mesa and 40 were collected over two weeks in Senator Beck Basin, representing more than 27,000 depth values. Each day of the campaign depth measurements were written in waterproof field books and photographed by National Snow and Ice Data Center (NSIDC) participants. The data were later transcribed and prepared for extensive quality assessment and control. Common issues such as protocol errors (e.g., survey in reverse direction), notebook image issues (e.g., halo in the center of digitized picture), and data-entry errors (sloppy writing and transcription errors) were identified and fixed on a point-by-point basis. In addition, we strove to produce a georeferenced product of fine quality, so we calculated and interpolated coordinates for every depth measurement based on surveyed stakes and the number of measurements made per transect. The product has been submitted to NSIDC in csv format. To educate data users, we present the study design and processing steps that have improved the quality and usability of this product. Also, we will address measurement and design uncertainties, which are different in open vs. forest areas.

Brucker, L.↗

Folding and translocation of the undecamer of poly-L-leucine across the water-hexane interface. A molecular dynamics study

The undecamer of poly-L-leucine at the water-hexane interface is studied by molecular dynamics simulations. This represents a simple model relevant to folding and insertion of hydrophobic peptides into membranes. The peptide, initially placed in a random coil conformation on the aqueous side of the system, rapidly translocates toward the hexane phase and undergoes interfacial folding into an alpha-helix in the subsequent 36 ns. Folding is nonsequential and highly dynamic. The initially formed helical segment at the N-terminus of the undecamer becomes transiently broken and, subsequently, reforms before the remainder of the peptide folds from the C-terminus. The formation of intramolecular hydrogen bonds during the folding of the peptide is preceded by a dehydration of the participating polar groups, as they become immersed in hexane. Folding proceeds through a short-lived intermediate, a 3(10)-helix, which rapidly interconverts to an alpha-helix. Both helices contribute to the equilibrium ensemble of folded structures. The helical peptide is largely buried in hexane, yet remains adsorbed at the interface. Its preferred orientation is parallel to the interface, although the perpendicular arrangement with the N-terminus immersed in hexane is only slightly less favorable. In contrast, the reversed orientation is highly unfavorable, because it would require dehydration of C-terminus carbonyl groups that do not participate in intramolecular hydrogen bonding. For the same reason, the transfer of the undecamer from the interface to the bulk hexane is also unfavorable. The results suggest that hydrophobic peptides fold in the interfacial region and, simultaneously, translocate into the nonpolar side of the interface. It is further implied that peptide insertion into the membrane is accomplished by rotating from the parallel to the perpendicular orientation, most likely in such a way that the N-terminus penetrates the bilayer.

NASA Discipline Exobiology↗

Electrical Switching of Perovskite Thin-Film Resistors

Electronic devices that exploit electrical switching of physical properties of thin films of perovskite materials (especially colossal magnetoresistive materials) have been invented. Unlike some related prior devices, these devices function at room temperature and do not depend on externally applied magnetic fields. Devices of this type can be designed to function as sensors (exhibiting varying electrical resistance in response to varying temperature, magnetic field, electric field, and/or mechanical pressure) and as elements of electronic memories. The underlying principle is that the application of one or more short electrical pulse(s) can induce a reversible, irreversible, or partly reversible change in the electrical, thermal, mechanical, and magnetic properties of a thin perovskite film. The energy in the pulse must be large enough to induce the desired change but not so large as to destroy the film. Depending on the requirements of a specific application, the pulse(s) can have any of a large variety of waveforms (e.g., square, triangular, or sine) and be of positive, negative, or alternating polarity. In some applications, it could be necessary to use multiple pulses to induce successive incremental physical changes. In one class of applications, electrical pulses of suitable shapes, sizes, and polarities are applied to vary the detection sensitivities of sensors. Another class of applications arises in electronic circuits in which certain resistance values are required to be variable: Incorporating the affected resistors into devices of the present type makes it possible to control their resistances electrically over wide ranges, and the lifetimes of electrically variable resistors exceed those of conventional mechanically variable resistors. Another and potentially the most important class of applications is that of resistance-based nonvolatile-memory devices, such as a resistance random access memory (RRAM) described in the immediately following article, Electrically Variable Resistive Memory Devices (MFS-32511-1).

