Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Targeted Quantitation of Protein Overexpression with Direct Infusion Shotgun Proteome Analysis (DISPA-PRM)

While much effort has been placed on comprehensive quantitative proteome analysis, certain applications demand measurement of only a few target proteins from complex systems. Traditional approaches to targeted proteomics rely on nano-liquid chromatography (nLC) and targeted mass spectrometry (MS) methods, e.g., parallel reaction monitoring (PRM). However, the time requirement for nLC can limit throughput of targeted proteomics. To achieve rapid and high-throughput targeted methods, here we show that nLC separations can be eliminated and replaced with direct infusion shotgun proteome analysis (DISPA) using high-field asymmetric waveform ion mobility spectrometry (FAIMS) with PRM. We demonstrate application of DISPA-PRM for rapid targeted quantification of bacterial enzymes utilized in the production of biofuels by monitoring temporal expression in 72 metabolically engineered bacterial cultures in under 2.5 hours, with a measured dynamic range >1200-fold. Here, we conclude that DISPA-PRM presents a valuable innovative tool with results comparable to nLC-MS/MS, enabling fast and rapid detection of targeted proteins in complex mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Earlier emergence of a temperature response to mitigation by filtering annual variability

The rate of global surface warming is crucial for tracking progress towards global climate targets, but is strongly influenced by interannual-to-decadal variability, which precludes rapid detection of the temperature response to emission mitigation. Here we use a physics based Green’s function approach to filter out modulations to global mean surface temperature from sea-surface temperature (SST) patterns, and show that it results in an earlier emergence of a response to strong emissions mitigation. For observed temperatures, we find a filtered 2011–2020 surface warming rate of 0.24 °C per decade, consistent with long-term trends. Unfiltered observations show 0.35 °C per decade, partly due to the El Nino of 2015–2016. Pattern filtered warming rates can become a strong tool for the climate community to inform policy makers and stakeholder communities about the ongoing and expected climate responses to emission reductions, provided an effort is made to improve and validate standardized Green’s functions.

58 GEOSCIENCES↗

Plasmonic photoconductive terahertz focal-plane array with pixel super-resolution

Abstract Imaging systems operating in the terahertz part of the electromagnetic spectrum are attractive due to their ability to penetrate many opaque materials and provide unique spectral signatures of various chemicals. However, the use of terahertz imagers in real-world applications has been limited by the slow speed, large size, high cost and complexity of present systems, largely due to the lack of suitable terahertz focal-plane array detectors. Here we report a terahertz focal-plane array that can directly provide the spatial amplitude and phase distributions, along with the ultrafast temporal and spectral information of an imaged object. It consists of a two-dimensional array of ~0.3 million plasmonic photoconductive nanoantennas optimized to rapidly detect broadband terahertz radiation with a high signal-to-noise ratio. We utilized the multispectral nature of the amplitude and phase data captured by these plasmonic nanoantennas to image different objects, including super-resolved etched patterns in a silicon substrate and defects in battery electrodes. By eliminating the need for raster scanning and spatial terahertz modulation, our terahertz focal-plane array offers more than a 1,000-fold increase in the imaging speed compared with the state of the art and potentially suits a broad range of applications in industrial inspection, security screening and medical diagnosis, among others.

Optics↗

Design, construction, and validation of an in-situ groundwater trace element analyzer with applications in carbon storage

Abstract It is estimated that carbon emissions should reach net-zero by 2050 to meet important climate targets. Carbon capture is likely necessary to reach these targets, requiring a long-term storage solution such as geological carbon sequestration. However, as with any subsurface activity, leakage can occur, potentially impacting groundwater quality near the storage site. Rapid detection is essential to mitigate damage to this resource. Since CO 2 will acidify groundwater, the concentrations of acid soluble minerals and associated cations will increase. Thus, an in-situ, real-time element analysis system based on laser-induced breakdown spectroscopy (LIBS) is under development to monitor these elements. The system splits the traditional LIBS system into a miniature, all-optical sensor head built around a passively Q-switch laser fiber coupled to a control unit. Previous work has validated the LIBS technique for use at high pressure as well as the split system design. In this work, a fieldable prototype sensor is developed and tested in an onsite monitoring well where trace elements concentrations (approx. 0–3 ppm) were tracked over 20 days. These concentrations varied in response to local rainfall, diluting with increased rain, demonstrating the ability of a LIBS-based sensor to track trace elements under real-world conditions.

54 ENVIRONMENTAL SCIENCES↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community

Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions. In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting. Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.

