Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Calibration faceplate for x-ray image intensifiers

Lead crosshairs embedded in detachable, radiolucent intensifier faceplate offers quantitative measurement for X-ray image intensifier. Faceplate provides x-y reference system external to device being photographed.

Rasmussen, D.↗

The design of a multi-detector spectrometer for the infrared

A modified Ebert-Fastie spectrometer has been developed for atmospheric temperature sounding applications. The device is described with reference to its resolution, grating, focal-length mirror, mirror, equivalent f-number, and projected area of grating. The images of the entrance slit appear tilted backwards away from the concave mirror. Astigmatism and spherical aberration are reduced by asperizing the mirror. The resolution and f-number of the instrument are limited by the sagittal coma. The orientation and size of the exit slit are functions of wavelength.

Koch, D. G.↗

Sunlight Simulator for Photovoltaic Testing

Light with normalized spectral irradiance resembling that of airmass 1.5 sunlight striking surface of Earth produced by use of ultraviolet filter to modify output of set of flashlamps used as large-area pulsed solar simulator (LAPSS). Filtered LAPSS light allows more realistic measurements of output of photovoltaic devices when using silicon reference cell having different spectral response characteristic.

Mueller, R. L.↗

Rotatable non-circular forebody flow controller

The invention is a rotatable, non-circular forebody flow controller. The apparatus comprises a small geometric device located at a nose of a forebody of an aircraft and a non-circular cross-sectional area that extends toward the apex of the aircraft. The device is symmetrical about a reference plane and preferably attaches to an axle which in turn attaches to a rotating motor. The motor rotates the device about an axis of rotation. Preferably, a control unit connected to an aircraft flight control computer signals to the rotating motor the proper rotational positioning of the geometric device.

Moskovitz, Cary A.↗

Advanced Modeling of Micromirror Devices

The flexure-beam micromirror device (FBMD) is a phase only piston style spatial light modulator demonstrating properties which can be used for phase adaptive corrective optics. This paper presents a complete study of a square FBMD, from advanced model development through final device testing and model verification. The model relates the electrical and mechanical properties of the device by equating the electrostatic force of a parallel-plate capacitor with the counter-acting spring force of the device's support flexures. The capacitor solution is derived via the Schwartz-Christoffel transformation such that the final solution accounts for non-ideal electric fields. The complete model describes the behavior of any piston-style device, given its design geometry and material properties. It includes operational parameters such as drive frequency and temperature, as well as fringing effects, mirror surface deformations, and cross-talk from neighboring devices. The steps taken to develop this model can be applied to other micromirrors, such as the cantilever and torsion-beam designs, to produce an advanced model for any given device. The micromirror devices studied in this paper were commercially fabricated in a surface micromachining process. A microscope-based laser interferometer is used to test the device in which a beam reflected from the device modulates a fixed reference beam. The mirror displacement is determined from the relative phase which generates a continuous set of data for each selected position on the mirror surface. Plots of this data describe the localized deflection as a function of drive voltage.

Michalicek, M. Adrian↗

Measurement of Turbulent Pressure and Temperature Fluctuations in a Gas Turbine Combustor

The report summarizes the results of the redesign efforts directed towards the gas-turbine combustor rapid-injector flow diagnostic probe developed under sponsorship of NASA-GRC and earlier reported in NASA-CR-2003-212540. Lessons learned during the theoretical development, developmental testing and field-testing in the previous phase of this research were applied to redesign of both the probe sensing elements and of the rapid injection device. This redesigned probe (referred to herein as Turboprobe) has been fabricated and is ready, along with the new rapid injector, for field-testing. The probe is now designed to capture both time-resolved and mean total temperatures, total pressures and, indirectly, one component of turbulent fluctuations.

Povinelli, Louis↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

DEVELOPING AN EARTH-FIXED VISUAL REFERENCE TO AID STABILITY, READAPTATION, AND EGRESS AFTER A WATER LANDING

Water landings present the worst possible sensory conditions for crews trying to orient and stabilize themselves immediately after long-duration spaceflight. Of the three sensory feedback systems involved in maintaining stability (i.e., proprioceptive, vestibular, and visual), none will provide reliable orientation information under the current water landing scenarios. Although the visual system is likely not affected by the disuse and adaptation to microgravity that affect the proprioceptive and vestibular systems, the visual environment within an enclosed space that is subject to wave-induced rocking will prevent the crewmember from using vision to determine which direction is up. This is true whether enclosed in the capsule or in a room on the recovery ship. The result is an increased risk of fall-related injury. In a prior study, 70% (21 of 30) of nonimpaired subjects reported that the presence of an Earth-fixed horizontal line helped them stabilize when their visually enclosed environment was exposed to wave motion. In addition to aiding stability, an Earth-fixed visual reference also can assist in the readaptation process. Sensory re-adaptation occurs when the three sensory systems are synchronized with one another and aligned with Earth’s gravity. The earlier an Earth-fixed visual reference can be introduced the sooner the readaptation process can begin. The goal of this project is to identify the optimal features of a device that visually presents gravitational reference cues to support egress, stability and readaptation. **Remainder of abstract in document preview or downloadable version