Liu, Shangqing↗

NASA Tech Briefs, November 1995

The contents include: 1) Mission Accomplished; 2) Resource Report: Marshall Space Flight Center; 3) NASA 1995 Software of the Year Award; 4) Microbolometers Based on Epitaxial YBa2Cu3O(sub 7-x) Thin Films; 5) Garnet Random-Access Memory; 6) Fabrication of SNS Weak Links on SOS Substrates; 7) High-Voltage MOSFET Switching Circuit; 8) Asymmetric Switching for a PWM H-Bridge Power Circuit; 9) Better Ohmic Contacts for InP Semiconductor Devices; 10) Low-Bandgap Thermovoltaic Materials and Devices; 11) Digital Frequency-Differencing Circuit; 12) Imaging Magnetometer; 13) Computer-Assisted Monitoring of a Complex System; 14) Buffered Telemetry Demodulator; 15) Compact Multifunction Inspection Head; 16) Optical Detection of Fractures in Ceramic Diaphragms; 17) Eddy-Current Detection of Cracks in Reinforced Carbon/Carbon; 18) Apparent Thermal Conductivity of Multilayer Insulation; 19) Optimizing Misch-Metal Compositions in Metal Hydride Anodes; 20) Device for Sampling Surface Contamination; 21) Probabilistic Failure Assessment for Fatigue; 22) Probabilistic Fatigue and Flaw-Propagation Analysis; 23) Windows Program for Driving the TDU-850 Printer; 24) Subband/Transform MATLAB Functions for Processing Images; 25) Computing Equilibrium Chemical Compositions; 26) Program Processes Thermocouple Readings; 27) ICAN-Second-Generation Integrated Composite Analyzer; 28) Integrated Composite Analyzer with Damping Capabilities; 29) Computing Efficiency of Transfer of Microwave Power; 30) Program Calculates Power Demands of Electronic Designs; 31) Cost-Estimation Program; 32) Program Estimates Areas Required by Electronic Designs; 33) Program to Balance Mapped Turbopump Assemblies; 34) BiblioTech; 35) Controlling Mirror Tilt With a Bimorph Actuator; 36) Burst-Disk Device Simulates Effect of Pyrotechnic Device; 37) Bearing-Mounting Concept Accommodates Thermal Expansion; 38) Parallel-Plate Acoustic Absorbers for Hot Environments; 39) Adjustable-Length Strut Withstands Large Cyclic Loads; 40) Tool Indicates Contact Angles in Bearing Raceways; 41) Gravity Slides With Magnetic Braking; 42) High-Torque, Lightweight, Pneumatically Driven Wrench for Small Spaces; 43) Device for Testing Compatibility of an O-Ring; 44) Magnetic Heat Pump Containing Flow Diverters; 45) Variable-Tilt Helicopter Rotor Mast; 46) "Beach-Ball" Robotic Rovers; 47) Apparatus Would Measure Temperatures of Ball Bearings; 48) Flexible Borescope for Inspecting Ducts; 49) Texturing Copper To Reduce Secondary Emission of Electrons; 50) Automated Laser Cutting in Three Dimensions; 51) Algorithm Helps Monitor Engine Operation; 52) Flexible Revision of Data-Processing Communications; 53) Software for Managing the Use of Land; 54) Thermal Strap Increases Cryocooling Efficiency; 55) Reversible Nut With Engagement Indication; 56) Control Algorithms for Kinematically Redundant Manipulators; 57) Computed Hydrogen-Flow Splits in a Rocket Engine; 58) Pressure and Thermal Modeling of Rocket Launches; 59) Field of View of a Spacecraft Antenna: Analysis and Software; 60) Digital Controller for Laser-Beam-Steering Subsystem; 61) More About Beam-Steering Subsystem for Laser Communication; 62) Digital Controller for Laser-Beam-Steering Subsystem: Part 2; 63) Interface Circuit Board for Space-Shuttle Communications; 64) Automated Planning of Spacecraft Telecommunications; 65) Artifacts of Spectral Analysis of Instrument Readings; 66) Neural-Network Controller for Vibration Suppression; 67) Adaptive Finite-Element Computation in Fracture Mechanics; 68) Attitude Control for the Cassini Spacecraft; 69) Analytical Model for Fluid Dynamics in a Microgravity Environment; 70) Study of Rocket-Engine Joints Bonded by NVCU/NARloy-Z; 71) Improved Silicon Nitride for Advanced Heat Engines; 72) Parameters for Welding Aluminum/Lithium Alloys; 73) Lightweight Composite Intertank Structure; 74) Foil Patches Seal Small Vacuum Leaks; 75) Data Base on Cables and Connectors; 76) Effect of Clock Mode on Radiation Hardnessf an ADC; and 77) Fault-Tolerant Control for a Robotic Inspection System.

Source record↗

Mitigating Headward Fluid Shifts with Venoconstrictive Thigh Cuffs during Spaceflight