60 APPLIED LIFE SCIENCES↗

Automated nuclear cloud feature extraction from film

Chemical, biological, radiological, nuclear, and explosives incidents require rapid detection and characterization for appropriate response. For a nuclear detonation, visible-light cameras may be used to locate the cloud and characterize fallout deposition when coupled with numerical models. Films from the United States’ nuclear testing era compose the only sizeable collection of imagery depicting high-yield detonations. These films offer unique insights into characteristics of flows involving scales that are difficult to replicate experimentally, and they are a valuable source of data for the validation of models for nuclear fallout transport, either as part of emergency response or forensic activities. In this work, we implement modern computer vision and machine learning techniques to identify and track the cloud automatically and subsequently determine the time dependence of some of its features. We trained a ResNet-18 image classifier on hundreds of images to categorize nuclear cloud morphology. Each category or cloud regime is determined by early cloud evolution and is associated to constitutive properties of the flow, such as distribution of vorticity. Next, we identified keypoint features using the KAZE algorithm and tracked these keypoints in the images, allowing us to determine the dimensions and velocities of the cloud across film frames. These measurements converted to real-world units provide valuable experimental data that can be used in the development and validation of nuclear cloud models. We compared the results of this method against manual cloud rise measurements from two different films. In one, our automated method accelerated the feature extraction process without sacrificing measurement accuracy.

Khristy, Joel [ORNL] (ORCID:0000000209963060)↗

On the novel 3-D neutron transport kinetic tRAPID algorithm and its validation

The Real-time Analysis for Particle-transport and In-situ Detection (RAPID) Code System, based on the Multi-stage Response-function Transport (MRT) methodology, allows for real-time simulation of nuclear systems based on 3-D continuous-energy particle transport. RAPID's steady-state (criticality) neutron transport algorithm is based on the Fission Matrix (FM) method, and has been extensively verified and validated against computational benchmarks and experiments. This paper introduces the novel 3-D time-dependent transport algorithm that has been implemented into the code, tRAPID, and its validation using the JSI TRIGA Mark-II reactor. tRAPID accurately and efficiently calculates neutron kinetics parameters (such as β{sub eff}, l{sub eff} , Λ, α{sub Rossi}) and 3-D time-dependent neutron fission source distribution and neutron importances for both prompt and delayed neutrons. tRAPID is used to simulate a rod insertion experiment performed at the JSI TRIGA Mark-II reactor, during which signals from four fission chambers at four different locations in the core were collected. The results demonstrate how tRAPID is capable of calculating detailed and accurate results with only a minimal use computational resources and time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integration of seismic-pressure-petrophysics inversion of continuous active-seismic monitoring data for monitoring and quantifying CO 2 plume (Final Report)

The overall objective of this project is to develop and validate an integrated package of joint seismic-pressure-petrophysics inversion (jSPPI) of continuous active-source seismic monitoring dataset capable of providing real-time monitoring of CO 2 plume during geologic carbon sequestration (GCS). The three specific developments include: (a) the methodologies for fast seismic full waveform inversion of continuous active source seismic monitoring, (CASSM) datasets for simultaneously estimating velocity and attenuation, and with data assimilation; (b) joint Bayesian petrophysical inversion of seismic models and pressure data for providing and updating CO 2 saturation models; (c) the methods using multiple datasets including (Crainfield and Frio-II borehole) synthetic, laboratory, and field CASSM datasets. The outcomes of jSPPI include (a) a workflow for processing CASSM data, (b) Bayesian inversion algorithms using CASSM data and pressure response data, and (c) integration with data assimilation algorithms for continuously updating site-specific models used for prediction and reservoir management. The validation of joint FWI will be conducted using synthetic models based on the Cranfield and Frio experiments as well as field CASSM datasets collected as part of the Frio-II pilot injection. To quantify and map the mass and distribution of CO 2 (saturation), we will jointly invert velocity and attenuation measurements from the FWI with a Bayesian approach using a rock physics model for attenuation (e.g., White’s attenuation model with two selected patch sizes (White, 1976; Dutta and Seriff, 1979)). The Bayesian inversion will be applied to each time step in the CASSM survey in an updating scheme, which integrates with an ensemble of reservoir simulations at each step. A more complete experimental validation dataset will be collected as part of a mesoscale (2-3 m) gas-CO 2 injection experiment utilizing a higher frequency version of the CASSM system developed for laboratory studies; the integrated inversion will be demonstrated using this dataset which will provide both a dense geometry as well as more precise secondary confirmation measurements (e.g. saturation) typically not available in the field. The resulting real-time map of CO 2 saturation is able to provide a deeper scientific understanding of the complex, time-varying dynamics of subsurface fluid flow migration path as well as the rapid detection of CO 2 leakage hazards.