B. T. Peters↗

Developing An Earth-Fixed Visual Reference to Aid Stability, Readaptation and Egress After a Water Landing

INTRODUCTION Water landings present the worst possible sensory conditions for crews trying to orient and stabilize themselves immediately after long-duration spaceflight. Of the three sensory feedback systems involved in maintaining stability (i.e., proprioceptive, vestibular, and visual), none will provide reliable orientation information under the current water landing scenarios. The proprioceptive and vestibular systems are affected during spaceflight by disuse and adaptation to microgravity. Vision may not suffer the same degradation, but the visual environment within the enclosed space of a capsule, or interior room of a recovery ship, is disorienting when subject to wave-induced motion. The result is an increased risk of fall-related injury. In a prior study, 70% (21 of 30) of nonimpaired subjects reported that the presence of an Earth-fixed horizontal line helped them stabilize when their visually enclosed environment was exposed to wave motion. In addition to aiding stability, sensory re-adaptation occurs when inputs from the three sensory systems are synchronized with one another and aligned with Earth’s gravity. The earlier an Earth-fixed visual reference can be introduced the sooner the readaptation process can begin. The goal of this project is to identify the optimal features of a device that visually presents gravitational reference cues to support stability and readaptation. METHODS The capsule sensory-condition simulator is a three-sided enclosure atop a six degree-of-freedom motion platform. A sum-of-sines equation is used to drive the motion platform, producing the simulated wave motion. The equation was derived using the frequency range present in inertial measurement unit (IMU) data collected during open-water Orion mock-up testing. The enclosure creates the nature of a floating visual environment where the walls move in relation to the standing surface. To more accurately represent the condition of postflight crewmembers, galvanic vestibular stimulation (GVS) is applied to disrupt normal vestibular function and standing on a compliant surface attenuates proprioceptive feedback. An instrumented handhold allows the subjects to stabilize themselves and serves as the primary dependent variable. Subjects are instructed to minimize handhold use so the higher forces applied to the handhold correspond to greater instability. Various forms of a visual reference have been explored. Passive systems, such as mechanical gimbals and weighted plumb bobs were eliminated from consideration because of the intertia-induced oscillations that the wave-motion causes. Laser lines presented as horizontal, vertical, or the combination of both are being used to provide the Earth-fixed visual reference. These are presented in the central visual field or periphery from laser sources that are mounted either from within or outside the visual enclosure. RESULTS Data collection for this study is currently in progress. CONCLUSIONS This study will determine whether a visual reference system can help improve stability during challenging sensory conditions and define the optimal chacteristics for such a system.

Brian T Peters↗

Electronic load for testing power generating devices

Instrument tests various electric power generating devices by connecting the devices to the input of the load and comparing their outputs with a reference voltage. The load automatically adjusts until voltage output of the power generating device matches the reference.

Friedman, E. B.↗

Real-Time Deposition Monitor for Ultrathin Conductive Films

A device has been developed that can be used for the real-time monitoring of ultrathin (2 or more) conductive films. The device responds in less than two microseconds, and can be used to monitor film depositions up to about 60 thick. Actual thickness monitoring capability will vary based on properties of the film being deposited. This is a single-use device, which, due to the very low device cost, can be disposable. Conventional quartz/crystal microbalance devices have proven inadequate to monitor the thickness of Pd films during deposition of ultrathin films for hydrogen sensor devices. When the deposited film is less than 100 , the QCM measurements are inadequate to allow monitoring of the ultrathin films being developed. Thus, an improved, high-sensitivity, real-time deposition monitor was needed to continue Pd film deposition development. The new deposition monitor utilizes a surface acoustic wave (SAW) device in a differential delay-line configuration to produce both a reference response and a response for the portion of the device on which the film is being deposited. Both responses are monitored simultaneously during deposition. The reference response remains unchanged, while the attenuation of the sensing path (where the film is being deposited) varies as the film thickness increases. This device utilizes the fact that on high-coupling piezoelectric substrates, the attenuation of an SAW undergoes a transition from low to very high, and back to low as the conductivity of a film on the device surface goes from nonconductive to highly conductive. Thus, the sensing path response starts with a low insertion loss, and as a conductive film is deposited, the film conductivity increases, causing the device insertion loss to increase dramatically (by up to 80 dB or more), and then with continued film thickness increases (and the corresponding conductivity increases), the device insertion loss goes back down to the low level at which it started. This provides a continuous, real-time monitoring of film deposition. For use with different films, the device would need to be calibrated to provide an understanding of how film thickness is related to film conductivity, as the device is responding primarily to conductivity effects (and not to mass loading effects) in this ultrathin film regime.