Venoconstrictive thigh cuffs (VTC) are a mechanical countermeasure capable of attenuating the spaceflight induced headward fluid shift, and thus may be a viable spaceflight associated neuro-ocular syndrome (SANS) countermeasure. Crewmembers can use VTC to mitigate the headward fluid shift to aid in adapting to spaceflight. However, data are needed to determine if VTC affect ocular structures. PURPOSE The purpose of this study is to determine the efficacy of long duration use of VTC application to mitigate the spaceflight-induced headward fluid shift. We hypothesize that a VTC countermeasure will temporarily reverse the headward fluid shift and attenuate spaceflight-induced changes of internal jugular vein (IJV) cross-sectional area, IJV pressure, stroke volume, cardiac output, intraocular pressure (IOP), and optic nerve head and retinal morphology. METHODS This study will evaluate the effectiveness of VTC countermeasure application on the headward fluid shift, as well as cardiovascular and ocular variables. VTC during spaceflight will be worn for an extended duration (up to 6 hours) with data collected at three time points (30 minutes, 3 hours, and 6 hours) to characterize the temporal profile of key fluid shift outcome measures of the vascular fluid shift, IOP, and ocular structure changes. Ten astronauts will be recruited to participate and will be studied before and during approximately 180-day International Space Station (ISS) spaceflight missions. Baseline data collection will occur approximately 90-days before launch (Figure). Preflight, each leg of the crewmember will be measured to determine the VTC cuff size and a cuff fit check session will occur prior to the preflight baseline ground imaging to verify the appropriate fit measured via a surface contact pressure. Prior to donning the VTC, baseline measures without VTC will be collected seated, supine, and supine followed by data collection with the VTC. The baseline data collection will include ultrasound (IJV area and pressure, stroke volume and cardiac output), brachial blood pressure and heart rate, optical coherence tomography (OCT) imaging (total retinal thickness and choroid thickness), and IOP. An inflight cuff fit check session, same as the preflight fit check, will occur prior to VTC use on ISS. The inflight VTC experiment will be conducted early (FD45) and late (R-45) to determine if mission duration affects VTC fit and the efficacy of fluid redistribution. A system usability scale comfort questionnaire will be included in each VTC session to capture feedback from crewmembers regarding the comfort and usability of the VTC. SCIENTIFIC & MISSION IMPACT Results will narrow knowledge gaps described in the Human Research Roadmap to mitigate the headward fluid shift during spaceflight and help NASA to 1) determine the efficacy of extended use VTC application to mitigate the spaceflight-induced headward fluid shift and 2) further the understanding of the use of VTC on vascular fluid shifts, IOP, and ocular structure during spaceflight. Supported by NASA Human Research Program Directed Research. Figure. Detailed Testing Schedule. Baseline data collection at L-90 will be performed in a randomized order of position.

J V Jasien↗

Configuration and Intraseasonal Duration of Interannual Anomalies of the Great Plains Low-Level Jet

Despite the fact that the low-level jet of the southern Great Plains (the GPLLJ) of the U.S. is primarily a nocturnal phenomenon that virtually vanishes during the daylight hours, it is one of the most persistent and stable climatological features of the low-level continental flow during the warm-season months, May through August. We have used significant-level data to validate the skill of the GEOS-1 Data Assimilation System (DAS) in realistically detecting this jet and inferring its structure and evolution. We have then carried out a 15-year reanalysis with the GEOS-1 DAS to determine its climatology and mean diurnal cycle and to study its interannual variability. Interannual anomalies of the meridional flow associated with the GPLLJ are much smaller than the mean diurnal fluctuations, than random intraseasonal anomalies, and than the mean wind itself. There are three maxima of low-level meridional flow variance over the Great Plains and the Gulf of Mexico: a 1.2 m2 s-2 peak over the southeast Texas, to the east and south of the mean velocity peak, a 1.0 m2 s-2 peak over the western Gulf of Mexico, and a .8 m2 s-2 peak over the upper Great Plains (UGP), near the Nebraska/South Dakota border. Each of the three variance maxima corresponds to a spatially coherent, jet-like pattern of low-level flow interannual variability. There are also three dominant modes of interannual variability corresponding to the three variance maxima, but not in a simple one-to-one relationship. Cross-sectional profiles of mean southerly wind over Texas remain relatively stable and recognizable from year to year with only its eastward flank showing significant variability. This variability, however, exhibits a distinct, biennial oscillation during the first six to seven years of the reanalysis period and only then. This intermittent biennial oscillation (IBO, one of the three modes discussed in the previous paragraph) in the lowlevel flow is restricted to the region surrounding eastern Texas and is also evident in the NCEP/NCAR reanalysis data set from about 1978 to 1985 or 1986 and again from 1995 to 2000. It is evident as well in surface pressure in both the GEOS-1 and NCEP/NCAR sets. The interannual anomalies do not necessarily persist uniformly throughout an entire season, but can fluctuate from one part of the season to the next. To estimate the characteristic sub-seasonal time scales for coherence of these fluctuations, we have taken the weekly anomaly of low-level wind at each point of the domain from the climatological average for that given point and that given week of the season and computed the covariance of its fluctuations over all weeks and over all years with the weekly climatological anomaly of the meridional wind at each of the three reference points discussed above. The typical duration of a coherent interannual anomaly within a given warm season increases with decreasing latitude from 2 to 3 weeks over the UGP, to 6 to 7 weeks over eastern Texas. Coherence over the western Gulf of Mexico is intermediate between the two with a typical duration of 4 to 5 weeks. There appears to be evidence that the interannual anomalies over Texas the Gulf propagate to the UGP after a week and those over the Gulf propagate there after 2 to 3 weeks. There also appears to be some reverse propagation of interannual anomalies over the UGP to Texas and to the Gulf after a period of about one week. The interannual anomalies in southerly flow over eastern Texas seem to correlate well with interannual anomalies of surface temperature and (negative) ground wetness and over western Texas.

Helfand, H. M.↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