25 ENERGY STORAGE↗

Rapid Sensing to Facilitate Purification of Rare Earth Element-Containing Process Streams Produced Through Membrane-Assisted Solvent Extraction

The development of an economically competitive domestic supply of rare earth elements and yttrium (REY) is necessary for our nation’s economic growth and national security. The achievement of a secure domestic supply of REY requires not only the development of effective processes for recovery of REY from naturally occurring materials and/or recycled products, but also the development of downstream processes for the ultimate production of high-REY content solids. An impediment to the development of such processes is the scarcity of analytical methods that provide rapid determination of the process stream compositions. In this work, a membrane-based extraction process was used to selectively recover REYs from a dilute solution in the presence of much higher concentrations of Ca and Al. In tandem, the use of a portable spectrometer equipped with an immobilized zinc adeninate benzene tricarboxylate metal-organic framework sensing material makes possible the rapid detection of the presence of ppm concentrations of Tb and Eu in both weakly acidic and strongly acidic process streams within minutes. A solvent extraction processing time of 15-60 min maximized REY selectivity over gangue ions while achieving up to 80% REY and minimal gangue ion recovery. Taken together, these experiments highlight not only an innovative method for REY purification but also the importance of inexpensive, portable characterization methods for near real-time analysis of REY content.

Membrane-assisted solvent extraction↗

Computational Prediction of Infrasound Arrival Times and Directions from Stationary and Moving Impulsive Sources

This report addresses the need to predict infrasound signal arrival times and back azimuths at monitoring stations, enabling more focused and efficient searches within recorded waveform data. The primary challenge is estimating expected signal arrival windows for stationary and moving acoustic sources, such as chemical explosions, volcanic eruptions, meteoroids, and spacecraft re-entry events. To address this challenge, a reproducible methodology is described that uses simplified propagation speeds for boundary layer, tropospheric, stratospheric, and thermospheric atmospheric waveguides. While the Python source code itself is not freely available, this document provides detailed, step-by-step instructions, and equations enabling users to replicate and adapt the method independently. The method reliably predicts signal arrival intervals and back azimuths, thereby supporting rapid detection and accurate interpretation of infrasound events. Results demonstrate that this method effectively identifies plausible signal arrival intervals and directions, facilitating faster event detection and more reliable interpretation. This methodology directly supports atmospheric monitoring, planetary defense, and forensic analysis of explosive atmospheric events.

47 OTHER INSTRUMENTATION↗

BETO 2021 Peer Review - Process Monitoring and Predictions of Biorefinery Performance

Online process monitoring coupled with rapid predictive tools will be essential to refineries of the future to provide real-time feedback and process control on new, renewable feeds and their accompanying processes and products. This project will provide refinery operators with tools to predict product component concentrations in minutes from online, slip stream mass spectra, allowing for rapid detection of off-specification product. We will arrive at a template for predictive tool generation through the development of a specific tool as a starting point -- co-processing of pyrolysis oils and vacuum gas oil over fluid catalytic cracking (FCC) catalysts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Metal-Organic Framework-based Luminescent Sensors for Rare Earth Elements

Rare earth elements (REEs) are crucial for many applications and are particularly important in wind power and electric vehicle technologies, spurring projected demand increases for REEs in coming decades. However, the REE supply is restricted by a monopolistic global marketplace, tedious and costly processing steps for REE production, and environmental hazards associated with mining and processing. Coal and coal-utilization byproducts have emerged as potential domestic sources for REEs, however REE production from these sources is currently hindered by slow and expensive characterization techniques. Here, we demonstrate that metal-organic framework (MOF)-based sensitizers can effectively serve as luminescent sensors capable of rapidly detecting and distinguishing part-per-billion concentration levels of emissive REEs, including terbium, europium, dysprosium, samarium, neodymium, and ytterbium. Importantly, we demonstrate that the MOF structure plays a significant role in tuning the selectivity of the MOF for REEs in acidic environments, an essential step towards deployment in various REE-rich process streams. As a proof-of-concept, we demonstrate sensitive and reversible detection of REEs using a portable fiber-optic spectrometer

Crawford, Scott↗

Power Loss and Safety Risks - Recoverable vs. Non-Recoverable?

This presentation presents an update to the PV fleet analysis on PV system degradation. A median system degradation of -0.7 %/year was found for almost 5000 inverter traces. No significant difference between silicon and CdTe technologies were found. Systems with trackers showed a slightly higher degradation. Silicon technologies such as PERC and heterojunction showed degradation similar to conventional technologies but also showed different degradation mechanisms. To achieve long lifetimes early failure must be minimized through qualification testing. Rapid detection during normal life is important as is the control of bill of materials in modules.

degradation↗

Methods and systems of characterizing and counting microbiological colonies

Described herein are methods, systems, and non-transitory computer-readable media to non-destructively acquire three-dimensional profiles of cellular microbiological samples growing on the surface of a solid growth medium. Acquisitions can be performed by an optical microscope that includes a vertical scanning interferometer. The three-dimensional profiles can enable measurement of sample parameters of microcolonies, which can be made of microbial colony forming units. The methods and systems enable early and rapid detection and quantification of microbes.

Larimer, Curtis J.↗