Hines, Jacqueline↗

Eye point-of-regard system

System measures intersection of line of sight and eye point of regard /EPR/ for a human operator in visual scanning system. Device measures two head to reference angles with EPR system and adds them with eye to head angles, yielding a dc signal proportional to picture plane coordinates.

Jex, H. R.↗

The effect of system nonlinearities on system noise statistics

The effects are studied of nonlinearities in a baseline communications system on the system noise amplitude statistics. So that a meaningful identification of system nonlinearities can be made, the baseline system is assumed to transmit a single biphase-modulated signal through a relay satellite to the receiving equipment. The significant nonlinearities thus identified include square-law or product devices (e.g., in the carrier reference recovery loops in the receivers), bandpass limiters, and traveling wave tube amplifiers.

Robinson, L. H., Jr.↗

An investigation for the development of an integrated optical data preprocessor

The successful fabrication and demonstration of an integrated optical circuit designed to perform a parallel processing operation by utilizing holographic subtraction to simultaneously compare N analog signal voltages with N predetermined reference voltages is summarized. The device alleviates transmission, storage and processing loads of satellite data systems by performing, at the sensor site, some preprocessing of data taken by remote sensors. Major accomplishments in the fabrication of integrated optics components include: (1) fabrication of the first LiNbO3 waveguide geodesic lens; (2) development of techniques for polishing TIR mirrors on LiNbO3 waveguides; (3) fabrication of high efficiency metal-over-photoresist gratings for waveguide beam splitters; (4) demonstration of high S/N holographic subtraction using waveguide holograms; and (5) development of alignment techniques for fabrication of integrated optics circuits. Important developments made in integrated optics are the discovery and suggested use of holographic self-subtraction in LiNbO3, development of a mathematical description of the operating modes of the preprocessor, and the development of theories for diffraction efficiency and beam quality of two dimensional beam defined gratings.

Verber, C. M.↗

Speed control device for a heavy duty shaft

A speed control device is characterized by a reference speed shaft spatially related to a heavy duty shaft, a drive train for driving the reference speed shaft at a constant angular velocity, a drive train for driving the heavy duty shaft at a variable angular velocity and a speed control assembly for continuously comparing the angular velocity of the heavy duty shaft with the angular velocity of the reference speed shaft. A brake assembly is connected to the heavy duty shaft and is adapted to respond to errors in the angular velocity of the heavy duty shaft in order to reduce the angular velocity of the heavy duty shaft to that of the reference speed shaft.

Ford, A. G.↗

Determination of physical and chemical states of lubricants in concentrated contacts, part 3

Solid and liquid thin films were analyzed by infrared emission Fourier microspectrophotometry. The apparatus used is a commercial absorption instrument modified to an emission instrument, comprising a rotating polarizing device, a miniature blackbody temperature reference adjustable in temperature and radiant flux and a microscope lens with a high numerical aperture in the entrance system for increased sensitivity and resolution. Studies of lubricant behavior in a simulated ball bearing showed the alignment of the fluid molecules in the Hertzian area. Polyphenyl ether plus 1% 1,1,2-trichloroethane (TCE) required lower shear rates for the same degree of alignment than without TCE. The experiment was run with 440 C stainless steel balls coated with TiN, a chemically inert material. In both cases, the alignment was strongly influenced by the presence of TCE. The results showed (1) the dependence of alignment of fluid molecules on flow and not on adsorption at metallic surfaces, (2) phase separation between lubricant and additive under high pressure which results in two phase flow and (3) reduction in traction of torque transmitting (traction) fluids.

Lauer, J. L.↗

Measuring Absolute Oxygen Pressure

Sensor determines absolute pressure of oxygen without reference pressure source. Absolute oxygen pressure transducer with control circuit enables measurement without reference pressure. Transducer, two part device, combines solid electrolyte membranes sensor with diffusional orifice. Device adapted for direct control of oxygen pressure in combustion mixtures.

Richter, R.↗